HomeMy WebLinkAboutENGINEERINGCONTRACTOR: The Porch Facto,a- . T.LC. DESIGN CRITERIA: Applicable Codes, Regulations, and Standards 1. The 6th Edition (2017) Florida Building Code, specifically Chapter 16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood. 2. AA ASM 35 and AA ADM1 Specifications for Aluminum Structures, Part 1-A of the Aluminum Design Manual prepared by The Aluminum Association. and the AAF Guide to Aluminum Construction in High Wind Areas. 3. ASCE 7-10. Wind Loads 1. Building Occupancy Category, Section 1604.5 and Table 1604.5: Risk Category 1. 2. Basic Wind Speed, Figure 1609.3(3), State of Florida Debris Region & Basic Wind Speed, Section 1609.3.1 and Table 1609.3.1 Equivalent Basic Wind Speed: Vui.T =150 MPH, VASD = 3. Exposure Category, Section 1609.4.3: C 4. Screen Enclosure Section 2002.4 Foundation Design Existing concrete. No additional concrete footing or slab is required to resist the loads imposed upon the existing slab by the proposed construction if the existing slab is a minimum of 4" thick and in sound condition, free from structural cracking, spalling, or other deterioration. Specifications The following specifications are applicable to this project: 1. Where concrete specifications are required, whether in the screen enclosure scope or not, by one or more regulatory agency, the following specifications are applicable: a. Concrete shall conform to ASTM C94 for the following components: i. Portland Cement Type 1,- ASTM C 150 ii. Aggregates - Large Aggregate 3/4" max - ASTM C 33 iii. Air entraining +/- 1% - ASTM C 260 iv.Water reducing agent - ASTM C 494 v. Clean Potable water vi. Other admixtures not permitted b. Metal accessories shall conform to: i. Reinforcing Bars - ASTM A615, grade 60 ii. Welded wire fabric - ASTM A185 c. Concrete slump at discharge chute not less than 3" or more than 5". d. Prepare and place concrete per American Concrete Institute Manual of Standard Practice, Parts 1, 2, and 3 including hot weather recommendations. e. Moist cure or polyethylene curing permitted. f. Prior to placing concrete, treat the entire subsurface area for termites in compliance with the FBC. g. Concrete shall be placed over a polyethylene vapor barrier. h. All aluminum components embedded within concrete shall be coated with a bituminous paint or epoxy. 2. Aluminum extrusions shall be 6005 T5 Alloy 3. Fasteners are required to be corrosion resistant, minimum SAE Grade 2 or better zinc plated to ASTM B633, or coated stainless steel series "300", or uncoated stainless steel series "400". 4. All Self Mating Beam Sections are to be stitched with either #14 screws 6" from ends and 24" center to center or #12 screws 6" from ends and 12" center to center. 