EVALUATION REPORT
Boral Roofing Evaluation Report M35710.12.10-R9
7575 Irvine Center Drive, Suite 100 FL14317-118
Irvine, CA. 92618 Date of Issuance: 12/21/2010
(602) 269-2288 Revision 9:10/14/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliall ce with the 61h Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Boral Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of thel Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agregment to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation c I anges. Trinity I ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by tf�e words "Trinity IERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report isllldisplayed , then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Repot shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
ot.
^v
Robert J.M. Nieminen P.E.
Florida Registration No. 59166, Florida DCA ANE1983
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it a
distributing products it evaluates.
2. Trinity I ERD is not owned, operated or controlled by any company man
3. Robert Nieminen, P.E. does not have nor will acquire, a financial inter
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial inter
product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert N
project on which this Evaluation Report, or previous versions thereof,
specifically for that purpose.
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES,
L•; _
>4%;ti•�
The facsimile seal appearing was authorized by Robert
Nieminen, P.E. on 10/14/2017. This does not serve as an
electronically signed document.
quire, a financial interest in any company manufacturing or
:turing or distributing products it evaluates.
in any company manufacturing or distributing products for
in any other entity involved in the approval process of the
i, P.E. are, in any way, the Designer of Record for any
used for permitting or design guidance unless retained
CONCEALED FASTENERS ORArrACHMEM
ARE THE RESPONSISILITY OF THE
CONTRACTOR OF RECORD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Boral Roof Underlayments, as marketed by Boral Roofing, have demonstrated compliance
with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the
following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set
forth herein.
STANDARDS:
Section
1504.3.1
1507.1.1, T1507.1.1, 1507.2.9.2
1507.3.3
REFERENCES:
Entity
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
UL, LLC. (QUA 9625)
4. PRODUCT DESCRIPTION:
4.1
4.1.1
4.1.2
4.1.3
4.1.4
Property
Wind Uplift
Physical Properties
Physical Properties
Examination
Physical Properties
Physical Properties
Tensile Adhesion / LTA
Adhesion
Tensile Adhesion / LTA
Tensile Adhesion / LTA
ASTM D1970
ASTM D1970
Tensile Adhesion / LTA
FRSA/TRI April 2012
ASTM D1970
Wind Uplift
Wind Uplift
Quality Assurance
Self -Adhering Underlayments:
Bor IeSea�50"T is a nominal 50-mil thick, pol
nderlayment; ets ASTM D1970.
Boral TileSeal® "T s a nominal 60-mil thick, poll
ets ASTM D1970 and FRSA/TRI
Standard
UL 1897
ASTM D1970
FRSA/TRI April 2012 (04-12)
Reference
M36790.07.11
B40380.08.12
C41420.09.12-2
B41940.09.12
B47390.07.14-1
B47390.09.14
NEI-031-02-02:REV
NEI-029-02-01:REV
NEI-046-02-01REV
NEI-076-02-01
NEI-034-02-02
BORR-001-02-01
BORR-005-02-01
Service Confirmation
Year
2012
2015
2012
Date
09/30/2011
08/28/2012
09/11/2012
09/13/2012
07/31/2014
09/04/2014
10/27/2010
12/03/2010
12/17/2010
02/14/2011
01/29/2013
03/17/2015
06/24/2015
Exp. 08/21/2020
yester-surfaced, self -adhering SBS modified bitumen roof
12.
urfaced, self -adhering SBS modified bitumen roof
GatorSeala is a nominal 55-mil thick, granular -surfaced, fiberglass reinforced, self -adhering SBS modified
bitumen roof underlayment; meets ASTM D1970.
Citadel" Plus is a nominal 48-mil thick, fabric-su faced, fiberglass reinforced, self -adhering SBS modified
bitumen roofing underlayment for use as a base -layer in two-ply underlayment systems; meets ASTM
D1970.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither TriniiyIERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retai ed specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ j risdictions.
Exterior Research and Design, LLC. I Evaluation Report M35710.12.10-R9
Certificate ofAuthoriration #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R8
Boral Roof Underlayments; (602) 269-2288 Revision 9: 10/14/2017
Page 2 of 7
I
I
QOTRINITYIERD
5.3 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
5.4 Boral Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof
covering.
