Loading...
HomeMy WebLinkAboutOSTDS NEW.1, i SCANNED STATE OF FLORIDA St Lucie CCU* DEPARTMENT OF HEALTH ONSITE SEWAGE .TREATMENT AND CONSTRUCTION PERMIT • r; CONSTRUCTION PERMIT FOR: APPLICANT:' (One Construction OSTDS New PROPERTY ADDRESS: 7005 Paso Robles Blvd "Fort Pie LOT: 28 BLOCK: 103 PROPERTY ID #: 130161101060006 DISPOSAL SYSTEM FL 34951 PERMIT #:56-SF71494943 APPLICATION #:AP1120273 DATE PAID: FEE PAID: RECEIPT #• DOCUMENT #: PR91716a, Lakewood Park [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER] [OR TAX ID NUMBER] SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION 381.0065, F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE SATISFACTORY PERFORMANCE FOR ANY ,SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS, WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID. ISSUANCEOF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL, STATE, -OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS -PROPERTY. SYSTEM DESIGN AND SPECIFICATIONS T [ A [ N [ 'K [ 900 ] GALLONS / GPD ] GALLONS / GPD ] GALLONS GREASE INTERCEPTOR C ] GALLONS DOSING TANK CAPACITY CAPACITY CAPACITY Y [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS] [ ]GALLONS, @[ ]DOSES PER 24 HRS #Pumps [ ] D [ 500 ] SQUARE FEET Drainfleld R [ ] SQUARE FEET N/A A TYPE SYSTEM: [ ] STANDARD [x] FILLED I CONFIGURATION: [ ] TRENCH [x] BED' N F LOCATION OF BENCHMARK: Nail on south edge of paver I ELEVATION OF PROPOSED SYSTEM SITE 1 12.00. E BOTTOM OF DRAINFIELD TO BE [ 6.00 L D FILL REQUIRED: [12.001 INCHES EXCAM The system is sized for 3 bedrooms with a maximum occupi O of 300 gpd. T The licensed contractor installing the system is responsible H s. 64E-6.013(3)(f), FAC. E R SYSTEM SYSTEM [ ] MOUND [ ] ] ant center of lot [ INCHES FT ] [ INCHES FT ] BELOW] BENCHMARK/REFERENCE POINT BELOW]BENCHMARK/REFERENCE POINT CON REQUIRED: [ ] INCHES .y of 6 persons (2 per bedroom), for a total estimated flow installing the minimum category of tank i nce with SPECIFICATIONS BY: TITLE: `�3'' e R Gatewood Envi o 1 Specialist II APPROVED BY: TITLE: Envirormiental Specialist II St. Lucie CHD Andrew R Gatewood DATE ISSUED: 09/.18/2013 EXPIRATION DATE: 03/18/2015 DR 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC. Page 1 of 3 T,21120273 SE908278 FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 7005 Paso Robles-Mauricio Builder Name: 3437 sw Europe Street: 7005 Paso Robles Permit Office: St Lucie County City, State, Zip: Fort Pierce , FL , 34982- Permit Number: Owner: Jurisdiction: 611000 Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (1312.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.0 1088.00 ftz b. Frame - Wood, Adjacent R=11.0 224.00 ftz 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 3 d. N/A R= ftz 10. Ceiling Types (1230.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1230.00 ftz 6. Conditioned floor area above grade (ftz) 1230 b. N/A R= ftz c. N/A R= ftz Conditioned floor area below grade (ftz) 0 11. Ducts R fF 7. Windows(138.4 sqft.) Description Area a. Sup: Attic, Ret: Garage, AH: Garage 6 300 a. U-Factor: Dbl, U=0.45 138.38 ftz SHGC: SHGC=0.35 � 12. Cooling systems kBtu/hr Efficiency b. U-Factor: N/A a. Central Unit 23.6 SEER:15.00 SHGC: c. U-Factor: N/A ftz SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a. Electric Heat Pump 23.6 HSPF:8.50 i SHGC: Area Weighted Average Overhang Depth: 4.392 ft. Area Weighted Average SHGC: 0.350 14. Hot water systems a. Electric Cap: 40 gallons ' 8. Flopr Types (1230.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1230.00 ftz b. Conservation features b. N/A R= ftz None c. N/A R= fF 15. Credits Pstat 0.113 Total Proposed Modified Loads: 25.60 PASS Glass/Floor Area: Total Standard Reference Loads: 31.87 I hereby certify that the plans and specifications covered by Review of the plans and -VILE Sr4 0. this calculation are in compliance ith the Florida E y specifications covered by this AV = Code. calculation indicates compliance ��u,,,'%' with the Florida Energy Code. PREPARED BY- - Before construction is completed f, - A DATE: this building will be inspected for compliance with Section 553.908 x r, I hereby certify that this building, as designed, is in compliance r Florida Statutes. � 5 GDD with the Florida Energy Code. WL'v ��® �`� OWNER/AGE MT BUILDING OFFICIAL: DATE: t3 DATE: - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 9/18/2013 8:42 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 PROJECT Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: I 7005 Paso Robles-Mauricio Bedrooms: 3 User Conditioned Area: 1230 Total Stories: ' 1 1 Worst Case: I No 3437 sw Europe Rotate Angle: i 0 St Lucie County Cross Ventilation: No 611000 Whole House Fan: No Single-family New (From Plans) Address Type: Street Address Lot # Block/SubDivision: PlatBook: Street: 7005 Paso Robles County: St. Lucie City, State, Zip: Fort Pierce , FL, 34982- CLIMATE Design Location IECC TMY Site Zone Design Temp 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ST_LUCIE_CO_INTL 2 39 90 70 75 722 62 Low 6LOCKS i Number Name Area Volume 1 Block1 1230 9840 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infi11D Finished Cooled Heated 1 Main 1230 9840 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 164 ft 0 