HomeMy WebLinkAboutREVISIONOFFICE USE ONLY::
DATE FILED: 10N
REVISION FEE: "I 1 .O
SCANNED
B
!3i Luele C0Un$Y
PERMIT # 1803-0205
RECEIPT # ` 51
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-5652 RECEIVED }
1 (772) 462-1553
APPLICATION FOR BUILDING PERMIT REVI IONS MAR 19 2018
PROJECT INFORMATION
ST. Lucie County, Permitting
LOCATION/SITE
ADDRESS:
656 SE HIDDEN RIVER DR PORT ST LUCIE, FL 34983
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
DUE TO MATERIAL SHORTAGE THE UNDERLAYMENT WILL BE CHANGED FROM TITANIUM PSU 30 TON 4g 10 519 T u AIRK
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: CCC1330649
BUSINESS NAME: ALL AREA ROOFING & G
QUALIFIERS NAME: ANDREW GRIFFIS
ADDRESS: 3921 S US HWY 1
CITY: FT PIERCE STA
PHONE (DAYTIME): 772-464-6800
OWNER/BUILDER INFORMATION:
NAME: ALBERT SCHWARTZ
ADDRESS: 656 SE HIDDEN RIVER DR
CITY: PORT ST LUCIE
PHONE (DAYTIME: 772-342-5733
: FL
STATE: FL
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY:
PHONE (DAYTIME):
STATE:
ST. LUCIE CO CERT. #: 30522
ZIP: 34982
FAX: 772-464-6600
hFAV&V
ZIP: 34983
ZIP:
ff
Iff lap
Fm I L C Y
Revised 0613 0/17
REVISKJ
*Florida Building Code Online
Page 1 of 2
7 7
BCIS Home I Log In I User Registration Hot Topics submit surcharge Stats & Facts Pubilcations I FBC Stag I BCIS Site Map I Links I ,Search 'I
Florida
..,, j Product Approval
USER: Public User r I Product ApproVal Menu > Product or Application Search > Application List > Application Detail
FL # FL5259-1127 � L
Application Type Revision ( C
Code Version 2017 I /}'/�l w
Application Status Approved Y 1
1k 1
Comments
Archived
��CEIVED
Product Manufacturer POLYGLASS USA
Address/Phone/Email Dill W. Newport Center Drive
Deerfield Beach, FL 33442 MAR 19 2018
(954) 233-1378 Ext242
alender@polyglass.com
180j , 0,3 County, Permi
n
Authorized Signature Ariel Lender ST. LITCrF C`OUNTX. BIJ1L. _ IVISION
alender@polyglass.com R-EVIEWED FOR COMP
REVIEWE BY
Technical Representative Maury Alpert
Address/Phone/Email Deli W. Newport Center DriveDATE
AND PERMIT �S&'
PT ON JOB
Deerfield Beach, FL 33442
(912) 429-8610 OR NO INSPECTION i1'��;,
MAIpert@polyglass.com
Quality Assurance Representative Ariel Lender THESE PLANS AND ALL PROPOSED WORK
Address/Phone/Email 1111 W. Newport Center Drive ARE SUBJECT TO ANY CORRECTIONS
Deerfield Beach, FL 33442
(954) 233-1230 REQUIRED BY FIELD INSPECTORS THAT
ALender@polyglass.com MAYBE NECESSARY IN ORDER TO
Category Roofing COMW WIrd IAU,.APFWQASW 00090,
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
=; Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen CONMED FASTENERS OR ATTACHMENTS the Evaluation Report ARE THE RESPONSIBILITY OF THE
Florida License PE-59166
Quality Assurance Entity UL LLC
CONTRACTOR OF RECORD
Quality Assurance Contract Expiration Date 10/05/OS/2018
Validated By John W. Knezevich, PE
✓i Validation Checklist - Hardcopy Received
I
Certificate of Independence FL5259 R27 COI 2017 01 COI Nieminen.odf
Referenced Standard and Year (of Standard) Standard Year
ASTM D1970 2015
ASTM D226 2009
ASTM D6164 2011
ASTM D6222 1
FM 4474 PY
FRSA/TRI April 2012FILE 2
TAS 103 5
TAS 110 2000
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3 Crk2vS%... 2/6/2018
-Florida Building Code Online
Page 2 of 2
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Date Revised
Summary of Products
UL 1897
Method 1 Option D
09/14/2017
09/15/2017
09/18/2017
12/12/2017
01/24/2018
2012
FL #
Model, Number or
Name
Description
5259.1
Polyglass Roof
goofing underlayments
Underlayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL5259 R27 11 2017 09 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
k27.DdF
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure In this
Evaluation Reports
application relates to one particular
IFL5259 R27 AE 2017 09 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
27.Ddf
underlayment system (over concrete
deck) for use under foam -on tile systems
Created by Independent Third Party: Yes
(where the underlayment forms part of
the load -path). Refer to ER Section 5.6.4
for other systems, other deck types and
associated maximum design pressures.
