HomeMy WebLinkAboutPOOL PATION - SPAPATIO POOLS I SPAS
WALL SECTION
8'
N a „ „ 8'-10„
6 -1 6'-10" 8 O 8 -1
a 7,_3„
a
c::D: U I LN
1�2L I
SEDONA - 675 PARADISE - 090 FORT MYERS - 075 COVE - 6SQ HAVEN - 60CT LIDO - 7SQ ISLE - 8RD DIAMOND - 8DIA GRANDE - 80CT SARASOTA - 9R
INSIDE DIM: 8'-0"x14'-O" INSIDE DIM: 9'-11"x14'-9" INSIDE DIM: 7'x15' WEIGHT: 225 LBS WEIGHT: 310 LBS WEIGHT: LBS
DEPTH: 3'-6" DEPTH: 3'-8", 4'-6" DEPTH: 4'-0" AREA: 26 SO FT WEIGHT: 0 S LBS AREA: 52.5 SO FT WEIGHT: 9 S LBS AREA; 42 Ba FT WEIGHT: 4 S LBS WEIGHT: 4 S LBS
AREA: 30 SO FT AREA: 39 SO FT FT
AREA: 44 SO FT AREA: 54 SO FT
VOLUME: 2,750 GAL. VOLUME: 2950 GAL. VOLUME: 2650 GAL. PERIMETER: 21 FT PERIMETER: 29.5 FT PERIMETER: GAL
PERIMETER; 20 FT PERIMETER: 24 FT VOLUME: 450 GAL PERIMETER: 24 FT PERIMETER; 26 FT
AREA: 98 SQ.FEET AREA: 107 SQ.FEET AREA: 95 SQ.FEET VOLUME: 300 GAL VOLUME: 350 GAL VOLUME: 400 GAL VOLUME: 500 GAL VOLUME: 550 GAL VOLUME: 750 GAL
PERIMETER: 39 LIN.FEET PERIMETER: 40 LIN.FEET PERIMETER: 38 LIN.FEET
GROUND LEVEL r 3'-7"
31
10'-6"
12'
10'-3"
10' g
7' 8'
D
CHAMPAGNE - 747 MARGARITA - 746 ROYALE lOK NASSAU - lOKL CHARLOTTE - 12K
WEIGHT: L13S WEIGHT: LBS WEIGHT: 320 LBS WEIGHT: 360 LBS WEIGHT: LBS
AREA: 79 SO FT AREA: 64 SO FT AREA: 43 SO FT AREA: 51 SO FT AREA: 85 SO FT
PERIMETER: 28 FT PERIMETER: 36 FT PERIMETER: 26 FT PERIMETER: 28 FT PERIMETER: 30 FT
VOLUME: 880 GAL VOLUME: 700 GAL VOLUME: 700 GAL VOLUME: 750 GAL VOLUME: 950 GAL
LAKESIDE - 085 CRYSTAL SPRINGS - 105 CRYSTAL REEF - 727
INSIDE DIM: 8'-3"xi6'-3" INSIDE DIM: 10'-3"xi6'-3" INSIDE DIM: 12'-8"x16'-4" I I 3'-1"
DEPTH: 4'-4" DEPTH: 4'-2" 5'-0" DEPTH: 5'-2" I---� r---I T-10" 4, 3'-5"----t--- t-
VOLUME: 119 GAL. VOLUME: 119 GAL. VOLUME: 4300 GAL. -r( —�
AREA: 119 N.FEET AREA: 45' SQ.FEET AREA: 147 LIN.FEET
PERIMETER: 42 LIN.FEET PERIMETER: 45' LIN.FEET PERIMETER: 46 LIN.FEET
20'-1 "
18'-2"
13'-5"
10" 11'
MONTREAL - 730 VANCOUVER - 734 SYDNEY - 740
WEIGHT: 750 LBS
WEIGHT: LBS AREA: 120 SO FT WEIGHT: LBS
AREA: 99 SQ FT PERIMETER: 46 FT AREA: 151 SO FT
PERIMETER: 39 FT CRYSTAL BEACH - 728 CYBERLANE - 751 CRYSTAL COVE - 729 VOLUME: 2100 GAL VOLUME: 2050 GAL PERIMETER: 50 FTVOLUME: 3550 GAL
INSIDE DIM: 12'-8"x16'-4" INSIDE DIM: 8'-6"x17' INSIDE DIM: 10'-11"x17'-11"
DEPTH: 5'-2" DEPTH: 4'-9" DEPTH: 5'-0"
VOLUME: 4000 GAL. VOLUME: 3400 GAL. VOLUME: 3300 GAL. r----�`
AREA: 147 SQ.FEET AREA: 120 SQ.FEET AREA: 141 SQ.FEET 3'-9" 3'-9"
PERIMETER: 46 LIN.FEET PERIMETER: 51 LIN.FEET PERIMETER: 47 LIN.FEET 3'-4"
DECKS
14'-4"
� Ltik
`iJ:1 t":!
