HomeMy WebLinkAboutREVISION 9-19-18OFFICE USE ONLY: SCANNED
DATE FILED:
� REVISION FEE: A, F) PO
P
RECEIVE
SEP 19 2018
ST, Wop COun€Yl rAM"Icsine
LOCATION/SITE
PERMIT#
RECEIPT #
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982.5652
(772) 462.1553
APPLICATION FOR BUILDING PERMIT DEFERRAL
PROJECT INFORMATION
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
4
CONTRACTOR INFORMATION: F'"ILE COPY
STATE of FL REG./CERT. #: ST. LUCIE CO CERT. #: N
BUSINESS NAME:
QUALIFIERS NAME:
OWNER/BUILDER INFORMATION:
NAME
ADDR
CITY:
PHONE (DAYTIME:
ARCHITECT/ENGINEER INFORMATION:
NAME:
ETWIT"Erm
CITY:
PHONE (DAYTIME):
SLCCC.• 9/23109
Revised 07/17118
STATE:
FAX:
FAX:
Ell
ZIP:
t
a.
GENERAL NOTES
I. THESE DRAWINGS WERE PREPARED WITH THE
ASSUMPTION THE CONTRACTOR/OWNER BUILDER
S KNOWLEDGEABLE OF COMMON CONSTRUCTION
PRACTICES,
2. THE CONTRACTOR/OWNER-BUILDER SHALL REVIEW
DRAWINGS FOR ACCURACY AND INTERPRETATION.
ANY DISCREPANCIES SHALL BE BROUGHT TO THE
ATTENTION OF THE DESIGNERS PRIOR TO
CONSTRUCTION,
J. THE FOUNDATION PLAN SHALL BE VERIFIED BY THE
CONTRACTOR/OWNER-BUILDER TO CORRESPOND WITH
THE FINAL ENGINEERED TRUSS LAYOUT.
4. DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE.
DO NOT SCALE DRAWINGS
u
FILE COPY
CUT AND REMOVE EXISTING DAMAGED WEBS,
BOTTOM CHORD, TOP CHORD, AND VERTICAL
WEBS AS REQUIRED
TYPICAL EXISTING TRUSS (PARTIAL VIEW)
NOT TO SCALE
INSTALL NEW 5/8" CDX PLYWOOD GUSSET
ON EACH SIDE OF CUT SECTION OF TRUSS.
WHERE NEW 2" X 4" MEMBERS HAVE BEEN
INSTALLED ALONG DAMAGED AREAS
ATTACH W/(2) 100 NAILS INTO ALL WEBS
AND CHORDS WHERE GUSSET HAS POSITIVE
CONTACT W/AT 3" O.C. MAX THRU. BOTH SIDES
INSTALL NEW 21Ix4" NO. 2
SPF CHORDS/WEB AS REO'D
THESE PLANS AND ALL PROPOSCO WOF§(
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORCI TO
Cv"sPLY WITH ALL APPLICABLE CODES.
2'-0" (MINIMUM)
TYPICAL TRUSS REPAIR (PARTIAL VIEW
NOT TO SCALE
CD
t
/ g 0340 03 7� \ 0 3 a 31
ST, LUCIE COUNTY BUILDING ECEIVED
REVIEWED FOR COMPLIANCE
SEP 18 Z018
PLANS AN P RMIT MU E KEPT PN IOB
SITE OR NO INSPECTIONS) WILL E MADE ST.tucieCoWkY Pent
NOTE:
THESE DRAWINGS HAVE BEEN DESIGNED TO THE BEST OF OUR
KNOWLEDGE TO BE ACCURATE AND CORRECT, BASED ON THE
VISIBLE FIELD CONDITIONS OBSERVED OR PRESENTED. ANY
UNFORESEEN FIELD CONDITIONS DISCOVERED DURING DEMOLITION
AND/OR CONSTRUCTION THAT MAY REQUIRE ADDITIONAL WORK
OR REVISIONS TO THE PERMITTED DRAWINGS WILL BE ADDRESSED
ACCORDINGLY AND CONSIDERED AS ADDITIONAL WORK. NO ADDITIONAL
WORK'HQI I PF PERFDRMFD WITHOUT AN ESTIMATE FOR ADDITIONAL
momwamI n Hlvu err r_P/BUILDER.