2.) Refer to ER Section 5 for other limits
of use.
Oeck Noxt
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phona: 850-487-1824
The State of Florida Is an WEED employer. CoovriahI t 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. it you do not want your e-mail address released in response to a pbbllc-records request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, �012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department Ith an email address which can be made available to the public. To determine Ir you are a licensee under
Chapter 455, F.S., please cllck hgM.
Product Approval Accepts:
W1 NiN E .
Credit Card
Safe
https://floridabuilding. org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3 Crk2vS%... 2/6/2018
QOTRINITYIERD
EVALUATION REPORT
Polyglass USA, Inc.
150 Lyon Drive
Fernley, NV 98408
(570) 384-1230
SCOPE:
This Evaluation Report is issued under Rule 61G20-3
construction materials in the State of Florida. The docum
for use of the product under the Florida Building Code
described herein have been evaluated for compliance w
herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the require
CONTINUED COMPLIANCE: This Evaluation Report is valid u
Quality Assurance documentation changes, or provisions i
Evaluation Report by the named client constitutes agreen
referenced Quality Assurance documentation changes. 1
relative to updated Code requirements with each Code Cy
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
(203) 262-9245
Evaluation Report P12060.02.09-1123
FL5259-R27
Date of Issuance: 02/24/2009
Revision 23: 09/14/2017
nd the applicable rules and regulations governing the use of
:ntation submitted has been reviewed by Robert Nieminen, P.E.
and Florida Building Code, Residential Volume. The products
th the 6th Edition (2017) Florida Building Code sections noted
ents the Accredited Quality Assurance Agency noted herein.
it such time as the named product(s) changes, the referenced
the Code that relate to the product change. Acceptance of this
nt to notify Robert Nieminen, P.E. if the product changes or the
nityIERD requires a complete review of this Evaluation Report
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation'RepI rt is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 14.
Prepared by:
1
�+' �'' r' The facsimile seal appearing was authorized b Robert Nieminen,
Robert J.M. Nieminen, P.E. �,,T��.^ .c�;o.{,:,;:� pp g y
iry'�S��OUaLE:
Florida Registration No. 59166, Florida DCA ANE1983 �,,,,,,,,,,,, �� P.E. on 09/14/2017. This does not serve as an electronically
signed document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity) ERD does not have, nor does it intend to acquire o� will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does`not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as proc
following sections of the 5th Edition (2014) Florida Bull
Compliance is subject to the Installation Requirements a
2. STANDARDS:
�l TRINITY ERD
uced by Polyglass USA, Inc., have demonstrated compliance with the
ling Code through testing in accordance with the following Standards.
id Limitations / Conditions of Use set forth herein.