WALL SECTION {'
FILE COPY
16'-0"
N
NOTES:
POOL/SPA DESIGN CONFORMS TO THE FOLLOWING:
ANSI/NSPI-3, 5, 7, 15
IAPMO REPORT ER 0298
CANYON LAKE — 160 CYBERLANE - 750 2017 FLORIDA BUILDING CODE REV DESCRIPTION DATE APRV
INSIDE DIM: 10'-0"x19'-0" INSIDE DIM: 7'-6"x22' 2017 RESIDENTIAL FLORIDA BUILDING CODE
DEPTH: 3'-6" DEPTH: 4'-9" 2017 INTERNATIONAL PLUMBING CODE
VOLUME: 3,500 GAL. VOLUME: 4240 GAL. FUN DECK — 444 2014 NATIONAL ELECTRICAL CODE
AREA: 144 SQ.FEET - AREA: 159 SQ.FEET 2017 MECHANICAL CODE AECC/SAN JUAN POOLS
PERIMETER: 54 LIN.FEET - PERIMETER: 70 LIN.FEET WEIGHT: 1000 LES 2017 FLORIDA POOL & SPA CODE
AREA: 172 SO FT
r PERIMETER: 56 Fr RECEIVED BY: AMERICAN ENVIRONMENTAL CONTAINER CORP. seaaed By
VOLUME : 1435GAL 2302 LASSO LANE Steven W. Schaub
--- LAKELAND, FLORIDA 33801 State of Florida
GROUND LEVEL --- 1, 6 APR 19 2018
(863) 666-3020 License No.: 60509
i r—J3'-4" ST. Lucre county, Permitting
I` 1 Date Checked Py ffO343:1:8
MAY 2016 KVT
14 d 3 a o Title sheet
q PATIO POOLS / SPAS / DECKS 1 of 2
GENERAL CONSTRUCTION NOTES:-
-Spa installation shall be by a qualified and licensed (approved by
local building department and San Juan pools) pool contractor. The
installation shall conform to all state and local building codes, as
well as tenants of any association with Jurisdiction.
2) —This drawing is prepared for below ground installation on level sites only.
For partially or completely above ground installation, sloping sites, near
foundations or other special circumstrances, other engineering analysis
and details are required.
3) —Water supply and disposal shall be so arranged that there is no
cross connection with domestic service.
4) —Main drain cover to be certified as complient with ANSI/ASME
A112.19.8M-1987 securely fastened in place.
5) —Filtration systems, components and equipment shall comply with the latest
revision of ANSI/APSP-7 2009.
6) —Entire spa water capacity shall have designed turn over capacity of
at least once per hour, based on the manufacturer's specified rate of the filter
in a clean media condition of the filter.
7) —All electric shall conform to N.E.C. No overhead high tension wires shall pass
within 20 feet of spa or feed wires within 10 feet of spa.
