FL #
FL52S9-R27
Application Type
Revision
ing Depattment
Pert.t
Code Version
2017
$t. LUCI2 Count
LU
Application Status
Approved
l ,t-t� 0
ST, tITC)!r COUNTY RUl? DTVI SIGN
R9VVNi"E—o F0XCO1WL 4`C
Archived
E
-VM ; >g7y
DATE V ISi'
Product Manufacturer
USA
PLANS AND PERMIT MUST E KEPT ON Jf
Address/Phone/Email
150 Lyonn Drive
150 Lyon
Fernley, NV 89408
0.11 NO INSPECTION WILL BE NUDE,
(570) 384-1230 Ext 242
jaklns@polyglass.com
Authorized Signature
James Akins
THESE PLANS AND ALL PROPOSED WORK
jakins@polyglass.com
ARE SUBJECT TO ANY CORRECTIONS
Technical Representative
Maury Alpert
REQUIRED BY FIELD INSPECTORS THAT
Address/Phone/Email
1111 W. Newport Center Drive
Deerfield Beach, FL 33442 MAY BE NECESSARY IN ORDER TO
10
COMPLY WITH
MAIp pert@polyglass.com
MAlpert@polyglass.com
I^ CC
� APPLIGA54 WDES,
Quality Assurance Representative
Oriel Lender
CONCEALED FASTENERS OR ATTACHMENTS
Address/Phone/Email
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
ARE THE RESPONSI61LffY
(954) 233-1230
OF THE
ALender@polyglass.com
CONTRACTOR OF RECORD
Category
Roofing
Subcategory
Underlayments
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy
Received
Florida Engineer or Architect Name who developed
Robert Nleminen
the Evaluation Report
Florida License
PE-59166
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
10/05/2018
Validated By
John W. Knezevich, PE
17-1 Validation Checklist - Hardcopy Received
Certificate of Independence
FL 5259 R27 COI 2017 01
COI Nleminen Ddf
Referenced Standard and Year (of Standard)
nd
ASTM D1970
2015
ASTM D226
2009
ASTM D6164
2011
ASTM D6222
2011
FM 4474
2011
FRSA/TRI April 2012
2012
TAS 103
1995
TAS 110
2000
UL 1897
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Method.1 Option D
Date Submitted
09/14/2017
Date Validated
09/15/2017
Date Pending FBC Approval
09/18/2017
Date Approved
12/12/2017
Summary of Products
2012
FL #
Model, Number or Name
Description
5259.1
Polyglass Roof
Roofing underlayments
Underlayments
Limits of Use
Approved for use in HVHZ: No
Installation Instructions
FL5259 R27 II 2017 09 FINAL ER pOLYGLASS UNDERI AYMENTS FL5259-
R27.adf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure in this
application relates to one particular
Evaluation Reports
FL5259 R27 AE 2017 09 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
R 7. nd
underlayment system (over concrete de
k)
for use under foam -on tile systems (where
Created by Independent Third Party: Yes
the underlayment forms part of the load
•
path). Refer to ER Section 5.6.4 for other
systems, other deck types and associated
maximum design pressures. 2.) Refer to
ER Section 5 for other limits of use.
Back Next
Contact Us r• 2601 Blair Stone Road Tallahassee FL 32322 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. 0 pvrlght 2007-2013 State of Florida.:: Pdvacv Statement :. Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public recordsl If you do not want your a -mall address released In response to a public -records request, do not send electronic
mall to this entltV. Instead, contact the office by phone or by tradlUonal mall. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275
/ (1), Florida Statutes, effective October 1, 2022,.licensees licensed under Chapter 455, F.S. must provide the Department with an email address Ifthey have one. The
emalls provided may be used for official communicatlon with the licensee. However email addresses arepublic record. If you do not wish to supply a personal address,
please provide the Department with an email addresss which can be made available to the public. To determine if you area licensee under Chapter 455, F.S., please
click heg,.
Product Approval Accepts:
® �
Credit Card
Safe
P
TRINIIYJ ERD
EVALUATION REPORT
EXTERIOR RESEARCH & DESIGN, I.I.C.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
(203)262-9245
Polyglass USA, Inc. Evaluation Report P12060.02.09-1123
150 Lyon Drive FL5259-R27
Fernley, NV 98408 Date of Issuance: 02/24/2009
(570) 384-1230 Revision 23: 09/14/2017
SCOPE:
This Evaluation Report is issued under Rule 611520-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Coe and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance lwith the ll Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requi
CONTINUED COMPLIANCE: This Evaluation Report is valid
Quality Assurance documentation changes, or provision
Evaluation Report by the named client constitutes agree
referenced Quality Assurance documentation changes.
relative to updated Code requirements with each Code
ements the Accredited Quality Assurance Agency noted herein.
intil such time as the named product(s) changes, the referenced
of the Code that relate to the product change: Acceptance of this
ment to notify Robert Nieminen, P.E. if the product changes or the
TrinityJERD requires a complete review of this Evaluation Report
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the jQb site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 14.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DG4 ANE1983
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquii
distributing products it evaluates.
2. Trinity I ERD is not owned, operated or controlled by any
3. Robert Nieminen, P:E. does not have nor will acquire, a f
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a
product.