Section
Progerty
Standard
Year
1504.3.1
Wind Uplift
FM 4474
2011
1504.3.1
Wind Uplift
UL 1897
2012
1507.2.3 / 1507.1.1
Physical Properties
ASTM D226
2009
1507.2.4 / 1507.1.1, 1507.2.9.2
Physical Properties
ASTM D1970
2015
1507.3.3
Physical Proper
ies
FRSA/TRI April 2012
2012
1507.11.2
Physical Proper
ies
ASTM D6164
2011
1507.11.2
Physical Properties
ASTM D6222
2011
1523.6.5.2.1
Physical Properties
TAS 103
1995
TAS 110
Accelerated Weathering
TAS 110
2000
3. REFERENCES:
kniiv
Examination
Reference
Date
FM Approvals (TST 1867)
Wind Uplift
3004091
01/12/2000
PRI (TST 5878)
Physical Prope ies
PRI01111
04/08/2002
PRI (TST 5878)
Physical Properties
PUSA-005-02-01
01/31/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-01
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-02
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-03
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-018-02-01
07/14/2003
PRI (TST 5878)
Physical Properties
PUSA-028-02-01
07/13/2005
PRI (TST 5878)
Physical Properties
PUSA-033-02-01
01/12/2006
PRI (TST 5878)
Physical Properties
PUSA-035-02-01
09/29/2006
PRI (TST 5878)
Physical Properties
PUSA-055-02-02
12/10/2007
PRI (TST 5878)
Physical Properties
PUSA-061-02-02
01/28/2008
PRI (TST 5878)
Physical Properties
PUSA-076-02-01
02/22/2008
PRI (TST 5878)
Physical Properties
PUSA-083-02-01
04/14/2008
PRI (TST 5878)
Physical Properties
PUSA-088-02-01
07/29/2009
MTI (TST 2508)
Physical Properties
JX20H7A
04/01/2008
MTI (TST 2508)
Physical Properties
RX14E8A
01/29/2009
ERD (TST 6049)
Physical Properties
11752.09.99-1
02/08/2000
ERD (TST 6049)
Wind Uplift
11757.08.01-1
08/13/2001
ERD (TST 6049)
Wind Uplift
11776.06.02
01/16/2003
ERD (TST 6049)
Physical Properties
02200.07.03
07/14/2003
ERD (TST 6049)
Wind Uplift
P1740.01.07
01/04/2007
ERD (TST 6049)
Physical Properties
P5110.04.07-1
04/11/2007
ERD (TST 6049)
Wind Uplift
P9260.03.08
03/21/2008
ERD (TST 6049)
Physical Properties
P13450.08.09
08/13/2009
ERD (TST 6049)
Wind Uplift
P30540.11.09-111
11/30/2009
ERD (TST 6049)
Physical Properties
P11030.11.09-1
11/30/2009
ERD (TST 6049)
Wind Uplift
P11030.11.09-2
11/30/2009
ERD (TST 6049)
Physical Properties
P11030.11.09-3
11/30/2009
ERD (TST 6049)
Physical Properties
P33360.06.10
06/25/2010
ERD (TST 6049)
Physical Properties
P33370.03.11
03/02/2011
ERD (TST 6049)
Physical Properties
P33370.04.11
04/26/2011
ERD (TST 6049)
Physical Properties
P37300.10.11
10/19/2011
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-1123
Certificote ofAuthorizotion#9503 ell EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 2 of 14
",,,[TRINITY ERD
Entity
Examination
Reference
Date
ERD (TST 6049)
Physical Prope ies
P40390.08.12-1
08/06/2012
ERD (TST 6049)
Physical Prope ies
P40390.08.12-2
08/07/2012
ERD (TST 6049)
Physical Properties
C41420.09.12-3
09/11/2012
ERD (TST 6049)
Wind Uplift
P39680.03.13
03/04/2013
ERD (TST 6049)
Physical Properties
P45370.04.13
04/26/2013
ERD (TST 6049)
Wind Uplift
P1738.02.07-R2
04/29/2013
ERD (TST 6049)
Wind Uplift
11757.04.01-1-R1
04/30/2013
ERD (TST 6049)
Wind Uplift
P41630.08.13
08/06/2013
ERD (TST 6049)
Wind Uplift
P11751.05.03-R1
11/26/2013
ERD (TST 6049)
Wind Uplift
P11781.11.03-R1
11/26/2013
ERD (TST 6049)
Physical Properties
P45270.05.14
05/12/2014
ERD (TST 6049)
Physical Properties
6020.07.14-1
09/08/203.4
ERD (TST 6049)
Physical Properties
6020.09.14-2
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-3
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-4
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-5
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-6
09/08/2014
ERD (TST 6049)
Physical Properties
P46520.10.14
10/03/2014
ERD (TST 6049)
Physical Properties
P44360.10.14
10/07/2014