5. All Porch Factory Beam Sections are to be stitched with #12 screws, 6" from ends and 12" center to center. 6. Screened enclosures containing swimming pools shall comply with the applicable requirements of FBC R4501.17 Residential Swimming Barrier requirements. 7. Screen material shall be 18/14 screen. unless approved by Suncoast Aluminum Engineering, LLC. 8. Door location shall be determined by contractorin the field. 9. When installing pavers over concrete slab or footing which are supporting aluminum members, such as continuous screen tracks or upright, the pavers must be bonded to the concrete with an epoxy, thinset, or 3,000 PSI grout to ensure full positive contact with concrete. 10. All flashing and waterproofing shall be provided by the contractor. 11. Use of these plans acknowledges and accepts a limit of liability not to exceed design and engineering fee. Roof Type Roof Type: HIPPED GABLE / MANSARD WIND SPEED 1 EXPOSURE HAVE BEEN DETEP ED USING THE ADVANCED TECHNOLOGY COUNCIL'S WEBSITE AND GOOGLE EARTH. SaMNED BY St @wale Coo THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS ST. LIICIE COUNTY B ,G DIVISION A EVIEWED FOR CO, CE REQUIRED BY FIELD INSPECTORS THAT MAYBE NECESSARY IN ORDER TO AJ COMPLY WITH AI L, APPWCANW Co®nt ' REVIEWED BY DaTF, 3l�Li� PLANS AND PERMIT MUST RE KEPT ON JOB �.:�� INSPECTION �v � llt�l,AX. �'— 8'-0- — `i 22'-0' ./ 1X2 TYP �\ o Cx, m LF---TlX2(TYP) n ri 2X2 � r- 0. ri 2X2 a- � 2X2 5'-,C 1 5'-4' 1 5'-4' - o I c � I O n� ri 2X3 1ALt I Tr) O n� a A-2 ri 2X3 1X2(TYP) 04 a //2X3 7'-4' A-4 7'-4' Q7)'-4' RECEIVED MAR 0 7 2m ST. Lucie County, Pemlitting Q'•'' •./dam M �2 i 4p :'4:' LL — V W �__ = e'. C;Q __ co O PR.�F���`�� PROFESSIONAL SEAL CONCEAi ED FAS I ENERS OR Ai ►ACHMENiS ARE THE RESPONSISILP OF THE A=4 CONTRACTOR OF RRIECORO ® ❑ Q cc O "' U Ui w a LL ZI O a� OG C) Q m w �� a� w Z Z Lb Z G Z Z wU 2U w t; H � Z .. 0 ri QU' Z o- F-- Znom $ QL L1 I`w' J R m i3 O w + K N W U inaiV N Z3 ZC70q�== o N W . N N LLJ 0 Q ~ �w Hof u- Cn w w W C'O. n tY U) G) M d ��LL DRAWN BY TP DATE DRAWN 05/02/17 REVISION 02/16/18 SHEET NO: A-1 ALUMINUM MEMBERS DIMENSI'_ } HOLLOW SECTIONS 2 x 2: 2" x 2" x 0.046" 2 x 3: 2" x 3" x 0.050" 2 x 4: 2" x 4" x 0.050" 2 x 5: 2" x 5" x 0.050" OPEN BACK SECTIONS 1 x 2: 1" x 2" x 0.040" 1 x3: 1"x3"x0.045" SNAP SECTIONS 2 x 2 Snap: 2" x 2" x 0.045" 2 x 3 Snap: 2" x 3" x 0.050" 2 x 4 Snap: 2" x 4" x 0.045" SELF MATING (SMB) 2 x 4 SMB: 2" x 4" x 0.044" x 0.100" 2 x 5 SMB: 2" x 5" x 0.050" x 0.100" 2 x 6 SMB: 2" x 6" x 0.050" x 0.120" 2 x 7 SMB: 2" x 7" x 0.05T' x 0.120" 2 x 8 SMB: 2" x 8" x 0.072" x 0.124" 2x9SMB: 2" x 9" x 0.072" x 0. 