PROJECT INFORMATION
- - wrightsofte Load Short Form House Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: SCANNED BY For: Basile Residence, Air Conditioning Unlimited TBD Wind Trail, Fort Pierce, FL 34981 Job: 1316 Date: Sep 09, 2020 By. Chris Bateman MAP 1,9 7021 Permitting Department St, Wcle County Outside db (OF) Inside db (OF) Design TD (OF) Daily range Inside humidity (%) Moisture difference (grAb) Htg 41 70 29 - 30 2 Clg 90 75 15 L 50 57 Infiltration Method Construction quality Fireplaces Simplified Average 0 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Goodman Mfg. Trade Trade GOODMAN Model Cond GSX16S301A AHRI ref Coil ASPT39C14A AHRI ref 201785799 Efficiency 100 EFF ' I Efficiency 13.0 EER,15.5 SEER Heating input 5.6 kW Sensible cooling 19600 Btuh Heating output 19234 Btuh Latentcooling 8400 Btuh Temperature rise 19 OF Total cooling 28000 Btuh Actual airflow 933 cfm Actual airflow 933 cfm Airflowfactor 0.051 cfm/Btuh Airflowfactor 0.050 cfmBtuh Static pressure 0.70 in H2O Static pressure 0.70 in H2O Space thermostat i Load sensible heat ratio 0.78 ROOM NAME Area W) Htg' load (Btuh) Clg load (Btuh) Htg AVF (cfm) CIg AVF (cfm) Bed 3 153 2844 1950 145 97 Bed 2 154 2624 2256 134 113 Utility 48 862 1096 44 55 Clst 6 0 0 0 0 Bath 61 603 346 31 17 Master Bed 226 3337 2729 170 136 Great Room 238 2967 3236 151 162 Wardrobe 30 53 103 3 5 Master Bath 72 693 370 35 18 Kitchen 241 4331 6598 221 330 u,.n 7r- n n n n Get Calculations approved byACCAto meet all requirements of Manual J 8th Ed flll a' .�„ wrightsott® 2020-Sep-09 14:15:47 Righ[Sate®Universal 201919.020RSU29066 Paget Ws �+�...aunerds\WrigoftHVAC\TBDWirdTrail,PSLnp Calc=MJ8 Front Door faces: N House S 1303 18314 18684 933 933 Other equip loads 1371 728 Equip. @ 0.95 RSM 18519 Latent cooling 5448 -r 1303 19685 23967 9314 011 OTAL� Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrightsoft- 2020-Sep-0914:15A7 . .MZ�.w�-.,, Right-Sute®Urtversal201919.020RSU29066 Paget +�...aenerrtsUrigtfsoftHVAQTBDWind Trail, PSL.rLp Calc=MJ8 FrortDoorfaces: N Building Analysis Job: 1316 wrightsoft° g Date: Sep 09, 2020 House By. Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: viddlynrie@aircalcs.com For: Basile Residence, Air Conditioning Unlimited TBD Wind Trail, Fort Pierce, FL 34981 Location: Indoor: Heating Cooling St Lucie Co Intl, FL, US Indoor temperature (°F) 70 75 Elevation: 26 ft Design TD (°F) 29 15 Latitude: 28°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (grAb) 2.4 56.9 Dry bulb (°F) 41 90 Infiltration: Daily range°F) - 15 (L ) Method Simplified Wet bulb (°) - 77 Construction quality Average IArn,4 --A /-M 1 r. /) 7 F. M-1-- n Component Btuh/ft2 Btuh %ofload Walls 3.2 3244 16.5 Glazing 17.4 2606 13.2 Doors 3.7 75 0.4 Ceilings 1.0 1291 6.6 Floors 3.3 4302 21.9 Infiltration 2.1 2491 12.7 Ducts 4305 21.9 Piping 0 0 Humidification 0 0 Ventilation 1371 7.0 Adjustments 0 Total 19685 100.0 Component Btuh/ft2 Btuh % of load Walls 2.0 2075 10.7 Glazing 25.4 3805 19.6 Doors 3.7 76 0.4 Ceilings 1.8 2351 12.1 Floors 0 0 0 Infiltration 0.6 676 3.5 Ducts 5581 28.8 Ventilation 728 3.8 Internal gains 4120 21.2 Blower 0 0 Adjustments 0 Total 194121 100.0 Latent Cooling