Loading...
HomeMy WebLinkAboutLETTER-ROOFING SPECIFICATIONSArch itecto­n ic Inc FILE COPT March 12, 2018 RECEIVED SCANNED MAR 14 2010 BY: Saint Lucie County Building DepaMATIP Chunty Permitting Department St. Lucie County Attn: Roof Permit Plan Review 2300 Virginia Avenue Ft. Pierce, FL 34982 Re: Roofing specification preps led for the St. Lucie County Building Dept. for the structure . located at, 147 Pepper Lane, Saint Lucie County, Florida Manufacturer: Profiles: Code: Wind Speed: Exposure: Mean Roof Height: Pitch: Required Design Pressure: Maximum Uplift Pressure: Fasteners: Boral Roofing, LLC. Boral Villa 900 Concrete Roof Tile, FL# 7849-R11 FBC 2017; Section R 905 165 MPH; Ultimate Design Wind Speeds C 30' Maximum 5/12 Minimum Zone1: 132.81 Zone 2: -54.69 Zone3: -82.93 -133.7 I 2 #8 Screws and ICP Adhesives Polyset AH-160 two -component Foam Large Paddy placement of a minimum of 54 Grams (Zone 1 & 2 Foam Adhesi v� e Only, Zone 3 Screws & Foam Adhesive) Underlayment: Polyglalss Roof Underlayments, FL# 5259-1327 (self -adhering) Roof Decking: Existing 5/8" plywood sheathing to be nailed w/8d x 2" ring shank @ 6" O.C. thru out zone 1, 4" O.C. perimeter, and 6" O.C. field zone 2, and 41 O.C. thru out zone 3. The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code, and the Manufacturer's recommendations. 806 Delaware Avenue Tel: ; 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1