124" 2 x 10 SMB: 2" x 10" x 0.092" x 0.398" MINIMUM FASTENER EDGE DISTANCE: 1/2" MINIMUM FASTENER SPACING: 3/4" CONCRETE SCREW ANCHOR: SIMPSON TITEN HD OR EQUIVALENT SHEET METAL SCREWS (SMS): ITW / BUILDEX OR EQUIVALENT PFB: PORCH FACTORY BEAM MEMBER SIZE EDGE "C" 2X4 Y" 2x5 —1"- 2X6-2X10 1y" MEMBER SIZE EDGE "C" 3.75 PFB" 5.75 PFB 6.75 PFB 1 Ys' EAVE RAIL (SEE A-1 FOR SIZE) INTERNALLY SCREW THRU BEAM—, W/(3)#10x112'SMS 1"x FASTEN TO EAVE RAIL W/ #10 x 1 1/2" SMS 6" FROM UPRIGHT & 24" O.C. (1) 112" DIA x 21/2" THRU BOLT W/ NYLOCK JAM NUT - IN LIEU OF NYLOCK JAM NUT, JAM NUT W/THREADLOCKER MAY BE USED INSTALLATION REQUIREMENTS: BOLT IS TO BE INSTALLED AS TO NOT DAMAGE BASE MATERIAL DO NO OVER TIGHTEN. PATENT PENDING ii BEAM NOTCHED OVER UPRIGHT (SEE A-1 FOR SIZE) A-1 FOR SIZE) rD UPRIGHT TO BEAM CONNECTION A_2 SCALE: NTS 1/8" x 2" x 2" EXTRUDED ANGLE 5052 H-32 ALLOY EA SIDE l" x 2" O.B. BASE PLATE-TYP 1114 MIN CONC 21/4"MIN CONC v ANCHOR EMBEDMENT .ANCHOR EMBEDMENT ' a a MIN + a 5d MIN EDGE DISTANCE FROM SLAB / FOOTING 4 _ EXTERIOR OF COLUMN TO SEE PLAN o °• ' OUTSIDE EDGE OF SLAB SIDE VIEW (1)1/2" DIA. THRU BOLTw/ NYLOCK JAM NUT - IN LIEU OF NYLOCK JAM NUT, JAM NUT W THREADLOCKER (1) 3/8" DIA. CONCRETE MAY BE USED SCREWANCH0 S I TIGHTEN TO CONTACT -DO NOT (21/4" CONC. EMBED)—� OVERTIGHTEN ' ° �• Al .• r 1" x 2" BASE PLATE ANCHORED TO d CONC W/ 1/4" CONCRETE SCREW ANCHOR (MIN. 1 1/4" EMBED) e SLAB / FOOTING • . . B 6" MAX EACH SIDE OF POST AND SEE PLANMAX FRONT VIEW rB 2" x 4" OR LARGER UPRIGHT TO CONCRETE DETAIL / -2 SCALE: NTS 2" x PURLINS ATTACHED TO BEAM w/MIN (4) #10 x 1 1/2" SMS PLACE WASHER UNDER SCREW IN GUSSET CORNER 3/16" 5052-H32 GUSSET 1 14' NOTE: SEE CALL -OUT BELOW FOR # OF SCREWS. SCREWS SHOWN FOR ILLUSTRATIVE PURPOSES ONLY. DO NOT COUNT — SCREWS ON DRAWING. SMS @ 1 14' O.C. TOTAL) TYP NOTES: 1. GUSSET DIMENSIONS ARE MINIMUM (2) RED D - (1) EA SIDE OF BEAM - MAY BE INTERNAL OR EXTERNAL 2. AS BEAM SIZE CHANGES, ADD OR SUBTRACT SCREWS TO MAINTAIN 1 1/4" C/C SPACING. 3. GUSSET LENGTHS REMAIN CONSTANT, WIDTHS CHANGE TO MATCH BEAM SIZE. 2 1/2" x 1/8" x (GIRT OR PURLIN WIDTH + 1/2" x BEAM DEPTH OR UPRIGHT DEPTH -1/2') ALUM BACKING PLATE 6063-T6 ALUMNINUM CHAIR RAIL MEMBER IT: cv yy. i 1L tll I () <C O •! Y // 111111�� PROFS SIONAL SEAL #10 x 1 1/2" SMS INTO REW BOSSES /BEAM C PURLIN OR GIRT TO BEAM OR POST DETAIL � -2 SCALE: NTS 2"xW 1 " x 2" x 0.044" OPEN BACK FASTEN TO EAVE RAIL W/ #10 x 1 1/2" SMS SPACED 3" FROM UPRIGHT & @ 24" O.C. x PURLIN 2" x 2" x 1/8" x V LONG ALUM ANGLE EACH SIDE UP UPRIGHT W/ (2) #12 x 3/4" SMS INTO PURLIN (2) #12 x 3/4" SMS INTO 2" x 3" (2) #12 x 3/4" SMS INTO UPRIGHT (2) #12 x 3/4" SMS INTO 1" x 2" rF SLOPED PURLIN CONNECTION DETAIL A-2 