5. This is a building code evaluation. Neither Trinity) ERD
project on which this Evaluation Report, or previous vers
specifically for that purpose.
The facsimile seal appearing was authorized by Robert Nleminen,
P.E. on 09/14/2017. This does not serve as an electronically
signed document.
or will it acquire, a financial interest in any company manufacturing or
pany manufacturing or distributing products it evaluates.
:ial interest in any company manufacturing or distributing products for
interest in any other entity involved in the approval process of the
Robert Nieminen, P.E. are, in any way, the Designer of Record for any
thereof, is/was used for permitting or design guidance unless retained
ROOFING COMPONENT EVALUATION:
L. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as prc
following sections of the Sth Edition (2014) Florida Bu
Compliance is subject to the Installation Requirements
2. STANDARDS:
TRINITY ,ERD
luced by Polyglass USA, Inc., have demonstrated compliance with the
ding Code through testing in accordance with the following Standards.
nd Limitations / Conditions of Use set forth herein.
Section
Pro a
Standard
Year
1504.3.1
Wind Uplift
FM 4474
2011
1504.3.1
Wind Uplift
UL 1897
2012
1507.2.3 / 1507.1.1
Physical Properties
ASTM D226
2009
1507.2.4 / 1507.1.1,1507.2.9.2
Physical Prope��Ir�
ASTM D1970
2015
1507.3.3
"""ties
Physical Properties
FRSA/TRI April 2012
2012
1507.11.2
Physical Properties
ASTM D6164
2011
1507.11.2
Physical Prope ties
ASTM D6222
2011
2523.6.5.2.1
Pro a Physical ties
Y P •
TAS 103
1995
TAS 110
Accelerated Weathering
TAS 110
2000
3. REFERENCES:
Enti
Examination
Reference
Date
FM Approvals (TST 1867)
Wind Uplift
3004091
01/12/2000
PRI (TST 5878)
Physical Properties
PRIO1111
04/08/2002
PRI (TST 5878)
Physical Properties
PUSA-005-02-01
01/31/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-01
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-02
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-03
12/23/2002
PRI (TST 5878)
Physical Propelies
PUSA-018-02-01
07/14/2003
PRI (TST 5878)
Physical Properties
PUSA-028-02-01
07/13/2005
PRI (TST 5818)
Physical Properties
PUSA-033-02-01
01/12/2006
PRI (TST 5878)
Physical Properties
PUSA-035-02-01
09/29/2006
PRI (TST 5878)
Physical Properties
PUSA-055-02-02
12/10/2007
PRI (TST 5878)
Physical Properties
PUSH 061-02-02
01/28/2008
PRI (TST 5878)
Physical Properties
PUSA-076-02-01
02/22/2008
PRI (TST 5878)
Physical Properties
PUSA-083-02-01
04/24/2008
PRI (TST 5878)
Physical Properties
PUSA-088-02-01
07/29/2009
MTI (TST 2508)
Physical Properties
JX20117A
04/01/2008
MTI (TST 2508)
Physical Properties
RX14E8A
01/29/2009
ERD (TST 6049)
Physical Properties
11752.09.99-1
02/08/2000
ERD (TST 6049)
Wind Uplift
11757.08.01-1
08/13/2001
ERD (TST 6049)
Wind Uplift
11776.06.02
01/16/2003
ERD (TST 6049)
Physical Properties
02200.07.03
07/14/2003
ERD (TST 6049)
Wind Uplift
P1740.01.07
01/04/2007
ERD (TST 6049)
Physical Properties
P5110.04.07-1
04/12/2007
ERD (TST 6049)
Wind Uplift
P9260.03.08
03/21/2008
ERD (TST 6049)
Physical Properties
P33450.08.09
08/13/2009
ERD (TST 6049)
Wind Uplift
P30540.11.09-R1
11/30/2009
ERD (TST 6049)
Physical Properties
P11030.11.09-1
11/30/2009
ERD (TST 60491
Wind Uplift
P11030.11.09-2
11/30/2009
ERD (TST 6049)
Physical Properties
P11030.11.09-3
11/30/2009
ERD (TST 6049)
Physical Properties
P33360.06.10
06/25/2010
ERD (TST 6049)
Physical Properties
P33370.03.11
03/02/2011
ERD (TST 6049)
Physical Properties
P33379.04.11
04/26/2011
ERD (TST 6049)
Physical Properties
P37300.10.11
10/19/2011
Exterior Research and Design, LLC.