TO THE BEST OF MY KNOWLEDGE, INFORMATION AND BELIEF,
THE
FOLLOWING PLANS
COMPLY
WITH ALL APPLICABLE
REQUIREMENTS
OF
THE 2017
FLORIDA
RESIDENTIAL
BUILDING
CODE
6TH
EDITION
AND
LATEST
ADOPTED
SUPPLEMENTS
GENERAL NOTES: WOOD
1. ALL FRAMING CONSTRUCTION WORKMANSHIP AND MATERIALS
(INCLUDING TRUSSES) SHALL CONFORM WITH THE SPECIFICATIONS AND
REQUIREMENTS OF THE REF:RENCES LISTED BELOW:
"AMERICAN INSTITUTE OF TIGER CONSTRUCTION" THIRD EDITION 1985
"NATIONAL DESIGN SPECIFICRION FOR WOOD CONSTRUCTION "1991 AND
SUPPLEMENT
"U.S. PRODUCT STANDARD 5 1" OR APA PRP- 108 PERFORMANCE
STANDARDS "MANUAL FOR FUSE FRAMING, WOOD CONSTRUCTION
DATA NO. 1 "NATIONAL FOR:ST PRODUCTS ASSOCIATION.
2. ALL TRUSS BEAM AND COLLMN MEMBERS SHALL BE SPECIES AND GRADES
OF LUMBER WHICH WILL PRODUCE DESIGN VALUES EQUAL TO OR GREATER
THAN VALUES FOR SOUTHERN YELLOW PINE NO. 2, 19% MAX. M.C.
3. GALVANIZED METAL HANGER: AND FRAMING ANCHORS SHOWN ON THE
PLANS SHALL BE USED ANC SHALL BE FASTENED IN ACCORDANCE WITH
THE MANUFACTURERS SPECI'ICATIONS, SUBSTITUTIONS REQUIRE ENGINEER'S
APPROVAL.
4, ANCHORING AND NAILING NG IDENTIFIED SHALL COMPLY WITH THE
NAILINLG SCHEDULE GIVEN WTHIN "MANUAL FOR HOUSE FRAMING",
AND 2Q17 FLORIDA BUILDING CODE 6TH EDITION.
UM OF TWO STUDS S
5. A MINIMUM HALL BE INSTALLED ADJACENT TO ALL
OPENINGS IN EXTERIOR AND LOAD BEARING WALLS AND BENEATH ALL
BEAM & GIRDER BEARING POINTS.
6. TRUSSES SHALL BE SIZED AND DETAILED IN ACCORDANCE WITH THE
DIMENSIONS AND LOADS INDICATED.
7. TRUSS SHOP DRAWINGS AND CALCULATIONS SHALL BE SUBMITTED BY
A FLORIDA LICENSED ENGINEER FOR REVIEW PRIOR TO FABRICATION.
THE SPECIALTY ENGINEER SHALL SPECIFY BLOCKING AND BRACING N
NECESSARY TO WITHSTAND WIND LOADS DETERMINED USING ASCE 7-10.
8. AS A MINIMUM, ROOF SHEATHING SHALL CONSIST OF 15/32 " (NOMINAL) APA
SPAN RATED, EXPOSURE 1 PLYWOOD OR O.S.B., NAILED TO SUPPORT WITH
8d RING SHANK NAILS AT 6" O.C. ON EDGES, 6" O.C. IN FIELD
9. ALL EXTERIOR WALLS SHALL BE SHEATHED WITH 15/32" APA SPAN RATED,
EXPOSURE 1 PLYWOOD OR O.S.B. THE SHEATHING SHALL BE ATTACHED TO
FRAMING WITH 8d COMMON NAILS AT 4" O.C. ON EDGES, 6" OC IN FIELD
10. EXTERIOR AND INTERIOR LOAD BEARING WALLS SHALL BE FRAMED WITH
2X MEMBERS AT 16" O.C. MAX. SPACING FOR MAX. 8' HIGH PARTITIONS.