ERD (TST 6049)
Physical Properties
P43290.10.14
10/17/2014
ERD (TST 6049)
Physical Properties
PLYG-SC7550.03.15
03/24/2015
ERD (TST 6049)
Physical Properties
P40390.04.15
04/03/2015
ERD (TST 6049)
Physical Properties
PLYG-SC8080.05.15-1
05/20/2015
ERD (TST 6049)
Wind Uplift
PLYG-SC8905.05.16-1
05/17/2016
ERD (TST 6049)
Physical Properties
PLYG-SC8080.07.16
07/16/2016
ERD (TST 6049)
Wind Uplift
PLYG-SC12025.10.16
10/12/2016
ERD (TST 6049)
Physical Prope ies
PLYG-SC13040.12.16
12/27/2016
ERD (TST 6049)
Physical Properties
PLYG-SC11900.03.17
03/10/2017
ERD (TST 6049)
Physical Properties
PLYG-SC12115.08.17
08/08/2017
ICC-ES (EVL 2396)
IBC Compliance
ESR-1697
11/01/2014
Miami -Dade (CER 1592)
HVHZ Compliance
NOA 14-0717.08
01/22/2015
Polyglass USA
Manufacturing Affidavit
Products Current
02/18/2009
Polyglass USA
PA Affidavit
Mule -Hide Cross Ltg
03/01/2008
Polyglass USA
Materials Affidavit
Polystick SA Compound
08/18/2011
UL, LLC. (QUA9625)
Quality Control
Service Confirmation
Exp. 10/05/2018
4. PRODUCT DESCRIPTION:
4.1 Mechanically Fastened Underlayments;
4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet.
4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet.
4.1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet.
4.1.4 Polyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet.
4.2 Self -Adhering Underlayments:
4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced
with polyolefinic film surface; meets TAS 103.
4.2.2 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an
aggregate surface; meets ASTM D1970.
4.2.3 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a
polyester fabric surface; meets ASTM D1970 and TAS 103.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-1123
Certificate of Authorizotion #9503 6Tx EDITION (2017) FBC NON-HVHZ EVALUATION F1.5259-1127
Polyglass Roof Underlayments; (570) 384-1230 i Revision 23: 09/14/2017
Page 3 of 14
Q"TRINITY�ERD
4.2.4 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester
reinforced, with a granular surface; meets ASI M D1970 and TAS 103.
4.2.5 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/mz polyester
fabric surface; meets ASTM D1970 and TAS 103.
4.2.6 Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are polyester
reinforced, APP modified bitumen cap sheets meet FRSA/TRI April 2012.
4.2.7 Polystick Dual ProTM' is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; m leets ASTM D1970.
4.2.8 Polystick Tile Pro'"' is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103.
4.2.9 Polystick MU-X is a nominal 54-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section
5.8).
4.3 Mechanically Fastened and/or Bonded•Underlayments:
4.3.1 Elastoflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of a sand -surfaced SBS
modified bitumen back -side and granule -surfaced APP modified bitumen top -side. Elastoflex G TU is for use as an
alternate to "Mineral Surface Roll Roofing" AASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened tile roof systems or Hot As applied "Cap Sheet" in the "Two Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems.
4.3.2 Elastoflex S6 G and Elastoflex S6 G FR are poyester reinforced, SBS modified bitumen cap sheets; meet ASTM D6164.
Elastoflex S6 G and Elastoflex S6 G FR are or use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380,
Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems.
Elastoflex S6 G is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI
April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 G FR is for use as an
alternate to Hot Asphalt applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath
mechanically fastened tile roof systems.
4.3.3 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222.