Evaluation Report P12060.02.09-1123
Certificate of Authorization #9503
a EDITION (2017) FBC NON-HVHZ EVALUATION
FL5259-R27
Polyglass Roof (570) 384-2230
Revision 23: 09/14/2017
inderlayments,
Page 2 of 14
TRINITY! ERD
Entity
Examination
Reference
Date
ERD (TST 6049)
Physical Properties
P40390.08.12-1
08/06/2012
ERD (TST 6049)
Physical Properties
P40390.08.12-2
08/07/2012
ERD (TST 6049)
Physical Properties
C41420.09.12-3
09/11/2012
ERD (TST 6049)
Wind Uplift
P39680.03.13
03/04/2013
ERD (TST 6049)
Physical Properties
P45370.04.13
04/26/2013
ERD (TST 6049)
Wind Uplift
P1738.02.07-112
04/29/2013
ERD (TST 6049)
Wind Uplift
11757.04.01-1-R1
04/30/2023
ERD (TST 6049)
Wind Uplift
P41630.08.13
08/06/2013
ERD (TST 6049)
Wind Uplift
P11751.05.03-Ri
11/26/2013
ERD (TST 6049)
Wind Uplift
P11781.11.03-R1
11/26/2013
ERD (TST 6049)
Physical Properties
P45270.05.14
05/12/2014
ERD (TST 6049)
Physical Properties
6020.07.14-1
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-2
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-3
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-4
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-5
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-6
09/08/2014
ERD (TST 6049)
Physical Properties
P46520.10.14
10/03/2014
ERD (TST 6049)
Physical Properties
P44360.10.14
10/07/2014
ERD (TST 6049)
Physical Properties
P43290.10.14
10/17/2014
ERD (TST 6049)
Physical Properties
PLYG-SC7550.03.15
03/24/2015
ERD (TST 6049)
Physical Properties
P40390.04.15
04/03/2015
ERD (TST 6049)
Physical Properties
PLYG-SC8080.05.15-1
05/20/2015
ERD (TST 6049)
Wind Uplift
PLYG-SC8905.05.16-1
05/17/2016
ERD (TST 6049)
Physical Properties
PLYG-SC8080.07.16
07/16/2016
ERD (TST 6049)
Wind Uplift
PLYG-SC12025.10.16
10/12/2016
ERD (TST 6049)
Physical Prop rties
PLYG-SC13040.12.16
12/27/2016
ERD (TST 6049)
Physical Properties
PLYG-SC11900.03.17
03/10/2017
ERD (TST 6049)
Physical Properties
PLYG-SC12115.08.17
08/08/2017
ICC-ES (EVL 2396)
IBC Compliance
ESR-1697
11/01/2014
Miami -Dade (CER 1592)
HVHZ Compliance
NCIA 14-0717.08
01/22/2015
Polyglass USA
Manufacturing Affidavit
Products Current
02/18/2009
Polyglass USA
P/L Affidavit I
Mule -Hide Cross Ltg
03/01/2009
Polyglass USA
Materials Affidavit
Polystick SA Compound
08/18/2011
UL, U.C. (QUA9625)
Quality Control
Service Confirmation
Exp.10/05/2018
4. PRODUcr DESCRIPTION:
`Mechanically Fastened Untlerlayin s
4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet.
4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet.
4.1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet.
4.1.4 Polyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet.
4:2 Self=AdherlrrgUnderlayments' � -
4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced
with polyolefinic film surface; meets TAS 103.
4.2.2 Polystick IR-Xe is a nominal 60-mil thick ru befized asphalt waterproofing membrane, glass fiber reinforced, with an
aggregate surface; meets ASTM D1970.
4.2.3 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a
polyester fabric surface; meets ASTM D1970 and TAS 103.
Exterior Research and Design, LLC
Certlflcate ofAuthorization #9503
6'x EDITION 12017) FBC NON-HVHZ EVALUATION
Polyglass Roof Underlayinents; (570) 384-1230
Evaluation Report P12060.02.09-1123
FL5259-RZ7
Revision 23: 09/14/2017
Page 3 of 24
s
TRINITY !ERD
i I
4.2.4 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester
reinforced, with a granular surface; meets ASTM D1970 and TAS 103.
4.2.5 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester
fabric surface; meets ASTM D1970 and TAS 103.
4.2.6 Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are polyester
reinforced, APP modified bitumen cap sheets; meet FRSA/TRI April 2012.
4.2.7 Polystick Dual Pro' is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; Teets ASTM D1970.
4.2.8 Polystick Tile Pro"" is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a,polyesterfabric surface; meets ASTM D1970 and TAS 103.
4.2.9 Polystick MU-X is a nominal 54-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section
5.8).
4.3 Mechanically'Fas 'M is rld/oc Bonded Underlaytnents�
4.3.1 Elastoflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of a sand -surfaced SBS
modified bitumen back -side and granule -surfaced APP modified bitumen top -side. Elastoflex G TU is for use as an
alternate to "Mineral Surface Roll Roofing, (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened the roof systems or Hot Asphalt applied "Cap Sheet" in the "Two Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered the roof systems.
4.3.2 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced, SBS modified bitumen cap sheets; meet ASTM D6164.
Elastoflex S6 G and Elastoflex S6 G FR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380,
Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems.
Elastoflex S6 G is for use as an alternate t i Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI
April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 G FR is for use as an
alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath
mechanically fastened the roof systems.
