Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL GENERATOR6f SCANNED 16/20/22 kW st LucB 0ni mb, INCLUDES: • True Power"m Electrical Technology • Two Line LCD Multilingual Digital Evolution TM Controller (English/Spanish/ French/Portuguese) • Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 4 for Details. • Electronic Governor • System Status & Maintenance Interval LED Indicators • Sound Attenuated Enclosure • Flexible Fuel Line Connector • Direct -To -Dirt Composite Mounting Pad • Natural Gas or LP Gas Operation • 5 Year Limited Warranty • Capability to be installed within 18" (457 mr of a building* FEATURES i j l a iG ENERAC ST.LUCIE COUNTY PLAN REVIEW BLDG: GUARDIAN® SERIES DATE: Residential Standby Generators ELE DATE:22� Air -Cooled Gas Engine DATE: MECH: Standby Power Rating DATE: Models Gam, G007037-0 (Aluminum - Bisque) -16 kW 60 Hz Model G007035-0 (Aluminum - Bisque) -16 kW 60 Hz Models G007039-0, 0007038-0 (Aluminum - Bisque) - 20 kW 60 Hz Models G007043-1, G007042-1 (Aluminum - Bisque) - 22 kW 60 Hz 0 MKOVATIVEENGINE DESIGN A RIGOROUS TESTING are at the heart of Generac's 0, success in providing the most reliable generators possible. Generac's;G-Force engine lineup offers added peace of mind and reliability for when you need it the most. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. ® TRUE POWER"' ELECTRICAL TECHNOLOGY. Superior harmon form produce less than 5% Total Harmonic Distortion for utility quality confident operation of sensitive electronic equipment and micro -chip such as variable speed WAC systems. � TEST CRidER1A: J PROTOTYPE TESTED J NEMA MG7.221 SYSTEM TORSIONAL TESTED J MOTOR START and sine wave rer. This allows led appliances, ST c(EL)us Q LISTED UIEHES— Note; CUL certification only applies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are UL certified in the USA only. *Only If located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes. 80"AA-FREWENCY COMPENSA70 VOLTAGE RMLATIOM This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at :0 %. MGM SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. 0 GENERAC TRANSFER, SWITCHES" Long life and reliability are LUATION synonymous with GENERAC POWER SYSTEMS. One reason for this ABILITY confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. GENERA L �t?•���� I— PROMISE. *�,�* untie •B• I fn Mo USA WVc(omastis anesnralpn pub, -�•-�- . _ GENERAL° 16/20/22 kW specifications Generator Model ,+„RatetlMaKiinumCnnd'nuou Powe�t�pacfty,�(Lp)%;�:���� a -� •-_- Rated Maximum Continuous Power Capaelty (NO) v `' Rated Maximum Continuous Load Current Volts (LP/NG) srtaliHennohtc�Distorfiom of une Circuit Breaker Fhasey Number o1 Rotor PolesF " tRatediAGFYequency. Power Factor Batterytleq"ulrement (not,l�tcluded) ~� , ; Unit Weight (Ib/kg) �Dlmenslon"s.�(L�XUfxH)jiNmrni Sound output in dB(Aj at 23 ft (7 m) with generator operating at normal load"• l- ` Y Engine Type of Engine Displacement v y `CyltnderBt k "" �: , �gniti?mSystem Governor System -'' "� ` ' rCamp loress n R tied F " Starter 0007035.0, 000703", G007038-0, G007039.0 G007042-1, G007043.1 G007037.0 (16 kW) (20 kith) (22 k4Vl to uuu wars ` 16,000 Watts" 18,000 Watts' 19,500 66.6/66 6 83.3/15 91 fi/81.3 Less;than 5% Less�tn96 t ram' ''iLass thanr546 , �' 70 Amp 10D Amp 100 Amp 2 2 2 Hi _._ "w 11601Hz 7, �71-60Hz,; , 1.0 10 » 1.0 �- ;_ _ = 12VDI�,'Group!26R!540�CCA�MInlmum�arl r uo p35AGM'650_=C'_CA:MI In me ~�_' 406/186 4 440/203 _, 486/211 48'X 25�Xd26.6 9/1218'X— Icise.rnude""r58; 67Y_ r ` _ - . _ 5 min 5 min.