Loading...
HomeMy WebLinkAboutFLOOR PLAN2l:.. \ yQt274 '3b7 T Off• _ UP + Z7•G - C'�•(f" j Lp -r 2-7� o " • _ -'i DSO . 1 Lk-i CT•�P) bP.-P9,8 6.1 D: p.,�r✓G 3 Planning & Development Services Department Building & Regulations Division Product Review Affidavit Building Permit # Owners Name Applicant: Product Openina Design Pressures Product Rated Deskin Pressure Manufacturer Model Number Product Approval Number Glass Type Method of Attachment windows hF ¢LEV'S 'tl_ So i�L-lj •SN-'$DO {I - o , I IMpac1 a tm"I'Ig"MIN EM6ED t�GIS &ia" Mullions Fixed Glass nflA Block Glass FFI•A S fights 4 Sliding Glass Doors 'XL° IS1:1tYy +loth • it's r p fir'T 1S~'6 Ib.O'{ MPp� 4�i" K 1'11$"MItJ 6Mf5ED'fG' Q'l y�L•%"D�[� SwOhn Type Doors 6efLF V,6"-t/-(p•} ToiteAk LU r3dz%T AC FL• rJPi NSA '4"xl16AIW kiAeeb'LAPcoN5Q te" 1446e- french Doors �IA ' �i• Cara s Doors +21.o-35.j +3y,7-$1`0 �04tA0,0 1io3. F�$246,3 Nlr` 5/Ie„XI4/9�•A:IA18td66DL4L5 ONFPEI'.B1¢KT Hurricane Protection Roof Veetliation N fA Roofing Material VuK I1ao Valt IA4t zanmNrtF9 CT 20 kill 5444,1 H IA 1'i$" �acFINC, (ilA•1L� (4 t°eR 3�(APy i Planning & Development Services. Department ® - Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982- (772) 462-1553 Certification for Design Load Compliance Project Name: SABA SPEC HOUSE Project Address: 7005 PASO ROBLES BLVD. Permit H: Occupancy Type: R Construction Type: V INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications Involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. • Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code 2010 Edition with 2010 Supplements using ASCE 7-10 ..ry 2. Structure Designed as (check one): X Enclosed -Partially Enclosed _ Open /�.'-11 rrFF�s 3. Risk Category: _I X II_III_IV Exposure Category: X B C_D rV 4. Design Wind Velocity 160 mph 124 ASD N/ALRFD End Zone Width: 5 It tt S. Mean Roof Height: 15 ft Roof Pitch: 4 :12 Parapet: N/A ft is 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on ail plan openings): 16.0 16.0 16.0 27.6 27.6 N/A, Zone 1; Zone 2; Zone 3: Zone 4: Zone 5: Garage: E'•4 0 -25.3 -44.0 -65.1 -30.0 -37.0 N/A \ E•y W 7. Design Loads: Floor: N/A PSF Roof/Dead: 7 PSF Roof/Live: 20 Balcony:, N/A PSF 1 Q- Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A p5f Railings: N/A PLF / CONCENTRATED S. Were Shear Walls Considered For Structure? %Yes -Not Applicable Explain Why Not: �0 V _ 9 i9. Is A Continuous Load Path Provided? %Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? _Yes [[[TTT) 0 DESIGN PROFESSIONAL CERTIFICATION STATEMENT: .� I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie • • County.) also certify that structural elements depicted on these plans provide adequate resistance to the design �P4 forces specified: Cd Paul Welch P.E. 29945 / $115 Print Name Cart # & Co. Cert Auth, Paul Welch Inc, - PLAN 8)29f2013 Signature, Date, and Seal 1984 S.W. Biltmore St. Suite #114 Port St. Lucia, FL Company Name & Address ACCOV Form NU2U-12 Rewsed 311SI12 {}y1 NOTES: 1) THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ECT. SHALL VERIFY ALL DIMENSIONS, CONDITIONS AT JOB SITE, PLANS, SPECIFICATIONS, ECT. 2) STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES. 3) ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SCALED DIMENSIONS. 4) ALL CONSTRUCTION MUST COMPLY WITH THE FBC 2010, AND THE FBC 2010 RESIDENTIAL, 2010 PLUMBING CODE, 2010 MECHANICAL CODE AND THE NEC (NFPA 70) 2008 EDITION. 