Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFr— Florida Building Code Online u BCIS Home Log In User Registration Hot Topl6 '. Fiolitla l`I (�J Product Approval U5ER: Public User .fin";yt:"��1 Product Approval Menu > Product or ADDIIcation Search > A122 • ' • FL # Application Type Code Version ,Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Page 1 of 4 OCANNW ,DBPB°HOdLE! ABOUT UBPR DBPR-01VI910N51 CO4TAOi'UBpR It Surcharge itats Fad. Publications FBC Staff BCIS Site Map Links Search > Application Detail 1� FL17022-R7 Revision v 2017 Approved 08/18/2017v, date reapply 08/21/17 El Extreme Metal Fabricators, LLC 2160 SW Poma Drive Palm City, FL 34990 (772)872-8034 flvalidation@yahoo.com Richard McKuhen flvaildation@yahoo.com Richard McKuhen 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 rchard@emfab.net Category J Roofing Subcategory Metal Roofing i Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed ed 9 P LOCKE BOWDEN the Evaluation Report � Florida License PE-49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Zachary R. Priest, P.E. O Validation Checklist - Hardcopy Received Certificate of Independence FL17022 R7 COI FL 17022.1 S V CRIMP ssr.odf Referenced Standard and Year (of Standard) Standard Year TAS 125 2003 UL 1897 2012 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code https://floridabuilding.org/Dr/Dr am dtl.aspx?param=wGEVXOwtDav2aBOnHnOOe6rMZ... 2/7/2018 Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved of Products Method 1 Option D 08/18/2017 08/25/2017 08/28/2017 10/10/2017 Page 2 of 4 FL # Model, Number or Name Description 17022.1 1 - "5V Crimp" (116) 26 Gauge steel, 3/6" rib height, 24" wide lapped roof panel mechanically attached to 15/32" plywood or Wood Deck with fasteners Limits of Use Approved for, use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions. Install the assembly in compliance with the Installation; method listed in this report and applicable code sections of FBC. Refer to manufacturer's Installation Instructions. Installation Instructions FL17022 R7 II FL 17022.1 5 V CRIMP ssr.odf. Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.Ddf Created by Independent Third Party: Yes 17022.2 2 - "5V Crimp" (116) 0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel, mechanically attached to 15/32" plywood or Wood Deck with exposed fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr,Ddf Verified By: Locke Bowden, P.E. 49704 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for condltions.Install the FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 assembly in compliance with the Installation method listed in ALUM ssr.Ddf this report and applicable code sections of FBC. Refer to Created by Independent Third Party: Yes manufacturer's Installation instructions. I 17022.3 3 - "1.5" Mechanical Seam" (115) 1.5" rib height, 16" wide, 24 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with clips and fasteners. Limits of Use Installation Instructions Approved for use In HVHZ: No FL17022 R7 II FL 17022.3 1.5 MECHANICAL Approved for use outside HVHZ: Yes I seam 24aa ssr,odf Impact Resistant: No Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/ -Table A I Created by Independent Third Party: Yes Other: Refer to evaluation report for conditions and Evaluation Reports limitations of use. Install the assembly In compliance with FL17022 R7 AE FL 17022.3 1.5 MECHANICAL the Installation method listed In this report and applicable seam 24aa ssr.Ddf code sections of FBC. Refer to manufacturer's Installation Created by Independent Third Party: Yes Instructions. 17022.4 14 - "1.5" Mechanical Seam" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in ,compliance with the installation method listed In this report and applicable code sections of FBC. Refer to manufacturer's Installation instructions. 17022.5 15 - "1 In. Nall Strip" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with 1.5" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to 15/32" plywood or Wood Deck with clips and fasteners. Installation Instructions FL17022 R7 11 FL 17022.4 MECHANCIAL SEAM ALUMINUM ssr.Ddf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM ALUMINUM ssr.odf Created by Independent Third Party: Yes 1" rib height, 16" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Installation Instructions FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssr.odf Created by Independent Third Party: Yes htti)s://floridabuilding.org/pr/Pr app dtl.asux?I)aram=wGEVXQwtDgv2aBQt)Hl)QQe6rMZ... 2n/2018 Florida Building Code Online the Installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's Installation instructions. 