N' Florida Building Code Online
Y
Product Approval Method sftcli CountyMethod 1 Option D
Date Submitted
10/20/2017
Date Validated
10/20/2017
Date Pending FBC Approval
10/26/2017
Date Approved
12/12/2017
Summary of Prndur_tc
r
ERECEIVE—D—
MAR18
rm
iting
Model, Number or Name
Description
V24212-1.tl
D namic Metals 1" Nailstrip (26 Ga
1" Nailstrip, 26 Ga Galvaluine Steel, Non-structural roof panel
Steeof
Use
I
Installation Instructions
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A I
Design Pressure: +N/A/-131.0
Other: Maximum fastener spacing 6" o/c
FL24221, RO Il 17-296 10 DW__yC pd
Verified By: Pedro De Figueiredo, P.E. 52609
Created by Independent Third Party: Yes
Evaluation Reports
FL24221 RO AE R17-296 10.pdf
I
Created by Independent Third Party; Yes
24221.2
Dynamic Metals 1-1/2" Mechanical
(Aluminum)
1-1/2" Mechanical Seam, 0.032" Aluminum, Non-structural
roof panel
Limits of Use I
Installation Instructions
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A I
Design Pressure. +N/A/-198.5
Other; -198.5 psf at maximum clip spacing 10-1/2" o/c
-179.8 psf at maximum clip spicing 13" o/c
FP4221 RO II 17-296.02 DWG.pf
Verified By: Pedro De Figueiredo, P.E. 57-609
Created by Independent Third Party: Yes
Evaluation Reports
FL24221 RO AE R17-296 2,odf
Created by Independent Third Party: Yes
24221.3
Dyn4m(c Metals 1-112" Mechanical
(24 9a Steel)
1-1/2" Mechanical Seam, 24 Gauge Galvalume Steel, Non-
structural roof panel
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
I
Approved for use outside HVHZ: Yes
Impact Resistant: N/A I
Design Pressure: +N/A/-17I1.0
FL24221 RO II 17-296.04 D-WG.pdf
Verified By: Pedro De Figueiredo, P.E. 52609
Created by Independent Third Party: Yes
Evaluation Reports
Other: Maximum clip spacing 13" o/c.
F174221 RO AE RIZ-226 4.pdf
r
Created by Independent Third Party: Yes
24221.4
Dynamic Metals 171/2" Mechanical
(26 Ga Steel)
1-1/2" Mechanical Seam, 26 Gauge Galvalume Steel, Non-
structural roof panel
Limits of Use I
Installation Instructions
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A I
Design Pressure: +N/A/i221.0
FL24221 RO IF 17-296.05 DWG,pdf
Verified By: Pedro De Figueiredo, P.E. 52609
Created by Independent Third Party: Yes
Evaluation Reports
Other: Maximum clip spacing 12" o/c
FL_ 24221 RQ AE R17-296 5,adf
Created by Independent Third Party: Yes
24221.5
Dynamic Metals 1-1/2" Mechanical
(Copper)
1-1/2" Mechanical Seam, 16 Oz Copper, Non-structural roof
panel
Limits of Use I
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-198.5
Other; -198.5 psf at maximum clip spacing 12" o/c -153.5 psf
Installation Instructions
FL24221 RO II 17-296 06 DWG plif
Verified By: Pedro De Figueiredo, P.E. 52609
Created by Independent Third Party: Yes
Evaluation Reports
FL24221 RO AE R17-296 6.0df
at maximum clip spacing 16" o/c
Created by Independent Third Party: Yes
24221.6
I
Dynamic Metals 1-3/4" Snaplock
(Aluminum)
1-3/4" Snaplock, 0.032" Aluminum, Non-structural roof panel
Limits of Use I
Installation instructions
Approved for use InIHVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-228.5
Other: -228.5 psf atlmaximum clip spacing 9" o/c -168,5 psf
at maximum clip spacing 19" o/c
FL24221 RO II 17-296.09 DWG.2df
Verified By:'Pedro De Figuelredo, P.E. 52609
Created by Independent Third Party: Yes
Evaluation Reports
FL24221 RO AE R17-296 9.odF
Created by Indepengeit Pagjaes EMM
24221.7
Dynamic Metals 2" Mechanical
2" Mechanical Seam �3 "; lum , N -stL urIV,
https://www.floNdabuilding,org/pr/pr app_dtl.aspx?param=wGEVXQwtDquUsDrhuM3DGM%2bm17wFt13%2fYFSE6n� wt /° HJB�chAN 3A%3d