Load = 5448 Btuh Overall U-value = 0.104 Btuh/ft2--°F Data entries checked. Floors Infiltration Gains -rk- wrlightsoft® 2020-Sep-0914:15.47 �� ^d• �w�--�� Right-Sute®Unlversal 2019 19.020 RSU29066 Page 1 A ...amerts0rigftsoftWAC\TBD Wind Trail,PSLnQ Calc=MJ8 Front Door faces: N - - wrightsofto Component Constructions House Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone:772.800.8413 Emai1:vim1yme@aircalcs.com For: Basile Residence, Air Conditioning Unlimited TBD Wind Trail, Fort Pierce, FL 34981 Job: 1316 Date: Sep 09, 2020 By. Chris Bateman Location: Indoor: Heating Cooling St Lucie Co Intl, FL, US Indoor temperature (°F) 70 75 Elevation: 26 ft Design TD (°F) 29 15 Latitude: 280N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (grAb) 2.4 56.9 Dry bulb (°F) 41 90 Infiltration: Daily range (°F) - 15 (1-1 Method Simplified Wet bulb (°F) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces i 0 Construction descriptions or Area uaralue ft' Btuh/ftk'F Walls Blk Wall, Stucco Ext, R-4.1 Ext Bd inl, 8" Thk, 112" Gyp Bd Int Fnsh ne 189 0.109 se 344 0.109 sw 184 0.109 hw 313 0.109 all 1030 0.109 Partitions (none) Windows Impact, Clear Lowe: Impact, Clear Lowe; NFRC rated (SHGC=0.24); ne 16 0.580 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 4 ft overhang (5.2 ft window ht, 1 ft sep.); 6.8 ft head ht Impact, Clear Lowe: Impact, Clear Lowe; NFRC rated (SHGC=0.24); ne 31 0.580 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 6 ft overhang (5.2 ft window ht, 1 ft sep.); 6.8 ft head ht Impact, Clear Lowe: Impact, Clear Lowe; NFRC rated (SHGC=0.24); sw 31 0.580 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.2 ft window ht, 1 ft sep.); 6.8 ft head ht nw 31 0.580 all 62 0.580 Impact, Clear Lowe: Impact, Clear Lowe; NFRC rated (SHGC=0.21); sw 41 0.650 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (6.8 ft window ht, 1 ft sep.); 6.8 ft head ht Doors Fbrgls Door Ceilings Attic, Shngls, R-30 Ceil Ins, 1/2" Gyp Bd Int Fnsh Insul R Htg HTM Loss Clg HTM Gain ftz°F/Btuh BLOW Stuh BLOW Btuh 5.1 3.15 595 2.02 381 5.1 3.15 1084 2.02 693 5.1 3.15 580 2.02 371 5.1 3.15 986 2.02 630 5.1 3.15 3244 2.02 2075 0 16.8 262 22.6 353 0 16.8 525 22.6 706 0 16.8 525 21.8 681 0 16.8 525 22.6 706 0 16.8 1050 22.2 1387 0 18.8 769 21.6 880 ne 20 0.127 7.0 3.69 75 3.73 76 1303 0.034 30.0 0.99 1291 1.80 2351 wrightsoft® 2020-Sep-0914:15:48 �. u.• a a« ,�� , RightSute®Universal 2019 19.020 RSU29066 Page 1 �iiCA...aunentslWrigWoftHVAC\TBDWindTrail, PSL.np Calc=MJB FrontDoorfaces: N wrightsofte Project Summary House Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: For: Basile Residence, Air TBD Wind Trail, Fort Notes: in $nlimited Job: 1316 Date: Sep 09, 2020 By. Chris Bateman Weather: St Lucie Co Intl, FL, US Winter Design Conditions Summer Design Conditions Outside db 41 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 29 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 57 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 14009 Btuh Structure 13103 Btuh Ducts 4305 Btuh Ducts 5581 Btuh Central vent (43 cfm) 1371 Btuh Central vent (43 cfm) 728 Btuh Outside air Outside air Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 