SCALE: NTS o ❑ D. Ld OV ui d W a fY ao �m LL O —< OC C) . W �� �� ZW Z tCC/� Z zw Lbz LZ Z H Z _ :3W N ZV0 _I W J � J Vr CC Q Z oo 14 14 zmom V1 � ruing$ cg ui Q W &'TT O Lu " mm u z (, Z jE a ' � �l Z C7 m3"^ o m°C`V n W ,mu-u � N Ln W W ILL - W W N d n _ W 0 Q _Do w M O]MLLLL DRAWN BY TP DATE DRAWN 05/02/17 REVISION SHEET NO: A-2 6' WIDE x 0.125"'T' BRACKET @ EACH BEAM ATTACHED TO NOTE: 3/8" LAG SCREWS FOR 1/8" S.S. CABLE 1 x x 1 A�6 GALA. �` \ \ , • • / • • • • • • • /' • . _ /� i� FASCIA W/ 3/8" x 3" LAGS (3 (2) DIA. x 4" SPANS GREATER THAN 30'-0" STEEL CLIP W/ (2) 3/8"DIA T L W1 PER BRACKET) AND (1)3/8"x3" x 2 3/4" EMBEDMENT CONCRETE SCREW LAG @ 24" O.C. AT GUTTER (1) 3/8" DIA x 4" LAG ANCHOR - _ M O O J 1" x 2" x 0.044" OPEN BACK SCREW INTO EXISTING OVERHANG FRAMING a - a F- Q = W/ (2) #10 x 21/2" SMS THRU OR RAFTER TAIL DBL COMPRESSION - V L • BEAM INTO SCREW BOSSES SLEEVES a •e Z co k": Q 1)#10 x 1 1/2" SMS 6" FROM BEAM AND 24" O.C. a •``• O .• J R PROFE SIbNALSEAL SLAB /FOOTING MATING SEE PLAN ELEMENT • • 1/8" S.S. CABLE ❑ • • CONTRACTOR TO VERIFY 1 1/4" x 5 5/8" x 1B" W 2" x 4" FASCIA - IF LESS ALUM FLAT BAR Q LL! G. • 1/8" 2" 2" 7' ALUM THAN 2" x 4" FASCIA 2" x 4" �S'SUPER 6063-T6 ALUMINUM W a x x x • • SUB FASCIA SHALL BE $ Q LLu m ANGLE W/ (4) #14 x 3/4" PLACED OVER, LENGTHEN GUTTER W C7 Z SMS EACH FLANGE EACH SIDE OF BEAM LAG SCREWS TO FULLY SLAB/FOOTER O l+ PENETRATE SUB FASCIA. ® Q W W 0.062" BACKING PLATE ON IF OTHER FASCIA ADD 2" x 4" PT FASCIA 1/2" LAG ` MID DEPTH LLI O m co INSIDE OF GUTTER w/ BOLTS -1 1/2" INTO TRUSS ° �. « W Z z Vf Z Q W 21/8" x 1 1/8" x .062" (MIN.) TAILS - COUNTERSINK FLUSH. WHEN INSTALLING ..' f .< d z W z z ALUM RECEIVING CHANNEL a Z W u O u 2 W/ MIN. (2) #12 x 3/4" SMS 1/2" LAG SCREWS, PRE -DRILL w/ 3/8" DRILL TO W I-- : j of H LL PREVENT SPLITTING. (1) 3/8" DIA. x 3" EMBEDZ SLAB / FOOTING C CONCRETE SCREWANCHOR SEE PLAN' G GUTTER BRACE & MATING ELEMENT ATTACHMENT DETAIL H-_ CABLE CONNECTIONS AT FOUNDATION 0 J A-� SCALE: NTS A-3 SCALE: NTS J tn Qr N Z oO a Z^O a0 V) W pr�mS OW �• �' Imfl {mI1 W U Z � GUSSET PLATE SELF MATING Z (D N 3 v N^_ oa PER ESERIES BEAM = Z J o - - - --- - - - - - - — --- — --- - — N LJJ ."i 4" PURLIN MAX (9) #14 x 3/4 SMS 1/8"PLATE ON 45°ANGLE r -•' r WOOD: CONTRACTOR TO INSTALL 6063-T6 ALUMINUM r #10 x 3" WOOD SCREWS, 6" (2) #14 x 2" SMS THRU BRACE r N FROM GIRT & @ 12" O.C. INTO BEAM THRU GUSSET r ui CONC: PLATE 1/4" DIA. x W CONCRETE • • • • / SCREW ANCHOR, 6° DETAIL #2 FROM GIRT & @ 24" O.C. • / — — — — _ — Q = U (4) #10 x 1 1/2" INTO • / b LL SCREW BOSS • LLIW N a EYE BOLT FOR CABLE TENSION to W fA rn • O cA co LL LL 1 1/2 CONTRACTOR SHALL RUN DRAWN BY 2" x 2" OR 2" X 3" HOLLOW 4„ 