5.5 Allowable Roof Covers: Table 1 pertains to use of each listed underlayment by -itself beneath the stated
roof covers. Refer to the installation instructions and Table 2 for two-ply underlayment options.
TABLE 1^ ROOF COv.ER OPTIONS „
Tile
Asphalt Adhesive -set Metal Wood Shakes Slate
Underlayment Shingles Nail-Ori Tile & Shingles
Bor "� Yes Nol^No Yes Yes Yes„ `
Boral TileSealHT °Yes Yesf Yes
Yes Yes: Yes
(See 5 5:1)
GatorSeal Yes „ N.o eYYes ;
5.5.1 "Adhesive -set Tile" is limited to use of following Approved tile adhesives / underlayment combinations.
TABLE 1A:'ALLOWABLE TILE ADHESIVE`[UNpERlAYf1gENT COMBINATIONS1
Adhesive
Florida Product Approval
Underlayments
DAP Foam Touch'n Seal StormBond Roof Tile Adhesive
FL14506
Boral TileSealHT
Dow TILE BOND'" Roof Tile Adhesive I
FL22525
Boral TileSealHT
ICP Adhesives Polyset° AH-160 I
FL6332
Boral TileSealHT
ICP Adhesives Polyset® RTA-1 I
FL6276
Boral TileSealHT
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck: I
Citadel Plus, Boral TileSeal 50HT, Boral TileSealHT
➢ Plywood (unprimed or primed with ASTM D
Boral TileSealHT:
➢ OSB primed with ASTM D41 primer.
Note: Refer to Section 5.6.4 for uplift limitations
where the overlying roof cover is adhesive -set tile II
5.6.2 Bond to Base Laver Underlayment:
Citadel Plus, Boral TileSeal 50HT, Boral TileSealHT
➢ ASTM D226, Type II felt; Citadel Plus.
For installations under mechanically attached pri
minimum codified requirements. For installatioi
attached per minimum requirements of FRSA/TRI
Section 5.6.4 herein, or as tested in accordance wl
or GatorSeal:
41 primer).
associated with direct -deck underlayment installations
GatorSeal:
Ired roof coverings, base layer shall be attached per
under adhesive -set tile systems, base layer shall be
Aril 2012 (04-12), Appendix A, Table 1, or as listed in
FBC 1504.3.1.
' Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design, I.I.C. Evaluation Report M35730.12.10-R9
Certificate ofAuthori:otion #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.14317-118
Boral Roof Underlayments; (602) 269-2288 Revision 9:10/14/2017
Page 3of7
QOTRINITYIERD
5.6.3 Bond to Other Substrate Types:
Citadel Plus, Boral TileSeal 50"T, Boral Tile Sea l"T or GatorSeal:
➢ ASTM D41 primed metal (e.g., flashing metal, valley metal, etc).
Boral TileSeal"T:
➢ Huber Zip Deck (unprimed or primed with ASTM D41 primer); Dens Deck Prime.
Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached
per minimum requirements of the prepared'roof covering manufacturer's Product Approval.
5.6.4 Wind Resistance for Underlayment Systems in Adhesive -set Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath adhesive -set tile systems,
where the underlayment forms part of the load -path. The following wind uplift limitations apply to
underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in adhesive -set
tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety
per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or
FBC 1609 for determination of design wind loads
#1 Maximum Design Pressure = -105 psf:
Deck: Min. 15/32-inch plywood io meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Ply: (Optional) Citadel Plus, self -adhered
Underlayment: Boral TileSeal"T, self-adhereId and back -nailed within the selvedge -edge side laps using
12 ga. x 1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
#2 Maximum Design Pressure = -120.0 psf:
Deck: Min. 15/32-inch plywood to
meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: ASTM D41 to the plywood deck
Base Ply: Citadel Plus, self -adhered
Cap Sheet: Boral TileSeal"T, self -adhered and back -nailed within the selvedge -edge side laps using
12 ga. x 1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
#3 Maximum Design Pressure = -202.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: ASTM D41 to the plywood dec(C
Base Ply: None I
Cap Sheet: Boral TileSeal"T, self -adhered, and back nailed within the selvedge -edge side laps using
12 ga. x 1'/<" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch D.C.
