Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING TILES1r z f�fT`� ri" �2`�t�� �����.y.�i�s r{5�;�,r��if�:��$ �4 � f r/ t�' � ��..f� r•Y°�f iiJrr _ aSnaspa: �ir5�.? � �"5+.'iJ..tiiwar:.,.>"< :aa•?,- r, `.i.,S�`w,�tt; +✓: y�$.� , i >a��,.t.m.-!3� rt r?.3 , fr..i k. fir;{a. ..__ .. > 1 BCIS Home i Log In i User Registration Hot Topis i Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links SearchProdu3 b a - a )USER: Public C TF, �i1.LT n� '. �. ?l SION ST. U C oUivTY _ REVIEWED FOR COAL dC Product Approval Menu > Application Detail Ri VIEWED BY DATE 3 y 5(w 4 Wi FL # FLvision it NS AND PERMIT MUS BE INEPT ON JOB Application Type r Revision PI''�-T T Code Version � 2017 OR NO LgSPEE ON WILL BE XADEt Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission If necessary. Comments Archived I THESE PLANS AND ALL PROPOSED WORK Product Manufacturer Boral Roofing / MonierLifetile ARE SUBJECT TO ANY CORRECTIONS Address/Phone/Email 7575 Irvine Center Drive Suite REQUIRED BY FIELD INSPECTORS THAT Irvine,, CCA 92618 (602) 269-2288 Ext 8320 MAY BE NECESSARY IN ORDER TO thomas.jemmett@boral.com COMPLY WITH AID APPWOAAW 0001I8e Authorized Signature Thomas ]emmett thomas.jemmett@boral.com 1 Technical Representative Adrian Cooper Address/Phone/Email 1369 Hammondville Road Pompano Beach, FL 33069 (954)786-5360 adrian.cooper@boral.com Quality Assurance Representative Address/Phone/Email Category r Subcategory i Compliance Method Evaluation Entity Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Thomas B. ]emmett 7575 Irvine Center Drive Irvine, CA 92618 (602)515-6933 BoralRoofingUSAQuality@boral.com Roofing Roofing Tiles ONCFALED FASTENERS OR ATTACHMENK'� ARE THE RESPONSIBILP OF THE CONTRACTOR OF RECORD Evaluation Report from a Product Evaluation Entity IAPMO Uniform Evaluation Services LLC. 10/04/2018 Gary W. Walker L-2JI Validation Checklist - Hardcopy Received FL7849 R11 COI IAPMO UES Statement of Independence odf FL7849 R11 COI RICgawa Associates - Statement of Indeoendence.pdf Referenced Standard and Year (of Standard) Standard ASTM C1492 Equivalence of Product Standards Certified By Sections from the Code Year 2003 Design Pressure: N/A Other: Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Go to Page = a Evaluation Reports FL7849 1111 AE IAPMO UES ER 412.pdf rL/O•fy K11 11 rKJr1 1 Rl'111SLOIIOII uu Verified By, Gary W. Walker 40455 Created by Independent Third Party: Yes Evaluation Reports FL7849 Rli AE IAPMO UES ER 412.13df 0 it Page 2/ 2 0 m Back Next Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please / click here . Product Approval Accepts: 011 ® F;CEct M Credit Card No nsecuriv,O.IrTit 5th EDITION REVI'SEC If utilizing staples then the battens shall be attached at 12" on center with staples 7/ 16" crown, No.16 gauge corrosion resistant allowing for 3/4" penetration into roof deck or through the sheathing whichever is less. Staples cannot be used with adhesive set systems. Leave 1/2" space between batten ends and between batten and metal edge returns. Fasteners shall be compatible with batten material. Note: Elevated or counter batten systems require FBC product approval. Contact the roof tile manufacturer for product approval and installation instructions. Tile Installation - Stack tile to facilitate installation and min- irnize tile movement. See Drawing FHW-19. At the eave clo- sure all fastener penetrations shall be sealed and installed to avoid restricting water flow. Choose one of the following eave closures. • Metal Eave Closure - Install closure strip along eave. Fasten minimum 18" on center. If metal closure is inclu- sive of the drip edge, fasten 6" on center. See Drawing FHW 11. • Prefabricated Rubber Eave Closure - Install closure strip along eave. Fasten with minimum three fasteners per 36" strip. See Drawing FHW-1 1. • Raised Fascia/Wood Starter Strip - See Drawing FHW-1 I. • Prefabricated concrete or clay eave closure - Apply per manufacturer's instructions. • Mortar - Install mortar to elevate eave tile on Granular Surfaced underlayment's only. Apply mortar along the eave edge, applying enough mortar to elevate the eave end of the the to be on plane with the remaining roof tile. Point and smooth finish flush to eave line. A mini- murn 3/8" weep hole flush with the roof underlayment shall be formed at the spacing of not less than one weep hole per tile. • Fastening Options for Adhesive Set Tile Installations For roof slopes greater than 7:12, fasten every tile in addition to the adhesive. When utilizing battens and tiles with protruding anchor lugs, fastening is not required in addition to the adhesive. Flat/Low, Medium and High Profile Tile - Tile shall be I ttached to resist the aerodynamic moment as determined when using the design pressures for the building and the attachment calculations set forth in the local building code. I Starting at the eave, make certain the tile overhangs the drip edge uniformly along the first course. The tile shall over- hang the eave line by at least 3/4" but not more than 2". Secure tiles with Nails, Screws, Foam/Adhesive or Mortar. Slee Attachment Resistance Values per Tables I & 2 in Appendix A. Cut/break tile for proper staggering of the courses when using' staggered/cross bond method of installation. Set tile in stepped course fashion or in a horizontal and/or vertical fash- loln when utilizing straight bond method. Lay succeeding courses of field tile in same manner. Cut/break field tile to form straight edge at center of hip/ridge. Valleys - It is not recommended to install trim tile in the val- leys. It may be necessary to remove the lugs from the field the at walls and valley flashings for proper positioning of cut field tiles. Choose one of the following. • Valley metal without Water Diverters. See Drawing . FHW 03. Closed Valley - Miter tile to meet at center of valley. See Drawing FHW-03. Open Valley - Chalk a line minimum 2" on both sides of valley center. Place bed of mortar along outside edge of chalk lines on Granular Surfaced underlayment's only. Miter tile to form straight border and point mortar to finish. See Drawing FHW-03. • Valley metal with Water Diverters. Closed Valley - Miter tile to form straight border on either side of water diverters. See Drawing FHW-03. F000tlopeslj I L�up�to antl includtng 6 I L tasCeliers Open Valley - Miter tile to form straight border on are rfot`regwredKm addition to�`theadheswes either side of the two water diverters. See Drawing ,;y}yL;3j1.,i—� J.1.� 'WrL4i� radri:3.e1.. 4. wS.[S.:yW f L.AJ rl�1✓+',FHW-03. For roof slopes.greatewttian,6a 2 and' up to and including 712xfasfen'every the in the first:course andyeiv;ty+third tile eve-F-9tofAIN-d bee i"i'addition•to.:the,adhesive. COPYRIGHT @ FRSA/fILE ROOFING INSTITUTE April 2012