HomeMy WebLinkAboutEVALUATION REPORTCREEKGGANNED Certificate of Authorization No. 29824
, �� 17520 Edinburgh Drive
ude COLAv Tampa, FL 33647
TECHNICAL SERVICES, LLC (813) 480-3421
EVALUATION REPORT I FLORIDA BUILDING CODE, 6TH EDITION (2017)
Manufacturer:
Quality Assurance:
SCOPE
TAMKO BUILDING PRODUCTS, INC. Issued October 19, 2017
P.O. Box 1404
Joplin, MO 64802
(417) 624-6644
http://www.tamko.6om
UL LLC (QUA9625)
I
Category:
Roofing
Subcategory:
Underlayments
Code Sections:
1507.1.1
Properties:
Physical properties
PRODUCT DESCRIPTION
TAMKO® ASTM Slate
ASTM D 6380, Class M, Type II underlayment constructed from organic felt saturated
Surfaced Roll Roofing
with asphalt and coated on both sides with asphalt and surfaced with granules.
TAMKO® ASTM Tile
ASTM D 6380, Class M, Type Il underlayment constructed from an organic felt saturated
Underlayment
with asphalt then coated on both sides with asphalt and surfaced with granules.
I
TAMKO® Master
ASTM D 6380, Class S, Type IV underlayment constructed from an organic felt saturated
Smooth
with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For
use in non-HVHZ only.
TAMKOO Moisture
Self -adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane
Guard®
with a mineral surfacing and a removable release film on the adhesive side and
removable selvedge release tape.
TAMKO®No. 15 ASTM
ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated
saturated with asphalt.
Organic Felt
TAMKO® No. 15 UL
ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated
saturated with asphalt.
Organic Felt
TAMKO® No. 30 UL ASTM D 226, Type II underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated saturated with a,'sphalt.
Organic Felt
TAMKOO TW Metal and Self -adhered, flexible, ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane
Tile Underlayment with a polymer film on the surface and a removable release film on the adhesive side.
TAMKOO TW Self -adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a
Underlayment polymer film on the surface and a removable release film on the adhesive side.
TBP14001.4 FL12328-R8 Page 1 of
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein. PY
FILE COO'
G R K TAMKO BUILDING PRODCUTS, INC.
TAMKO Underlayments
TECHNICAL SERVICES, LLC
TAMKO® TAM -FELT Alternate to ASTM D 226, Type I and Type II underlayment constructed from a non -
perforated organic felt that is saturated with asphalt.
APPLICATION METHOD
Installation shall be in accordance with the published manufacturer's installation, instructions, the FBC, and the
requirements below.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be
checked for protrusion and corrected prior to underlayment application.
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck
shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting
joints.
The minimum application temperature shall be 501'F except as follows:
a) The minimum application temperature of TAMKO® TW Metal and Tile Underlayment and TAMKO® TW
Underlayment shall be 40°F.
b) The minimum application temperature of TAMK06 Moisture Guard® shall be 35°F.
The minimum roof slope shall be in accordance with FBC requirements except as follows:
a) The minimum slope of TAMKOO ASTM Slate Surfaced Roll Roofing shall be 2:12.
Underlayments shall be exposed in accordance with the manufacturer's recommendations, but in no case shall
exposure exceed 30 days.
Exception: TAMKO® TW Metal and Tile Underlayment may be exposed for a maximum 90 days.
Self -adhering underlayments may be adhered tolprimed or unprimed plywood substrates in the non-HVHZ.
i
All roof coverings shall be mechanically fastened through the underlayment to the roof deck.