#4 Maximum Design Pressure = -120.0 psf:
Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of
Authority Having Jurisdiction.
Primer: ASTM D41 to the concrete deck
Base Ply: (Optional) Citadel Plus, self -adhered
Cap Sheet: Boral TileSealHT,
self-adhered
5.6.4.1 Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the
project design pressure requirements may not exceed -120 psf.
Exterior Research and Design, I.I.C. Evaluation Report M35710.12.10-R9
Certificate ofAuthori:ation #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R8
Boral Roof Underlayments; (602) 269-2288 Revision 9:10/14/2017
Page 4 of 7
M
QOTRINITY�ERD
5.7 Exposure Limitations:
GatorSeal shall not be left exposed for longer than 30-days after installation, prior to placement of final
roof cover.
Boral TileSeal SORT and Boral TileSeal"T shall not be left exposed for longer than 180-days after
installation, prior to placement of final roof cover.
Citadel Plus, for use as a base -layer in a two -'ply underlayment system, shall not be left exposed for longer
than 180-days after installation, prior to placement of subsequent underlayment layer.
5.8 Tile Slippage Limitations 1FRSA/TRI April 2012 (04-12)1:
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall
be as follows. These slope limitations can on, ly be exceeded by using battens during loading of the roof
tiles.
TABLE 2: TILE'SLIPPAGE LIMITATIONS FOR CT "DIRE -DECK TILE`INSTALLATIONS
Underlayment
Tile Profile
j Stagging Method
Maximum Slope
Boral TileSeal"T
Flat
l Max. 10-tile stack
6:12
Lugged
Max. 10-tile stack
6:12
6. INSTALLATION:
6.1 Boral Roof Underlayments shall be installed in accordance with Boral Roofing published installation
instructions subject to the Limitations set forth Iin Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check I or protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Install self -adhering underlayment when amble nI t and surface temperatures are minimum 40°F and rising.
6 4 Citadel Plus: '
6.4.1 Citadel Plus is limited to use as a base or mid -layer in multi -ply underlayment systems beneath Boral
TileSeal 50HT, Boral TileSeal HT or GatorSeal.
6.4.2 Slope limitations are those associated with the top -layer underlayment.
6.4.3 Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof
edge, extending over by %-inch. Fold the membrlane away from the edge onto itself. Remove the release
sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place.
Roll into place with a weighted roller.
Boral recommends fastening of the top edge of the sheet to the deck with roofing nails, nails & tin -tags or
1-inch diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for
slopes 7:12 and greater. Overlap successive courses minimum 2 inches (horizontal lap) and minimum 4"
end (vertical) laps.
Install final underlayment layer atop Citadel Plus per 'direct -to -deck' instructions for Boral TileSeal 50"T,
Boral TileSeal"T or GatorSeal.
6.4.4 To Base Sheet:
Install base sheet of ASTM D226, Type II felt in accordance with Code requirements or install base ply of
Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4.3 and
when used as part of a multi -ply system.
Install optional Citadel Plus as a mid -ply in al cordance with Boral Roofing published installation
instructions and Section 6.4.3.
Install final underlayment layer atop Citadel Plus per 'direct -to -deck' instructions for Boral TileSeal 50"T,
Boral TileSeal"T or GatorSeal. i
Exterior Research and Design, I.I.C. I Evaluation Report M35710.12.10-R9
Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R8
Boral Roof Underlayments; (602) 269-2288 Revision 9: 10/14/2017
Page 5 of 7
i
TRINITY IERD
Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the
project design pressure requirements may not exceed -120 psf.
ra -
6.5.1 Shall be installed in compliance with the requirements for AST l
M D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering ';to be installed.
6.5.2 Do not use Boral TileSeal 50HT on roof pitches less than 2:12.
6.5.3 Non -Tile Applications, Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof
edge, extending over by %-inch. Fold the membrane away from the edge onto itself. Remove the release
sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place.
Roll into place with a weighted roller.
Boral recommends fastening of the black selvedge edge to the deck with roofing nails, nails & tin -tags or 1-
inch diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes
7:12 and greater. Overlap successive courses the width of the black -selvedge area, minimum 3-inch.
Seal under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet
Seam method detailed in Boral Roofing published installation instructions.