__..:..-.-.-.:..� _-�.._._ ...,�.5 �8n ..... GENERAL G-Farce 1000 Series .2 ^� � k.v � 999 CC 999�Cc 999 cc.�� • r Attiminumsw/ltastironSleave Overhead Valve Overhead Valve Overhead Valve f r; Solid slate:w/;Magneto 15_ clld state w/,Magneto``"""-'"S_ 01II •state.w/iMagnefo1 ElectronicElectronic Electronic 12Vdc peranng rpm ..- , __ _ ^rr . ,,. 4_L' 6 3 600 3,600 ` npprv� , r:y qv�7 L 3,fi00 raltConsurnp0on :. ' J 1%2luad=I ! = ;1 Fgllioad 2113((617�)r 204t(t3.7,e)r 228,(t3�46)! quidlPropane° fi°/Itrr,(gaUhr)5[I/hr]4 309+(8475), 0111852)� 32P,(9S2G ) d/216ad , r r91! 6 (2:'S2)t[9'53JI 86t(2'37) [S`98JE 92k(2'53)`)19:571i � � y - l _ _ 106.8,2.94),[d�11ij`.___�=129�356�[13:48Jj 1'42r(3.90);[e14_77] ..,:;. rte. Fuel pipe must he sized forfu(Lload. Required fuel pressure to generator fuel inletatallload rang as - 3.5-7" water column (7-13 mm mercury) for natural gas,10-12°water column (19-22 rr LP�sas.FFor Btu content, multiply /hrx 2600 (LP) or ftsPor x 1000 (NG). For Medeioule centent. multiply msnn v as t G 1101 �,°i..,, 07 ea AIM% mm mercury) 2-Line Plain Text Multilingual LCD Display "y^ '~ 4 Simple user Interface for ease of operation Manual y :. �AutomaOc;Sta►t on'Utii failure r =_ ily, 7 day;exerci E , Start with starter control unit stays on If u8lity iatls, transfer to load takes place. Ready to Run/Maintenance Messages y Stays;unit:,Poweutesre�touedrGomrol?and±charger's011ioperato. Standard iEoO uniNiurs _ Programmable stM delay betw� een 2-160D c e onds ilJt�lity Vo tagf a Lo Retumlto"-tt8lity d slabl@ (BroW00oG3etting)1 Standard (programmable by dealer only)' Future Set Capable Drerciser/FxerciseSetErrorWaming� `�-" —= Aun%Alarm/Matidenance;4ogs ' "� ': ��-------•- -�--�--.-�.-�m'4140171„til/i902t6V?" '"""-"""""''�^'��^; Standard " - „ -: .r �K� Engine Start Sequence "'" ` ` F '� 5D'Events Eacfi ' r �� k VCyclic cranWng 16 sec 7 5tarfereLack out=7 T •: _ ,.- r an rest (90 sec maximum duration). Srnart Battery Charger "" - - 5 Statter°canLtot re�epgega untllt5+sec after engtna has!atopped Charges Fa'pIi�PSIssin rAl;.Wam(n"" " �,: ~m -� P- Standard s LOW Battenr/Battery Problem Pretarllnn _,:• Standard .-• 1------., mwnwuc,vQr�a erne wanan+wrm!Over;and;Ue e[utf Ito a",'PreteCge_(I "'" `�`��'' uaumau "' Indary%OverlaadlStepper Overrarrrent Protection _ ""`t'"-""i '" `` '` 'Y` `-�•-•---- 4' aiety'iEused/Fuse�. I��6n'em;_ protecObn�:— "LL"""-;�.-«�----- �Stendard '� }�` �"_• attarnatic Low Otl Pressure/FII h DIITe D utdowri � � � V - - - ---�-- ---•.�•--� � �_ �Sta'ndaN� "•`-•"�'-"'""'-"' ���~~ , _ g m erature Sh v Standard ivercranWOverspae�'(@,i2�Flz)%rym�$snse Lo s 5hutdowm ""`� - -- .,- lgh Engine Temperature Shutdoxm I'I _ Standardl.',"' ifemal?FaultllncorrectiWiiln Proteotlo` t r _ Standard ommon External Fault Capability .