FOR HEIGHTS ABOVE 8' REFER TO WALL SECTIONS. STUDS SHALL BE
SPRUCE -PINE -FIR #2 OR SPECIES WITH EQUAL OR GREATER
DESIGN VALUES.
11. ALL PRESSURE TREATED LUMBER SHALL BE SOUTHERN YELLOW PINE #2
19% MAX. M.C. IN ACCORDANCE WITH AWPA STANDARDS C1,C2 AND
C9 LATEST EDITIONS, WITH A WATERBORNE PRESERVATIVE IN ACCORDANCE
WITH STANDARD PS, ALL NAILS AND SCREWS SHALL BE STAINLESS STEEL
OR GALVANIZED.
12. WHERE DRAWING INDICATES APPLIED EXTERIOR FINISH OVER APPROVED
WATER BARRIER OVER WOOD FRAMING MEMBERS. OWNER IS RESPONSIBLE
TO INSTALL ALL REQUIRED SEALANT, FLASHING, ETC. TO MAINTAIN WATER-
PROOF INTEGRITY TO PREVENT MOISTURE INFILTRATION INTO STRUCTURE.
OWNER IS RESPONSIBLE FOR PERIODIC MAINTENANCE AND UPKEEP OF
EXTERIOR APPLIED FINISH TO MAINTAIN WATERPROOF INTEGRITY TO PREVENT
DAMAGE TO INTERIOR COMPONENTS.
13. 1404.2 WATER -RESISTIVE BARRIER.
EXTERIOR WALLS OF FRAME CONSTRUCTION RECEIVING A VENEER SHALL
BE PROVIDED WITH A WATER -RESISTIVE BARRIER. THE WATER RESISTIVE
BARRIER SHALL BE A MINIMUM OF ONE LAYER OF NO. 15 ASPHALT
FELT, COMPLYING WITH ASTM D 226 FOR TYPE 1 FELT, SHALL BE
ATTACHED TO THE SHEATHING, WITH FLASHING AS DESCRIBED IN
SECTION 1405.3, IN SUCH A MANNER AS TO PROVIDE A CONTINUOUS
WATER -RESISTIVE BARRIER BEHIND THE EXTERIOR WALL VENEER.
1404.2.1
WHERE CEMENT PLASTER (STUCCO) IS TO BE APPLIED TO LATH OVER
FRAME CONSTRUCTION, MEASURES SHALL BE TAKEN TO PREVENT
BONDING BETWEEN THE CEMENT PLASTER AND THE WATER -RESISTIVE
BARRIER. A BOND BREAK SHALL BE PROVIDED BETWEEN THE
WATER -RESISTIVE BARRIER AND THE CEMENT PLASTER (STUCCO)
CONSISTING OF ONE OF THE FOLLOWING:
GENERAL NOTES
1. THESE DRAWINGS WERE PREPARED WITH THE ASSUMPTION THE
CONTRACTOR/OWNER-BUILDER IS KNOWLEDGEABLE OF COMMON
CONSTRUCTION PRACTICES.
2. THE CONTRACTOR/OWNER-BUILDER SHALL REVIEW DRAWINGS FOR
ACCURACY AND INTERPRETATION. ANY DISCREPANCIES SHALL BE
BROUGHT TO THE ATTENTION OF THE DESIGNERS PRIOR TO
CONSTRUCTION.
3. THE FOUNDATION PLAN SHALL BE VERIFIED BY THE CONTRACTOR/
OWNER -BUILDER TO CORRESPOND WITH THE FINAL ENGINEERED
TRUSS LAYOUT.
4. DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE - DO NOT
SCALE DRAWINGS.
