HomeMy WebLinkAboutPRODUCT APPROVAL SHUTTERS ACCORDION_ J
SCANNED
By y
Business o o ',v o t
BCIS Home I Log In 1 User Registration Hot Topics Submit Surcharge Stats& Facts 1 Publications 'FBC Staff BCIS Site Map Links Search
Florida
all Product Approval
.USER: Public User
Product Approval Menu > Product or Application Search> Application List> Application Detail
FL # FL389-119 RECEYVE®
Application Type Revision
Code Version 2017 MAR 1 2 2010
Application Status Approved
Permitting Department
Comments St. Lucie County
Archived ❑
Product Manufacturer American Shutter Systems Association, Inc.
Address/Phone/Emall 4268 Westroads Drive
West Palm Beach, FL 33407
(561) 209-8263
bfeeley@easternmetal.com
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Bill Feeley
lrodriguez@easternmetal.com
Shutters
Accordion
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Walter A.. Tillit, Jr. P.E.
the Evaluation Report
Florida License PE-44167
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2018
Validated By John Henry Kampmann Jr.
0 Validation Checklist - Hardcopy Received
Certificate of Independence FL389 R9 COI AMERICAN SHUTTER SYSTEM ASSOC.. INC. DRAWING
17-107 CERTIFICATE OF INDEPENDENCE.PDF
FL389 R9 COI AMERICAN SHUTTER SYSTEMS ASSOC., INC.
DRAWING 17-106 CERTIFICATION OF INDEPENDENCE fl).PDF
FL389 R9 COI AMERICAN SHUTTER SYSTEMS DRAWING 17-108
CERTIFICATE OF INDEPENDENCE.PDF
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Standard
ASTM E-1886
ASTM E-1996
ASTM E-330
TAS 201, 202, 203
FIL�F COPV
Year
2005
2005
2002
1994
Sections from the Code
Product Approval Method
Method 1 Option D
Date Submitted 09/18/2017
Date Validated 10/18/2017
Date Pending FBC Approval 10/19/2017
Date Approved 12/12/2017
Summary of Products
FL # Model, Number or Name Description
389.1 Bertha HV Accordion Shutter -
Blade 3 - (Non-HVHZ) - Drwg 17-
108
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other, Large Missile Level "D".Max span is 12'-3" for 40 psf
positive ASO load and 13'-0" for 35 psf negative;ASD load
the HV3 blade w/o window blade,5'-2" for 110 psf ASD load
for HV3 blade w/o window blade and 8'-11" for 62 psf, 9'-11"
for 55 psf HV3 blade w/window blade working inl
unison.Max.span for HV3 blade w/o window blade for
installations into Metal Stud walls is 79" for max, ASD
pressure rating of +72,-72 and 84" for +64,-64 psf. See
meet 5 for other spans and AS .
Extruded aluminum interlocking blades retained by tracks
(top and bottom) for storm protection
Installation Instructions
FL389 R9 II AMERICAN SHUTTER SYSTEMS DRAWING
17-108 BERTHA HV ACCORDION SHUTTER SYSTEM.PDF
Verified By: American Test Lab of South Florida Inc.
Created by Independent Third Party: Yes
Evaluation Reports
FL389 R9 AE AMERICAN SHUTTER SYSTEMS DRAWING
Created by Independent Third Party: Yes
389,2 Bertha HV Accordion Shutter -Blade Extruded aluminum interlocking blades retained by tracks
1 Only- (Non-HVHZ)- Drwg 17-107 1 (top and bottom) for storm protection
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Large missile level "D". Max. Span is 16'-0" for 30
p.s.f negative ASD load depending on centermates and
locking rod configuration for the HV1 blade, 8'-0" for +64, -
72 p.s.f. A.S.D. load for HV blade for Keystone mountings
7'-0" p.s,f, for metals stud mountings and 8'-0" for 110 p.s.f
for HVSA working in unison. See sheets 7, 11 and 20
respectively of installation drawings for other spans and
pressures.
Installation Instructions
FL389 R9 II AMERICAN SHUTTER SYSTEM ASSOC..
INC. DRAWING 17-107 BERTHA HV ACCORDION SHUTTER
SYSTEM.PDF
Verified By: American Test Lab of South Florida Inc,
Created by Independent Third Party: Yes
Evaluation Reports
REPORT.PDF
Created by Independent Third Party: Yes
389.3 Bertha HV Accordion Shutter- Extruded aluminumintertCkMVt95Ues retained by tracks
COMBO- (Non-HVHZ)- Drwg 17-106 1 (top and bottom) for storm protection
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Large missile. Max, 16'-0" span at 30 p.s.f ASD load
for Blade 1 and 18'-0" for Blade 2. See schedules on sheet
12, 25 and 28 respectively
Installation Instructions
FL389 R9 II AMERICAN SHUTTER SYSTEMS ASSOC.. INC.
DRAWING 17-106 BERTHA HV ACCORDION SHUTTER
SYST. PDF
Verified By: American Test Lab of South Florida Inc.
Created by Independent Third Party: Yes
Evaluation Reports
FL389 R9 AE AMERICAN SHUTTER SYSTEMS ASSOC.,
INC. DRAWING 17-106 PRODUCT EVALUATION
REPO RT. PD F
Created by Independent Third Party: Yes
Beck Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Coovrioht'2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455,F.S. must provide the Department with an email address If they have one, The
emaiis provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the. Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter455, F.S., please
click here .
Product Approval Accepts: