Loading...
HomeMy WebLinkAboutSWIMING POOL PLAN4 �n r of repose criteria for St..Lucie Cow 1) #3 re -steel @ 6"• OC/BW, • and 2) l POOL SECTION. I j r4-ETE TILEnLE 1 PROWT I-1Ql? WAL 'To.. _ P L 6� G,� FI FR-� � e00L fnmu. =1CTOU-R) ALSO RF5po- 05 f OLE FOR STROC)TUIZAL _ wvF-C,wT`/, EL SIn E t�l(-►IN . IIJC�_. eEzAk NoVO :-- - - - - fi � / StLude �►!�9 J ST. LLTCE COUNTY BurLD_ _ ION REVLEIVED FOR COAL pp REVIEWS BY - DATE 4101 IO Width: .................. 8' 6" / 2.59 M PLANS AND PERMIT MU9 BE KEPT ON JOB Length:................ 40' / 12.19 M OR NO INSPEOT'ICW WILL BE MADE. Depth: ................. 4'9"/ 1.45 M Area: .................. 282 ftz / 26 MZ Volume: ............8,500 G / 32,176 L THESE PLANS ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS y REQUIRED BY FIELD INSPECTORS THAT MAY SE NE0166ANY IN ORDER TO ti � COMPLY W1Tt11 Aid AAPWAPIA googol CONCFALED FASTENERS OR ATTACHMENTS. -FILE C'm PNf ARE THE RESPONSIBILITY OF THE v CONTRACTOR OF RECORD I only, for pool - 5 from house hickness - 6" min ... w/0 N14-11 - F NT(ZAPMEUT till) 33' D11N BRICK :rr��rr=«i� TILE 4" CONCRETE CANTI-LEVER LhRe.l.F_ CONCRETE L% OVER -POUR WALL SE 5/8" OR BETTER PLYWOOD SHEATHING 2"x 4"x 8' ® 2' O.C. 7.-2'--T SHORING • -DETAIL BRICK IN SAND 4" CONCRETE �- PROTECTIVE MUD WORK 1 FLUSH WITH BULLNOSE TILE SWIMMING- POOL PLAN - SCALE: 1 /. 8"=1'-0" APR - f 2018 .n 0 SID KOaVNER IS.E: #16668 Ti .SCREEN ENCLOSURE, SWIMMING / IMI1 Y V PO`�\Eap�\ �O�A�////.�, ENGINEERING (BY OTHERS VV •Yr PLAN F'OI-� • ;'\ 5,'�-', BRICK PAYERS � ` n (�`�''�/j NO. 16 V/f FlNISH GRADE �1 *��� ®� P'0 !'` 1 ! ` 5 r i N.T.S. 93d I10PIAN RIVES STATE OF •• " ' B'x B•x 1B' U-BLOCK • s i 1-#5 REBAR CONT. ), OR PRECAST LINTEL FlLLED SOl1D 2500 PSI CONCRETE W/6"x 6" WITH CONCRETE 3000 PSI 0 28 DAIS F®�� Ql�fy% (" ��s ��C`�OR1�P��G����� # 10/10 STEEL WIRE MESH OR t'`l� FIBER MESH, (11b/'YD' ) �0 0-0 '�0 3—#3 REM 8" FOOTER . DETAIL fa r NCLOWRE SWIM IN BENCH DETAIL NTS / S/ONA%- E��\�� DISIRUBED saL EL-SID E1VtGINEERING RECEjVED #EB-0006831 2'!; 139 ISLE VERDE WAY 9 ,7018 o� PALMBEA'CH GARDENS, Fffl (� ➢ e County Permitting PULL For UNDISTURBED SOIL' ,NO ExC InONS) DRAWNBE SHEET] OF SWIM OUT BENCH DETAIL I '� JOB NO: MV1 100 I utc PIPING SCHEMATIC Nrs IORS WATER I � TO LEVEL 6"MIN-12"MAX H/W VAC LOCK #LW400 FBC 201 SEC 424.2.6.6.2 & ANSI/ SME A112.19.8M SKIMMER & VAC DETAI 3—TREAD LADDER TI RENRV lb POOL 1/ I.� POOL 6RAWH PLPI '^�, '� - �' 6 PIPE SIZE FLOW (ft/sec) FLOW THR �rtiVI IXMD GRATES $ PIPE FLOW MAIN DRAIN ,� 211 �.`I SKIMMER 2'I RETURN TO POOL/ SPA___.... ��. ...'...._��`'� iQ .....