Polyflex G is for use as an alternate to Heat lPpplied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012
(04-12) beneath mechanically fastened or adhered tile roof systems. Polyflex G FR is for use as an alternate to Heat
Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically fir that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-R23
Certificate o/Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL52S9-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 4 of 14
��TRINI*ERD
5.5 Allowable Roof Covers:
TABLE
1: ROOF COVER OPTIONS
Underlayment
Asphalt Shingles
Nail -On Tile
Foam -On Th
Metal
Wood Shakese
8: Shingles
g
Slate
Elastobase
Yes
Yes
(Base Sheet in 2-ply
system)
Yes
(Base Sheet In 2-ply system)
Yes
Yes
Yes
Elastobase P
Yes
Yes
Base Sheet In 2-
( P,
I
I system)
V Y )
Yes
(Base Sheet in 2-ply systems
Yes
Yes
Yes
Polyglass G2 Base
No
Yes I
(Base Sheet in 2-ply system)
Yes
(Base Sheet In 2-ply system)
No
No
No
Polyglass APP Base
No
Yes I
(Base sheet In 2-ply system)
Yes
(Base Sheet in 2-ply system)
No
No
No
Polystick MTS
Yes
Yes
No
Yes
Yes
Yes
Polystick IR-Xe
Yes
No
No
No
Yes
Yes
Polystick TU P
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polystick TU Plus
Yes
Yes
Yes (See 5.5.1)
Yes
Yes
Yes
PolystickTU Max
No
Yes
Yes (See 5.5.1)
Yes
No
No
Polystick Dual Pro
Yes
No
No
Yes
Yes
Yes
Polystick Tile Pro
Yes
Yes
Yes (See 5.5.1)
Yes
Yes
Yes
Polystick MU-X
Yes
No
No
Yes
Yes
Yes
Elastoflex S6 G
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Elastoflex S6 G FR
Yes
Yes
No
No
Yes
Yes
Elastoflex G TU
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polyflex G
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polyflex G FR
Yes
Yes
No
No
Yes
Yes
Polyflex SAP or SAP FR
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Mule -Hide SA-APP Cap Sheet
or SA-APP Cap Sheet (FR)
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations.
TABLE
IA: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS)
Adhesive
Florida Product
Underlayments
Approval
DAP Foam Touch 'n Seal Storm Bond Roof
Tile Adhesive
FL14506
Polystick TU Plus, Polystick TU Max
Dow TileBond'"
FL22525
Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
ICP Adhesives Polyset® AH-160
FL6332
Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR,
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
ICP Adhesives Polyset® RTA-1
FL6276
Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR,
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
Polyglass PolyLok Roof Tile Adhesive
FL17855
Polystick TU Plus or Polystick TU Max
'Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-R23
Certificate of Authorization H9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 5 of 14
\rTRINITYIERD
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR) self -adhered to:
➢ New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing
plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels
(designed and installed to meet wind loads for project).
Note: Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or
OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes.
Elastoflex G TU, Elastoflex S6 G or Elastoflex 56 G FR in hot asphalt to:
➢ ASTM D41 primed structural concrete.
Polyflex G or Polyflex G FR torch -applied to:
➢ ASTM D41 primed structural concrete.
5.6.2 Bond -to -Insulation:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered
to:
➢ ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck
DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
Polyflex G or Polyflex G FR torch -applied to:
➢ ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile
systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FBC Section 1504.3.1.
5.6.3 Bond to Mechanically Attached Base Laver:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or
Tile Pro self -adhered to:
➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base,
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base.
Polyflex G or Polyflex G FR torch -applied to:
➢ Elastobase; Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polyglass APP Base.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in
accordance with FBC Section 1504.3.1.
Exterior Research and Design, U.C. Evaluation Report P12060.02.09-R23
'Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.5259-1127
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 6 of 14
TRINITY ERD
5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment
forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-
12), Appendix A, Table 1A or FBC 1609 for (termination of design wind loads.
#1 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meeti project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR)j self -adhered.