19685 Btuh Use manufacturer's data n Rate/swingg multipplier Equipmentsensible load 0.95 18519 Btuh Infiltration Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2344 Btuh Ducts 1442 Btuh Central vent (43 cfm) 1663 Btuh Heating Coolingg Outside air Area (ft2) 1303 1303 Equipment latent load 5448 Btuh Volume (f? 10420 10420 Air changes/hour 0.45 0.23 Equipment Total Load (Sen+Lat) 23967 Btuh Equiv AVF (cfm) 78 40 Req. total capacity at 0.70 SHR 2.2 ton Heating Equipment Summary Cooling Equipment Summary Make Make Goodman Mfg. Trade Trade GOODMAN Model Cond GSX16S301A AHRI ref Coil ASPT39C14A AHRI ref 201785799 Efficiency 100 EFF Efficiency 13.0 EER,15.5 SEER Heating input 5.6 kW Sensible cooling 19600 Btuh Heating output 19234 Btuh Latentcooling 8400 Btuh Temperature rise 19 OF Total cooling 28000 Btuh Actual airflow 933 cfm Actual airflow 933 cfm Airflowfactor 0.051 cfm/Btuh Airflowfactor 0.050 cfmBtuh Static pressure 0.70 in H2O Static pressure 0.70 in H2O Space thermostat Load sensible heat ratio 0.78 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. C -rk wriGhtsoft® 2020-Sep-0914:15:48 ACCK Right-sute®Universal 2019 19.020 RSU29066 Page 1 ..amends\WriglisoftHVAC1TBDWindTrail,PSL.rLp Calc=MA Front Door faces: N -�- wrightsoft, Right-J® Worksheet 1 Job: 1316 House Date: Sep 09, 2020 By. Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone:772.800.8413 Email:vcldlynne@ai,calcs.com 1 2 3 4 5 Room name Bposed wall Room height Room dimensions Room area House 1 150.0 It 8.0 ft 1 1302.5 ft' Bed 3 25.5 ft 8.0 ft heat/cool 1.0 x 153.3 ft 153.3 T Ty Construction number U-value (Btuh/ft? °F) Or HTM (Btuhflt) Area or (ftz) perimeter (ft) Load (Btuh) Area (ft') or perimeter (ft) Load (Btuh) Heat Cool Gross NIPS Heat Cool Gross N/P/S Heat Cool 6 11 W - Blk Wall, Stuii6tid p_ 'impact mpad,ClearLowe Fbpa(s Cle r Lowe Blk Wall, Stucco E)d Blk Wall, Stuoco tR - ImpaaClear Lowe Impact,_GlearLdw-e-- Blk Wall, Sturm Ext Impact, Clear Lowe _ . Attie Shngls R 30�-0 OnGrade_Depth Tile - 0.109 0.0.580 0.580 0.109 0.109 0.580 0.650 0.109 ._0.580 __0.989 -j_--� _. _ _--. - _ : _-.-_ �_ 381 706 706 _. _ 693 371 681 ._ .. 880 630 _ _ ._706 _ _ _23-51. ____ __ 88 16 0 116 _ 0 0 _.. 72 0 0 116 _a.W_ __.e 0 0 .._ -___ 0 � . -__ _1,53 228 262 0 365 __ 0 0, _.v_. ..._6 0 0 __.._ _152 ___731„ 146 353 0 234 0 0 _____-- 0 0 .-_-.o ne ne rie _ _ne se sw sw - sw nw _nw.____16.82 i 3. 55 16.82 13 6.9.. 3.15 - 3.15 16.82 �18.85 3.15 99 -. 28,68. __ 2.02 2264 __ 3-03 2.02 2:02 21.82 21.56 2.02 ..-22.64 _ 1:80 -__9:00 256 31 � 31' 20 . 344 256 31 41 : 4a 31 • 1303 _1303 _ _._ 189 0 0 20 344 ___ _ ._ 164 4 _4 313 m. 0 __. -1303 -----__,150-.26 _ �_,.__ 595 262 525 _ 75,-- 1084 ._-. _-- 580 525 :_ _ -__ 769 986 - Y 525 _._.__.1291 W L-G t-_ G C-_.. _ F_ -___ 0 0 --- - 153 6 c) AED excursion 478 -30 Envelopeloss(gain 1 11518 8307 1739 980 12 a) Infiltration b) Room ventilation 2491 0 676 0 423 0 115 0 13 Internal gains: Occupants @ 230 Applianoes/other 4 920 3200 0 0 250 Subtotal (lines 6 to 13) 14009 13103 2163 1345 14 15 Less external load Less transfer Redistribution Subtotal Ductloads 31% 43% 0 0 0 14009 4305 0 0 0 13103 5581 31% 43% 0 0 13 2175 668 0 0 23 1367 582 Total room load Airrequired (ctm) j 18314 933 18684 933 2844 1451 1950 97 i Calculations approved byACCAto meet all requirements of Manual J 8th Ed. i�t- wrfightsoTt� 2020-Sep-0914:15:48 Right-SritecUriversal 2019 19.020 RSU290661 Page 1 cunerts\WrightsoftHVAC\TBDWirid Trail, PSL.nQ Calc=MJ8 FrontDoorfaces: N -I�- wrightsoft Right-J® Worksheet Job: 1316 House Date: Sep 09, 2020 By. Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone:772.800.8413 Email: vicldlyme@aircaks.com 1 2 3 4 5 Room name Exposed vuall Room height Room dimensions Room area Bed 2 20.0 ft 8.0 ft heaticool i 11.0 x 14.0 ft j 154.0 ft' Utility 8.5 ft 8.0 ft head ool 6.0 x 8.0 ft 48.0 ft2 Ty Construction number U-value (BtuhAN--°F) Or HTM (BtuhAt2) Area or (ft-) I perimeter (ft) Load (Btuh) Area (ft) or perimeter (ft) Load (Btuh) Heat Cool Gross NrP/S Heat Cool Gross NIPS Heat Cool 6 11 Blk Wall, Stucoo E)d Impact, Clear Lower Impact, Clear Lowe F_brgls Door - BlkWall ,§gccoEq - - Blk Wall, Stucco E)d Impad,Clear Lowe Impact Clear Lowe - - Blk Wall, Stucco E)d ImppgClear Lowe._ A1fG Sbngls, R 30 .. On_GradeDepih,Tile _ _ 0.109 0.580 0.580 - 0127 - - `--0.109 0.109 0.580 - 0.650-,sw 0.109 --_--_0.580_-nw_ - -0:034 0.989 ne ne ne ne --se- sw sw nw - _ - __- - 3.15 16.82 16.82 _ _ 3.69 ----3.15 3.15 16.82 --- -18.85 3.15 2.02 22.64 22.64 _ _ 3.73 --- 2.02 2.02 21.82 211.56 2.02 _._ 22.64 88 0, 31 _ _0 -- 0 0 0 _ ._ _. - 6 72 __.-o _._ : - 154 --- -_154 i 57 , 0 0 -- - - �... -----_----0 0 0 - .._.. -0 72 - _------ 0 - -154 _ _ ___20 179 0 525 -- ------ 0._-_..--- 0 0 ._ . - 227 _._____0 --- -1 53 --- -574 114 0 706 - - - 0 0 0 - - -0 145 -- 278 -. _.----0 48 0 0 - - - 0 - - 0 0 0 -- -0 20 _ _---0 .__--- --48 --- ---`48 48 0 0 - - - 6, _. _ 0______ 0 0 -- --- - 0 20 .--.. 0 - -.--48 __-- -- _ 9 151 0 0 - - - - 0 0 0 0 -- ... -0 63 -------0 _ - 48 .-- --244` 97 0 0 - - ------- -0- 0 0 40 -_ ._ 87 --- -0_ W _ �G -- V�J 1-G C-- ._ _F_ -_16.82 -- - 0.99 . 28.68 _ -1.80 _--- 0.00 6 c) AED excursion -34 -17 Envelope losslgain 1657 1210 506 207 12 a) Infiltration b) Room ventilation 332 0 90 0 141 0 38 0 13 Intemalgains: Occupants@ 230 Appliances/other 0 0 250 0 0 500 Subtotal (lines 6 to 13) 1989 1550 647 745 14 15 Less external load Less transfer Redistribution Subtotal Ductloads 31% 43% 0 0 18 2007 617 0 0 32 1582 674 31% 43% 0 0 13 660 203 0 0 23 768 327 Total room load Airrequired (clm) 2624 134 2256 1131 862 44 1096 55 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -+{.� 2020-Sep-0914:15A8 ACCA. RightSute@)Universal 20l9 19.020 RSU29066 Page 2 amer9sUrigltsoftHVAC\TBDWindTrail, PSLxLp Calc=MJ8 FrontDoorfaces: N -�- wrightsoft, Right-J®'Worksheet House Job: 1316 Date: Sep 09, 2020 By. Chris Bateman Air Calcs, LLC i 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone:772.800.8413 Email: vicldlynrie@aircalcs.com 1 Room name Clst Bath 2 3 Exposed wall Room height 0 It 8.0 ft heatIcool 5.5 It 8.0 ft heaV000l 4 5 Room dimensions Room area 2.5 x 2.5 It 6.3 ft' 11.0 x 5.5 It 60.5 ft' Ty Construclion number 1-1-value (BtuhiT--'F) Or HTM (BtuW) Area orl (ft') perimeter (ft) Load (Btuh) Area (ft') or perimeter (ft) Load (Btuh) Heat Cool Gross N1P/S Heat Cool