__........ ASSUMPTIONS: POOL FLOW 67% MD 33%D SKIMMER SPA FLOW 100% MD POOL RETURN 1! FROM PUMP, r FROM TEE 1 z" Ift lR1 LE- T PIPING DIAGRAM . ; 'NOTES.`' N.T.S. • TESTED IN COMPLIANCE*"TH FLORIDA BUILDING LOGE 424:29.8 SUCTION ENTRAPMMT AWDSPHERIC :. _.._::.__.—.---..._......_.._ _ _... VENT TEST PROTOCOL. APPROVED SWIMMING POOL SPA AND WADING POOL • THE MAMMUM VACUUM N1TH ONE SUMP PLUGGED AND A CODY ENTRAPMENT ON THE OTHER SUMP NEVER EXCEEDS C6 INCHES OF MERCURY. T (S) COMPLAINT WITH 424.2.6.6 OF 7HE FLORIDA BUILDING CODE ENTRAPMENT Rn>:ASE IN LESS 1HAN TNREE (3) SECONDS a D(A 3 A'011A • ALL SUCTON PIPING TO BE 2'„LN MINI UM' • .1t-D• :�• • MA)OMUM SUCTION PIPE'VtLOCITY SIX (0) FEET PER SECOND. MINIMUM ASME//ANSI A112.19.BM19B7 US CRATES 8171L' f ® (ALE) MATCNINO MAIN DRAIN SUMPS. 2 PLACES) (PUMP. FRAME & FILTER TANK MOUNT & HEATER 1 3/4"x 3/16" TAP CON. 1N OPW FLow ���NG_ FLpoQ.1'Lll N SIICIION PIPING PUMP to j .. i HANDRAIL & STEPS 1240—srn-Nv_ A,11A11 OR EQUIVALENT ANCHOR REINFORCED CONC. SLAB OR CONIC. PAVERS i# POOL EQUIPMENT 'AP MAIN DRAIN DETAI p� i j2018 �2 AVJ$1 jAQ% N,, .%1 KoRN iili Q , No. 16668 STATE OF � '0��`Ss'c�0_ SID KOVNEI #EB=00068 1� 139ISLE VERDE WAY PA �I I LM BEACH GARDENS, FL 33418 For J E DRAWNBY.• SHEET 2 OF 3 P.E.- #16 NOTES: ONE OF'7HE FOLLOWING POOL SAFETY FEAIUpE'OPITONS MUST BE PROVIDED: 1. THE POOL MUST BE ISOLATED FROM ACCESS TO A HOME BY AN ENCLOSURE THAT MEETS THE POOL BARRIER REQUIREMENTS OF4%2.17 OF THE FLORIDA BUILDING CODE. 2. THE POOL MUST BE EQUIPPED WITH AN APPROVED SAFETY POOL COVER. 3. ALL DOORS AND WINDOWS - PROVIDING DIRECT ACCESS FROM THE HOME TO THE POOL MUST BE EQUIPPED WITH AN EXIT ALARM THAT HAS A MINIMUM SOUND PRESSURE RATING OF 85db A AT 10 FEET OR, 4. ALL DOORS PROVIDING DIRECT ACCESS FROM THE HOME TO 7HE POOL MUST -BE EQUIPPED WITH A.SELF- CLOSING, SELF -LATCHING DEVICE WITH A RELEASE MECHANISM PLACED NO LOWER THAN 54 INCHES ABOVE THE FLOOR N111JIN►UM FLAW %Ar fo uQ . WP,NOVER I 1aPM P_ MI MIN�MUr1_..Frlt`TER..f��rrA� GA.RTRI DGE. (01. FTI < JOD FT1< PF2 ......... P < `H LTER PUMP WRVE _ J41w.._S.-.Zo.-------- 51ift._..... - - - EMECI RIC R15ER fli FlCRAM 200 , I ' _P(ol POOL e Ila • PML P 1XL FPL 2 qO r �'$ N • EQUIPOTENTIAL BONDING GRID NEC 680.26 (c) 20-I4 Alternative Method per FL Senate Bill SR 2836 Executive Order 2007-187 signed June 19, 2007 FB.0 101.2.1 SPECIFICATIONS: gg� 7A61 k 244' C * tml R !A' ,10 1. THESE ENGINEERING PLAX CO ��t WITH F$C 261 C. 454.9 PRIVATE SWIMMING POOL . FBC 201.'6EC. 4 y01. ENGINEERING DESIGN, CONSTRUCTION AND WORKMANSHIP ANSYNSPI 4-92 & NSPI -5. 