- „ - w rti fe, Itl UPp�radable Firmwar"e�y�:;"� ; , � - � Standard V`" "' "Saundlavelsarerdkenham0efmraolNeDenarator.Soundlevelstakanlromothersidesafthegeneratormaybehi�erdependingonNutalM6onparametars.l�tln datlnfti°na-Bien of the utility pourer outage. No overload capability Isavallable far this rdung, (NI ratings in accordance with 8555141503D46 and DINe211) Madmum Idlovoit aDmps and current areb ubleetiloaod limited by such moors as fLwl RVIr paalouule coolant,ambtemtemperature,ai6tude.erginapowarandcandillan,ele.MMatddmumpowerEeueases ioul3.Spercentloreach1,000reet(aD4,ematers)abovesealevel;andalsowilldacraaseabouttpercentroreach6°0(loon above la*C(6o°F). GENERAL 16/20/22 kW available accessories G007005-0 `Wi-FI LP Fuel Level Monitor G006463-4 .' Mobile LInk- G005819-0 ' 26R Wet Cell Battery - G007101.0 Battery Pad Warmer .8007102-0 ; Oil Warmer G005621.0 :Auxiliary Transfer Switch tContact Kit G007027-0 - Bisque 3 Fascia Base Wrap Kit , (Standard on 22 kW) G005703-0 - Bisque I Paint Kit G006485.0 .Scheduled Maintenance Kit G006873.0 !Smart Management Module (50 Amps) Le"610evlew The Wl-R anal Itoring the LP 1 unexpected pc Is In need of a Generac's Mal cess to an Inte text message i Every standby cell battery for The pad warm) (Not necessaq Oil warmer sill 0°F. 'The auxiliary tt you may not n The fascia bas sleek, contoun holes located I If the generato 'future corroslc enclosure. Generac's schi maintenance o Smart power power Dimenslons shown are appreximate. Refer to Installation manual for LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Mon-, s fuel level is an important step in making sure your generator is ready to run during an' failure. Status alerts are available through a free application to notify when your LP tank! Is Link allows you to check the status of your generator from anywhere that you have ac-1 let connection from a PC or with any smart device. You will even be notified via a -mail or', hen a change in the generator's status occurs. Available in the U.S. only. enerator requires a battery to start the system. Generac offers the recommended 26R wet= ise with all air-cooled standby product (excluding PowerPact®). rests under the battery. Recommended for use if the temperature regularly falls below 0°F. for use with AGM -style batteries). directly over the oil filter. Recommended for use if the temperature regularly falls below isfer switch contact kit allows the transfer switch to lock out a single large electrical load; id. Not compatible with 50 amp pre -wired switches. wrap snaps together around the bottom of the new air cooled generators. This offers a ' appearance as well as offering protection from rodents and Insects by covering the lifting the base. enclosure is scratched or damaged, it Is Important to touch-up the paint to protect fromY The paint kit Includes the necessary paint to properly maintain or touch-up a generator uled maintenance kits provide all the hardware necessary to perform complete routine a Generac automatic standby generator. € ent Modules are used in conjunction with the Automatic Transfer Switch to Increase its ant capabilities. it provides additional power management flexibility not found in any other; lent system. dimensions & UPCs dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. If r FRONT VIEW Model UPC G007035-0 696471070354 G007036-0 696471070361 G007037-0 G007038-0 696471070378 696471070385 G007039-0 G007042-0 G007043-0 696471070392 696471070422 696471070439 G E N E RAC® Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • enera e c.am 02017 Generac Power sylstems, Inc. All rights reserved. All speclUcaUons are subject to change without notice. Part No.10000000194-F 6/3/17