HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTflnrida Building Code Onime
Page 1 of 2
SCANNED
.
BY
,..� MdeCCUMStLu
Imlt
Bas Home Log In User Registration
Hot Topics Su Surcharge Stats & Facts Publications FBC Stag BCIS SIte Map I Links I Search
Florida
Y
16 1i
�!9 Product Approval
(q USER: Public User
I
Product Approval Menu > Product or Aoolicatlon
Search .> AMlication List > Application Detail
±`
FL #
Application Type
I FL11602-R4
Revision
�(�O
Code Version
Application Status
2017
Approved
r
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
i �Su
O
InterWrap, Inc.
32923 Mission Way
Mission, NON -US 00000
(551) 574-2939
mtupas@interwrap.com
Eduardo Lozano
elozano@interwrap.com
Eduardo Lozano
32923 Mission Way
Mission, NON -US 00000
! (778) 945-2891
elozano@interwrap.com
Roofing
Underlayments
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
J Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
Robert Nleminen
the Evaluation Report
Florida License
PE-59166
Quality Assurance Entity
Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date
09/30/2019
Validated By
John W. Knezevich, PE
i�1 Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL11602 R4 COI 2017 01 COI Nieminen.odf
Standard
ASTM D1970
ASTM D226 (physicals)
FRSA/TRI April 2012
TAS 110 (weathering)
Year
2015
2009
2012
2000
https://floridabuilding.org/pr/pr_app_dtl.aspx?parani=wGEVXQwtDq sQFc5K%2f frZeHY... 2/6/2018
Florida Building Code On ine
Page 2 of 2
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products i
Method 1 Option D
i 10/10/2017
10/11/2017
10/15/2017
12/12/2017
I
FL #
Model, Number or Name
Description
11602.1
Titanium Roof Underiayments
Synthetic sheet -type roof underlayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11602 R4 II 2017 10 FINAL ER INTERWRAP FL11602-
R4.Ddf
Approved fat use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-45
Created by Independent Third'Party: Yes
Other: 1.) The design pressure noted herein pertains to
use of a specific underlayment system beneath foam -on tile
sytsems. Refer to ER Section 5.6.3 for details.12.) Refer to
Evaluation Reports
FL11602 R4 AE 2017 10 FINAL ER INTERWRAP FL11602-
R4.Ddf
ER Sections 5 and 6 for other Limits of Use.
Created by Independent Third Party: Yes
Oack Neat
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-3824
The State of Florida Is an WEED employer. Coovrlohtl 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send
electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If
they have one. The emails provided may be used for official communication with the Ilcensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under
Chapter 455, F.S., please click hgM.
Product Approval Aceepts:
Mgo® F- M
Credit Card
Safe
https:Hfloridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgsQFc5K%2fTrZeHY... 2/6/2018
Q0TR1N1*ERD
EVALUATION REPORT
Interwrap, Inc.
32923 Mission Way
Mission, BC V2V-6E4 Canada
(551)574-2939
EXTERIOR RESEARCH & DESIGN, I.I.C.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
(203) 262-9245
Evaluation Report 111980.11.08-R4
FL11602-R4
Date of Issuance:11/03/2008
Revision 4:10/10/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated fo + compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Titanium'"" Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein. i
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change: Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinityl ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityl ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report�shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The:facsimile seal appearing was authorized by Robert
Nieminen, P.E. on 10/10/2017. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
\I TRINITY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Titaniumm Roof Underlayments, as produced by Interwrap, Inc., have demonstrated
compliance with the intent of the following sections of the 6th Edition (2017) Florida Building Code through testing
in accordance .with applicable sections the following Standards. Compliance is subject to the Installation
Requirements and Limitations / Conditions of Uselset forth herein.
2. STANDARDS:
Section Property Standard Year
1507.1.1, T1507.1.1 Unrolling, BreakinglStrength, Pliability ASTM D226 2009
1507.1.1 Tear Strength ASTM D1970 2015
1507.1.1, T1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015
1507.3.3 Physical Properties) FRSA/TRI April 2012 (04-12) 2012
TAS 110 Accelerated Weathering TAS 110 2000
3. REFERENCES:
KnMy
Examination
Reference
Date
ERD (TST6049)
Physical Properties
115010.04.09
04/29/2009
ERD (TST6049)
Physical Properties
115010.05.10
05/14/2010
ERD (TST6049)
Physical Properties
135520.06.11
06/15/2011
ERD (TST6049)
ASTM D226 !