#2 Maximum Design Pressure = -97.5 psf:
Deck: Min. 15/32-inch plywood to meet) project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
#3 Maximum Design Pressure=-105 psf:
Deck: Min. 15/32-inch plywood to meet) project requirements to satisfaction of Authority Having Jurisdiction.
Primer; WB-3000
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR', self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
#4 Maximum Design Pressure = -135 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) PG100 or ASTM D41
Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints.
Underlayment: Polystick TU P, Polystick TU Plus, �olystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR)j self -adhered.
#5 Maximum Design Pressure = -315 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap
Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#6 Maximum Design Pressure = -622.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Elastoflex G TU or Elastoflex S6 G,japplied in full mopping of hot asphalt or Polyflex G, torch -applied.
#7 Maximum Design Pressure = -30.0 psf*:
Deck: Min. 15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#8 Maximum Design Pressure = -37 5 psf*:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide sideilaps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-R23
Certificate of Authorization #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-RZ7
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 7 of 14
#9 Maximum Design Pressure = -37.5 psf*:
Deck: Min. 19/32-inch plywood to mee
Base Sheet: One (1) or two (2) layers ASTM D
Fasteners: 11 ga, x 1.25-inch long x 1-inch h,
Spacing: 6-inch o.c. at the 3-inch wide sidt
Underlayment: Elastoflex G TU or Elastoflex S6 G
#10 Maximum Design Pressure = -45 psf*:
Deck: Min. 19/32-inch plywood to mee
Base Sheet: One (1) layer ASTM D226, Type II
Fasteners: 11 ga. x 1.25-inch x 3/8-inch heat
Spacing: 4-inch o.c. at the 2-inch wide sidt
Underlayment: Polystick TU P, Polystick TU Plus,
Mule -Hide SA-APP Cap Sheet (FR
#11 Maximum Design Pressure =-45 psf*:
Deck: Min.19/32-inch plywood to mee
Base Sheet: Two (2) layers ASTM D226, Type
Fasteners: 11 ga. x 1.25-inch long x 3/8-inch
Spacing: 9-inch o.c. at the 2-inch wide sidt
Underlayment: Polystick TU P, Polystick TU Plus,
Mule -Hide SA-APP Cap Sheet (F
asphalt.
\\l TRINITY I ERD
project requirements to satisfaction of Authority Having Jurisdiction.
26, Type II felt
diameter round metal cap nails
laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
applied in full mopping of hot asphalt.
project requirements to satisfaction of Authority Having Jurisdiction,
diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
laps and 4-inch o.c. at two (2) equally spaced staggered center rows.
lolystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
self -adhered or Elastoflex G TU, applied in full mopping of hot asphalt.
project requirements to satisfaction of Authority Having Jurisdiction.
felt
head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
laps and 9-inch o.c. at two (2) equally spaced staggered center rows.
Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
, self -adhered or Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot
#12 Maximum Design Pressure = -45 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#13 Maximum Design Pressure = -52.5 psf:
I
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 2-inch wide sidb laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#14 Maximum Design Pressure = -52.5 psf:
Deck: Min.15/32-inch plywood to meta project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus; Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#15 Maximum Design Pressure = -52.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#16 Maximum Design Pressure =•-60 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows,
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-R23
Certificate ofAuthorizotion #9503 6�" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 8 of 14
\�I TRINITY I ERD
#17 Maximum Design Pressure = -60 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#18 Maximum Design Pressure = -67.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c. at the 4-inch wide side (laps and 8-inch c.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
#19 Maximum Design Pressure = -75 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners: Dekfast #14 with Dekfast Hex plates, CMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 10-inch o.c. at the 4-inch wide side laps and 10-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
#20 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#21 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet'project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: CMG #12 Standard Roofgrip or 0 I G #14 Heavy Duty with OMG 3" Round Metal Plates or CMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#22 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
#23 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APR Base (requires use of torch -applied underlayment)
Fasteners: Dekfast #14 with Dekfast Hex plates, CMG #14 HD with OMG '3" Galvalume Steel Plates, CMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners I
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied In full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
Exterior Research and Design, L-C. Evaluation Report P12060.02.09-R23
Certificate ofAuthorization #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION 151.5259-1127
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 9 of 14
TRINITY ERD
#24 Maximum Design Pressure = -97.5 psf:
Deck: Min. 19/32-inch plywood to meet) project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga, x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c. at the 4-inch wide sidel laps and 4-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#25 Maximum Design Pressure = -105 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners i
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#26 Maximum Design Pressure = -120 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap.or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Rocfgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-Inch c.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#27 Maximum Design Pressure = -120 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
5.6.4.1 All other direct -deck, adhered Polyglass u�derlayment systems beneath foam -on tile systems carry a Maximum
Design Pressure of -45 psf.
5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed
that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum.design pressures for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density
designed by a qualified design professional Ito resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked
with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January
2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days
after installation.
Polystick IR-Xe or Polystick MU-X shall not bejleft exposed for longer than 90-days after installation.
Polystick MTS, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or Elastoflex G TU shall not be left'exposed for longer than
180-days after installation.
Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30
days.
Elastoflex 56 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the
prepared roof covering is to be adhesive -set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum
exposure is 180 days.
5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226
roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as
set forth in Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-R23
Certificate of Authorization#9503 e" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 384-1230 Revislon 23: 09/14/2017
Page 10 of 14
TRINITY I ERD
5.9 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)):
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE 2: TILE SLIPPAGE dMITATIONS FOR DIRECTrDECK TILE' INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum Slope
Elastoflex G TU
Flat
10-tile stack
7:12
Lugged 11
8-tile stack (6 over 2)
6:12
Elastoflex S6 G or S6 G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polystick MTS
Flat or Lugged
Prohibited without battens
N/A
Polystick Tile Pro
Flat or Lugged
6-tile stack (4 over 2)
7:12
Polystick TU Max
Flat
6-tile stack (4 over 2) or 10-tile stack
7:12
Lugged
6-tile stack (4 over 2)
7:12
Lugged
10-tile stack
6:12
Polystick TU P
Flat
6-tile stack (4 over 2)
6:12
Lugged
6-tile stack (4 over 2)
4:12
Polystick TU Plus
Flat or Lugged
6-tile stack (4 over 2)
7:12
Flat or Lugged,
10-tile stack
6:12
Polyflex G or G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polyflex SA P or SA P FR
I Flat or Lugged
6-tile stack (4 over 2)
4:12
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Sectioj 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Elastobase, Elastobase P or Mule -Hide NaillBase:
6.3.1 Non -Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA
P FR, Mule -Hide SA-APP Cap Sheet or SAS-APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or
Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are
those associated with the top -layer underlayment, as set forth in Table 1.
6.3.2 Tile Applications:
Elastobase, Elastobase P or Mule -Hide Nal[Base are limited to use as a mechanically attached base sheet in the "Two
Ply System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.4 herein, coupled with
FRSA/TRI April 2012 (04-12) Installation Manual.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R23
Certificate ofAuthori:ation N9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FLS259-1127
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
i Page 11 of 14
\J\
TRINITY ERD
6.4 Polystick MTS, IR-Xe, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or MU-X or Polyflex SAP,'Polyflex SAPTR, Mule -Hide
SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR):
6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1507.1.1
for the type of prepared roof covering to bQ ( installed.
6.4.2 Direct -to -Deck with Mechanically Fastened Roof Covers:
All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP
Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule -
Hide Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter
metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -nailed
using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane.
The head lap membrane is to cover the area being back -nailed.
All seal -lap seams (selvage laps) must
firmly rolled with a minimum 28 lb. ha
roller to ensure full contact and adhesion.
For Dual Pro and Tile Pro, align the edge
the top sheet to the end of the glue patt(
(the sheet will overlap the fabric).
All over -fabric and over -granule end -laps s
Wet/Dry Cement or Polyglass PG500 Modi
Polystick TU Plus, Dual Pro and Tile Pro mz
or exposed roof to wall details
Repair of Polystick membranes is to be accc
Polyglass PG500 Modified Cement to the
Polystick material of like kind, set and ha
installed in a water shedding manner.