5) RESIDENCE LOCATED IN NEGLIGIBLE WEATHERING AREA, AND IN VERY HEAVY TERMITE INFESTATION AREA PER FRC 301. _ FILE 0 SCANNED LINTEL SCHEDULE LINTEL LENGTH/TYPE SAFE APPLIES) SAPS APPLIED COMPOSITE NO. GRAVITY GRAVITY M111 UPLIFT BEAM LOAD LOAD LOADw/ LOAD BEAM BLOCK L•1 2'-10" 34" U-LINTELS 6113 -- 4460 - ----- 8F16 011-1T L.2 V-6" 42"13-LINTELS 5163 1 t,41 Q 3547 64 D 8F360B-IT L.3 .4'-0" 48" UdSNTELS 3820 16,4c, 3079 q O 8F16 OB.1T L-4 4'-s" 54"U-LINTELS 6113 2724 SF161B-1T L-5 5'4" 64"U-LINTELS 5365 t 2290 O 8F161B-1T L-6 5'-101, -7011U-LINTELS 4360 2093 BF161B-IT L.7 6'-6" 78".U-LINTELS 3480 - 1880 --=-- 8F161B-1T L-8 7 7'-6" 90"U-LINTELS 2661 - 1634 --- - 8F161B-1T L-9 9'-4" 1IT' U-UNT'ELS 1943 1133 4q SFI6 1B-IT NOTE: WHEN LINTEL IS I VARIOUS LOCATIONS, WORST CASE LOADING IS SHOWN. " 146TE: PROVIDE "C.ASTCRETE' PRECAST CONCRETE LINTEL AS NOTED ON PLANS. TABULATION LIVING 1,230 SQ.FT. GARAGE 280 SQ.FT. FRONT PORCH 84 SQ.FT. BACK PORCH .......... ........................................... 86.sQ..K1, . TOTAL = 1,680 SQ.FT. 1---------------- 54"W X 63"H S.H. WINDOW 2--------------- SH25 WINDOW 3--------------- 24"H X 24"W S.H. WINDOW 4--------------- 8o7o O.H.D. 5--------------- 3o68 SOLID CORE DOOR 6--------------- 5068 SLIDING GLASS DOOR 7--------------- 3068 INTERIOR DOOR 8--------------- 5o6s BI-FOLD DOORS 9--------------- 6068 BI-FOLD DOORS 10------------- 1668 BI-FOLD DOORS St. Lucie County'He2t11 D®pt Envilron"ntal Health D;vlsion lslon site P1An AP p P eviou ^ixR,?lw'foc Supuatl4 0VD-S01 4Tenddell# :1 DDte: ,- PAUINC. r. Reviewe�- MECHANICAL * ELECTRICAL * CIVIL ENGINEERING 1 984 S.W. SILTMORE ST. - # 1 1 4 PORT SAINT LUCIE, FL 34984 PHONE E-MAIL FAX SEP 1 g yp� 1772) 7B5-9BBB PWELCHr11r(d)AQL COM 17721 785-9933 PAUL WELCH, P.E. - FL Rea. No. 29945 SHEET NUMBER 1 OF 3 -JI t 4 I-J L I DP. + z7'.L _ rr. D• O / A �\ �I-II L.11�1-�5 - �TU�PI51DIt�l[�1 . Z 1. el J =t\,; t '32a �B rxp + 2' Planning & Development Services Department Building & Regulations Division Product Review Affidavit Building Permit 0 Owners Name Applicant: Plodud OPeninODesian Pleasures Product Rated Design Pressure Manufacturer Model Number Product Approval Number Glass Type Method of Attachment Windows 5uELEV)6 'tl-so iOCy� :N-ISOC {Ir- o ,l IMPacT''trv"�`I'/p,yMIN'Eµ6Eb t'G'S�6".f�"b,[, Mullions Fixed Glass Block Glass WIA Skyoghts Jrf4 sliding Glans Doors mil;Cud`Vy t10 ib 115 p p%'T r'O-�F°O '1>Z O Ir•.04 MPAN( E�I^K 1'dj$"MI1J Et-1f5EflrG' (?l''�1.Q'x OIL/ swin T eDoora �EEE{ES '{/-(off TNaPJAA'TICU t STAR F`•5 I. NSA %t"x'�4"MIN vtAeED•kfleoN5C1 fa" 14"ar. French Doors 'Garage Doors rt +47.0 -35.7 +35,7 -44a �74UT N 1103. 16tl a246.3 NI> 5/r a'<I`+/Sp 6.iIJ 2Ya BlFD LdLS DNC pW BKKY - hurricane Protection i Q -- Roof Ventilation N rA Roofing Material V"LT Itso Y•I^. la4f c.6erotNrFF9 CT 20 �LI:5444.1 IA )')4" �F'INCS I')6 \L['? Cr. rrR 3'i4ry I have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions. Name: {eul- VJe1.614 ZNe- Design Prof: ?A y6. W rr4C.41 P', E , Cert. No. THIS STRUCTURE HAS BEEN DESIGNED � AND REVIEWED FOR COMPLIANCE OF ST.�LUCIE �COUNTY BUILDING DM9ION FBC 1606.1.4 FOR ONE OF THE FOLLOWING: REVIEWED FO O L v TERMITE TREATMENI REQUIRED INTERNAL WIND PRESSURE REVIEWED BY DATE WINDSORNE DEBRIS PROTECTION PLANS AND FIERIMIT WST BE KEPT ON JOB IMPACT RESISTANCE GLAZING OR NO INSPECTION WILL BE MADE. pt3L Z.x 12 r/ 4xq wv Vog-r waoo v A 0 Ell • I - �'r' -L ' I I I ITlylI s 12 1- 0 N • Oil5 O 2 D 5 D . p„ 4" L-(a � �f G i c Its-E� ( _ _ • ElaP� 5'S . N QetlraE O e(• M TL�I�f'.tX�!