26 Ga. GulfRibTm Roof
Florida Product
Florida Bui
Rt
(;ONCEALED I-ASTENERS OR A TACHmws Per
eMel
ARE THE RESPONSIBILITY OF THE
CONTRACTOR OF RECORD,
Subcatec
Compliance M
N
G 6 li'C'�Woa t
SUPPLY & MANUFACTURING
luation Report
� MANUFACTURING, LLC
over 15132" Plywood
pproval #11651.22 R3
ling Code 2017
e 61 G20-3 THESE PLANS AND ALL PROPOSED WORK
iod: 1 -D ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY NECESSARY IN ORDER TO
ry: Roofing COMPLY WITH ALL APPLICABLE CODES.
Metal Roofing
A 61 G20-3.005(1)(d)
V HVHZ
Product Manufacturer:
Gulf Coast Supply & Manufacturing, LLC.
`� ��''��
14429 SW 2nd Place, Suite G30
Newberry, FL 32669
��`'`�
.� N�E� S,, k �,
` • C E NSF
Engineer Evaluator:
Dan Kuhn, PE. #75519
_
Florida Evaluation ANE ID: 10743
-A-, STATE OF
•
•�?�
Val'idator:
..
'�, 6 ONA L E
Locke Bowden. P.E. #49704
" I # j t i t I " zo/o5/202�
ST. LUCIE COUNTY BUILDING D SION 9450 Alysbury Place
REVIEWED FOR MP I /1gl�tgomery, AL 36117
REVIE D Y. e:'t�
DATE -
PLANS AND PE IT MUST BE KEPT ON JOB Contents:
SITE OR NO INSPECTIONS) WILL BE MAgTvaluation Report
Pages 1 - 5
r T 1 1--
TM
Compliance Statement:
Product Description:
Panel Material/Standards:
Panel Dimension(s):
Panel Fastener:
Substrate Description:
Design Uplift Pressures:
FL# 11651.22 R3 9 OCTOBER 5, 2017
CT APPRoV Gulfc6dft
SUPPLY & MANUFACTURING
The product as described in this report has demonstrated compliance with the
Florida Building Code 2017, Sections 1504.3.2.
GulfRibTM' 3/a" Rib Roof Panel, Minimum 26 Ga. Steel, 36" Coverage,
through fastened roof panel over minimum 15/32" Plywood Decking. Non
Structural application.
Material: Minimuml26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to
Florida Building Code 2017 Section 1507.4.3.
Paint Finish Optional
Yield Strength: Mini 80.Oksi
Corrosion Resistance: Panel Material shall comply with Florida Building
Code 2017, Section) 1507.4.3.
Thickness: 0.018" Minimum
Width: 36" Coverage
Rib Height: 3/a" Major Rib at 9" O.C.
#9-15x1.5" HWH vYith sealing washing or approved equal
1/4" minimum penetration through plywood.
Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4
Minimum 15/32" thick,) APA Rated plywood over supports at maximum 24' O.C.
Design of plywood a�1d plywood supports are outside the scope of this
evaluation. Must be designed in accordance w/ Florida Building Code 2017.
Table "A"
Maximum Total UP, Design Pressure M
69 25 psf
59 25 psf � � `
Fastener Pattern I
9"-9"-9"-9"
6.5"-2.5"-6.5"-
2.5"6.5 "-2.5 "-6.5"
Fastener Pattern Spaeingri24,®
Design Pressure includes a Safety Factor = 2.0.
CT0 r nV
GuIfCdast
SUPPLY & MANUFACTURING
Code Compliance:
The product described herein has demonstrated compliance with the
Florida Building Code 2017, Sections 1504.3.2.
Evaluation Report Scope:
The product evaluation is limited to compliance with the structural wind load
requirements of thel Florida Building Code 2017, as relates to Rule 61 G20-3.
Performance Standards:
The product described herein has demonstrated compliance with:
• UL 580-06 - Test for Uplift Resistance of Roof Assemblies
• UL 1897-12 - Uplift Test for Roof Covering Systems.
Reference Data:
1. UL 580-94 / I1897-98 Uplift Test
Force Engineering & Testing, Inc. (FBC Organization # TST-5328)
ReportNo. 1IQ 7-0062T-07A, B, Dated 02/19/2007
2. Certificate of�Independence
By Dan Kuhn; P.E. (FL# 75519) @ Kuhn Engineering, LLC
(FBC Organization # ANE ID: 10743)
Test Standard Equivalence:
1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard.
2. The UL 1897-98 test standard is equivalent to the UL 1897-12 test
standard.