All Polystick membranes shall be installer
minimum of 40-lb weighted -roller or, on st
for the field membrane. Hand rollers are a(
roof that are not accessible to a large roller
6.4.3
View of Ovelap Seam of Dual Pro and Tile Pro
ill have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified
d Cement applied in between the application of the lap,
not be used in any exposed application such as crickets, exposed valleys,
nplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or
Irea in need of repair, followed by a minimum 6 x 6 inch patch of the
d rolled in place over the repair area. Patch laps, if needed, shall be
to ensure full contact with approved substrates. Polyglass requires a
ep slopes, use of a stiff broom with approximately 40-lbs of load applied
eptable for rolling of patches, laps (min. 28 lb roller) or small areas of the
r broom.
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base
Sheet fastening shall be not less than FRSA/ITRI April 2012 (04-12), Table 1.
For adhesive -set tile applications, refer to Section 5.6.4 herein.
For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile.
6.4.4 Two (2) Ply Underlavment Systems:
Polystick MTS followed by Polystick MTS, TU P, TU Plus, TU Max, Tile Pro, MU-X or Polyflex SAP is allowable for use
under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material.
This is not a requirement, but is allowable if'a 2-ply underlayment system is desired.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-1123
CertljlcateofAuthorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-1127
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 12 of 14
\I TRINITY
6.5 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR:
6.5.1 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be installed in compliance with current Polyglass published
installation requirements. For use in tile applications:
✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G FR is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
6.5.2 For hot -asphalt -applications, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be fully asphalt -applied to the
substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set
minimum 3 feet from course to course. Sitle and end laps shall be fully adhered in a complete mopping of hot asphalt
with asphalt extending approximately 3/8-inch beyond the lap edge.
6.6 Polyflex G or Polyflex G FR:
6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements.
For use in tile applications:
✓ Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened or adhered tile roof systems (Base Sheet Limited per 5.6.3).
✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI
April 2012 (04-12) beneath mechanically fastened tile roof systems (Base Sheet Limited per 5.6.3).
6.6.2 Polyflex G or Polyflex G FR shall be fully torch -applied to the substrates noted in Section 5.6. Side laps shall be
minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end
laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap
edge.
6_7 Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to
Table 2 herein, and Polyglass published requirements for tile staging.
6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used
on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or sail-
boards, to prevent tile sliding and/or damage to the underlayment during the loading process.
6.7.3 Polyglass specifies the minimum cure time after installation of self -adhering membranes and before loading of
roofing tiles is forty-eight (48) hours.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-R23
Certificate ojAuthorization#9503 6T" EDITION (2017) F13C NON-HVHZ EVALUATION FL5259-1127
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/24/2017
Page 13 of 14
e
��TRINI*ERD
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this. product.
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements. The following
plants have qualified products under their respective !physical properties specifications.
Plant
Specification
Product Us
Fernley, NV, Hazleton, PA & Winter Haven, FL
ASTM
ID1970
Polystick MU-X
Hazleton, PA
M-D 13-0004
Elastoflex G TU
Hazleton, PA & Winter Haven, FL
ASTM ID1970
Polystick IR-Xe
ASTM 1D1970 & TAS 103
Polystick TU Plus
ASTM ID1970 & TAS 103
Polystick TU Max
Tuscaloosa, AL
ASTM ID4601, Type II
Polyglass G2 Base
Winter Haven, FL
ASTM jD226 (physicals)
Elastobase, Elastobase P
ASTM ID6509
Polyglass APP Base
TAS 163
Polystick MTS
ASTM:D1970 & TAS 103
Polystick TU P
FRSA/TRI April 2012
Polyflex SAP, Polyflex SA P FR
ASTMID1970
Polystick Dual Pro
ASTM ID1970 & TAS 103
Polystick Tile Pro
ASTM;D6164
Elastoflex S6, Elastoflex S6 G FR
ASTM;1)6222
Polyflex G, Polyflex G FR
9. QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625; (314) 578-3406; k.chancellOr@ui.ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R23
Certificate of Authorization #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 14 of 14