I
' a I Date: 811712017
;! E N , C �q Inc. REF.#: 17-29610
•-+----T--
=r<
1791 Blount Road unit 907
Pompano Beach - Florida ; 33M 1" NAILSTRIP 26 GAUGE STEEL PANEL
Tel: (754) 307-1319 Fax: (754) 205-6846
Email: Engoo@AOL.com I _ _ 9
1.0 Product Manufacturer: Dynamic Metals, LLC
$40 Pike IIoad
West Palm Beach, Florida 33421
2.0 Code Edition, erida Building Code 2017 - 6th Editi
Applicable' fo_rR_on_RVRz Unly
Chapter15
3.0 Evaluation Method: Engineeril g Evaluation method ID in accordance with 61G20-3.005 F.A.C.
4.0 Product Classification:
Category: Roofing
Subcategory: Meta Roofing - non structural
Not Applicable for 6VHZ
5.0 Product Description:
5.1 Trade Name: Dynamic 1" Nailstrip 26 Gauge Steel Panel
5.2 Panel Properties:
Material: Average Fy=64 ksi
Panel Thickness: 0.0165"
Coverage:16" maXimum width x various lenghts
Ribs Height: V rib heigh mating with 3/4" lower rib at 16" o.c.
5.3 Panel Clip Properties:
Not available
4.4
5.4 Minimum Deck Requirements:
Minimum 15/321' 4 ply APA CDX plywood secured to 2x SYP with 8d ring shank nails
spaced at 4"oc. 2x SYP joists spaced no more than 24"oc.
Deck to be properly installed as per the FBC requirements over minimum 2x SYP rafters
spaced no morelthan 24"o.c.
Slope Range: ,yet:Lttr pig Qc
3:12�or greater - without lap sealant �...... .. '(
lesslthan 3:12 - with lap sealant
�
�o OFRID
. o-
I
7
E N G C 0, inc.
1791 Blount Road unitJ907
Pompano Beach - Florida - 33059
Tel: (754) 307-131 g Fax: (754) 205-5846
Email: Engco@AOL.cgm
5.5 Minimum Underlayment:
Date: 8/1712017
REF.#: 1,7-29610
30# Asphalt saturated organic felt paper installed with a minimum 4" side lap and 6" end
laps. Underlayment shall be fastened with corrosion resistant approved fasteners as per
the Florida Building Code and spaced 6"oc at all laps and two staggered rows 6"oc in the
field of the row. Or, �ny underlayment having a current product approval,
5.6 Minimum. Fire Barrier
VersaShield with a i inimum 4" side lap and 6" end laps. VersaShield shall be fastened
l
with corrosion resistant approved fasteners as per the Florida Building Code spaced at
6"oc at the perime#er and overlaps and two intermediate staggered spaced rows at 6"oc.
Or, any approved fire barrier having a current Product Approval. See Limitations #11.2
5.7- Fasteners:
installed through ail Strip Panel (Not Pre-existing slots): #10-94" Panclip MTW
fasteners spaced at 6"oc
6.0 Product anchorage to Roof Deck:
6.1- Panels are to be secured through the nail strip leg of the panel using #10-9x1" Pandip MTW
fasteners spaced at 6"oc. The! fasteners are to be positioned to go through the nail strip panel and
not the pre existing slots. The female leg of the panel snap fit to the male leg of the panel.
7.0 Uplift Pressures Rating:
UL 580 - Standard for Safety, Tests for Uplift Resistance of Roof Assemblies
Safety
Anchors
Installation
Delsign Pressure
Factor
Spacing
Field
231 psf
2
6" oc
Corner
Extrapolation is notallowed
• Na, 52609 .
-� STATE
ri
` ' I Date: 8f1712017
E ! e G 0J/iG. REF.: 17 29610
1791 Blount Road unit
Pompano Beach - Fla
Tel: (754) 307-1319 F
Email: EngcogMOL.m
8.0 Summary of Test Results:
8.1.4rchitectural Testing, Inc.,
8.2 Report G3443.08-450-44,
8.3 UL 580 - Standard for Safe
8.4Test Specimens: 120" x 12
8.5 Testing Assembly
8.6 Report H6854.01-106-31,
- $3069
,754) 205.6846
Iest Palm Beach; FL.
ted 06/15/2017.