1230 W 0 0 1 ROOF / V # Type Roof Materials Area Gable Roof Area Color Solar Absor. SA Emitt Emitt Deck Pitch Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1296 ft2 204 ft2 Medium 0.9 N 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented j 300 1230 ftz N N CEILING # Ceiling Type Space IR-Value Area Framing Frac Truss Type 1 Under Attic (Vented) Main i 30 1230 ft2 0.1 Wood 9/18/2013 8:42 AM EnergyGauge® USA - FlaResi 010 Section 405.4.1 Compliant Software Page 2 of 5 WALLS I Adjacent Cavity Width Height Sheathing Framing Solar Below V a ()Mt p In Wall Type Space ue Ft In Ft In Area 13-Value Frarfinn Ahsnr _ 1 N Exterior Concrete Block - Ext Insul Main 4 26 0 8 0 208.0 ft2 0 0 0.8 0 _ 2 N Garage Frame - Wood Main 1 j1 16 0 8 0 128.0 ft2 0 0 0.8 0 _ 3 E Exterior Concrete Block - Ext Insul Main 4 40 0 8 0 320.0 ft2 0 0 0.8 0 _ 4 S Exterior Concrete Block - Ext Insul Main 4 42 0 8 0 336.0 ft' 0 0 0.8 0 5 W Exterior Concrete Block - Ext Insul Main 4 28 0 8 0 224.0 ft2 0 0 0.8 0 _ 6 W Garage Frame - Wood Main 11 12 0 8 0 96.0 ft2 0 0 0.8 0 DOORS i # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated Main None .29 3 7 21 ft2 2 W Insulated Main None .29 3 7 21 ft2 WINDOWS Orientation shown is ttie entered, Proposed orientation. / Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 n 1 Metal Low-E Double Yes 0.4�5 0.35 4.0 ft2 1 ft 0 in 1 ft 0 in None None 2 n 1 Metal Low-E Double Yes 0.415 0.35 15.9 ft2 1 ft 0 in 1 ft 0 in None None 3 e 3 Metal Low-E Double Yes 0.45 0.35 24.3 ft2 1 ft 0 In 1 ft 0 in None None 4 e 3 Metal Low-E Double Yes 0.45 0.35 15.9 ft2 7 ft 0 in 1 ft 0 in None None 5 s 4 Metal Low-E Double Yes 0.45 0.35 4.0 ft2 1 ft 0 in 1 ft 0 in None None 6 s 4 Metal Low-E Double Yes 0.45 0.35 34.0 ft2 12 ft 0 in 1 ft 0 in None None 7 w 5 Metal Low-E Double Yes 0.45 0.35 24.3 ft2 1 ft 0 in 1 ft 0 in None None • 8 W 5 Metal Low-E Double Yes 0.45 0.35 16.0 ft2 1 ft 0 in 1 ft 0 in None None GARAGE i # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 279.4 ft2 279.4 ft2 34 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess .0005 1613.2 88.56 166.55 .365 9.8363 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF: 8.5 23.6 kBtu/hr 1 sys#1 9/18/2013 8:42 AM EnergyGauge® USA - FlaRei2010 Section 405.4.1 Compliant Software Page 3 of 5 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts - I Central Unit None SEER: 15 23.6 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Main 0.95 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM i FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS I — Supply — — Retum — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 300 ftz Garage 24 ft2 Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans il Coolin [[ jj Heating [X] Jan Feb Jan Feb Mar r Apr Jul Ma X Jun ri Jul May Jun ri Au Aug rl Se Sep Oct Oct Nov Nov Dec Dec Venting [[ ]]Jan Mar Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 9/18/2013 8:42 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 7005 Paso Robles PERMIT #: Fort Pierce, FL, 34982- MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY,OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sqA Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating controls and cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordancie with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level., No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. i Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or Beating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 9/18/2013 8:42 AM EnergyGauge® USA - FlaRes20 i 0 Section 405.4.1 Compliant Software Page 5 of 5 ENERGY PERFORMANCE LEVEL (EPL) DIS ESTIMATED ENERGY The lower the EnergvPerforrr Y CARD RFORMANCE INDEX* = 80 Index, the more efficient the home. 7005 Paso Robles, Fort Pierce, FL, 34982- 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area a. Concrete Block - Ext Insul, Exterior R=4.0 1088.00 ft2 2. Single family or multiple family Single-family b. Frame - Wood, Adjacent R=11.0 224.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. WA R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1230.00 ft2 6. Conditioned floor area (ftz) 1230 b. N/A R= ft2 7. Windows" Description Area c. 11. Ducts R= ft 2 R ft a. U-Factor: Dbl, U=0.45 138.38 ft2 a. Sup: Attic, Ret: Garage, AH: Garage 6 300 SHGC: SHGC=0.35 b. U-Factor: N/A ft2 SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 23.6 SEER:15.00 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: i a. Electric Heat Pump 23.6 HSPF:8.50 Area Weighted Average Overhang Depth: 4.392 ft. Area Weighted Average SHGC: 0.350 8. Floor Types Insulation Area a. Siab-On-Grade Edge Insulation R=0.0 1230.00 ft2 b. N/A R= ft2 c. N/A R= ft2 14. Hot water systems 0?J a. Electric ns 95 b. Conservation features None 15. Credits Pstat I I certify that this home has complied with the Florida Energy Efficiency Code for Building �1.1iE ST Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed;,,`'° based on installed Code compliant features. ��� -; `` �,•' � ���„ �o Builder Signature: uo wcvvk Date: 12 1 13 v > Address of New Home: -5 r p: � �� �� �6�les City/FLZi � � *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. "Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software