8) — Concrete shall be 2500 psi at 28 days. Spa bottom to be placed in
4" Min. of sand or 3/8" max. dia. stone. Conc. Slab to have 6x6, #10/1Owwm
suspended in concrete and #8 solid copper.
9) —Install 12 volt light. When allowed by local code. Higher voltage shall be GFI
protected per NEC. At Installers option LED or Fiberoptic Lighting may be used.
1 0) — Supports and steps shall be properly reinforced and of sufficient
structural strength to safely carry all anticipated loads.
11) —AII pipe to be PVC schedule40 suitable for potable water or equivalent,
or per local code.
12) —Max. velocity in pressure piping to be 8' per second.
13) —Max. velocity in suction piping to be 6' per second.
14) —A disconnect switch shall be accessible, located within sight of spa and
shall be located at least five feet (5') horizontally from the inside walls
of the spa.
Typical properties of a REINFORCED FIBERGLASS spar
Barcol hardness of 30 mil gel coat
Glass content by weight
Tensile strength, PSI at 77 F
Tensile elongation
Flexural strength, PSI at 77 F
Flexural modulus, PSI x 10 at 77 F
Izod Impact FT—LBS/Inch of notch
Compressive strength, PSI
Typical thickness inches
7 1/4" MIN
18"
env 9 7/8"
42"
FIBERGLASS SHELL
40 — 50
27%
19,500
1 — 2%
23,800 — 27,600
0.72 — 0.77
5.9
25,000 to 38,000
3/8"
FIBERGLASS SHELL SHALL HAVE
MIN. 5/8" THICKNESS ® ABOVE
GROUND RETAINING POTION
OF SHELL
2x2 WOOD STRUTS
(3) STRUTS ON LONG SIDES
(2) STRUTS ON SHORT SIDES
CONC. FOOTING (TURNDOWN)
& SLAB W/ 2 #4 REBAR
PAVERS
PER FT MIN
SAND BACKFILL
6" MIN NOTE: APPLIES TO SEDONA POOL
(12" MIN FOR & CANYON LAKE POOL ONLY
EXPANSIVE SOILS)
RAISED BEAM WALL SECTION
NOT TO SCALE
FILTER
c
BIBE
N
SKIMMER
2 MAIN DRAINS OPTION
NTS
NOTES:
(1) AT LEAST ONE RETURN LINE IS REQUIRED FOR EVERY 300 SQ. FT. OF SURFACE AREA.
MINIMUM SEPARATION OF LINES ENTERING SPA.
(2) SUMP LINE (WHEN REQ'D) TO BE 2" SCH. 40 PVC FROM 4 CUBIC FOOT GRAVEL BED BENEATH MAIN DRAIN
TO 18" FROM EQUIPMENT.
(3) MAIN DRAIN LOCATED NEAR DEEPEST PART OF THE SPA ON WALL 4" TO 6" OFF FLOOR.
(4) SPA MUST HAVE MAIN DRAIN MINIMUM 3'—O" APART OR SEPARATED ON DIFFERENT PLANES.
(5) MAIN DRAINS MUST BE PLUMBED TOGETHER WITH A COMMON LINE TO THE PUMP.
MAIN DRAINS CAN NOT BE VALVED SEPARATELY.
3' MIN.
OPTIONAL COATING
I
W DECK W/ 8X810X10 WIRE MESH
OR F118113WESH 2500 P81 CONCRETE MN
1- 11 SOLD COPPER BOND AROUND ENTIRE
PERIMETER 18' TO 24' FROM WATERS ®OE
1
SLOPE ATI 1/4' PER FOOT
GRADE
LB_ �FOOTER AS REQ'D
1—#5 CONT. or
2—#3 CONT.
PLACE CONCRETE DECK ABOVE AND
BELOW POOL WALL LIP W/ 45' SHOVEL CUT
1'
CLEAN COMPACTED FILL
ELECTRIC
PANEL
MANUAL MOTOR
STARTER SWITCH
NO. 12 !,,IN , THW BOND WIRE
TIME CLOCK
12 MIN. THW BOND WIRE
12 IN 3/4" SCH 40 PVC
AREA
ELECTRICAL DIAGRAM
NTS
NOTES:
(1) GROUND ALL BOXES, MOTERS, GRAB RAILS, METAL WALLS, ETC.