138010.08.11
08/11/2011
ERD (TST6049)
Wind Uplift
135520.08.11-1
08/12/2011
ITS(TST1509)
ASTM D226 I
311801000Q-003
04/26/2007
ITS(TST1509)
ASTM D226 I
3130639COQ-002A
08/21/2007
ITS(TST1509)
Physical Properties
3126617COQ-005
10/31/2007
ITS(TST1509)
ASTM D226 I
101823107COQ 011
01/23/2015
PRI (TST5878)
ASTM D1970
OCF-841-02-01
09/20/2017
PRI (TST5878)
ASTM D1970; Tear strength
OCF-331-02-02
10/03/2017
PRI(TST5878)
ASTM D1970; Tear strength
OCF-332-02-02
10/03/2017
PRI (TST5878)
ASTM D1970;Tearstrength
OCF-334-02-02
10/,03/2017
ITS (QUA1673)
Quality Control
ITS Listings
Current
ITS (QUA1673)
Quality Control
Service Confirmation
09/30/2017
4. PRODUCT DESCRIPTION:
4.1 Self-Adherina Underlayments:
!
4.1.1 Titanium'"' PSU-30 is an unreinforced polymer modified bitumen material adhered to the underside of a
polymer -coated, synthetic woven sheet. The underside is backed with a release film. Unit weight 24
Ibs/square. Meets ASTM D1970 as a single -layer and meets FRSA/TRI April 2012 when used in 2-ply system.
4.2 Mechanically Fastened Underlayments:
4.2.1 Titanium'"' UDL-25 is a synthetic sheet -type underlayment comprised of a woven core coated on one side
with a polymer coating. Unit weight 2.5 Ibs/square. Meets FBC 1507.1.1 (Exception).
4.2.2 TitaniumTM' UDL-30 is a synthetic sheet -type underlayment comprised of a woven core coated on both sides
with a polymer coating. Unit weight 4.0 Ibs/square. Meets FBC 1507.1.1 (Exception). ,
4.2.3 TitaniumTM UDL-50 is a synthetic sheet -type underlayment comprised of a woven core coated on both sides
with a polymer coating. Unit weight 4.7 Ibs/square. Meets FBC 1507.1.1 (Exception).
Exterior Research and Design, I.I.C. Evaluation Report 111980.11.08-R4
Certlfiwte ofAuthoriratlon N9503 6'" EDITION (7017) FBC NON-HVH2 EVALUATION' F1.11602-114
Titanium Roof Underlayments Revision 4:10/10/2017
Page 2 of 7
",,TRINITY � ERD
S. LIMITATIONS:
I
5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project onjjwhich this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidancelunless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in l FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this reort; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Titanium'' Roof Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC aplproval documents. If not listed, a request may be made to the
Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the
prepared roof covering.
I
5.5 Allowable Roof Covers:
„.. •Table 1: Roof Cover Options
Asphalt
Wood Shakes
Underlayment
Shingles
Nail -On Tile
Foam -On Tile
Metal
& Shingles
Slate
Titanium PSU-30
I
Yes
(Silvassa, India)
Yes: ,
Yes" I i
(See 5 Sii)
Yes ' ' i
yes 1
Yes -
Titanium PSU-30
Yes
`No
No
Yes
Yes
Yes '
(Brentwood, NH)
i
Titanium UDL-25
.Yes
IN ^!
y INo
yesr 1
Yes
i `Yes
.:j
Yes
Yes,
Titanium UDL-30
yes
.(ea:esneetlnx Ply ,
`:,IBase'Sheetln2-ply
Yes
" syitem)
system)
j
Titanium UDL-50
.Yes
; ; No
f iNo; i
; Yes `
Yes`. ,
yes
,
5.5.1 "Foam -On Tile" is limited to use of following Approved tile adhesives / underlayment combinations.
TABLE,IA: ALLOWABLE TILE'ADHESIVE' UNDERLAYIVIENT_COMBINATIQNS ; _? < . ;',; ' :. • :,' ; :'' _` ,
Adhesive
Florida Product Approval
Underlayments
Dow TileBond'"
FL22525
Titanium PSU-30 (Silvassa, India)
ICP Adhesives Polysetm AH-160
FL6332
Titanium PSU-30 (Sllvasso, India)
5.6 Allowable Substrates: Titanium PSU-30:
5.6.1 Direct -Bond to Deck:
➢ New untreated plywood;
➢ Existing untreated plywood, primed as needed with D41 primer to achieve bond.
5.6.2 Bond to Mechanically Attached Base Sheet:
➢ ASTM D226, Type I or II felt.
➢ Titanium UDL-30 (primed with 641 primer) or UDL-30 (inverted).
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design, I.I.C. Evaluation Report 111980.11.08-R4
Certljlcate ofAuthori:ation #9503 6T" EDITION (2617) FBC NON-HVHZ EVALUATION F1.11602-114
Titanium Roof Underlayments Revision 4:10/20/2017
Page of 7
i
VT__-RINITY ERD
5.6.3 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI .April 2012 (04-12)
does not address wind uplift resistance) of all underlayment systems beneath foam -on the systems, where
the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment
systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used In foam -on tile applications.