4.3.3 Polyflex G and Polyflex G FR are polyester_ reinforced, APP modified bitumen cap sheets; meet ASTM D6222.
Polyflex G is for use as an alternate to Heat Applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI April 2012
(04-12) beneath mechanically fastened or adhered tile roof systems. Polyflex G FR is for use as an alternate to Heat
Applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI April 2012• (04-12) beneath mechanically fastened tile
roof systems.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product. j
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
Exterior Research and Design, I.I.C.
cer0/icate of Authorization #9503
6TM EDITION (2017) FBC NON-HVHZ EVALUATION
Polyglass Roof Underlayments; (570) 3W1230
Evaluation Report P12060.02.09-R23
FLSZ59-RZ7
Revision 23; 09/14/2017
Page 4 of 14
TRINITY' ERD
5.5 Allowable Roof Covers:
TABLE
i:• RIoo.F:COVER O.PTIONs
Underlayment
Asphalt Shingles
Nail -On
Tile
Foam -on Tile
Metal
Wood Shakes
& Shingles
Slate
ElaStobase
Yes
(Base Sheet In 2--ply
system)
(Base Sheet In 2-ply system)
YES
YES
YES
Elastobase P
Yes
Yes
(Base Sheet ln2-ply
I
system)
Yes
(Base Sheet ln2-ply system)
Yes
Yes
Yes
Polyglass G2Base
No
(awe Sheet in2-ply
system)
es
(Base Sheet iln2-ply system)
No
No
No
Polyglass APP Base
No
Yes
(Base Sheet in 2-ply
system)
Yes
(Base Sheet in 2-ply system)
No
No
No
Polystick MTS
Yes
Yes
No
Yes
Yes
Yes
Polystick IR-Xe
Yes
No
No
No
Yes
Yes
PolystickTUP
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polystick TU Plus
Yes
Yes
Yes (See 5.5.1)
Yes
Yes
Yes
Polystick TU Max
No
Yes
Yes (See 5.5.1)
Yes
No
No
Polystick Dual Pro
Yes
No
No
Yes
Yes
Yes
Polystick Tile Pro
Yes
Yes
Yes (See 5.5.1)
Yes
Yes
Yes
Polystick MU-X
Yes
No
No
Yes
Yes
Yes
Elastoflex S6 G
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Elastoflex S5 G FR
Yes
Yes
No
No
Yes
Yes
Elastoflex G TU
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polyflex G
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polyflex G FR
Yes
Yes
No
No
Yes
Yes
Polyflex SAP or SAP FR
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Mule -Hide SA-APP Cap Sheet
or SA-APP Cap Sheet (FR)
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
5.5.1 "Foam -On Tile" is limited to use of the following Approved the adhesives / underlayment combinations.
TABLE ZA:.'ALLOWABLE
PILE
ADHESIVE UNDERLAifM1eNTCOM81NA710NS
Adhesive
Florida Product
Underlayments
Approval
I
DAP Foam Touch in Seal Storm Bond Roof
FL14506
Polystick TU Plus, Polystick TU Max
Tile Adhesive
Dow TileBond"'
FL22525
Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
ICP Adhesives Polyset® AH-160
FL6332
Elastoflex G TU, Elastoflex 56 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR,
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
ICP Adhesives Polyset® RTA-1
FL6276
Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR,
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
Polyglass Polyl.ok Roof Tile Adhesive
FL17855
Polystick TU Plus or Polystick TU Max
z Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design, I.I.C. Evaluation Report 1312060.02.09-1123
Certificate afAuthorization 99503 6t" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 5 of 14
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Polystick (all variations), Dual Pro, Tile Pro,
(FR) self -adhered to:
➢ New untreated plywood; ASTM D41 prig
plywood; New or existing, unprimed (
Southern Yellow Pine; ASTM D41 prin
(designed and installed to meet wind loi
TRINITY I ERD
SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet
J new untreated plywood; Existing plywood; ASTM D41 primed existing
1, ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
structural concrete; Huber Engineered Woods "ZIP System" Panels
for project).
Note: Polyglass does not require priming of �ew or existing plywood or OSB sheathing. New or existing plywood or
0SB sheathing should be cleaned of all dirt arld debris prior to application of Polystick membranes.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hat asphalt to:
➢ ASTM D41 primed structural concrete.
Polyflex G or Polyflex G FR torch -applied to:
➢ ASTM D41 primed structural concrete.
5.6.2 Bond -to -Insulation:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered
to:
➢ ASTM C1289, Type II, Class 1 polyisocypnurate or Type V polyisocyanurate-composite insulation; Dens Deck
DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board.
Elastoflex G TU, Elastoflex S6 G or Elastoflex
➢ Dens Deck Prime or SECUROCK Gypsum-1
Polyflex G or Polyflex G FR torch -applied to:
➢ ASTM D41 primed structural concrete; Di
For installation under mechanically attach,
requirements of the prepared roof covering
systems, insulation attachment shall be des
the insulation/underlayment system in acco
5.6.3 Bond to Mechanically Attached Base Laver:
Polystick (all variations), Polyflex SAP or SA
Tile Pro self -adhered to:
➢ ASTM D226, Type I or II felt; Elastobase; I
Elastoflex G TU, Elastoflex S6 G or Elastoflex
➢ ASTM D226, Type I or II felt; Elastobase; I
Polyflex G or Polyflex G FR torch -applied to:
➢ Elastobase; Elastobase P, Mule -Hide Nail
For installations under mechanically attach
codified requirements. For installations u
requirements of FRSA/TRI April 2012 (04-1i
accordance with FBC Section 1504.3.1.
G FR in hot asphalt to:
:r Roof Board.
Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
i prepared roof coverings, insulation shall be attached per minimum
manufacturer's Product Approval. For installations under foam -on tile
ned by a qualified design professional and installed based on testing of
lance with FBC Section 1504.3.1.
FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or
P or Mule -Hide Nail Base.
G FR in hot asphalt to:
tobase P, Mule -Hide Nail Base or Polyglass G2 Base.
Polyglass G2 Base or Polyglass APP Base.
I prepared roof coverings, base layer shall be attached per minimum
ler foam -on the systems, base layer shall be attached per minimum
Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-R23
Certificate of Authorization A9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof U1 nderlayments; (570) 334-2230 Revision 23: 09/14/2017
Page 6 of 14
5.6.4 Wind Resistance for Underlayment System:
address wind uplift resistance of all underla
forms part of the load -path. The followin
addressed in FRSA/TRI April 2012 (04-12) ani
result of testing for wind load resistance ba!
divided by 2 (the 2 to 1 margin of safety per
12), Appendix A, Table 1A or FBC 1609 for de
#1 Maximum Design Pressure = -90 psf:
Deck: Min.15/32-inch plywood to meet
Primer: None
Underlayment: Polystick TU P, Polystick TU Plus, F
Mule -Hide SA-APP Cap Sheet (FR),
#2
Maximum Design Pressure = -97.5 psf:
Deck: Min. 15/32-inch plywood to meet
Primer: PG100 or ASTM D41
Underlayment: Polystick TU P, Polystick TU Plus, F
Mule -Hide SA-APP Cap Sheet (FR).
1Y." ring shank nails through 32 ga
#3
Maximum Design Pressure = -105 psf:
Deck: Min. 15/32-inch plywood to meet
Primer: WB-3000
Underlayment: Polystick TU P, Polystick TU Plus, F
Mule -Hide SA-APP Cap Sheet (FR)
1Y4" ring shank nails through 32 ga
#4
Maximum Design Pressure = -135 psf:
Deck: Min. 15/32-inch plywood to meet
Primer: (Optional) PG100orASTM D41
Joints: Min. 4-inch wide strips of Elastofle
Underlayment: Polystick TU P, Polystick TU Plus, F
Mule -Hide SA-APP Cap Sheet (FR),
#5
Maximum Design Pressure = -315 psf:
Deck: Structural concrete to meet projec
Primer: PG100orASTM D41
Underlayment: Polystick TU P, Polystick TU Plus,
Sheet and Mule -Hide SA-APP Cap;
I
TRINITY, ERD
in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not
rent systems beneath foam -on tile systems, where the underlayment
wind uplift limitations apply to underlayment systems that are not
are used in foam -on tile applications. Maximum Design Pressure is the
ad on allowable wind loads, and reflects the ultimate passing pressure
BC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-
irmination of design wind loads.
requirements to satisfaction of Authority Having Jurisdiction.
TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
requirements to satisfaction of Authority Having Jurisdiction.
Ilystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
self -adhered and back -nailed within the selvedge -edge side laps using 12 ga, x
1-5/8" diameter tin caps spaced 12-inch o.c.
requirements to satisfaction of Authority Having Jurisdiction.
Ilystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
1-5/8" diameter tin caps spaced 12-inch o.c.
requirements to satisfaction of Authority Having Jurisdiction.
K SA-V over all plywood joints.
olystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
self -adhered.
requirements to satisfaction of Authority Having Jurisdiction.
ick TU Max, Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap
(FR), self -adhered.
#6 Maximum Design Pressure = -622.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied.
#7 Maximum Design Pressure = -30.0 psf*:
Deck: Min. 15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side) laps and 6-inch o.c. at two (2) equally spaced staggered center rows. '
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#8 Maximum Design Pressure = -37.5 psf*: I
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
Exterior Research and Design, LLC. I Evaluation Report P12060.02.09-R23
Certificate of Authorization #9503 6i" EDITION (20117) F8C NON-HVHZ EVALUATION FL5Z59-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 7 of 14
I TRINITY I ERD
#9 Maximum Design Pressure = -37.5 psf*:
Deck:
Min. 19/32-inch plywood to meet
project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
One (1) or two (2) layers ASTM D226,
Type II felt
Fasteners:
11 ga. x 1.25-inch long x 1-inch head
diameter round metal cap nails
Spacing:
6-inch o.c. at the 3-inch wide side
laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,
applied in full mopping of hot asphalt.
#10 Maximum Design Pressure = -45 psf*:
Deck:
Min.19/32-inch plywood to meet
project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
One (1) layer ASTM D226, Type II
felt
Fasteners:
11 ga. x 1.25-inch x 3/8-inch head
diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing:
4-inch o.c. at the 2-inch wide side
laps and 4-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus, polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex G TU, applied in full mopping of hot asphalt.
#11 Maximum Design Pressure = -45 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two (2) layers ASTM D226, Type II felt
Fasteners: it ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 9-inch o.c. at the 2-inch wide sidel laps and 9-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR)I self -adhered or Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot
asphalt.