-!I VW co 40 IS (�fJP,) , •I. E'(,�f2ESS dl6 eeaAiz --r , Iy 04,ED CELL 0 - - �. 3 L- Z 7 �ln d- Cold- N O rw/G71 Q / I W aIiiiiiiiij ,0 §'l t Planning & Development Services Department e Building & Code Regulations Division 11 2300 Virginia Avenue, Fort Pierce, FL 34982 -(772) 462-1553 Certification for Design Load Compliance Project Name: SABA SPEC HOUSE Project Address: 70DS PASO ROBLES BLVD, Permit#: Occupancy Type: R Construction Type: V INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. • Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for.; questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code 2010 Edition with 2010 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _ Partially Enclosed _Open 3. Risk Category: _I X II III IV Exposure Category: X B C D 4. Design Wind Velocity 160 mph 124 ASO N/A LRFD End Zone Width: 5 ft S. Mean Roof Height: 15 It Roof Pitch: 4 :12 Parapet: N/A It i 6. Components & Cladding Design Pressures Used: (PSF, based on 30sgft Ca115'MRH, clearly label onl�all plan openings): 16.0 16.0 16.0 27.6 27.6 N/A. Zone 1: -25.3 Zone 2: _44.0 Zone 3: -65.1 Zone 4: _30.0 Zone 5: -37.0 Garage: N/A 7. Design Loads: Floor: N/A PSF Roof/Dead: 7 PSF Roof/Live: 20 Balcony: _ N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/APLF / CONCENTRATED S. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? -Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: 1 certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforce by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance so the design forces specified: Paul Welch P.E. 29945 / 5115 Print Name Curt # & Co. Cart AQth. Paul Welch Inc. ON PLAN 8129/2013 Signature, Date, and Seal 1984 S.W. Biltmore St. Suite 4114 Part St. Lucie, FL Company Name & Address SLCCUV Form 4021F12 Revised 3/1l112 O5) NOTES: 1) THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ECT. SHALL VERIFY ALL DIMENSIONS, CONDITIONS AT JOB SITE, PLANS, SPECIFICATIONS, ECT. 2) STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES. '3) ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER _ SCALED DIMENSIONS. �1 4) ALL CONSTRUCTION MUST COMPLY WITH THE FBC 2010, AND THE FBC 2010 RESIDENTIAL, 2010 PLUMBING CODE, 2010 MECHANICAL CODE AND THE NEC (� (NFPA 70) 2008 EDITION. 5) RESIDENCE LOCATED IN NEGLIGIBLE WEATHERING AREA, AND IN VERY HEAVY TERMITE INFESTATION AREA PER FRC 301. THESE PLANS AND ALL PROPOSED WORK i ARE SUBJECT TO ANY CORRECTIONS .> REQUIRED BY FIELD INSPECTORS THAT; k =.MAY BE NECESSARY IN ORDER TO -COMPLYWITH ALL APPLICABLE CODES.' W LINTEL SCHFDULE I.NTEL LENGTH/TYPE SAFE APPLED SAFE APPLIED cohmi NO. GRAVrrY GRAVITY UPLIFT UPLIFT BEAM LOAD LOAD LOADW/ LOAD BEAM .. BLOCK L-I 2'-10" 34"U-1,I11TELS 6113 --- 4460 -- SF16011-IT L-2 3'-6" 42^U-LR4TELS 5163 3547 69D SF160131 L-3 4',0" 48"U.L'AITELS 3820 j 6,4 t, 3079 g,0 8F160B-1T L-4 47-6" 54"U-LINTELS 6113 ---- 2724 -- - 8F161B-IT L-5 5'-4' -64"U-LINTELS 5365 IL 2290 8F16lB-1T L-6 5'-101• 701115-LINTELS 4360 14F 2093 ri 0 SF161B 1T L-7 6'-6" 78"U-LINTELS 3480 - --- 1880 ----- SF16 IB1'C L-8 T-6" 90" U-LINTELS 2661 - 1634 --- - SF16 1B 1 T L-9 9'4' 112" U LINTELS 1843. 6 1133 A SFI6 1B 1'C NOTE: WHEN LINTEL IS I VARIOUS LOCATIONS, WORST CASE LOADING IS SHOWN. � �r • „ -'i40TE: PROVIDE „CA6TORETE^PRECAST CONCRETE LINTEL AS NOTED ON PLANS. O Pa St - i 1 ;r------ �' TABULATION. i, 22ii u d�•(c. 54 V-L"ACI-ESs M LIVING 1,230 SQ.FT. GARAGE 280 SQ.FT. FRONT PORCH 84 SQ.FT. Nz BACK .PORC....H ..... .......... 86.So..FT. ............................. TOTAL = 1,680 SQ.FT. WINDOW/ DOOR SCHEDULE 1----------------- 54"W X 63"H S.H. WINDOW - - - - - - - - l 2--------------- SH25 WINDOW - - - 3--------------- 24"H X 24"W S.H. WINDOW U t,��5 O t 3 I I 4--------------- 80 / 0 O.H.D. 5--------------- 3068 SOLID CORE DOOR 0 i I 6------- -------- 51168 SLIDING GLASS DOOR 7 _______________ 4vuv3o68 INTERIOR DOOR I I 8--------------- 5o6s BI-FOLD DOORS tob 9--------------- 6o68 BI-FOLD DOORS --- I ---- 10------------- 1668 BI-FOLD DOORS VOL. 2.r12 woof AL1 L-9 F� N d 2 x F W 2 a� aI O O G PAUL WELCH INC. SHEET NUMBER MECHANICAL * ELECTRICAL * CIVIL ENGINEERING 1 964 S.W. BILTMORE ST. - # 1 1 4 PORT SAINT LUCIE, FL 34984 PHONE E-MAIL FAX Y 17721 785-9868 FsWELCHU GAOL COM 17721 785-9933 %.. PAUL WELCH, P.E. - FL Rao. NO. 29945 SEP 19 2013 1X P.T. BUCK ALTERNATE BUCK 2"XS" OR 2"XB" P.T. W/ 3/16" TO'S W/ 1 K" MIN. EiviBD. @ 4"/12" O.C. W/,510 SCREWS PER P%A .,\. PROVIDE 1 YV CASEHARD NAILS @ 4" FROM ENDS AND S" O.C. W/ TC'S PER PRODUCT APPROVAL NOTE;USE 1"X6" P.T. BUCK @ SGD'S NOTE: TC' TO BE INSTALLED THRU BUCK INTO MASONRY WITH MINIMUM 1 3/8" EMBEDMENT PER PRODUCT APPROVAL PER FBC 1715.5.4.3 BUCKS MUST COVER ENTIRE DEPTH OF JAMB. DOOR BUCK DETAIL N.TS. ALTERNATE BUCK 2'X6" OR i" 10 P.T. W/ 3/16" TC'S W/ 1 'A"NLN. EMBO. M 4"/12'0.0 W)NLO SCREWS PER P/A I z P.T. WINDOW 0 UCK PROVIDE 1 W C.ASEHARD NAILS @ 4' FROM ENDS ANDS" O.C. W( TC5 PER PRODUCT APPROVAL STUCCO FINISH RETURNEDTO WINDOW FRAME ON EXTERIOR NOTE: TU TO BE INSTALLED THR11 BUCK INTO MASONRY WITH MINIMUM 1 3/8" EMBEDMENT PER PRODUCT APPROVAL PER FBC 1715.5.4.3 BUCKS MUST COVER ENTIRE DEPTH OF JAMB. WINDOW BUCK DETAIL N.T.S. P PLATE OR 1 %2"X3 5/8" JNNER )OD FRAMING @ 16" O.C. 3 518" METAL STUDS 'ALL BOTH SIDES TT. PLATE OR 1 %2"X3 5/8' JNNER W/TAPCONSOR .S @ T-O" O.C. (10a NAILS )D FLOOR) FLOOR T,�+•s 1 TYPICAL INTERIOR NON -BEARING WALL DETAIL N.T.S. FIBERGLASS R-,J,o NSULATION IX2" DRYWALL (WALLS AND CLG)� 8"X8"X 16" CONTINUOUS CONIC BEAM BLOCKW/ (1) - #5 BAR IN'-1 (3000 PSI) CONIC. FILLED CELL 8" PRECAS LINTEL W/ (I)-#5 BAR _/ IN (3000 PSI) CONC. FILLED CELL AT ALL DOOR AND WINDOW OPENINGS (SEE LINTEL SCH, FOR MORE INFORMATION) ,ELL. b*LL EW(P'CY't,Tn+-�-., WI SOA4M 1:Ve+u6A.Tjo►1 (.V-1,3) . Iv 2 FuwrIM6o G 24"0,c,'---- WOOD OR VINYL, BASE FLOORING BY CONTRACTOR At" ' BLOCKW NOTE iNTER(OIZCBS WALLSIMILAK. 3 TAB SHINGLES OVER T@# ROOFING FELT ON IM2" CDX PLYWOOD ROOF SHEATHING NAILED W/ 8d RINGSHANK NAILS PER DETAIL PRE- ENGINEERED WOOL) TRUSSES @ 24" O.C. (MAX. SPACT14C FIRRING "SIMPSON" STRAP PER TRUSS �— CONNECTORSCH. METAL FLASHING (DRIP EDGE) 2X6 P.T. WD. FASCIA ('OPTIONAL 2 x 6 CEDAR FASCIA) t VENTED SOFFIT PER SOFFIT DETAIL #5 REBAR W/ 90 DEGREE HOOK 8"X8"X16" CONC. BLOCK (MASONRY) 9'-4" WALL HT. VERIFY #5 VERT. REBAR IN (3000 PSI) CONIC. FILLED CELL - (SEE FLOOR PLAN FOR LOCATIONS) STUCCO FINISH 5/8" THICK #5 REBAR W/ 30" MIN, LAP SPLICE (2500 PSI) CONC. FOUNDATION �— SEE PLAN FOR SIZES AND SPECIFICATIONS 4" FINISHED GRADE n1s... I ' 6" v 4- . 