Loading...
HomeMy WebLinkAboutPRODUCT REPORTProduct'-.•rt Manufacturer: Extreme Metal Fabricators, 2160 SW Poma Drive Palm City, FL 34990 . ;._ . (772)8724034 Compliant with Florida Building Code 2017 .(0 ed.) Compliant with Florida Product Approval Rule # 61G20-3 Com pliant: Ke stone Certifications THESE PLANS AND ALL PROPOSED WORK p y ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. Product: 5 V:Crimp 26GA Steel Roof Panel FBC:Sec. 1507.4.2 Yield strength: 50 ksi min:; Attachedlo min. 15/32".plywood or Wood Deck w/ min. 0.42 specific gravity with screws. 24" Coverage. Rib Height 3/8" Corrosion 'Resista'rit Compliant: FBC Sec.1507.4.3 Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex-Washer'Head wood screw* to penetrate 3/16" min. thru deck or. 5/8" embedment into wood plank. (*or sufficient length to meet requirements) � l:�q&5 vc d. Fastener 2 (Method 2,3, & 4 Attachment):.#10.x 1-1/2" Hex -Washer Head wood screw* to ..penetrate 3/16". min'-thru deck or 5/8" embedment into wood plank. (*or sufficient length ST. LUCIE COUNTY BUILDIN DIVISIQD 6c rdp t0 meet requirements) REVIEWED FO % Underlayment: To be compliant with FBC Sec: Chart 1507.1.9EVIEW D B DATE: PLANS AND PE IT MUST BE KEPT ON JOB Slope: Shall be in compliance with FBC Sec: 1507. SITE OR NO INSPECTIONS) WILL BE MADE See Fastener attachment specifications above Install Details: Table. A Allowable Loads ' METHOD 1: ° METHOD'2 METHOD 3:. METHOD 4: DESIGN PRESSURE* _: _. 1: -86- PSF -93.5 PSF -101 PSF -228 PSF ROW. SPACING- - 1 16" o.c: „ 16 o.c.: „ 8 - O.C. 6" o.c. -FASTENER-SPACING (ALONG, Panel width) 112" o.c. ; .. , 12" d.c. .11" O.C. 12" o.c. FASTENER SIZE.-. _ L .. #9 ` .#10 #10 #10 Reference Data: ARCHITECTURAL TESTING, INC. TST AID#: 1527 .. UL 580-06 & 1897-041: Test Report Ix3893.01=450-18. 05/02/14 :Test Report F3366:0I-450718 12/28/15: TAS 125-03 Test Report D05893.02-450-18 07/22/14 7QUIVAL.ENCY--UL 1897-04 'is.,equ/va/ent to teststandard UL 1897-1 *Design pressure margin of safety' 2;1 Locke'Bowden, P.E:,does not have, not will acquire a financial in` i�ry� �r� �cq a rn.qWacturing or distributing products under this evaluation: Locke gowden, P.E. is not, owned, operated, or _controlled" by atty coin parNpini6diaaturei, or distributing products under this report. ,f 4057 ARE THE RESPONSISUPi, f0F I H6 •S y/ � or ��'� • F P n+ ;' CO ��TRACT®R OFE�. -rs oNA, ;����FI LE COP FL17022.1 5V p (26GA; Steel), :24" Wide Roof P:....A - Details Limitations: 1. Underlayment to be compliance with current Florida Building, Code (FBC)2017 6th ed. 2. Minimum slope to be'compliant'with Florida Building Code 2017 6th ed.; and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method:1-D 4. Engineering analysis for "project specific:approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is. not part,of this acceptance. Shear diaphragm values:are outside this report. 6. Support framing in compliance w/FBC 2017' 6th ed., Chapter 22 for Steel, Chapter 23 for:Wood and: Chapter 16 for Structural Loading. 7..This report does not imply warranty, installation, recommended product use outside, of this report. Fasteners #9 x 1-112" Min. or p #10 X 1-1/2" Min. per Table A' for Row 5-V Crimp Roof Panel Spacing and Design Pressures He c Washer Head Wood Screws' �o h� , Deck: 15/32" or greater Plywood, or Wood plank .PFrwNALsTPM7I,PNS PawdLProfile ' Nominal12" Nominal12`' D.C. O.C. Fasten ' 9 x 1-1/2" Min,. or #10 X'1=1/2" Min. per, -Table "A" Hex Washer Head Screw Spaced 12" o.c. across the Panel' Width Panel Refer to Table "A" for Spacing Along Panel Overlap Length Deck-15/32" or greater Plywood, or - Wood. plank