Gross N/P/S Heat Cool 6 11 G Blk Wall, Stucco Ext ImpaMClear Lowe Impac,Clear Lowe FbrglsDoor - _ Blk Wall, Stucco Ext Blk Wall, Stucco Ext Impact, Clear Lowe Impact Clear Lowy BlkWall,L _Lcco Ext Impact,ClearLow-e- -- AtiG Shngls, R_30 0.109 0.580 0.580 Q_127 0_109 0.109 0.580 0.650 _-0.109 0.580 0:034 ne ne ne -n2 _ se sw sw _ sw nw nw 3.15 16.82 16.82 _ 3.69 3.15 3.15 16.82 18.85 3.15 16.82 0,99 2.02 22.64 22.64 - - 3.73 _ . - 2.02 2.02 21.82 21.56 - 2.02 22.64 0 0 0 - -0 0 0 0 0 _ O 0 6 0 0 0 -- -- 0 0 0 0 0 - 0 6 0 0 0 --- 0 0 0 0 0 _ - .__6 0 0 0 - 0 0 0 0 - -0 0 0 _ 11 0 0 0 - 0 44 0 0 0 0 0 _ 0 0 0 --- - _ 44 0 0 _ _ 0 0 0 0 0 0 - - .0---- 139 0 0 _ _ _.---__ 0 0 _ 0 0 0 0 - 89 0 0 _ -.- 0 0 _ 0 :G -- - W _ -G V1/��11 _t • G, C_., - _ - On Grade Depth Tile -- --- _ _---- 0.989 . _ - _ - __-_ 28.68. _ _--1.80 _ _ _ 0.00.... -- - _ .. 6 - p _ -- _.0 _ ._0 . ---- 61. _ -. -- . 6 - � � _ -- --- - 0- 6 c) AED excursion 0 -5 Envelope loss/gain 6 11 356 193 12 a) Infiltration 0 0 91 25 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Applianoes/other 0 0 Subtotal (lines 6 to 13) 6 11 448 218 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -6 -11 14 25 14 Subtotal 0 0 462 242 15 Ductloads 31% 43% 0 0 31% 43% 142 103 Total room load 0 0 603 346 Air required (dm) 0 01 31 17 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �r wr7gF�tsoTt� 2020-Sep-0914:15:48 RigllSUte0Uruversal201919.020RSU29066 Page ...aunents\WrigltsoftHVAC\TBDWind Trali,PSL.np Calc=MJ8 Front Door faces: N �+ wrightsoft® RighW@ Worksheet Job: 1316 House Date: Sep 09, 2020 By. Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone:772.800.8413 Email: vcldlynne@ai'rcales.com 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Master Bed 30.0 ft 8.0 It heat/000l 1.0 x 226.3 It 226.3 ft- Great Room 22.5 ft 8.0 It heaV000l 1.0 x 237.8 ft 237.8 ft2 Ty Construction number U-value (Btuh/T--°F) Or HTM (Btuh/ft2) Area or (ft2) I perimeter (ft) Load (Btuh) Area (W) or perimeter (ft) Load (Btuh) Heat Cool Gross NAS Heat Cool Gross N/P/S Heat Cool 6 11 VV `'. Blk Wall, Stu000 E)d Impact, Clear Lovv a Impact, Clear Lowe FbrglsDogr Blk Wall, Stu000 Ext BIk WaII, Stu000 EiQ ImpaaClear Lowe. Impact, Clear Lowe- --e Blk Wall, Stumo E# Im a_ Clear Lowe _P _ _� _ -_ Qn_GradeDepth Tile._-.; 0.109 0.580 0.580 . _ 0.127 0.109 ___ - i.109 0.580 ---- 0.650 0.109 _ 0.580 .0,989. net ne ne one se sm sw sw �- 3.15 16.82 16.82 3;69.,- 3.15 2.02 22.64 22.64 _373 2.02 _ 2.02 21.82 _ 21.56 _ _ _ _ __ 0 0 0 _0 132 108 16 ._ .0 1 0 i_ -0 ,_226 �6 --_ _0 0 0 -- 0 132 _.. 92 2 _ ._ 0 0 0 --_ �.. _-__ _226 _..___.- 30 o 0 0 ._�-_0. 416 0 0 0 _ 0 266 32 0 0 -- ----20 T 0 0 0 12 0 0 - - 20 _ 0 0 0 117 0 _ _ _ 37 0 0 75 . _ _ o 0, 0 368 525 _.. _ . __._.. 236 -- v 23 0 0 -- - 76- _ 0 0 0 235 706 _ _ _ _ _.._ _. W -- G yJ �G _ 3.15 16.82 - 18.85 3.15 16.82 _ _16 _28,88 �-- 291 262 . .....'0 0 _ .. 0 __224_. w._860 -� 186 340 -- - -- 0 _ ,, 0 __ 408 - nw nw _ _. _c_. 2.02 22.64 _ 1.80 0.00 148 _ _ 31 -_ 238 _ _-_238 ___. -. --__- ..