17022.6 16 - "1 in. Nall Strip" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly In compliance with the installation method listed in this report ar�d applicable code sections of FBC. Refer to manufacturer's Installation Instructions: 17022.7 17 - "1.5 in. Nail Strip" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed In this report and applicable code sections of FBC. Refer to manufacturers Installation 17022.8 J 8 - "EMAX Rib" (115) I Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly In compliance with the installation method listed in this reportland applicable code sections of FBC. Refer to manufacturer's Installation instructions. 17022.9 19 - " PBR MAX" Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for condltions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation Instructions. Page 3 of 4 1" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to attached to 15/32" plywood or Wood Deck with fasteners, Installation Instructions FL17022 R7 Ii FL 17022.6 1.0 NAIL STRIP 0.032 ALUM ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032 ALUM ssr.Ddf Created by Independent Third Party: Yes 1.5" rib height, 19" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Installation Instructions FL17022 R7 II FL 17022.7 1:5 Nail Strip 26GA ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.7 1.5 Nail Strin 26GA ssnodf Created by Independent Third Party: Yes 29 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Installation Instructions FL17022 R7 II FL 177022.8 EMAX Rib ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 177022:8 EMAX Rib ssr,pdf Created by Independent Third Party: Yes 26 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Installation Instructions FL17022 R7 II FL 17022.9 PBR RIB ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.9 PBR RIB ssr.Ddf Created by Independent Third Party: Yes Back Next Contact Us :: '2601 Blair Stone Road. Tallahassee FL 32399.Phone; 650-487-1824 The State of Florida Is an AA/EEO employer, Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibllity Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your a -mall address released in response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), FloddaStatutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one: The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.s., please click.JI Product Approval Accepts: tA, L1!. fl gal �Mcl Credit Card Safe httl)s://floridabuilding.org/Dr/Dr app dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZ... 2/7/2018 Product Report Palm City, Fl. 34990 Compliant with Florida Building Code 201 j (61h ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: EMAX Rib 29GA Steel Roof Panel FBC Sec.1507.4.2 Yield strength: 50 ksi min.; Attached to attached to 15/32" plywood or Wood Deck with fasteners. 36" Coverage (Max.) Rib Height 3/4" Corrosion Resistant Compliant: FBC Sec.1507.4.3 Fastener 1(panel to deck): #10 x 1-1/2" (min.) Hex -Washer Head Wood Screw to penetrate 3/16" (min.) thru bottom of support. Fastener 2 (panel sidelap, ): #14 x 7/8" (min.) Hex -Washer Head Self -Drilling Screw to penetrate 3/16" (min.) thru bottom of support. Underlayment: To be compliant with FBC Sec.1507.1.1 Slope: Shall be in compliance with FBC Sec.1507. Install Details: Table A Allowable Loads METHOD 1 METHOD 2 DESIGN PRESSURE* .86 PSF MAIN FIELD -146 PSF PERIMETER DECK THICKNESS (min.) 15/32" MIN 1S/32" MIN ROW SPACING (min.) 24" 12" FASTENER SPACING ALONG ROW (max.) SEE DETAILS SEE DETAILS PANEL WIDTH (max.) 36" 36" PANEL SEAM (min.) PANEL OVERLAPS PANEL OVERLAPS Reference Data: ARCHITECTURAL TESTING, INC. TST ID#:1527 UL 580-06 & UL 1897-04 TEST REPORT F7247.01-450-44 04/18/16 *DESIGN PRESSURE MARGIN OFSAFE7Y2:1 EQUIVALENCY: UL1897-04 is equivalent to TestAandard UL 1897--IZ. Certificate of Independence: Locke Bowden, P.E. does not have, not will acquire a financial interest in any company manufacturing or disl(k4W1ieapFRrlucts under this evaluation. ,�.+`r 0, Locke Bowden, P.E. is not owned, operated, or controlled by any company, manufacturer, or distrib `l1%� r ustSrttler report. tv •t` �� r ������ r 4 � �` • a� §IWxseal STATE OF ;ky `7�`'•w�L0R1UF� •• f jONA '�,. •',t. f FL 17022.8 EMAX Rib (29GA Steel), 36" Wide Roof Panel - Details Limitations: ' 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 61h ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6'h ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 61h ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report 1 and �ea�ti nrnw0. a Isometric View :W z IN ar Head SeC-0dllcg5aea :poxd 12'm dag p3W leo. Pn4 ieDxk Faslav ux1-M,Hu sMfHtAIVxdSmor -/�r \_;f3JF}lftb-Patel xar�r�a a gyp) )Typiml Fastening Pattern Across Width -Interior) 36 Crnuage N11h l Panel Profile