2" X 6" OR 2" X 8" P.T. WD BUCR W/ 3/16" X 2'/a" TAPCONS @ 12" O.C. ' 2" X 8" P.T WD BUCK (TYP) 6„ 6 BUCK W/ %2" X 5 %2" REDHEADS, Wf SON. 2" 0 X 1/8" WASHERS GARAGE DOOR BUCK DETAIL nu... — O � •I I I I �- 1 —= x 4 f7&6r Pr-IZ y�b>51AIL 7a7 GACt1 r ROOF SHEATIJ114G NAIL NG ZONE L NAILS @ 6" O.C. PER & 6" Q.C. FIELD 2. NAILS @ 6" O.C. PER & 6" O.C. FIELD 3. NAILS @ 4" O.C. PER & 6" O.C. FIELD NOTE: USE 6O RING SHANK NAILS FOR ROOF SHEATHING ATTACHMENT PER FRC-E103.2.3,1 ia° x 3" LkG o6T TYPE DESIGNATIUN I I 'Q1L2X 2. wt? PIcX$-:TS F = FILLED WITH GROUT / II - UNFILLED / 5 = SOLI[ �-" D. C' F F QUANTITY OF 15 FIELD ADDED REBAR AI —ZX(o goTiD Nl CpFS €vV/ 4Nj— BOTTOM OF LINTEL CAVITY YA°,X 3"LAGAL11I YD�# 5F: 7 6-1 B/1 T V NOMINAL WIDTH `QUANTITY OF 15 FIELD NOMINAL HEIGHT --J 'n a ADDED REBAR AT TOP IS FIELD ADDED REBAR AT TOP MIN. (1) RFO'O I-1/2' CLEAR FIELD PLACED C.M.U. m i GROUT N e /5 FIELD ADDED REBAR AT • • BOTTOM OF LRITEL CAVITY BOTTOM REINFORCING 7-5/8' ACTUAL PROVIDED IN LINTEL 8- NOMINAL WIDTH (SEE REINFORCING SCHEDULE) iTUCCO OVER WIRELATH W/ I IGA. 2" JAILS W/ 3/8" 0 HEAD @ 6" 0C, OVER 1/8" METAL RIB LATH @ 6" O.0 W/ (2 LAYERS) OF 15# FELT OVER WD 7 AMTNG MEMBERS (TRUSS TAILS). IROVIDE 6"X 18" SOFFIT VENTS @ 48" O.C. STUCCO SOFFIT DETAIL nts... 3 TAB SHINGLES OVER 30 9 FELT ON 19/32" COX PLYWOOD SfMATH1NG NAILED W/ 8d RINGSHANK NAILS PER ROOF SI-MATFITNG NAILING ZONE DETAIL PRE-ENGINEERED ROOF TRUSSES @ 24" O.C. MAX SIMPSON STRAP PER TRUSS �CONNECTORSCH. 1 �\ ALUM. DRIP EDGE -f r l X6 P.T. WD. FASCIA z M�h`y 2X4 WD. SUB -FASCIA %SZE���SQ�p 114 STUCCSTUCCO CEILING: CC WIRELAO OVE H W/RIIGA. 2" CQNG�� 1HEPSSpORS�QFP �(i� NAILS W/ 3/8" 0 HEAD @ 6" O.C. OVER 3/8" METAL SON RIB LATH @ 6" O.C. W/ (2 LAYERSOF 15# FELT OVER EACH FRAMING MEMBER). TYe[CAL,04 POSI RETAILLLLB VENTED SOFFIT PER DETAIL DOUBLE 2X12 WOOD HEADER WITH'72" CDX PLYWOOD SPACER GLUED AND NAILED W/ 16d NAILS AT 8" O.C. STAGGERED BOTH SIDES SIMPSON AC4 W/ (28)-IQNAILS EACH POST TO HEADER (USE SIMPSON LCE4 @ CORNER POSTS WITH (24)-16d NAILS) SIMPSON LSTA 18 W/ (14)• 10d NAILS AT CORNER POSTS (1) PER HEADER P.T. 4X4 WOOD POST SIMPSON ABU44 WITH (12)-16d AND (I)- 5T8"m X 8- ANCHOR BOLT FBSSSHED GRADE (5SDI MP LO NP. FOUNDATION (FE.ASG(SSSflATIONPLAN) . CALCULATE ATTIC VENTILATION STRUCTURAL NOTES 1) DESIGN LOADS IN ACCORDANCE WITH ASCE7-10. 2) SOIL BEARING CAPACITY: 2500 PSF (MIN.). 3) ALL STRUCTURAL CONCRETE IN BEAMS, LINTELS, VERTICLE CELLS, AND COLUMNS SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI COMPRESSIVE STRENGTH AT 28 DAYS. 4) SLAB / FOOTINGS TO BE CONCRETE WITH A MINIMUM 2500 PSI COMPRESSIVE STRENGTH AT 28 DAYS. SEE PLAN FOR SIZES & STEEL REQUIREMENTS. 5) MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: FOOTINGS: 3" BEAMS: 1 %2" SUSPENDED SLABS: 1'/21' 6) LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS EXCEPT AS NOTED GRADE 60 STEEL MINIMUM IN BEAMS AND COLUMNS. 7) ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. 8) SPLITING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO INSTALATION OF HARDWARE IS NOT PERMITED. 9) UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE SHALL CONFORM TO THE MANUFACTURES INSTRUCTIONS AND STANDARD PRACTICIES. 10) UNLESS OTHERWISE NOTED, ROOF SHEATHING TO BE NAILED WITH 8d RING SHANK NAILS AT 4" O.C. PERIMETER AND 6" O.C. FIELD. 11) UNLESS OTHERWISE NOTED INTERIOR DRYWALL IS TO BE NAILED WITH 10d OR BETTER NAILS 6" O.C. EDGES, AND 6" O.C. FIELD, OR SCREWED WITH DRYWALL SCREWS 1.5" LONG AND 0.131 DIA. 12) LINTELS SHALL HAVE A MINIMUM 4" BEARING EXCEPT RECESSED LINTELS SHALL HAVE 8" BEARING. 