Maximum Design Pressure is the result! of testing for wind load resistance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has
already been applied). Refer to. FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for
determination of design wind loads.
#1 Maximum Design Pressure = -45 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional) ASTM D41
Underlayment: One or two plies, Titanium PSU-30 (Silvassa, India), self -adhered
#2 Maximum Design Pressure = -30 psf*:
Deck: Min. 15/32-inch plywolod to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Titanium UDL-30 (inverted)
Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch
diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch
with min. 32 ga., 1-5/8" 'diameter tin caps
Spacing: 6-inch o.c. at 4-inch wide side laps and 12-inch o.c. at three (3), equally spaced center rows.
Primer: ASTM D41 primer required at all tin -caps.
Underlayment: One or two plies, Titanium PSU 30 (Silvassa, India), self -adhered
#3 Maximum Design Pressure = -30 psf*:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Titanium UDL-30 (printed side up)
Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch
diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch
with min. 32 ga., 1-5/8" diameter tin caps.
Spacing: 6-inch o.c. at 4-inch wide side laps and 12-inch o.c. at three (3), equally spaced center rows.
Primer: ASTM D41 primer required over printed side of UDL-30.
Underlayment: One or two'plies, Titanium PSU 30 (Silvassa, India), self -adhered
#4 Maximum Design. Pressure =-45 nsf*:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet:
Titanium UDL-30 (inverted)
Fasteners:
12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch
diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch
with min. 32 ga., 1-5/8" diameter tin caps
Spacing:
6-inch o.c. at 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced center rows.
Primer:
ASTM D41 primer required at all tin -caps.
Underlayment:
One or two plies, Titanium PSU 30 (Silvassa, India), self -adhered
#5 Maximum Design Pressure = -45 psf*:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet:
Titanium UDL-30 (printed side up)
Fasteners:
12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch
diameter and length, sufficient to penetrate through the thickness of deck not less than 3/16-inch
with min. 32 ga.,1-5/8" diameter tin caps.
Spacing:
6-inch o.c. at 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced center rows.
Primer:
ASTM D41 primer required over printed side of UDL-30.
Underlayment:
One or two plies, Titanium PSU 30 (Silvassa, India), self -adhered
Exterior Research and Design, I.I.C. Evaluation Report 111980.11.08-R4
Certificate ofAuthoN:ation #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R4
Titanium Roof Underlayments Revision 4:10/10/2017
Page 4 of 7
TRINITY I ERD
5.6.3.1 For mechanically attached Base Sheet ,Ithe maximum design pressure for the selected assembly shall meet
or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1
design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria.
Commonly used methods are ANSII SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in r_
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Titanium UDL-25, Titanium UDL-30 or!4itanium UDL-50 shall not be left exposed for'longer than,30-days.
Titanium PSU-30 (Silvassa, India) shall not be left exposed for longer than 90-days.
Titanium PSU-30 (Brentwood, NH) shall not be left exposed for longer than 30-days.
5.8 Tile Slippage Limitations fper FRSA/TRI April 2012 (04-12)1:
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by using battens during loading of the roof
tiles. .
TABLE2:.TILE•SLIPPAGOJMITATIONSFOR DIRECT-DECKTILEINSTALL•ATIONS*"-
Underlayment
Tile Profile
Staging Method
Maximum
Slope
Titanium PSU-30 (Silvasso,lndio)
Flat
Max. 10-tile stack
5:12
Lugged
Max. 10-tile stack
6:12
6. INSTALLATION:
i
6.1 Titanium Roof Underlayments shall be installed in accordance with Interwrap published installation
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable).
.6.3 Titaniumrm UDL-25, Titanium UDL-30 orTitanium.UDL-50:
6.3.1 Shall ,be installed in compliance with the requirements for ASTM D226, Type I or 11 underlayment in FBC
Table 1507.1.1 for the type of prepared roof covering to be installed, taking into account the wider sheet -
width for double -layer applications.;
6.3.2 Fasteners:
Mechanical attachment of Titanium UDL-25 and Titanium UDL-30 is limited to ring shank roofing nails with
minimum 1-inch diameter plastic caps.
Mechanical attachment of Titanium UDL-50 is limited to ring shank roofing nails with minimum 3/8-inch
diameter heads; ring shank roofing nails with minimum 1-inch diameter plastic caps; screws and plates; or
plastic cap staples.
6.3.3 Slopes of 4:12 or greater:
End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4-inches.