101.2.1 FIN$1/P►PS.P- 1.517 2. CONCRETE TO ATTAIN 3000 PSI @ 28 DAYS. AN S 1/ N$ P ( - • 3, 4451/ASPCI ICC - 4151(o 4. PIPING & PLUMBING TO BE SCH. 40 & 80 PVC PIPE TO CONFORM TO NSF STANDARDS & FBC 4542.3, 2.13.2 • PURPLE PRIMER APPLIED P RIOR TO ALL GLUE JOINTS FBC PLUMBING SEC. 6.05.21 WATER PLUMBING PRESSURE 35 PSI FOR 15 MINUTES (NO AIR PRESSURE) SEC. 4S42.12:1. 5. ALIWMMff WiL, LITES, LADDERS & HANDRAILS BONDED W / #8 GROUND WIRE TO NEC. # 680./Z,O( q 6. SOIL.STATEMEMENT: SWIMMING POOL / SPA / PATIO - SSE Go(L S"[pi �Pr►` 7. POOL / SPA SURROUNDED BY SCREEN ENCLOSURE OR 4' FENCE WITH SELF -CLOSING GATES. HOUSE SAFETY BARRIER TO BE "THE BABY" FENCE OR ALARM SYSTEM PER CODE (BY OTHERS). 8. POOL / SPA HEATER INSTALLAT ION TO FBC. 2.14.1 HEATER TO HAVE THERMOSTAT AND HIGH PRESSURE CONTROL TO LIMIT WATER TEMPERATURE TO .5104 ° F. FBC. SEC. 4wA.2.14.4. 9. ALL GAS PAPING TO FBC. FUEL GAS SEC. 24.2.25 / ALL ELECTIRCAL TO NEC. # 680.12014 10. AFTER COMPLETION, THETOOL [SPA MUST NEVER BE DRAINED BY THE HOME OWNER FOR ANY REASON WHAT -SO- EVER. A LICENSED POOL CONTRACTOR MUST BE CONSULTED TO ACCOMPLISH THIS. HYDRO -STATIC RELIEF VALVE IS USED AT ENGINEER'S DISCRETION ONLY. BACK FLOW PREVENTER ON WATER SERVICE (WPB QNLY 11. THE POOL / SPA -EQUIPMENT SHALL BE SECURED TO A SUBSTANTIAL PAD SO AS TO ELIMNINATE STRAIN ON PIPING. . 12. TYPE 'O' POOL WALLS VERTICAL WITHIN 1 I °, DRAINAGE POOL / PATIO TO GRASS (PBC). 13. EL-SID ENGINEERING ASSUMES NO RESPONSIBILITY FOR POOL CONSTRUCTION IN EASEMENTS, OR REQUIRED SETBACK AREAS. THE POOL CONTRACTOR SHALL VERIFY ALL LAYOUT DIMENSIONS•IN FIELD WITH HOUSE AND LOT LINES PRIOR TO. CONSTRUCTION; ADDITIONALLY, UNDER AND OVER GROUND UTILITIES AT SITE. WATER EDGE SHALL BE 10' MIN. (HORIZONTAL) FROM OVER HEAD ELECTRIC LINES. 14. THIS ENGINEERING PLAN REMAINS THE SOLE PROPERTY OF EL -SID ENGINEERING AND IS NON -TRANSFERRABLE TO ANYONE WITHOUT EXPRESS PERMISSION OF THIS ENGINEER. 15. WARRANTY: THIS ENGINEER WARRENTS THE SERVICES PERFORMED BY EL SID ENGINEERING ARE CONDUCTED -IN A MANNER CONSISTENT WITH THAT LEVEL OF CARE AND SKILL ORDINARILY EXERCISED BY MEMBERS OF THIS PROFESSION CURRENTLY PRACTICING UNDER SIMILAR CONDITIONS. NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE MADE. POOL DATA & EQUIPMENT & CRITERIA: I � p POOL DIMENSIONS . 