13) PROVIDE # 5 CORNER BARS W/ 30" MIN. LAP SPLICE FOR BOND BEAM. 14) STUCCO SOFFIT NOTE: SOFFIT TO BE STUCCO OVER WHIELATH W/ I1GA. 2" NAILS W/ 3/8" O HEAD @ 6" O.C. OVER 3/8" METAL RIB LATH @ 6" O.C. W/ (2 LAYERSOF 15# FELT OVER EACH FRAMING MEMBER). 15) PROVIDE R-11 BATTS. INSULATION IN WALL FRAMING. CEILING = 1680 SQ. FT. 1680 1150 = 11.2 REQUIRED VENTILATION 14 L.F. OF 611 X 18 " VENTS L 48 " OC. = 30.75 SF / 2 = 15.4 SF AVAILABLE FOR CROSS VENTILATION 15.4 SQ. FT. > I SQ. FT, VENTILATION O.K. PROVIDE 6" X 18" SOFFIT VENTS CIa 48" O.C. D I 1--Tf--T I 11 I 1 KIL51 i - IL--{ ADDITIONAL NOTES 1) ALL INTERIOR GYPSUM BOARD TO BE MIN.12Y2" THICK WITH (13 GAGE, 1 3/8" LONG, 1.9/64" HEAD; 0.098" DIAMETER, 1 Y" LONG, ANNULAR -RINGED; 5D COOLER NAIL, 0.086" DIAMETER, 15/8" LONG, 15/64" HEAD; OR GYPSUM BOARI NAIL, 0.086" DIAMETER, 1 5/8" LONG, 9/32" HEAD) SPACED AT 7" O.C. FOR NAILS AND 12"' O.C. FOR SCREWS. (PER FRC 702.3.5) 2) WALLS AT SHOWER TO BE TILE. PROVIDE CEMENT, FIBER -CEMENT OR GLASS MAT GYPSUM BACKERS IN COMPLIANCE WITH ASTM C 1288, C 1325, C 1178, OR C 1278 AND INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS AS BACKERS FOR WALL TILE IN TUB AND SHOWER AREAS .AND WALL PANELS IN SHOWER AREAS. (PER FRC 702.4.1 & LTRC 702.4,2). 3) WALL AND CEILING FINISHES SHALL HAVE A SMOKE -DEVELOPED INDEX OF NOT GREATER THAN 450. 4) WALL AND CEILING FINISHES SHALL HAVE A FLAME -SPREAD CLASSIFICATION OF NOT GREATER THAN 200. 5) ALL EXPOSED INSULATION MATERIALS INSTALLED ON ATTIC FLOORS SHALL HAVE A CRITICAL RADIANT FLUX NOT LESS THAN 0.12 WATT PER SQUARE CENTIMETER. EXPOSED FOAM PLASTIC INSULATION MATERIALS EXPOSED TO THE UNDERSIDE OF THE ROOF DECK OR ON THE ATTIC WALLS SHALL COMPLY WITH SECTION FRC316. 6) PER FRC 702.2.1 ALL GYPSUM BOARD MATERIALS AND ACCESSORIES SHALL CONFORM TO ASTM C 36, C 79, C 475, C 514, C 630, C 931, C 960, C 1002, C 1047, C 1177, C L178, C 1278, C 1395, C 1396 OR C 1658 AND SHALL BE INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF FRC, AND ADHESIVES FOR THE INSTALLATION OF GYPSUM BOARD SHALL CONFORM TO ASTM C 557 7) INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR RETARDERS OR VAPOR PERMEABLE MEMBRANES IN WITHIN FLOOR CEILING ASSEMBLIES, ROOF -CEILING ASSEMBLIES, WALL ASSEMBLIES, CRAWL SPACES AND ATTICS SHALL HAVE A FLAME SPREAD INDEX NOT TO EXCEED 25 WITH AN ACCOMPANYING SMOKE -DEVELOPED INDEX NOT TO EXCEED 450 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. GARAGES FLOOR SURFACE 1) GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL. 2) THE AREA OF FLOOR USED FOR PARKING OF AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE MAIN VEHICLE ENTRY DOORWAY. 2 "dTR PLUMBING NOTES: 1) ALL WORK SHALL BE IN ACCORDANCE WITH THE; FBC 2010-PLUMBING 2) DW V PIPING SHALL BE SCHEDULE 40 PVC. 3) WATER PIPING IN BUILDING SHALL BE ONE OF THE FOLLOWING: TYPE L COPPER, CPVC, OR PEX. 4) SLEEVE ALL PIPING IN CONTACT WITH CONCRETE OR UNDERGROUND WITHIN BLDG. THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT i ..MAY BE NECESSARY IN ORDER TO 1 COMPLY WITH ALL APPLICA%E CODES.