HomeMy WebLinkAboutPRODUCT REPORTProduct'-.•rt Manufacturer: Extreme Metal Fabricators,
2160 SW Poma Drive
Palm City, FL 34990
. ;._ . (772)8724034
Compliant with Florida Building Code 2017 .(0 ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Com pliant: Ke stone Certifications THESE PLANS AND ALL PROPOSED WORK
p y ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
Product: 5 V:Crimp 26GA Steel Roof Panel FBC:Sec. 1507.4.2
Yield strength: 50 ksi min:; Attachedlo min. 15/32".plywood or Wood
Deck w/ min. 0.42 specific gravity with screws. 24" Coverage.
Rib Height 3/8"
Corrosion 'Resista'rit Compliant: FBC Sec.1507.4.3
Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex-Washer'Head wood screw* to penetrate
3/16" min. thru deck or. 5/8" embedment into wood plank. (*or sufficient length to meet
requirements) � l:�q&5 vc
d.
Fastener 2 (Method 2,3, & 4 Attachment):.#10.x 1-1/2" Hex -Washer Head wood screw* to
..penetrate 3/16". min'-thru deck or 5/8" embedment into wood plank. (*or sufficient length
ST. LUCIE COUNTY BUILDIN DIVISIQD 6c rdp
t0 meet requirements) REVIEWED FO %
Underlayment: To be compliant with FBC Sec: Chart 1507.1.9EVIEW D B
DATE:
PLANS AND PE IT MUST BE KEPT ON JOB
Slope: Shall be in compliance with FBC Sec: 1507. SITE OR NO INSPECTIONS) WILL BE MADE
See Fastener attachment specifications above
Install Details: Table. A Allowable Loads '
METHOD 1: °
METHOD'2
METHOD 3:.
METHOD 4:
DESIGN PRESSURE* _: _.
1: -86- PSF
-93.5 PSF
-101 PSF
-228 PSF
ROW. SPACING- -
1 16" o.c:
„
16 o.c.:
„
8 - O.C.
6" o.c.
-FASTENER-SPACING (ALONG, Panel width)
112" o.c. ;
.. , 12" d.c.
.11" O.C.
12" o.c.
FASTENER SIZE.-. _
L .. #9 `
.#10
#10
#10
Reference Data: ARCHITECTURAL TESTING, INC.
TST AID#: 1527 ..
UL 580-06 & 1897-041: Test Report
Ix3893.01=450-18. 05/02/14
:Test Report
F3366:0I-450718 12/28/15:
TAS 125-03 Test Report
D05893.02-450-18 07/22/14
7QUIVAL.ENCY--UL 1897-04 'is.,equ/va/ent to teststandard
UL 1897-1 *Design pressure margin of safety' 2;1
Locke'Bowden, P.E:,does not have, not will acquire a financial
in` i�ry� �r� �cq a rn.qWacturing or distributing products
under this evaluation:
Locke gowden, P.E. is not, owned, operated, or _controlled"
by atty coin parNpini6diaaturei, or distributing products under this
report.
,f
4057
ARE THE RESPONSISUPi, f0F I H6
•S y/
� or ��'� • F P n+ ;'
CO ��TRACT®R OFE�.
-rs oNA, ;����FI LE COP
FL17022.1 5V p (26GA; Steel), :24" Wide Roof P:....A - Details
Limitations:
1. Underlayment to be compliance with current Florida Building, Code (FBC)2017 6th ed.
2. Minimum slope to be'compliant'with Florida Building Code 2017 6th ed.; and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method:1-D
4. Engineering analysis for "project specific:approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is. not part,of this acceptance. Shear diaphragm values:are outside this report.
6. Support framing in compliance w/FBC 2017' 6th ed., Chapter 22 for Steel, Chapter 23 for:Wood and: Chapter 16 for
Structural Loading.
7..This report does not imply warranty, installation, recommended product use outside, of this report.
Fasteners
#9 x 1-112" Min. or p
#10 X 1-1/2" Min. per Table A' for Row 5-V Crimp Roof Panel
Spacing and Design Pressures
He c Washer Head Wood Screws'
�o
h�
,
Deck:
15/32" or greater Plywood, or
Wood plank
.PFrwNALsTPM7I,PNS
PawdLProfile '
Nominal12" Nominal12`'
D.C. O.C.
Fasten '
9 x 1-1/2" Min,. or #10 X'1=1/2" Min. per,
-Table "A" Hex Washer Head Screw
Spaced 12" o.c. across the Panel' Width
Panel Refer to Table "A" for Spacing Along Panel
Overlap Length
Deck-15/32" or greater
Plywood, or
- Wood. plank