5. FLASHING SHALL BE PROVIDED PER FIELD CONDITONS.
6. MOISTURE PROTECTION SHALL BE PROVIDED BETWEEN ALL
MASONARY AND NON PRESSURE TREATED WOOD SURFACES.
7. A 1/2" DIAMETER X 10" LONG MINIMUM WEDGE ANCHOR
MAY BE USED IN LIEU OF 1/2" DIAMETER J-BOLTS.
MINIMUM EMBEDMENT = 7" PER FLORIDA RESIDENTIAL BLDG CODE
8. ALL NAILS SHOWN SHALL BE CORROSION RESISTANT COMMON
TYPE UNLESS NOTED OTHERWISE.
9. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE
DRAWINGS AND SPECIFICATIONS LISTED.
10. THE GENERAL CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION
SHOWN ON THE DRAWINGS. ANY QUESTIONS OR DISCREPANCIES SHALL
BE BROUGHT TO THE ATTENTION TO THE ENGINEER BEFORE STARTING
CONSTRUCTION.
11. THE STRUCTURE HAS BEEN DESIGNED TO MEET THE REQUIREMENTS OF
THE 2017 FLORIDA BUILDING CODE 6TH EDITION.
12. FDUNDATION AND SLAB ARE TO BE FORMED UPON SOIL WITH A MINIMUM
SNFE BEARING CAPACITY OF 2000 PSF.
13. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO UNIFORMLY
PROVIDE THE BEARING CAPACITY UNDER ALL FOUNDATIONS.
14. THE CONTRACTORS SHALL HIRE A GEOTECHNICAL ENGINEER TO
RECOMMEND SOIL IMPROVEMENTS REQUIRED TO OBTAIN THE MINIMUM
SAFE BEARING CAPACITY STATED ABOVE.
1. TWO LAYERS OF AN APPROVED WATER-RESISTANT BARRIER; OR
2. ONE LAYER OF AN APPROVED WATER-RESISTANT BARRIER OVER AN APPROVED
PLASTIC HOUSE WRAP; OR
3. OTHER APPROVED METHODS OR MATERIALS APPLIED IN ACCORDANCE WITH THE
MANUFACTURER'S INSTALLATION INSTRUCTIONS.
A CORROSION RESISTANT WEEP SCREED WITH A MINIMUM VERTICAL ATTACHMENT FLANGE
OF 3 '1A INCHES SHALL BE PROVIDED AT OR BELOW THE FOUNDATION PLATE LINE ON
ALL EXTERIOR STUD WALLS. THE SCREED MUST BE PLACED AT A MINIMUM OF 4
INCHES ABOVE THE EARTH OR 2 INCHES ABOVE PAVED AREAS AND SHALL BE OF A
TYPE THAT WILL ALLOW TRAPPED WATER TO DRAIN TO THE EXTERIOR OF THE BUILDING.
SCANNED
St LuCs County
' 7 "+84
g
1 inli
-REVISIONS-
ISSUED: 9-13-16
AN***
***
***
U)o ro
n 0, C N
� N O �
O
OJ N n
cl� J n -
} " H O
m Q N N U
�O] .�i� J SK
U
Q W
a -a wa ELu
d I- LL L.LI 0
N
O O O
El 0 ID
O
O
O
U
z
v�
EL
Li
0
U
z
QD
)
LLJ
Q
Wz
LLJ
LLJ
z_
U
z
I�,J LLl
I
0
LL_
Q
N
w
o`
Q
�
N7
LLJ
Q
LL
w
U
N
LL
�
-
w
QCL
w
s
w
LLJ
I-
~
(f
0
w
z
I
N
_Lj 0
r w cr
! 1 J1 LLB h7 Lc)
u ■
r
U;LF
Cl)
EY LLJ to
cl�LL_ Uati
LLJ J_ QO
W 3: w p
N
� o 0
z p r` - J =
w LLJ � IL LL
SHEET I OF 1
DRAWN BY-
DANIEL FRECHETTE
�3-03?