#12 Maximum Design Pressure =-45 psf:
Deck: Min. 15/32-Inch plywood to me
Base Sheet: Elastobase (sanded top surface
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 2-inch wide sii
Underlayment: Elastoflex G TU or Elastoflex S6
#13 Maximum Design Pressure = -52.5 psf:
Deck: Min. 15/32-inch plywood to me
Base Sheet: Elastobase (sanded top surface
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 2-inch wide si
Underlayment: Elastoflex G TU or Elastoflex S6
#14 Maximum Design Pressure = -52.5 psf:
Deck: Min.15/32-inch plywood to mi
Base Sheet: Elastobase or Mule -Hide Nail B
Fasteners:
Spacing:
Underlayment:
Simplex Original Cap Nails
6-inch o.c. at the 3-inch wide
project requirements to satisfaction of Authority Having Jurisdiction.
r hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
laps and 18-inch o.'c. at two (2) equally spaced staggered center rows.
applied in full mopping of hot asphalt or Polyflex G, torch -applied.
project requirements to satisfaction of Authority Having Jurisdiction.
r hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
applied in full mopping of hot asphalt or Polyflex G, torch -applied.
project requirements to satisfaction of Authority Having Jurisdiction.
(poly -film top surface)
laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#15 Maximum Design Pressure = -52.5 psf:
Deck: Min. 15/32-inch plywood to me
Base Sheet: Elastobase (sanded top surface
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c. at the 3-inch wide sii
Underlayment: Elastoflex G TU or Elastoflex S6
#16 Maximum Design Pressure = -60 psf:
Deck: Min. 19/32-inch plywood to me
Base Sheet: Elastobase (sanded top surface
Fasteners: 11 ga. x 1.25-inch long x 3/8-in(
Spacing: 8-inch o.c. at the 4-inch wide si
Underlayment: Elastoflex G TU or Elastoflex S6
project requirements to satisfaction of Authority Having Jurisdiction.
r hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
applied in full mopping of hot asphalt or Polyflex G, torch -applied.
project requirements to satisfaction of Authority Having Jurisdiction.
r hot -asphalt ortorch-applied cap or poly -film surface for torch -applied cap)
head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
laps and B-inch o.c. at three (3) equally spaced staggered center rows.
applied in full mopping of hot asphalt or Polyflex G, torch -applied.
Exterior Research and Design, I.M.
Certifrcate ofAuthorizationt#9503 e" EDITION (2017) FBC NON-HVHZ EVALUATION
Polyglass RoofjUnderlayments; (570) 384-1230
Evaluation Report P12060.02.09-R23
FL5259-R27
Revision 23: 09/14/2017
Page 8 of 14
I
,}
TRINITY ! ERD
#17 Maximum Design Pressure = -60 psf 1
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Cl #12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#18 Maximum Design Pressure = -67.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch hrad diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
#19 Maximum Design Pressure = -75 Dsf
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 10-inch o.c. at the 4-inch wide sides laps and 10-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
#20 Maximum Design Pressure = -90 Dsf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface fo hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side aps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#21 Maximum Design Pressure = -90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface foi hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Fiat Bottom Metal
Plates
Spacing: 6-Inch o.c. at the 4-inch wide side laps and 6-Inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#22 Maximum Design Pressure = -90 psf:
Deck: Min.15/32-inch plywood to meetlproject requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the flinch wide side.laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
#23 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meetlproject requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with CMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
Exterior Research and Design, LLC. I Evaluation Report P12060:02.09-R23
Certificate ofAuthorization #9503 6r" EDITION (2017) FBC NON-HVH2 EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 354-1230 Revision 23: 09/14/2017
1 Page 9 of 14
#24 Maximum Design Pressure = -97.5 psf
Deck: Min. 19/32-inch plywood to meet
Base Sheet: Elastobase or Mule -Hide -Nail Base
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head
Spacing: 4-inch o.c. at the 4-inch wide side
Underlayment: Polystick TU P, Polystick TU Plus, F
Mule -Hide SA-APP Cap Sheet (FR),
#25
#26
#27
5.6.4.1
5.6.4.2
5.7
5.8
Maximum Design Pressure = -105 Dsf:
Deck: Min. 15/32-inch plywood to meet
Base Sheet: Elastobase (sanded top surface foi
Fasteners: Simplex MAV Cap Fasteners'
Spacing: 6-inch o.c. at the 2-inch wide side
Underlayment: Elastoflex G TU or Elastoflex S6 G,
Maximum Design Pressure = -120 psf:
Deck: Min. 15/32-inch plywood to meet
Base Sheet: Elastobase (sanded top surface fol
Fasteners: OMG #12 Standard Roofgrip or Of
Plates
Spacing: 6-inch o.c. at the 4-inch wide side
Underlayment: Elastoflex G TU or Elastoflex S6 G,
Maximum Design Pressure = -120 asf:
Deck: Min. 15/32-inch plywood to meet
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HD
Spacing: 6-Inch o.c. at the 4-inch wide side
Underlayment: Elastoflex G TU or Elastoflex S6 G,
All other direct -deck, adhered Polyglass ur
Design Pressure of -45 psf.
For mechanically attached Base Sheet, the n
that required under FRSA/TRI April 2012 (04-I!
