HomeMy WebLinkAboutLETTER-ROOFING SPECIFICATIONSArch itecton ic Inc FILE COPT
March 12, 2018 RECEIVED
SCANNED MAR 14 2010
BY:
Saint Lucie County Building DepaMATIP Chunty Permitting Department
St. Lucie County
Attn: Roof Permit Plan Review
2300 Virginia Avenue
Ft. Pierce, FL 34982
Re: Roofing specification preps led for the St. Lucie County Building Dept. for the structure .
located at, 147 Pepper Lane, Saint Lucie County, Florida
Manufacturer:
Profiles:
Code:
Wind Speed:
Exposure:
Mean Roof Height:
Pitch:
Required Design Pressure:
Maximum Uplift Pressure:
Fasteners:
Boral Roofing, LLC.
Boral Villa 900 Concrete Roof Tile, FL# 7849-R11
FBC 2017; Section R 905
165 MPH; Ultimate Design Wind Speeds
C
30' Maximum
5/12 Minimum
Zone1: 132.81 Zone 2: -54.69 Zone3: -82.93
-133.7 I
2 #8 Screws and ICP Adhesives Polyset AH-160 two -component Foam
Large Paddy placement of a minimum of 54 Grams (Zone 1 & 2 Foam
Adhesi v� e Only, Zone 3 Screws & Foam Adhesive)
Underlayment: Polyglalss Roof Underlayments, FL# 5259-1327 (self -adhering)
Roof Decking: Existing 5/8" plywood sheathing to be nailed w/8d x 2" ring shank
@ 6" O.C. thru out zone 1, 4" O.C. perimeter, and 6" O.C. field zone 2,
and 41 O.C. thru out zone 3.
The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code,
and the Manufacturer's recommendations.
806 Delaware Avenue Tel: ; 772 460 7751 www.architectonicinc.com
Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1