__ I 6 c) AED excursion 78 219 Envelope loss/gain 2054 1279 1886 1689 12 a) Infiltration b) Room ventilation j 498 0 135 0 374 0 101 0 13 Internal gains: Occupants @ 230 Appliances/other 1 0 0 500 2 460 0 Subtotal (lines 6 to 13) 2552 1914 2259 2251 14 15 Less external load Less transfer Redistribution Subtotal Ductloads 31% 43% 0 0 0 2552 784 0 0 0 1914 815 31% 43% 0 0 11 2270 698 0 0 19 2270 967 Total room load Air required (dm) 1 3337 170 2729 136 2967 151 3236 162 Calculations annroved bvACCAto (meet all requirements of Manual J 8th Ed. - wrGgF�ts-M- j 2020-Sep-0914:15:48 Right-SuteOUniversal 2019 19.020 RSU29066 Page 4 ..ornenMrighlsoftHVAQTBDWind Trail, PSLrLp Calc=MJ8 Front Door faces: N - wrightsoft® Right-J® Worksheet Job: 1316 House Date: Sep 09, 2020 By. Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beads, FL 32966 Phone: 772.800.8413 Email: vicldlynne@aircalcs.com 1 Room name Wardrobe Master Bath 2 E)posed wall 0 It 6.5 ft 3 Room height 8.0 It heatl000l 8.0 ft heaUcool 4 5 Room dimensions Room area 5.0 x 6.0 ft 30.0 ft- 11.0 x 6.5 It 71.5 ftz Ty Construction number U-value (Btuh/ft'' °F) Or HTM (BtuhAtz) Area (T) orl perimeter (ft) Load (Btuh) Area (ft-) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Blk Wall, Stucco Ext Impact, Clear Lowe Impact, Clear Lowe 0.109 0.580 0.580 ne ne ne 3.15 16.82 16.82 2.02 22.64 22.64 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TEG 11 Fbrgl_sDocr --- - -- Blk Wall, Stu000 EA 0,127 0.109 . ne . se 3$9_ 3.15 3.73 2.02 - 0 - Q _ -0 0 --- - -� 6 - - 52 - -- 0 52 - -0 164 --� --.. -- W V�1 E-G _ Blk Wall, SW000EQ ImpaMClear Lowe lmpact Clear Lowe-.-- -0.109 0.580 0.650 ~sw sw sw 3.15 16.82 18.85 _ 2.02 21:82 21_-56 0 0 .0 0 0 0 0 0 0 _ __ _ __ _ 0 0 - 0 _ 0 0 - -- 0 0 -- -0 - 0 0 - - - 0 _ _-_105 0 0 -- 0 �- y/ G Blk Wall, Stu000 E)d Impact Clear Lowe - -- 0.109 0.580 _ nw nw 3.15 16.82 2.02 22A . _ .L ._. 0 0 - 0 0 --- 0 0 - 0 - 0 _ 0 0 0 0 _0 0 _ ---. 0 C..._'_ F -- _ AttiGShngls._Rc30 _ _- On Grade Depth. Tile 0.034 __. _ 0.989 - = c -0.99 28.68 1.80 -- _ 0 00 _30 __.. .. _ 30 _ - 30 --- -- 0 -- - 30 _ G0 `4 ---- Q - 72 _ ..__ . 72 - 72 - _--- _7 - --71 _ _ ._ 186 - 129 __.. _ _0. 6 c) AED excursion -1 -6 Envelopeloss/gain 30 53 421 228 12 a) Infiltration 0 0 108 29 b) Room ventilation 0 0 0 0 13 Internal gains: Ooatpants@ 230 ; 0 0 0 0 Appliancestother 0 0 Subtotal (lines 6 to 13) 1 30 53 529 257 Less extemalload 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 11 19 1 2 14 Subtotal 40 72 530 259 15 Ductloads 31% 43%1 12 31 31% 43% 163 110 Total room load 53 103 F 693 370 Air required (dm) 3 51 1 35 18 Calculations approved bVACCAtO meet all requirements of Manual J 8th Ed. -*- wr➢gF��oft� R ght-Sute®Uruversal 2019 19.022020-Sep-0914:15:48 0 RSU29066 Page 5 ...amenMwrigh(softHVAQTBDWind Trail, PSL.rup Calc=MJ8 FrontDoorfaces: N - wrightsoftRight-J® Worksheet House Job: 1316 Date: Sep 09, 2020 By. Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vicldlwr)e@aircelcs.com 1 Room name Ntchen Hall 2 3 Exposed wall Room height 31.5 ft 8.0 ft heaVcool 0 It 8.0 ft heat/000l 4 5 Room dimensions Room area 18.5 x 13.0 It 240.5 ft- 1.0 x 74.5 It 74.5 ft Ty Construction number U-value (Btuh/F--'F) Or HTM (ewhAtz) Area (ft-) orl perimeter (ft) Load (Btuh) Area (T) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 Blk Wall, Stucco Ext Impact Clear Lowe Impact, Clear Lower Fbrgls Door - - Blk Wall, Stucco E:Q Blk Wall, Stucco E:d Impact, Clear Lowe Impac Clear Lowe----.. Blk Wall, Stucco EM Impad,Clear0.0 �---- AttcShnglsRc30___----0034_ 0.109 0.580 0.580 - - 2127 _ _ 0.109 0.109 0.580 ------_0.650 0.109 - - -0.580 ne , ne ne _ ne . se sw sw sw_ nw _nw- _- 3.15 16.82 16.82 _ . 