`. FOUNDATION SCHEDULE F-1 1 (o "D X 12"W (2500 PSI) CONC. MONOLITHIC FOOTING W/ (2) #5 BARS CONTINUOUS F-2 1211 X 12" (2500 PSI) CONC. MONOLITHIC FOOTING W/ (2) #5 BAR CONTINUOUS S-1 4" THK (2500 PSI) CONCRETE SLAB W/ FIBERMESH OR 6"/6' 10/10 WWM OVER VAPOR BARRIER ON CLEAN COMPACTED CHEMICALLY TREATED SOIL PAUL WELCH INC. MECHANICAL * ELECTRICAL * CIVIL ENGINEERING 1954 S.W. BILTMORE ST. - ill 1 4 PORT SAINT LLIME, FL 34964 v PHONE E-MAIL �� FAX E (772) 785-9666 PWLGHLtLo(a)hOL COM (772) 785-9933 SEP 19 2013 PAUL WELCH, P.E. — FL REG. NO. 29945 SHEET NUMBER .00 2 E 3 The new MBHU bean) hanger provides a lace-Ahmaled BDlhalf tea connecting beams to masonry or concrete walls. A momwMoed, One plebe ahnneCOK the MBHU is suitable bar solid sawn and engineered wood beams as wall as trusses. installation Is simplified because the Than HOW Bemw anchn, and SKOOG Daivew SDS screws are Included wifit the hanger. Since the THAT He anchor Is installed attar the wall Is built, localing the anchor in the rig, l spot is aside, than wilh cast in -place bolls. MATERIAL: 16 gauge FINISH: Galvanised INSTALLATION: • Use all specified ladtenerd QnClude U.. Amlh hadWar as a mllemte a, grouted CMU wall name RanHO Sodium. Note the loilaeing: SIR nobs using din bad equal In diameter to the specified Then HD ancha,. Holes shall be edlled d- deeper Ulan We Biennial Then HO length 4e Si5'to, A 5•Img To. HD annmr) - Caulior Ovalsoad holes in lad base material will reduce of Shminale the mechanical Interlock of ma threads with the base material and will d ace the smchoh load capacity. • Titan HO is not recommended lot Wosed Senator applications. • Pmvide moisture bahier between heart and will( par jilmedieticnll requirements. SOS CUBES: See page 20 lot Code Reference Key Chant fr I IN 1�Illllrl Ma441 N@ P m 8 88 Ia M WWIn (hill nIHIM Ire l MBHII9511925KT in, 954 ....a6 ..2 ... 3N fin MSHU356111 BBKT aPO iv._ M@HU35W19KT . BSa 14 S IW956116KT 3Sa 96 MSHUS5aIS 25KT SW 94. MBHUSEWIIMKT 515 d MBHUS.BWiIBBKT 5w 1I -MBHU SNflKT '5Sj 14 ' BIW640f10KTI 5w 14 '-. HU shift 2. - R4 ail '. SIMPSON SIeTOPATjS H 1� B > MBHU Typical MBHU holallallm "x25i` Tiles NO•r:"r5"acraw anchor Allow'INLPadP .Allowable Load. Poslmer (handed EudeIWB11PIt gm0,SHOPBSubsCMI Awaylf;q Ede 4{ F)T CIBU Pophre CMuxpq..p¢ No .Mad9i .:. pp le 9Wn UPfill- DAWhing UAllll g0WBIPP Upllll AoN4lgydonn. flq} — P6P1' loor IIBO) 11011 I1601 11BI1P41 loan Be'..'5 lifil1R51 1}4%!$41 ,.iAe 9Y3 to 19 112U 2440 2T5 419g 210 4005 MBHU350 la 3yh 9& 2 e: x5' IR 2H'-" W55 14d IB 1720 2940 2715 4190 3345 F24 @Ye WAA P20 2g90 ?,p15 'A190 2214 ' 4005,* MBHU 50 ID 5N Bid 2 W'x5' _ Idla1B 12 H 2H' — 2175 0$fi0 3400 447q I,?45 4455 1. UPI It bads nave been increased lot with 0amman" laedllw with no lwthed roman..hawed: ,educe white chair loads poPam. 1. Minimum emu compressive saennh Cle added. ISao Ps and mnnwea nW d ive tln.ph li stall be 2600 to 0. fi11YLIY'a Wmpasf, Immel (dialscan adva. etmum spenila ALI Mof A.S. 4. Albwanu loed5 a01Y co, I, he Ital an an B'nomiw p,auled CMU wMN with lrrmumou Wttable,15 rear resoled nIna IdI Lomsa. L Each MENU Nn ar inLludas 5, Pmduns Shall be installed sucnlNl lnai'len nD' anal alsare oat expose0la the waalne,. g 6. Mlawmle table alebased epos the waled ullimade I.e. Wilh asdle11 heeds o12. IRI4.'x@'iron Ho' O.SaMd HRI V x2H 61mne'Odve• SDS scrwe. aW - a... W wmwWlS utw NW lwmvma5nm Mlmawedea "w SawasM puuu NW"weso aawrtL MW'nW run. 1Aad0attm at Oateide Cwau (Mo.. Load) I of aw mn fo twl End of Wall 1� Iwndnw it n toaal lint Installation Away ham Edge of Wall (Maximum Lad) TRUSS CONNECTOR SCHEDULE TRUSS ID BEARING POINT TRUSS ACTUAL CONNECTOR CONNECTOR FASTENERS