Minimum attachment shall be 12-inches o.c. vertically and 24-inches o.c. horizontally in accordance with
the surface markings on the exposed face of the underlayment. When batten. systems are to be installed
atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the
battens.
Exterior Research and Design,LLC. Evaluation Report 111980.11.08-R4
Certiflcate of AuthorisationN9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.11602-114
Titanium Roof Underlayments Revision 4:10/10/2017
Page 5 of
TRINITY � ERD
6.3.4 Slopes of 2:12 to less than 4:12:
Double layer application; begin by fastening a 25-inch wide strip along the eaves. Place a full -width sheet
over the starter, completely overlapping the starter course. Continue as noted in 6.3.3, but maintaining
minimum 25-inch side (horizontal) laps resulting in a double -layer application.
6.4. Titanium'".PSU-30:
6.4.1 Shall be installed in compliance with the codified requirements for ASTM'D1970'underlayment in FBC Table
1507.1.1 for the type of prepared rooflcovering to be installed.
6.4.2 Direct -to -Deck with Mechanically Fastened Roof Cover:
Cut manageable sections and re -roll with the release film side out.
Membrane Application:
➢ Peel back release film approximately 1 to 2 feet and align with the lower edge of the roof and set in
place, printed side up.
➢ Apply the balance of the membrane to the substrate by removing the film and firmly pressing the
membrane into place.
➢ Apply subsequent courses parallel,to the eave in a shingle -type, water -shedding manner.
➢ End (vertical) laps shall be minimum 12-inches and side (horizontal) laps shall be minimum 3-inches.
➢ If the membrane becomes misaligned, cut the roll and re -start.
➢ Upon completion, inspect the membrane and repair any defects or fish -mouths.
The use of sealant or mastic at tile fastener penetrations Is required for all tile roofing installations. Contact
Interwrap for approved sealant or mastic types.
6.4.3 Tile Applications [Titanium PSU-30 (511vasso, India) onlyl:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment.
Refer to Table 2 herein, and Interwrap published requirements for tile staging. Interwrap specifies
minimum 24-hour cure time after installation, before loading of roofing tiles.
The use of sealant or mastic at tile fastener penetrations is required for all tile roofing installations. Contact
Interwrap for approved sealant or mastic types.
6.5 Titanium 2-Ply System:
6.5.1 The Titanium 2-Ply System consists of a base layer of Titanium UDL-30 (top -surface primed or inverted)
mechanically attached to the wood] roof deck followed by Titanium PSU-30 (Silvassa, India), self -adhered.
6.5.2 Non -Tile Applications:
Install Titanium UDL-30 (top surface primed or inverted) in accordance with Sections 6.3.1 through 6.3.3
followed by Titanium PSU-30 (Silvassa, India) in accordance with Section 6.4.
6.5.3 Tile Applications: ,
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.`
For mechanically fastened tile roofing, refer to Interwrap published installation instructions, but not less
than the fastener density from FRSA/TRI April 2012 (04-12), Table 1.
For adhesive -set tile roofing, refer to Section 5.6.3 herein.
Tile shall be loaded and staged in ;a manner that prevents tile slippage and/or damage to the underlayment.
Refer to Table 2 herein, and Interwrap published requirements for tile staging. Interwrap specifies
minimum 24-hour cure time after, installation, before loading of roofing tiles.
The use of sealant or mastic at tile fastener penetrations is required for all the roofing installations. Contact
Interwrap for approved sealant or mastic types.
Exterior Research and Design, I.I.C. Evaluation Report 111980.11.08-R4
Certifieate of Authorization 0503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-114
Titanium Roof Underlayments Revision 4:10/10/2017
Page 6 of 7
�l TRINITY ERD
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority' Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFAcrURING PLANTS:
i
Contact the noted CA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements.
The following plants have qualified products under their respective phvsical properties specifications.
Plant
Products
Mission, BC, Canada
FBC 1507.1.1(Exception)
Titanium UDL-30; Titanium UDL-50
Qingdao, China
FBC 1507.1.1(Exception)
Titanium UDL-25; Titanium UDL-30; Titanium UDL-50
Silvassa, India
FRSA/TRI 04-12 (2-ply system)
Titanium PSU-30 (Silvassa, India)
Brentwood, NH
ASTM D1970 - I
Titanium PSU-30 (Brentwood, NH)
9. QUALITY ASSURANCE ENTITY:
Intertek Testing Services NA Inc. — QUA1673; (604) 520-3321
- END OF EVALUATION REPORT -
0
Exterior Research and Design, LLC. Evaluation Report 111980.11.08-R4
Certificate of Authorization #9503 6r" EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-114
Titanium Roof Underlayments Revision 4:10/10/2017
Page 7 of 7