3.69 3.15 3.15 16.82 ___ 1885 3.15 ---16.882 __..0.99. --- 2.02 22.64 22.64 - _ _3.73 _ 2.02 2.02 21.82 _- 21.56 2.02 - . 22.64 _..._1.80. --- f -- 6 0 i b _ _. _ .. - 0 0 - 148 R 16 _ _ 41 104 . _ 0 241 --- -- - -6 0 0 - - � 0 - 92 2 _- - - 4 104 ---0 ------_.241-- - --- -- o 0 0 - -- � 0 289 262 ----769,----_- 328 --- - 0 -238---- - ----- - o 0 0 - -0 0 -- 185 340 880 210 - ------ 0 434_----- _ --0 0 0 - - � 0 - 0 0 --- 6 0 ----- _6 75 0 0 - --- --0- 0 -- 0 0 -------- 0 0 --------75- 0 0 0 - -- 0 0 --.- - --0 0 ---- -74 0 0 -0 0 0 -6 0 -G L-GG _ W _ V�✓ �G -� yJ �G C__._ F-- -- On GradeDepih Tile._ _--__0.989 - ,_ ..__ ._28.68 -__0.00 . _i_-_241 ..__----. 32 903 0 -.--_- 75 --- -----0 -_-__-. _.0 _- __- ..0 6 c) AED excursion 277 -3 Envelope lossrgain 2790 2325 74 132 12 a) Infiltration 523 142 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 2 460 0 0 Appliances/other 1700 0 Subtotal (lines 6 to 13) 3313 4627 74 132 Less external load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 -74 -132 14 Subtotal 3313 4627 0 0 15 Dud loads 31% 43% 1018 1971 31% 43%1 01 0 Total room load 4331 6598 0 0 Air required (dm) 221 330 0 0 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. �}� wrightsoft 2020-Sep-0914:15:48 ��Righ[Stite®Uruversa1201919.020RSU29066 � Page ..cments%WrghtsoftHVAQTBDWird Trail, PSLn.p Calc=MJ8 Fror2Doorfaces: N -�- wrightsoft® Duct S Summary System .lab: Date: 1316 Sep 09, 2020 House By. Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vicldlyrrme@aircalcs.com For: External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Basile Residence, AirConditioriing Unlimited TBD Wind Trail, Fort Pierce, F 134981 Heating 10.70 in H2O 0 in H2O 10.70 in H2O 0.499 / 0.201 in H2O 6.315 in/100ft 1933 cfm 222 ft Cooling 0.70 in H2O 0 in H2O 0.70 in H2O 0.499 / 0.201 in H2O 0.315 in/100ft 933 cfm Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bat, h 603 37 21 0.317 4.0 Ox 0 VIFx 27.8 130.0 st4 Bed 2 h 2624 160 135 0.344 7.0 Ox 0 MFx 25.3 120.0 st3 Bed 3 h 2844 174 117 0.315 7.0 Ox 0 VIFx 28.6 130.0 st4 Great Room c 1618 91 97 0.455 5.0 Ox 0 VIFx 9.9 100.0 st1 Great Room -A c 1618 91 97 0.390 6.0 Ox 0 VIFx 18.2 110.0 st1 Kitchen c 3299 132 198 0.3.38 7.0 Ox 0 VIFx 22.8 125.0 st2 Kitchen -A c 3299 132 198 0.323 7.0 Ox0 VIFx 29.8 125.0 st2 Master Bail h 693 42 22 0.414 4.0 OxO MFx 15.8 105.0 st1 MasterBed-A h 1668 102 82 0.327 6.0 OXO VIFx 27.9 125.0 st2 Master Bed-B h 1668 102 82 0.326 6.0 Ox 0 VI Fx 28.0 125.0 st2 Way c 1096 53 66 0.335 5.0 Ox0 VIFx 28.9 120.0 St3 Wardrobe c 103 3 6 1 0.454 4.0 OxO MFx 10.0 100.0 st1 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 PeakAVF 469 559 0.323 712 12.0 0 x 0 VinIFIX st1 st3 PeakAVF 213 201 0.335 798 7.0 0 x 0 VinIFIX st1 st4 PeakAVF 211 138 0.315 604 8.0 0 x 0 VinlFlx st1 st1 PeakAVF 1120 1120 0.315 802 16.0 0 x 0 VnIFIX wrightsoft- 2020-Sep-09 14:15A8 �� ZA ...amer•w, "" . w ..