TRINITY 1 ERD
act requirements to satisfaction of Authority Having Jurisdiction.
y-film top surface)
Teter annular ring shank roofing nails at I1-5/8-inch diameter tin caps
and 4-inch o.c. at four (4) equally spaced staggered center rows.
tick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Iroject requirements to satisfaction of Authority Having Jurisdiction.
hot-asphalt.or torch -applied cap or poly -film surface for torch -applied cap)
and 6-inch o.c. at three (3) equally spaced staggered center rows.
led in full mopping of hot asphalt or Polyflex G, torch -applied.
Iroject requirements to satisfaction of Authority Having Jurisdiction.
hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
IG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal
and 6-inch o.c. at five (5) equally spaced staggered center rows.
led in full mopping of hot asphalt or Polyflex G, torch -applied.
requirements to satisfaction of Authority Having Jurisdiction.
th Trufast 3" Metal Insulation Plates
ps and 6-inch o.c. at five (5) equally spaced. staggered center rows.
3plied in full mopping of hot asphalt.
systems beneath foam -on tile systems carry a Maximum
aximum design pressure for the selected assembly shall meet or exceed
12), Appendix A, Table 1A.
Alternatively, the maximum design pressurj for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density
designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked
with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January
2016) for Zone 2/3 enhancements.
Exposure Limitations:
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days
after installation.
Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation.
Polystick MTS, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or Elastoflex G TU shall not be left exposed for longer than
180-days after installation.
Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30
days.
Elastoflex 56 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the
prepared roof covering is to be adhesive -set the (Elastoflex S6 G or Polyflex G only), in which case the maximum
exposure is 180 days.
i
Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226
roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as
set forth in Section 4.3, Note 1 of ASTM D19I70-15, should be established as to slip resistance.
E I t' R ort P12060 02 09-R23
Exterior Research and Design, U.C. va ua ion ep
certificate afAuthodzation #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-RZ7
Polyglass Roof,Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 10 of 14
TRININ i ERD
5.9 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-121):
When loading roof tiles on the underlaymlent in direct -deck tile assemblies, the maximum roof slope shall be as
fnilows_ These slooe limitations can onlv belexceeded by using battens during loading of the roof tiles.
TABLE 2 'TILE SLIPPAGE !]'V11TAr10NS:FOR
01REc1-DECK TILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum Slope
Elastoflex G TU
Flat
10-tile stack
7:12
Lugged
8-tile stack (6 over 2)
6:12
Elastoflex S6 G or S6 G FR
Flat or Lugged,
6-tile stack (4 over 2)
4:12
Polystick MTS
Flat or Lugged,
Prohibited without battens
N/A
Polystick Tile Pro
Flat or Lugged
6-tile stack (4 over 2)
7:12
Polystick TU Max
Flat
6-tile stack (4 over 2) or 10-tile stack
7:12
Lugged
6-tile stack (4 over 2)
7:12
Lugged
30-tile stack
6:12
Polystick TU P
Flat
6-tile stack (4 over 2)
6:12
Lugged
6-tile stack (4 over 2)
4:12
Polystick TU Plus
Flat or Lugged
6-tile stack (4 over 2)
7:12
Flat or Lugged
10-tile stack
6:12
Polyflex G or G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polyflex SA P or SA P FR
Flat or Lugged
6-tile stack (4 over 2)
4iU
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and chI ck for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (if applicable).
f 3 Rlasto�ase, Elastobase P or, Mule If idle Nail Base
6.3.1 Non Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Table
1507.1.1 for the type of prepared roof cov9ring to be installed.
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA
P Fit, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or
Elastoflex S6 G FR in hot asphalt or Polyflex G Or Polyflex G FR, torch applied. Roof cover limitations are those are
those associated with the top -layer underlayment, as set forth in Table 1.
6.3.2 Tile Applications:
Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the "Two
Ply System" from FRSA/TRI April 2012 (04112). Reference is made to Table 1 and Section 5.6.4 herein, coupled with
FRSA/TRI April 2012 (04-12) Installation Manual.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R23
Certificate of Authorization #9503 6' EDITION (20171 FBC NON-HVHZ EVALUATION FL5259-RZ7
Polyglass Roof underlayments; (570) 384-1230 Revision 23: 09/14/2017
1 Page 21 of 14
6.4 Pc. m-
ASAAideeSA APF Cap' Sheet (FR)�
Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1507.1.1
for the type of prepared roof covering to be installed.
6.4.1
6.4.2
6.4.3
6.4.4
`. TRINITY ! ERD
All self -adhering materials, with the except!
Cap Sheet or SA-APP Cap Sheet (FIR) should
Hide Back Nailing Guide. Nails shall be corrc
metal disk or Simplex -type metal cap nail,
using the above noted fasteners and spacini
The head lap membrane is to cover the area
All seal -lap seams (selvage laps) must I
firmly rolled with a minimum 28 lb. har
roller to ensure full contact and adhesion.
For Dual Pro and Tile Pro, align the edge
the top sheet to the end of the glue patter
(the sheet will overlap the fabric).
All over -fabric and over -granule end -laps
Wet/Dry Cement or Polyglass PG500 Mod
Polystick TU Plus, Dual Pro and Tile Pro m
or exposed roof to wall details
Repair of Polystick membranes is to be acc
Polyglass PG500 Modified Cement to th
Polystick material• of like kind, set and h
installed in a water shedding manner.