Quality Assurance Entity:
The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 61 G20-3.005(3) for
manufacturing under a quality assurance program audited by an approved quality
assurance entity.
Minimum Slope Range:
Minimum Slope shall co ply with Florida Building Code 2017, including
Section 1507.4.2 and inFaccordance with Manufacturers recommendations. For
slopes less than 3:12, lap sealant must be used in the panel side laps.
Installation:
Install per Manufacturer's recommended details.
Underlayment:
Shall comply with Florida I Building Code 2017 section 1507.1.1.
FL# 11651.22 R3 • OCTOBER 5, 2017
Shear Diaphragm:
Design Procedure:
Shear Diaphragm va
GuIfC®as°t
SUPPLY & MANUFACTURING
part of this acceptance.
are outside the scope of this report.
For roofs within the parameters listed on the load table, fastening pattern must
at a minimum meet those listed for the applicable wind zone. For all roofs outside
the parameters listed 'on the load table, design wind loads shall be determined
for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10
using allowable stress',design. The maximum fastener spacing listed herein shall
not be exceeded. This evaluation report is not applicable in High Velocity
Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this
product in High Velocity Hurricane Zone.
FL# 11651.22 R3 0 OCTOBER 5, 2017 PILE COPY
— Ao�"��.M\ — .
ENGINEER LOAD TABLE: 26 Ga. GulfRibTM Panel over 15/32" Plywood
Buildings having `a Roof. Mean N,otght <. 20 0 Roof; Slope }2" /12' f ,12 '/12 ! Gable -or HIp,Roof UUInd Spee`ds,Y120,
180mph; Exposure C, Risk Crategory il;°Enclosed Bulltlir g based one Fl"oritla�Bulldih QQ tle 2017
120
130!
140
ISO
160
170
180
WIIND
FASTENER
SUBSTRATE
SPEED
(MIN. 1/4
Penetration)
(MIN. 15/32")
ON CENTER
ON CENTER
ON CENTER
ON CENTER
ON CENTER
ON CENTER
ON CENTER
SPACING
SPACING
I
SPACING
SPACING
SPACING
SPACING
SPACING
ZONE 1
#9-15x1.5",
PlyVvood
24 TYPyE 1
24' TYPE i
24 TYPE 1-
;24 TYPE 1
24 „TjYP,E 1
24 TYPE1
24 TYPE 1,
ZONE 2
#9-15x1.5"
Plywood
24", TYPE 1
24", TYPE 1
•24", TYPE 1
24", TYPE 1
24", TYPE 1
24", TYPE 1
24", TYPE 2
ZONE 3
#9=15X1.5".,'
Plyvv00d
24 TYPE 1<
24' TYPE,1
24 TYPEr1
'12 TYPE 2
� f1.i�'
y12 sT>YPE`2 f
y�tfnr,n�fi,y_t
12 TYPEE2�
12 RYPE 2•"
1.) PANEL DESCRIPTION: GULFRIBTNI, MIN. 26 GA., GRADE 80, 36' COVERAGE, 3/4" TALL.
2.) PANEL FASTENER: #9-15X1.5" HWH WITH SEALING WASHER OR APPROVED EQUAL
3.) MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE: 69.25 PSF @ 24" O.C. FASTENER SPACING TYPE I FASTENER PATTERN, 159.25
PSF @ 12" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING.
4.) PLYWOOD DECKING: MIN. 15h2" THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017.
5.) ROOF SLOPE: ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT*ST BE USED IN PANEL SIDE LAPS.
6.) LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10 (KID = 0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING
CODE 2017.
1LUNt L -"-- --- -"
ZONE 3
-----------------
-RIDGE
I
ZONE 1
\\ \\\
//-----------------\\
Note: Dimension (a) is defined as 10% of the minimum width of the building or
40% of the mean height of the roof, whichever is smaller, however, (a) cannot be
=�a less than either 4% of the minimum width of the building or 3 feet.
I
TYPE 1 FASTENER PATTERN
-t�9. i 91 Panel Lap'
ZONE
^ 2—— GABLE ROOF TaT
-- — —— — — -
- — — _ �a
I— I
I I
RIDGE
----- --------------�-
_]a
------------------------+ a
ZONE 1
I�-----------------------1I-
"ZONE 3 HEAVE
FL# 11651.22 R3 0 OCTOBER 5, 2017
Cont: Tape Seal for use on Slopes less than
#9-15 x 1-1/2' w/Sealer Washer @ 24.O.C. Max
Cont: Tape Seal for use on Slopes less than
#9-15 x 1-1/2' w/Sealer Washer @ 12.O.C. Max.
GTI P C P "yf