1/4" THRU BOLT TO ATTACH W/ NYLON WASHER & PERIMETER FRAMING TP SECTION GIRT MAX. STAINLESS STEEL NUT DATE DRAWN • • 05/02/17 1"xz, 5"Li REVISION 1 1/2" x 5" x 1/8" (4) #12 EA MEMBER 1 5052-H32 PLATE DETAIL #1 SHEET NO: -� 1X2 TO HOST STRUCTURE DETAIL H-3 ROOF BRACING CONNECTION DETAIL H'2 CABLE CONNECTION AT CORNER A-3 SCALE: NTS ^ -3 SCALE: NTS A -3 SCALE: NTS A-3 r 3/16"S.S.CABLE ��� �/j 1 /8" x 6" x 1 14' A-36 GALV. STEEL CLIP W/ 3/8" DIA. VAA! .. , • • (2) x 2 3/4" EMBEDMENT (4) #14 x 3/4" SMS 1/8" x 2" x 2" EXTRUDED • • INTO DJ ANGLE 5052 H-32 ALLOY v CONCRETE SCREW • • \•• !/ i ANCHOR Q ; k LL DBL. COMPRESSION J _ SLEEVES W n 1 Y ' ',r p' a a�• a ° , .. •a 4 q' .. a 1 a ,' 2"'1-MIN CONC " y ; tANCHOR EMBEDMENT SLAB / FOOTING ° a ' .. / � • ,•• (� q 6. a, a .. SEE PLAN r EAL SLAB / FOOTING SEE PLAN SIDE VIEW 3/16" S.S. CABLE ❑ 1 1/4" x 5 5/8" x 1/9' ALUM FLAT BAR (1) 3/8" DIA. CONCRETE cc 0 Ld d i 6063-T5 ALUMINUM SCREW ANCHORS I 2" x 2" DJ Li W W 0- AU a (21/4" CONC. EMBED) I CC m $ Q, lJJ SLAB/FOOTER I O ccQ �m .. MIDDEPTH ......... i m v W CL �> > d• O O �;. �„ e W z z J. ' ;' :t a• 1 "x 2" BASE PLATE Z W z W �i x' s° 4 ANCHORED TO CONC W/ 1/4" ° + u Z > LLI d O u : � CONCRETE SCREWANCHOR ' LLIq _ ie (MIN. 1 1/4" EMBED) m a 3/8" DIX x 3" EMBED 6" MAX EACH SIDE OF POST q • , • q• ; q j, CONC. SCREW ANCHOR SLAB / FOOTING AND 24" O.C. MAX SEE PLAN. a H-4 FRONT VIEW Z c CABLE CONNECTIONS AT FOUNDATION A_4 SCALE: NTS DJ-1 DOOR JAMB TO CONCRETE DETAIL J /�-4 SCALE:NTS J _ QF N Z ow zmoao c� N tim8S QW W m N N W 1" x 2" O.B. FASTENED TO CORNER p ui umi W POST W/ #12 x 1 1/2" SMS AT 6 FROM U TOP & BOTTOM RAILS. TYPICALLY @ Z °qqe -- -[- --- — 24" O.C. - = z m �ur- N W t 118' x 2" x 2" EXTRUDED ANGLE 5052 (18) #14 x 3/4 SMS CORNER POST E f H-32 ALLOY EA CORNER W/ (2) #14 x 2" T SMS INTO POST & (1) 3/8" DIA. 1/8" PLATE ON 45' ANGLE CONCRETE SCREWANCHOR INTO 6" 6063-T6T6 ALUMINUM a CONCRETE ! 1 s (2) #10 x 1 1/2"SMS -- --- — — THRU SCREW BOSSES _-.___ ...__ _ _. —_. _.._ a ;• 21/4"MINCONC • • • • ANCHOREMBEDMENT • • • • / SLAB / FOOTING EYE BOLT FOR CABLE TENSION 1 SEE PLAN °q 4 LLI • • • • / !I! SIDE VIEW Q = W {-2"--} CORNER POST W/ 1"x 2" @ I I tom' LL Ill (4) #14 x 3X' SMS BACKSIDE W IllN INTO POST —� fn 3/8" x LENGTH AS REQUIRED O Q C.) FOR 21/4" EMBED CONCRETE = r O .J SCREWANCHOR INTO ch LL V- _ CONCRETE DRAWN BY 1"x 2" BASE PLATE ANCHORED TO CONC W/ 1/4" �, • ; S°• TP PERIMETER FRAMING t CONCRETE SCREW ANCHOR t (MIN. 1 1/4" EMBED) ® DATE DRAWN �6"sY 6" MAX EACH SIDE OF POST a , a. AND 24" O.C. MAX x 05/02/17 •� REVISION d i ;• a' _ FRONT VIEW SHEET NO: H-5 CABLE CONNECTION AT CORNER A-4 SCALE: NTS CP-1 CORNER POST TO CONCRETE DETAIL A-4 SCALE: NTS A-4 4' Chainlink Fence (to be (Basis of Bearings) N88'11'30"W 260.00'1 Prop. 4' gate (D) (M) Prop 4' CLIP \�\ Back from Top of Slope rox Edge of Water \ Remnants of 4' CLF G (see no \ (to be removed) \\ \\ Top Proposed ool \ ��fS/ope Enclo ure! ,x CL of Creek \ \\ rIJ 3 I'd 5/8" IRC E Not Legible Fd 5/8" IRC I Bent 0.3' South Ili LB 4644 0.5' West I " orainfield om m: Area o Access 77.5' oAccess ' �_.................................... (see note) \\\ \\ \ \ \ Pool Area i \ liryP\ \09 \ 4• 7IP-10 S c� Pavers \ \ \ Prop. 4' Adtio S9S. \ \\ \ gate \ \ \ \ 7rrPrP !.. •. \ \ 00q, (oj �Ml Culvert with _ mitered ends Prop. 12' electric gate Co r �o. 1 W . � �Q, .\\ •.rye^�..�; . .: _ . 3I �\ \\\\ Propose \d.. \ , Driveway, \ .9. Prop. 4' gate \� fdold 3"X3" �\ \ CM Prop. 12' 1 (QT \ Irrig electric gate �\ \\ump \\ VCHOR \ \ \ "E \ CE \ Prop 4' CLF —\ JUMENT CAP RIDS NBOOK7IN ING IMMENCEMENT ) SURVEYOR )D WITH CAP RLS 4506 POLE ind Report urvey depicted hereon as defined in paragraphs 5J-17.050(10)(a)-(k), "Boundary Survey" and "Specific Purpose Survey". The Specific is to locatate the top of slope along Five Mile Creek for depiction of a of the boundary along the centerline of Five Mile Creek and any s not a part of this survey as it is not relevant for the placement of the :e shown below was the date of last field data acquisition for this F O.R. 725, 2990 ' N00°04'37"W (D) N00"08'30"W (M) 1`1 Prop 4' CLF ->,- Set 1/2" IRC RLS 4506 411 c o� en' 1 N69"53"41"W (D) N69°57'34"W (M) 9.88' (D) (M) 1T •I I II II II •I I I fil ='• II� Sign 1 ,1 Additional R%W •i O.R. 725, Pg.291 m N N v 3Fn w c o mzo I �' o o �I�O U C � U z I �j fV C : I Iv O.R. 725, 2990I r-1 o I 502°04'31"E 26 Z I z N01*54'07"E 26 I ' •FH •WUP \ \\ ❑CUP . O N� o cn� �.—`Z I lutili _Bc P.O. B. Set 1/2" IRC RLS 4506 OIU) Set 1/2" IRC RLS 4506 P.O.B. O.R. 725, 2990I �- - Manhole 29 1/ 40.13' (D) (M) 3272 Legal Description Source: Official Records Book 3681, page 1795 That part of the Southeast quarter of the Southeast quarter of Section 29, Townshi St. Lucie County, Florida, more particularly described as follows: From the Southe, 29, run South 85 degrees 11' 30" West, 40.13 feet along the South Section line to' Hawley Road and the Point of Beginning; thence North 00 degrees 08' 30" West, 3 degrees 57' 34" West, 31.94 feet; thence North 88 degrees 11' 30" West, 260.00 fe centerline of Old Five Mile Creek; thence meander said centerline Southeasterly to the Section; thence North 85 degrees 11' 30" East, along said Section line to the P LESS AND EXCEPTING therefrom that portion of the property conveyed to St. Luc way. more Darticularlv described in DPP-d rarnrriprf in nffir,i=l Rarnrria RnMe 79F