All Polystick membranes shall be installs
minimum of 40-lb weighted -roller or, on
for the field membrane. Hand rollers are
roof that are not accessible to a large rolle
I of Polystick TU Plus, Polyflex SAP or SAP FIR and Mule -Hide SA-APP
back -nailed in,selvage edge seam in accordance with Polyglass / Mule -
on resistant, 11 gauge ring -shank type with a minimum 1-inch diameter
a minimum rate of 12" o.c. Polystick TU Plus should be back -nailed
in area marked "nail area, area para clavar" on the face of membrane.
Bing back -nailed.
View of ovelap Seam of Dual Pro and rile Pro
ill have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified
id Cement applied in between the application of the lap.
not be used in any exposed application such as crickets, exposed valleys,
mpllshed by applying Polyplus 50 Premium Modified Wet/Dry Cement or
area in need of repair, followed by a minimum 6 x 6 inch patch of the
id rolled in place over the repair area. Patch laps, if needed, shall be
to ensure full contact with approved substrates. Polyglass requires a
:ep slopes, use of a stiff broom with approximately 40-lbs of load applied
ceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the
or broom.
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base
Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1.
For adhesive -set tile applications, refer to Section 5.6.4 herein.
For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile.
Two (2) Ply Underlavment Systems:_
Polystick MTS followed by Polystick MTS, iTU P, TU Plus, TU Max, Tile Pro, MU-X or Polyflex SAP is allowable for use
under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material.
This is not a requirement, but is allowable if a 2-ply underlayment system is desired.
Exterior Research and Design, I.I.C.
Certijlcate of Autharizatlon #9503
I
CP EDITION (2017) FBC NON-HVHZ EVALUATION
Polyglass Roi underlayments; (s70) 384-1230
I
I
Evaluation Report P12060.02.09-R23
FL5259-RZ7
Revision 23: 09/14/2017
Page 12 of 14
TRINITY I ERD
6:5 Elastoflex G TU Elastoflex S6 G or Elastoflex S6G FR
..:
6.5.1 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be installed in compliance with current Polyglass published
installation requirements. For use in tile applications:
✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply System from FRSA/TRI April 2012 (12) beneath mechanically fastened tile roof.systems or the Hot Asphalt
applied "Cap Sheet" in the `Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the Two Ply 5yst m" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G FR is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply System' from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the `Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
6.5.2 For hot -asphalt -applications, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be fully asphalt -applied to the
substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set
minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt
with asphalt extending approximately 3/8-inch beyond the lap edge.
6.6 ; Polyflei G or Polyflex,G; FR >; •, ::.'
6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements.
For use in tile applications:
✓ Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet" in the `Two Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened or adhered tile roof systems (Base Sheet Limited per 5.6.3).
✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet" in the Two Ply System" from FRSA/TRI
April 2012 (04-12) beneath mechanically fastened tile roof systems (Base Sheet Limited per 5.6.3),
6.6.2 Polyflex G or Polyflex G FR shall be fully torch -applied to the substrates noted in Section 5.6. Side laps shall be
minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end
laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap
edge.
6.7 Tile Stasina:
6.7.1 Tile shall be loaded and staged in a manner that prevents the slippage and/or damage to the underlayment. Refer to
Table 2 herein, and Polyglass published requirements for tile staging.
6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2022 (04-12) must be used
on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or sail-
boards, to prevent tile sliding and/or damage to the underlayment during the loading process.
6.7.3 Polyglass specifies the minimum cure time after installation of self -adhering membranes and before loading of
roofing tiles is forty-eight (48) hours.
I
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-1123
Certificate ofAdthorization A9503 dm EDITION (2017) FBC NON-H VHZ EVALUATION FLSZS9-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 13 of 14
r TRINITY I ERD
I
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS: II
Contact the noted CA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements. The following
nlants have qualified products under their respective physical properties specifications.
Plant .. ::..•, ':. • r :.Specificafion,
:.
;Produ s , ,
Fernley, NV, Hazleton, PA & Winter Haven, FL
ASTM D1970
Polystick MU-X
Hazleton, PA
M-D 13-0004
Elastoflex G TU
Hazleton, PA & Winter Haven, FL
ASTM D1970
Polystick IR-Xe
ASTM D1970 & TAS 103
Polystick TU Plus
ASTM D1970 & TAS 103
Polystick TU Max
Tuscaloosa, AL
ASTM D4601, Type II
Polyglass 62 Base
Winter Haven, FL
ASTM 15226 (physicals)
Elastobase, Elastobase P
ASTM D6509
Polyglass APP Base
TAS 303
Polystick MTS
ASTM D1970 & TAS 103
Polystick TU P
FRSA/TRI April 2012
Polyflex SAP, Polyflex SA P FR
ASTM D1970
Polystick Dual Pro
ASTM D1970 & TAS 103
Polystick Tile Pro
ASTM D6164
Elastoflex S6, Elastoflex S6 G FR
ASTM ,D6222
Polyflex G, Polyflex G FR
9. QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.corn
- END OF EVALUATION REPORT -
I
I
I
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-1123
Certificate ofAuthorizotion #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 14 of 14