-- Right-Sute®Universal 2019 19.020 RSU29066 Page 1 ts\WrigHzoftHVAC\TBD Wind Trail,PSL.rLp Calc=MJ8 Fror2Doorfaces: N Return Branch Detail Table Grille Htg Clg TEL Design ' Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox 0 578 698 40.1 0.500 500 16.0 Ox 0 VIFx rb4 Ox 0 207 170 63.7 0.315 469 9.0 Ox 0 M Fx rb2 Ox0 174 117 41.5 0.483 394 9.0 Ox 0 VIFx rb5 Ox 0 160 135 40.2 0.499 1 363 9.0 Ox 0 VIFx Boldlitalic values have been manually overridden - - wrightsoft°D 2020-Sep-0914:15:48 ANlvN/Bnbl.bvl4fMuyfvn{a.� RightSJte®UNversal 201919.020 RSU29066 l Page 2 ...aunerds\WrigHsoftHVAC1TBDWirrJTrail, PSL.np CaIc=MJB FrontDoorfaces: N -�- wrightsoft® Manual S Compliance Report Job: Date: 1316 Sep 09,2020 House By. Chris Bateman Air Calcs, LLC 7550 Hidden HammockLR Vero Beach, FL32966 Phone:772.800.8413 Email: vicldlynie@aircaks.00m For: Basile Residence, Air Conditioning Unlimited TBD Wind Trail, Fort Pierce, FL 34981 Cooling Equipment Design Conditions Outdoor design DB: 90.4°F Sensible gain: 19412 Btuh Entering coil DB: 77.0°F Outdoor design WB: 77.4°F Latentgain: 5448 Btuh Entering coil WB: 64.0°F Indoor design DB: 75.0°F Total gain: 24860 Btuh Indoor RH: 50% Estimated airflow: 933 ch Manufacturer's Performance Data at Actual Design: Conditions Equipmenttype: SplitAC Manufacturer: Goodman Mfg. Actual airflow: 933 ch Sensible capacity: 19600 Btuh Latent capacity: 8400 Btuh Total capacity: 28000 Btuh Model: GSX16S301A+ASPT39C14A 101 % of load 154% of load 113% of load SHR: 70% Design Conditions Outdoor design DB: 41.0°F Heat loss: 19685 Btuh Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Manufacturer. Actual airflow: Output capacity: Elec stri p Model: 933 cfm 5.6 kW 98% of load Meets all requirements ofACCA Manual S. Entering coil DB: 68.2°F Temp. rise: 50 °F -F- wrightsoft` 2020-Sep-0914:15A8 M"� Right-Sute@Universal2019 19.020 RSU29066 Page 1 ...amends\WrigFtsoftHVAQTBDWiMTrail, PSLrLp CaIc=MJB Fror4Doorfaces: N i Level `r N urnrtvrnc uccorra. Job #: 1316 Performed by Chris Bateman for: Basile Residence TBD Wind Trail Fort Pierce, FL34981 Air Calcs, LLC 7550 Hidden Hammock Ln Vero Beach, FL 32966 Phone: 772.800.8413 vickilynne@aircaics.com AREATABULATION OGCOPIEDAIC AREA. 1302 SOFT GARAGE 0SOFr FROW FJn RY- MI SOR REAR PORCH: TOTAL FOOTPRIYT . 1493 SOFT SCALE : 114" = T-O" OPTION "A" Scale: 1 : 122 Page 1 Right -Suite® Universal 2019 19.0.20 RSU29066 2020Sep-0914:16:08 oft HVAC\TBD Wind Trail, PSL.rup N Level 1 Kitchen 8 x 8 10 x 10 10 x 10 102 din T 198 dm 198 ch y 7" T T Master Bed 6" ■ T ' 12x12 8 x 8 207 dm 102 drn • 4" Great Room 12" 8x8 8x8 8x4 42 ch 4„ y 8 x 4 5" T 97 ch T 97 Cfm 6cfm •� �•� Master Bath y 911 Wardrob 8„ 6„ 711 Hall Bath 16 " g x 4 � 37 ch T9„ ' Bed 2 Clst 911 1611 4 12x12 7" 160 dm 12x12 20x20 7 " 174 dm 698 dm 51 e- - y 10x6 \12x8 Bed 3 66 dm 12 x 8 160dm 174 dm Utility Job # 1316 Performed by Chris Bateman for. BasileResiderce TBD WinclTrail FctPieroe,FL34981 Air Calcs, LLC MHiddenHarmioci Ln Ve-oBeat FL32966 Phone:772BM8413 vicWVrie@arcalcs.ccm Scale: 1 : 64 Pagel R'KjrtSjb9 Uriversal2019 19.020RSU29065 20D-, e- 14:15:34 -dtHVACVTl3D WrdTral,PSLn.Q