WITH NO. 8 SOLID BOND WIRED.
(2) WATERPROOF DISCONNECT SHALL BE ACCESSIBLE, LOCATED WITHIN SIGHT OF THE SPA AND SHALL
BE AT LEAST 5 FT HORIZONTALLY FROM THE INSIDE WALLS OF THE SPA.
(3) SPA LIGHT TO BE GFI PROTECTED WITH 12V TRANSFORMER TO LOW
VOLTAGE LIGHTING.
3-1/2" HAND HOLD EDGE POURED IN PLACE WITH DECK
WALIL To ECTIONSCALE
WATER LINE
L-6-1 /2"
OPTIONAL 6" TILE
WHITE OR LIGHT PASTEL OR IRRIDUM COLORS
MANUFACTURER STIFFENED AND
REINFORCED FIBER GLASS SPA
0
LIP ~
POOL DEC,
4" DECK W/ 6X6 1OX10 WIRE MESH T�
OR FIBERMESH 2500 PSI CONCRETE MIN
1—#8 SOLID COPPER BOND AROUND ENTIRE
PERIMETER 18" TO 24" FROM WATERS EDGE
PLACE CONCRETE DECK ABOVE AND
BELOW POOL 45' SHOVEL CUT
VENT
FILTER
SKIMMER
SEE NOTE
0-10OPSl
PRESSURE TO POOL
GAUGE
SCH 40 PVC
1 1/2" DIA REQ'D
RECIRCULATION PUMP
W HAIR & LINT
S AINER
SVRS OPTION
NTS
MAIN DRAIN
ti
RETURN LINES
SCH 40 PVC
SVRS
NOTES:
(1) AT LEAST ONE RETURN LINE IS REQUIRED FCR EVERY 300 SQ. FT. OF SURFACE AREA.
MINIMUM SEPARATION OF LINES ENTERING SPA SHALL BE 10 FT.
(2) SUMP LINE (WHEN REQ'D) TO BE 6" SUMPLINE 2" MIN. SCH. 40 PVC FROM 4 CUBIC FOOT
GRAVEL BED BENEATH MAIN DRAIN TO 18" FROM EQUIPMENT.
(3) MAIN DRAINS MUST BE PLUMBED TOGETHER WITH A COMMON LINE TO THE PUMP.
MAIN DRAINS CAN NOT BE VALVED SEPARATELY.
WATER LINE
0-10OPS1
PRESSURE
GAUGE
VENT
FILTER —
HOSE
BIBB
RECIRCULATION PUMP
W HAIR & LINT
S AINER
low"
TO POOL
RETURN LINES
SEE NOTE '1'
SCH 40 PVC
1 1/2" DIA REQ'D
NON —MAIN DRAIN OPTION
NTS
SKIMMER
NOTES:
(1) RETURN INLETS AND SUCTION OUTLETS SHALL BE PROVIDED AND ARRANGED TO PROVIDE A UNIFORM
CIRCULATION OF WATER AND MAINTAIN A UNIFORM SANITIZER RESIDUAL THROUGHOUT THE ENTIRE SPA.
OPTIONAL 6" TILE
_IBERGLASS REINFORCED SPA SHELL
ALTERNATE COPING DETAIL
NOT TO SCALE
NOTES:
POOL DESIGN CONFORMS TO THE FOLLOWING:
ANSI/NSPI-3, 5, 7, 15
IAPMO REPORT ER 0298
2017 FLORIDA BUILDING CODE
2017 RESIDENTIAL FLORIDA BUILDING CODE
2017 INTERNATIONAL PLUMBING CODE
2014 NATIONAL ELECTRICAL CODE
2017 MECHANICAL CODE
2017 FLORIDA POOL & SPA CODE
SCANNED = _
BY
Sftudeftntv