I
Allowable Roof Coverings:
Metal Roof,
Mineral
Wood
Asphalt
Panels and° "
Sufaced;Roli
` Shingles and
Slate'
Clay and _
Underlayment
shingles
Shingles .,
Roofing
Shakes
Shingles
Concrete Tile
TAMKO® ASTM Slate
Y'
N
N
N
N
Y
Surfaced Roll Roofing
TAMKOO ASTM Tile
N
N
N
N
N
Y
Underlayment
TAMKO® Master Smooth
Y'
N
N
N
N
N
TAMKO® Moisture Guard®
Y
N
N
N
N
N
TAMKO® No. 15 ASTM
Asphalt Saturated Organic
Y
Y
Y
Y2
N
N
Felt
TAMKO® No. 15 UL Asphalt
Y
Y
Y
Y2
Y
N
Saturated Organic Felt
TAMKO®'No(30^ASTM;,„ +--
AsphaltSaturat6d' - rganic
—�--^
Y,
Y
Y
�
Y
_� __ _ T
Y
-
Y
�It
TAIVfKO® No. 30 UL Asphalt
Y
Y
Y
N
Y
N
Saturated Organic Felt
TAMKOB TW Metal and Tile
Y
Y
N
N
N
Y
Underlayment
TAMKOO TW Underlayment
Y
Y
N
N
N
N
TAMKOO TAM -FELT
Y
N
N
N
N
N
Notes: 1) Open valley applications per 1507.2.9.2
2) Wood shingles only
TBP14001.4 FL12328-R8 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
FILE C U01% P
TAMKO BUILDING PRODCUTS, INC.
CREEKTAMKO Underlayments
TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is not within the scope;of this evaluation.
2) Wind uplift resistance in not within scopelof this evaluation.
3) Installation of the evaluated product shall, comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) Contact the manufacturer when installing at temperatures below the minimum application temperature.
5) Unless otherwise stated, the minimum roof slope shall be in accordance with FBC requirements.
6) All underlayments shall be installed with) the roll length parallel to the eave, starting at the eave, and lapped
in successive courses installed up the deck in a manner that effectively sheds water from the deck. End
laps shall be staggered between courses in accordance with the manufacturer's application instructions.
7) The underlayment may be used as described in other current FBC product approval documents.
8) The underlayment shall not be installed over existing roof coverings.
9) Contact the manufacturer regarding specific exposure limits for each underlayment.
10) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
REFERENCES
Enti
Report No.
PRI Construction Materials Technologies (TST6049) 1
TAP-192-02-01
PRI Construction Materials Technologies (TST6049) ;
TAP-193-02-01
PRI Construction Materials Technologies (TST6049)
TAP-214-02-01
PRI Construction Materials Technologies (TST6049) !
TAP-215-02-01
PRI Construction Materials Technologies (TST6049)
TAP-216-02-03
PRI Construction Materials Technologies (TST6049)
TAP-217-02-01 REV
PRI Construction Materials Technologies (TST6049)
TAP-218-02-01
PRI Construction Materials Technologies (TST6049)
TAP-219-02-01
PRI Construction Materials Technologies (TST6049)
TAP-220-02-01
PRI Construction Materials Technologies (TST6049) I
TAP-222-02-01
PRI Construction Materials Technologies (TST6049) i
TAP-245-02-01
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
UL LLC (TST9628)
I
TAP-311-02-01
TAP-319-02-01
TAP-387-02-01
TAP-388-02-01
13CA12269
Standard
ASTM D 1970
ASTM D 1970
ASTM D 4869
ASTM D 226
ASTM D 6380
ASTM D 6380
ASTM D 226
ASTM D 226
ASTM D 6380
ASTM D 4869
TAS 103
ASTM D 4798
ASTM D 1970
ACC 188
ASTM D 1970
ASTM D 1970
ASTM D 226
Year
2015a
2015a
2016
2009
2003(2013)
2003(2013)
2009
2009
2003(2013)
2016
1995
2011
2015a
2012
2015a
2015a
2009
TBP14001.4 FL12328-R8 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or; quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
FILE COPS`
CREEK TAMKO BUILDING PRODCUTS, INC.
TAMKO Underlayments
TECHNICAL. SERVICES, LLC
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 60 Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
j V1111 a i+++i
R
PaGEN'
Y F 2017.10.19
.`wpG
'V No 74021 - 12:15:58
- - q'}py�lMlm,z MYtl
-04'00'
� :. STATEi OF .:��
����`�•;°< �P: ��.` Zachary R. Priest, P.E.
i��Fss ON AL � �,,, Registration Florida 21
Organization No.ANE9641
+nnli It
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.
END OF REPORT
TBP14001.4 i FL12328-R8 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
FILE U
PY