HomeMy WebLinkAboutTRUSS END DETAILSI�
32'
0"
co
LO
ti ti
ti
ti 1`
1^- 1`
ti ti
ti LC)
co
ti
U
U
U
W W
W
W W
W W
W W
W U
U
U
i
CJ 1
.. ;
l
{
CJ3
\"
O
t
t
CJ5..
.-�
O
$
..,;;yam"
, .......
...,
a
\'
O
6
8'-1"
CLNG
5,.r.
O
0
i
O
00
N
4
N
0
`y'
8'-1"
CLNG
N
\\X//
\ \\
`t
C'
�►//
>
3
..
\
0
ITTI
A ESS
3IMMIX,
,:,,,
"
:,..0
CD
j
ATTIC AHU
/'�\ /%`
\
STORAGE
000,
\�
Ki
m7ii...:::�
O
A2
8'-1"
CLNG
\61/2 n
t
1
o
A2
o CJ5
CJ3
0
;t CJ1
0
M LO r r c0 cfl co CO LID
U U ) W W W W 0
W W W W W W
17' 6 1/4" 10' 5 3/4"
32' 0"
CJ1
3
5
00
Oa
CJ5
CJ3 0
0
CJ1
O
N
ro
00
r--I
00
0
Rt
Hatch Legend
8'-1"A.F.F
TRUSS END DETAIL
17
MAIN WIND FORCE RESISTING SYSTEM/C-C HYBRID
WIND ASCE7-10
ENCLOSED
EXPOSURE CATEGORY C
OCCUPANCY CATEGORY II
WIND LOAD 160 MPH
*TRUSSES HAVE BEEN DESIGNED FOR A 10.0 PSF
BOTTOM CHORD LIVE LOAD NONCONCURRENT WITH
ANY OTHER LIVE LOADS
ROOF LOADING FLOOR LOADING
TCLL: 20 PSF TCLL: PSF
TCDL: 07 PSF I TCDL: PSF
BCDL: 10 PSF BCDL: PSF
TOTAL: 37 PSF TOTAL: PSF
DURATION: 1.25 1 DURATION:
BY APPROVED
❑ APPROVED AS CORRECTED
❑ REVISE AND RESUBMfT
❑ FOR YOUR INFORMATION AND USE
❑ INCOMPLETE SUBMITTAL
❑ NOTAPPROVED
Checking is only for conformance with the design
concept of the Project and compliance with the
information given in the Contract Documents.
Contractor is responsipW, J%, dimensions to be
confirmed and ),,aa11ed��.,,,,,pp site; for
information lh�` I Aa3sbFI,. ��Cy.ttabrication
processes or,v hnlgiie 9 ii ei& e; and for
F
IMPORTANT
This Drawing Must Be Approved And
Returned Before Fabrication Will
Begin. For Your Protection Check All
Dimensions And Conditions Prior To
Approval Of Plan.
SIGNATURE BELOW INDICATES ALL
NOTES AND DIMENSIONS HAVE
BEEN ACCEPTED.
By Date
CAUTION!!!
0 NOT ATTEMPT TO EREC'
2USSES WITHOUT REFERRING TC
-lE ENGINEERING DRAWINGS AN[
SCI-B1 SUMMARY SHEETS.
LL PERMANENT BRACING MUST BI
PLACE PRIOR TO LOADING
2USSES. (ie. SHEATHING
HINGLES, ETC.)
LL INTERIOR BEARING WALL!
UST BE IN PLACE PRIOR TC
ISTALLING TRUSSES.
EFER TO FINAL ENGINEERING
HEETS FOR THE FOLLOWING.
NUMBER OF GIRDER PLIES AN[
AILING SCHEDULE.
BEARING BLOCK REQUIREMENTS
SCAB DETAILS (IF REQUIRED)
UPLIFT AND GRAVITY REACTIONS
VVF FXIVIIVV
Backcharges Will Not Be Accepted
Regardless of Fault Without Prior
Notification By Customer Within 48
Hours And Investigation By
Builders FirstSource.
NO EXCEPTIONS.
to General Contractor Is Responsibl
:)r All Connections Other Than Trus:
to Truss, Gable Shear Wall, And
Connections. Temporary and
'ermanent Bracing, And Ceiling And
RES:
VALARDO
MODEL:
KEY LARGO
ADDRESS:
WIND TRAIL
LOT / BLOCK:
--
COUNTY:
ST LUCIE
CITY:
FORT PIERCE
DRAWN BY:
JL
JOB # :
2473009
DATE:
09/26/20
SCALE:
NTS
701 S. KINGS HIGHWAY
FORT PIECE, FL 34946
Ph. (772) - 461 6475