6.5.4 Non -Tile Applications, to Base Sheet:
Install ASTM D226, Type II felt in accordance wit Code requirements or install Citadel Plus in accordance
with Boral Roofing published installation instructions and Section 6.4.
Install Boral TileSeal 50HT in accordance over ASTM D226, Type II felt or Citadel Plus with Boral Roofing
published installation instructions and Section 6.5.3, except end (vertical) laps, described below.
Apply SBS Mastic under all end (vertical) laps Ior any other laps where the self -adhering bituminous
underside is in contact with the fabric top surface, rolling the interface into place with a weighted roller.
6.6.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
6.6.2 Do not use GatorSeal on roof pitches less than 2:12.
6.6.3 Non -Tile applications, Direct to Deck:
Cut the membrane into manageable lengths, typicI
ally 10 to 12 ft. Align the membrane parallel to the roof
edge, extending over by %-inch. Fold the membrane away from the edge onto itself. Remove the release
sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place.
Roll into place with a weighted roller.
Boral recommends fastening of the black selvedge edge to the deck with roofing nails, nails & tin -tags or 1-
inch diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes
7:12 and greater. Overlap successive courses the width of the black -selvedge area, minimum 3-inch.
Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps where the self -
adhering bituminous underside is in contact with tIhe granular or mineral top surface, rolling the interface
into place with a weighted roller, or using the Inverted Sheet Seam detailed in Boral Roofing published
installation instructions.
6.6.4 Non -Tile Applications, to Base Sheet:
Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance
with Boral Roofing published installation instructions and Section 6.4.
Install GatorSeal over ASTM D226, Type II felt or Citadel Plus in accordance with Boral Roofing published
installation instructions and Section 6.6.3 except end (vertical) laps, described below.
Apply SBS Mastic under all side (vertical) laps or any other laps where the self -adhering bituminous
underside is in contact with the granular top surface, rolling the interface into place with a weighted roller.
Exterior Research and Design, U.C. Evaluation Report M35710.12.10-R9
Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-118
Boral Roof Underlayments; (602) 269-2288 Revision 9:10/14/2017
Page 6 of 7
",JTr.JERD
INITY
6.7.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to; be installed.
6.7.2 Do not use Boral TileSeal HT on roof pitches less than 2:12.
6.7.3 Non -Tile Applications, Direct to Deck:
For OSB substrate, prime with ASTM D41 primer and allow to dry prior to installation. Cut the membrane
into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending
over by %-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the
membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place
with a weighted roller.
Boral recommends fastening of the black selvedge) edge to the deck with roofing nails, nails & tin -tags or f-
inch diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes
7:12 and greater. Overlap successive courses the x ridth of the black -selvedge area, minimum 3-inch.
Seal under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet
Seam method detailed in Boral Roofing published installation instructions.
6.7.4 Non -Tile Applications, to Base Sheet:
Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance
with Boral Roofing published installation instructions and Section 6.4.
Install Boral TileSeal HT over ASTM D226, Type I; felt or Citadel Plus in accordance with Boral Roofing
published installation instructions and Section 6.7.3, except end (vertical) laps, described below.
Apply SBS Mastic under all end (vertical) laps Or any other laps where the self -adhering bituminous
underside is in contact with the fabric top surface, olling the interface into place with a weighted roller.
6.7.5 Tile Applications:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top
sheet(s), Base Sheet fastening shall be not less tha6 FRSA/TRI April 2012 (04-12), Table 1.
For adhesive -set tile applications, refer to Section 5.6.4 herein.
Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the
project design pressure requirements may not exceled -120 psf.
Refer to Section 5.8 for tile staging limitations. Battens must be used for all tile installations atop Boral
TileSeal HT with roof pitches of 2% to less than 3:12. Boral Roofing's Elevated Batten System or counter
battens are required.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACiURING PLANTS:
Brentwood, NH
9. QUALITY ASSURANCE ENTITY:
UL, LLC. — QUA9625; (631) 546-2458; I<anchi.ARrawala-Dokania@ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, I.I.C. Evaluation Report M35710.12.30-R9
Certificate ofAuthori:ation #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.14317-118
Boral Roof Underlayments; (602);269-2288 Revision 9:10/14/2017
Page 7 of 7