Tests for Uplift Resistance of Roof Assemblies
with 16" x 120" panel coverage
ted 10/19/2017.,
Layer 1: 30# Asphalt saturated organic felt paper installed with a minimum 4" side lap and 6" end laps.
Underlayment shall be fasteneId with corrosion resistant approved fasteners as per the Florida
Building Code and spaced 6"oc at all laps and two staggered rows 6"oc in the field of the roll. Or, any
underlayment having a current product approval.
Layer 2: Versa Shield with a minimum 4" side lap and 6" end laps. VersaShield shall be fastened with
corrosion resistant approved fasteners as per the Florida Building Code spaced at 6"oc at the
perimeter and overlaps and two intermediate staggered spaced rows at 6"oc. Or, any approved fire
barrier having a current Product Approval. See Limitations #11.2
Layer 3: 26 Gauge - 0.01875" thick x 15" Gavanized steel panels secured to the wood deck using #10-9 x 1"
Panclip MTW fasteners spaced at 6"oc. The fasteners were positioned to go through the nail strip
Field comer panel and not the pre-existing slots. The female leg of the panel snap -fit to the male leg of the
Installation adjacent panels
9.0 Installation Instructions:
Panels to be installed as per manufacturer instructions and fastening patterns described herein.
NO.5260
'� '• STATE ? c.
OCT 2 0 2011
7
•,ENGCO inc.
I
1791 Blount Road unit 907
Pompano Beach - Florida - 33059
Tel: (754) 307-1319 Fax: (754) 205-BM
Email: Engoop__AOL corn
10.0 Design Procedure:
10.1- In order to verify pro
Design Rating on section 7
chapter 16 requirements.
10.2 - Product Pressures R.-
10.3 - Supporting structure
10.4 - Deck sheet must met
11.0 Limitations and Conditions of Use
11.1- installation must not
Neither rational analysis, ni
pressure zones (i.e. perimtj
11.2 - Fire Classification is r
Directory for fire rating oflt
11.3 - Product were not e i i
loads I
Date: 8117/2017
REF.#; 17-29610
adequacy for an specific project, contractor must compare Uplift
e with the Project Design Wind pressures calculated based on FBC
hg must be greater than the Project Design Wind Pressures
•e to be designed by others and in compliance with the FBC
the minimum thickness specified on item 5.4 above
cceed the maximum allowable design pressures listed in this report.
extrapolation shall be permitted for enhanced fastening at enhanced
r, extended corners and corners)
t part of this acceptance; refer to a current Approved Roofing Material
s product.
gated structurally to resist shear diaphragm, axial, transverse or racking
11.4 - All Products listed herein shall have a quality assurance audit in accordance with the Florida
Building Code Rule 61G20-3 of the Florida Administrative Code
11.5 - Drawing numbered 17-296.10 dwg are part integral of this report.
I
12.0 Certificate of Independence:
TAS 125- 03 - Uplift Resistance Test - G3443.09-450-44
TAS 100- 95 - Wind Driven Rain Test - H2687.02-450-44
ASTM G26/G 155 - Accelerated Weathering 2000 hours - PRI Report- VLS-004-02-01
ASTM 8117 - Salt SpraylTesting of Coating 1000 hours - PRI Report - VLS-005-02-01
I
13.0 Certification:
i
In the professional opinion of this evaluating engineer the product herein described meets the
requirements of the Florida Building Code 2017 - 6th edition, for use in the NON-HVHZ and HVHZ
(Broward and Miami iDade counties) when utilized within the limits of use noted herein
it
v
No. 52609ST
i
1
i
DRAWINGS #: 1 7-29G. t O
REPORT : 1 7-20G. 10
s STAIE 0
DRAWINGS #: 17-29G. ! O
REPORT: 17-29G_ 10
- DYNAMIC I " NAILSTRIP 2G GAUGE
GALVANIZED- STEEL PANEL
PANEL
I C-01X I PANCL I P MTW FASTENERS
SPACED AT 6"OC FASTENER POSITiCiNED
THROUGH THE CIA I L STRIP NOT THROUGH
/ THE PRE-EXISTING SLOTS
iNO.
ROOF DECK.
t4 ^vVININ_M 15/3c
L-4-PLY CDX PLYWOOD SHEATING
61