HomeMy WebLinkAboutLETTER - ROOF INSTALLATIONDESIGN & F
March 8, 2018 W ANNED
By
Building Department St Lucle C0111
St. Lucie County
Plan Review
Building Department
2300 Virginia Avenue Fort Pierce, FL
Installation
To Whom This May Concern,
Please know I personally will be
installation of the roof underlays
All correspondence will be
for your records.
Should you require any further
Sincerely,
Brian Maskol, P.E.
Summit Design & Forensics, Inc.
State of Florida I
License No. 66080 l
JMMIT
RENSICS, INC.
CONTRACTOR COPY
Te r- m 4-
)'W01 - O3a7
ing site observations and letters regarding the
metal roof and flashings.
and sealed by our office and submitted to the County
please do not hesitate to contact this office.
(Z-; \oeNSi
-
-
LU Z
4;
SIC) F1 Al \`�����
111111
v.
JOB ADDRESS_306 RIO MAR DRIVE PORT ST. LUCIE, FI 34952_
NEW ROOF RE-ROOF_X_ REPAIR_
ROOF AREA_2035 SF
ROOF TYPE_5V CRIMP 26GA STEEL ROOF PANELS_
k-H!L I _"
ALL CONSTRUCTION & MATERIALS SHALL CONFORM TO 2017 FLORIDA BUILDING
NOTE: REMOVE EXISTING ROOFING TO PLYWOOD; REPLACE ALL DAMAGED OR ROTTEN PLYWOOD WITH NEW COX TO
MATCH EXISTING THICKNESS; RE -NAIL ENTIRE ROOF W/ 8d RING SHANK NAILS @ 6' D.C: @ EDGES & FIELD TO
TRUSSES (2- LONG, 0.113 DIA. FULL RND. HEAD).
ASCE 7-10 & 2017 FBC ENCLOSED BUILDING—)L_ PARTIAL ENCLOSED_ OPEN —
PART 2 LOW RISE
WIND SPEED (3 SEC.):_160MPH_ RISK CAT.:_2_ EXPOSURE:_B_ MEAN HT.:_31 FT._
TYPE OF CONSTRUCTION:,C_CBS _FRAME SLUM
ROOF PIf0H:_4/12_
ZONE 1 P: _25 PSF (4/12 SLOPE)
ZONE 2 P: _44 PSF (4/12 SLOPE)
ZONE 3 P:_65 PSF_ (4/12 SLOPE)
MAX. ALLOWABLE PRESSURE PER NOA:_86 PSF
DECK TYPE: _PLYWOOD— THICKNESS:_15/32' MIN._
BASE SHEET _TRI-BUILT SYNTHETIC 25 ROOF UN DERLAYMENT INSTALLED PER MANUFACTURER'S SPECIFICATIONS_
FASTENERS & SPACING:_ROOFING NAILS & PLASTIC TABS, 9' AT LAPS, 2 ROWS AT 12' IN FIELD _
ROOF FASTENERS:_09 X 1}' MIN. W/ SEALING WASHERS_
FASTENER SPACING FOR METAL ROOF PANELS: FIELD_16_ PERIM_16_ I C'ORNERS_16_
DRIP EDGE SIZE:_3'X3' LAP 4'_ DRIP MATERIAL:_26GA_ FLASHINg MATERIAL:_26GA_
SK-01
OF 1
DATE
DESIGNED
BIM
03-08-2018
DRAWN
MJN
03-08-2018
CHECKED
JOB NO.
2018-049
RESIDENCE
306 RIO MAR DRIVE
PORT ST. LUCIE, FL 34952
RE! ROOF DETAILS
,�LI!IIIsf
1 f
o
Al
01
ION
BRIAN MASKOL, PE
FL. PE #66080 .
,\\4,SUMM1T
DESIGN & FORENSICS, INC.
725 SE PORT ST. LUCIE BLVD., SUITE 203
PORT SAINT LUCIE, FL 34984
(772)285-0572