7 2-1"1'X 33 1- 111 AREA 2����PERIMETER O DEPTH VARIATION tI VOLUME 6500 GALLONS plme Single #8 AWG bare solid copper wire around entire perimeter of pool N* "Now ping howl lils lq"K4�iO Grade --^- for paver or concrete deck EQUIPOTENTIAL BONDING ' #8 solid ground wire shall be positioned 4" to 6" Into subgrade material of decking adjacent to Pool structure. Where decking exist. This #8 wire shall be placed 1811 to 2411 in proximity to pool structural wall. SPA DIMENSIONS RAISED W/ JACUZZI JETS GLASS BLOCK / MARBLE SPILLWAY / a7�5W -12V LrrE 1 POOL / SPA PUMP frt 1p 1 314 ' Y .� V I FILTER � �) C - r 0 PUMP HP '14. GPM flA)t 4( TURNOVER RATE HRS. LTTES (' i,I 1" WATTS HEATER BTU FUEL HANDRAIL TAMER/ SWIM -OUT-W 2 SLIDE DIVING BOARD AUTO -VAC CLEANER INLINE CL2. SHEAR DESCENT WATER FALL LIONS HEAD / ROSETTE PATIO MATERIAL W /DOD SCREEN ENCLOSURE FENCE P N �� ttllllllllll� _© N m ' Q �i :f.L�•. 4 0, aAL4l .4 P14 IPE REDUCED TO 1" 'AND RUN TO DECK Eox LED L1CH .2" BCH 40 PVC SLEEVE 10-22 WALL NG - OR EQUAL LED INSIDE PIPE - - 'LED LIGHT D ELECTRICAL DIAGRAM 30 AMP POOL PANEL W/ - NTS 3 - #10 TfM CU WITHIN MANUAL MOTOR STARTER SWITCH y" MIN. ELEC, CONDUIT • RP PUMP MOTOR w/ BUILT-IN OVERLOAD SWITCH W/ 3 - 012 THHN #8 SOLID CV GROUND WIRE Cu WITHIN y11 MIN. CONVIVIT TO EXIST. PANEL (GFCI PROTECTED) S,P.8 T. TOGGLTr- IME CLOCK SWITCH J � -P,DISCONNECT POOL LIGHTS 12 VOLT TRANSFORMER (GFI NOT REQUIRED) JUNCTION BOX 3. ALLELECTRICALTO COMPLY WffR2011 NATIONAL ELECTRIC CODE, ELECTRICAL CONTRACTOR TO VERIFY ADEQUATE CAPACITY AT POINT OF CONNECTION. Z. 3-#12 THHN CU WIT13W W" MIN, CONDUIT FOR POOL LIGHT(S), 3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC. w/ #a SOLID, EARS COPPER. C PROVIDE W.P.G.F.L OUTLET 10, MIN. - 30' MAX. FROM WATER'S EDGTi, 5. ALL POOL PUMPS TO n E larCif pRn9wi-rwn ecn w.e ., ._,... Q Install in Skimmer. • Using proper sized plastic bushings, PoolBond can be Installed In one of the threaded skimmer autiel Paris. See'Assembly Procedure• for proper tightening of PoolBond. Install in a return line: ■ PoolBond can be Installed In the filtration return line adjacent to Inlet Al ng. Avoid Instollaliona that could trap eh. • If access Is required for service purposes, e sprinkler r� system valve box can be used for amass.zu- Do No hstallasdvNn I Tmpped E&WT Pevad proper°ontad 1;water 0 Install on suction side adjacent to equipment pad: R P-P Flll.r • Install an cuctlon side plumbing at least 3' below wafer level. • It access Is required for service purposes, a sprinkler system valve box can be used. c.ncrd. 614 _ _ - ednwNhiaL.v.l #B Solid Copper Bonding CORD split Boll `�� r7�� ��CBNSF• � �/ NO.16668 r �= e'0 ��STATE OF 114J Z. , :a . AL PoolBond CaeBn II 1 Inch Male Pipe Thread APR Ig no SID KOVNER&IX.E. #16668 EL-SID ENGINEERING #EB-0006831 139ISLE VERDE WAY PALM BEACH GARDENS, FL 33418 For n