NOTES UPLIFT ID UPLIFT DESIGN GRA EACH 987 (1) HETA 20 1810 (9)-10d X 11/2" GRB 1ST & 3RD 1021 (1) HETA 20 1810 (9)-10d X 11/2" GRB 2ND 2424 (1) DETAL20 2480 (18) -10d X 11/2" 1 ALL OTHERS LESS THAN 1000# EACH < 1000# (1) HETA 20 1810 (9)-1ed X 11/2" AT CBS BEARING TRUSS COMPANY CHAMBERS LAYOUT DATE 8 30 2013 CUT -SHEET DATE 9 3 2013 * NOTE: USE SIMPSON EPDXY STRONG TIE SYSTEM WITH 12" MIN. EMBEDMENT. NOTE: ALL STRAPPING TO BE SIMPSON STRONG -TIE AS SPECIFIED, 1 (3) HTSM16 WITH (8)-1ed AND (4)- 1/4" X 2 1/4' TITEN EACH MAY BE USED IN LIEU OF DETAL20 AS SPECIFIED TRUSS NOTES: 1) ALL ROOF TRUSSES TO BE DESIGNED BY TRUSS COMPANY'S ENGINEER. 2) CONTRACTOR TO PROVIDE PAUL WELCH INC., AND BUILDING DEPARTMENT WITH ENGINEERED TRUSS DRAWINGS BEFORE INSTALLING TRUSSES. 3) CONTRACTOR TO VERIFY ALL EXISTING ROOF CONDITIONS, AND DIMENSIONS BEFORE ORDERING, AND INSTALLING TRUSSES. 4) TRUSSTOTRUSS CONNECTIONS TO BE PROVIDED BYTRUSS COMPANY. 5) SEE TRUSS CONNECTOR SCH. FOR TRUSS TO WALL CONNECTIONS. T IaI U 1 I I AT ✓ TRUSS LAYOUT - p'�pCNM OpNT� 3 # 3/0 THW IN 2" C ELECT. SERVICE 200 2 MBR 1 3 # 3/0, #4, 2" C t4 CU GRND TIED TO BLDG STEEL, CWP AND DRIVEN GRND ROD "EP" 120 / 240V I� 200A MLO i NOTE: USE ALL COPPER WIRE. ELECTRICAL RISER/DIST. nts,.. O PTIO N "A" 3 # 3/0 THW IN 2" C UNDER GROUND ELECT. SERVICE 0` M I 200 �� I 2 MBR 3 # 3/0, 44, 2" C j, #4 CU GRND TIED TO BLDG STEEL, CWP AND DRIVEN GRND ROD 120/ 240V 200A MLO ITT. NOTE: USE ALL COPPER WIRE. ELECTRICAL RISER / DIST, nts.. OPTION "B„ b1 i HESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT . MAY BE NECESSARY IN ORDER To. . COMPLY WITH ALL APPLICABLE CODES, FILE Opy ELECTRICAL NOTES 1) SMOKE DETECTORS TO BE I I OV W/ BATTERY BACK UP -ARC FAULT CIRCUIT 2) SMOKE DETECTORS TO BE LOCATED AS SHOWN. 3) SMOKE DETECTORS TO BE INTERCONNECTED SO THAT ONE SMOKE DETECTOR ACTIVATES ALL SMOKE DETECTORS IN THE RESIDENCE 4) PROVIDE BRANCH CIRCUIT ARC -FAULT PROTECTION FOR ALL CIRCUITS SERVING: FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS PER FBC AND NEC REQUIREMENTS. 5) PROVIDE GROUND -FAULT CIRCUIT INTERRUPTER PROTECTION FOR ALL 125-VOLT, SINGLE-PHASE 15 AND 20 AMP CIRCUITS SREVING: BATHROOMS, GARAGES, KITCHENS, ACCESORY BUILDINGS, OUTDOORS, OR WITHIN 72" OF EDGE OF ANY SINK. 6) CARBON MENOXIDE DETECTORS TO BE INSTALLED WITHIN 10' OF ALI, BEDROOMS. 7) EXHAUST FANS TO BE VENTED THRU ROOF OR SOFFIT. 8) PROVIDE TAMPER RESISTANT RECPTICLES PER NEC REQUIREMENTS. ELECTRICAL LOAD CALC'S PER NEC 1230 S.F. @ 3 VA TWO 20A APPLIANCE CKTS LAUNDRY DRYER RANGE WH DW WP TUB (OPTION) REFRIG IRR. PUMP (OPTION) MISC TOTAL FIRST 10 KW @ 100% REMAINDER n)..40% TOTAL A/C HEAT 0 100% TOTAL 34036 240 - 141.8167 AMPS USE 200 AMP SERVICE 3690 VA 3000 1500 5000 12000 4500 1200 1200 1200 18UO 5000 40090 VA 10000 12036 22036 12000 34036 VA ELECTRICAL KEY SINGLE POLE SWITCH `J��� THREE WAY SWITCH UI) DUPLEX CONVENIENCE OUTLET 120V SPECIAL PURPOSE OUTLET 220V OUTLET ❑ FAN BOX/LIGHT E EXHAUST FAN/LT. GOM60 61F1 GROUND FAULT PROTECTION &W--6 WEATHER PROOF O SMOKE DETECTOR CO CARBON MONOXIDE DETECTOR EQUIPMENT DISCONNECT LIGHT FIXTURE PAHL WELCH INC. MECHANICAL * ELECTRICAL * CIVIL ENGINEERING 1954 S.W. BILTMORE ST. - #1 14 PORT SAINT LUCIE, FL 34964 PHONE E-MAIL FAX SEP 1 9 2013 19721 '75 BBBLCH,EP E. �rFL CT7 REo a' 299145 5-9933 N4 wo U W F'eI a N . A d h N a � ao a T� V1 U M h+�al Z O O O V1 a kn O O l` SHEET NUMBER 3 a1-