HomeMy WebLinkAboutENERGY EFFICIENCY CODE REC rn� SCANNED
FORM R405-2017 BY �
FLORIDA E ER& E'FF�iblE CY 66WEWU BUILDING CONSTRUCTION
Florida Depa rofessional Regulation - Residential Performance Method
Project Name: VERDONCK REMODEL Builder Name: DON HINKLE CONSTRUCTION
Street: 267 BERMUDA BEACH DRIVE Permit Office: ST. LUCIE COUTNY
City,State,Zip: FT.PIERCE,FL, Permit Number:
Owner: VERDONCK I Jurisdiction: ST.LUCIE COUNTY
Design Location: FL,Fort Pierce i County:: St.Lucie(Florida Climate Zone 2)
1. New construction or existing Addition I 9. Wall Types(828.0 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul, Exterior R=4.1 828.00 ftz
b. N/A R= ftz
3. Number of units,if multiple family 1 c.N/A R= ftz
4. Number of Bedrooms(Bedrms In Addition) 3(2) d.N/A R= ft2
5. Is this a worst case? No I 10.Ceiling Types (1278.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1278.00 ftz
6. Conditioned floor area above grade(ftz) 1278 b.N/A R= ftz
Conditioned floor area below grade(ftz) 0 I c. R= ftz
11.Duct
s R ftz
7. Windows(207.4 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:KITCHEN/DINING 6 125
a. U-Factor: Dbl, U=0.65 125.40 ftz
SHGC: SHGC=0.25
b. U-Factor: Dbl, U=0.65 82.00 ftz 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.30 a.Central Unit 29.4 SEER:16.00
c. U-Factor: N/A ftz
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ftz a.Electric Strip Heat 27.0 COP:1.00
SHGC:
Area Weighted Average Overhang.Depth: 2.000 ft.
Area Weighted Average SHGC: 0.270 14.Hot water systems-None required
8. Floor Types (1278.0 sqft.) Insulation Area a. Cap: N/A
EF:-35.496
a.Slab-On-Grade Edge Insulation R=0.0 1278.00 ftz I b. Conservation features
b. N/A R= ftz
c.N/A R= ftz 15.Credits CF,Pstat
I
Glass/Floor Area: 0.162 Total Proposed Modified Loads: 42.62 PASS
Total Baseline Loads: 42.91
I hereby certify that the plans and specifications covered by; Review of the plans and tKE SrA?'
this calculation are in compliance with the Florida Energy specifications covered by this 0��
Code. calculation indicates compliance
TV
with the Florida Energy Code. rrn ''�:.',-j:a:•;: �� O
PREPARED BY' Before construction is completed r '
DATE: this building will be inspected for
compliance with Section 553.908
I hereby certify that this building,as designed, is in compliance Florida Statutes.
with the Florida Energy C n ' COD�yfi �
OWNER/AGENT: wa BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
C^ @%y
U1J
3/15/2018 3:15 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4
- -z
FORM FW5-2047
PROJECT
Title: VERDONCK REMODEL Bedrooms: 3 Address Type: Street Address
Building Type: User Conditioned Area: 1278 Lot#
Owner Name: VERDONCK Total Stories: 1 Block/Subdivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: DON HINKLE CONSTRUCTI Rotate Angle: 0 Street: 267 BERMUDA BEACH
Permit Office: ST.LUCIE COUTNY Cross Ventilation: No County: St.Lucie
Jurisdiction: ST.LUCIE COUNTY Whole House Fan: No City,State,Zip: FT.PIERCE,
Family Type: Single-family FL,
New/Existing: Addition
Comment:
CLIMATE
I
Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
1 Entire House 1278 11502
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 MASTER BEDROO 192 1728 No 2 1 1 Yes Yes Yes
2 M.BATH 54 486 No 0 1 Yes Yes Yes
3 WIC 30 270 !No 0 1 Yes Yes Yes
4 KITCHEN/DINING 412 3708 Yes 0 1 No Yes Yes
5 BEDROOM 2 132 1188 No 1 1 1 Yes Yes Yes
I
6 BATH 2 45 405 INo 0 1 No Yes Yes
7 BEDROOM 3 110 990 INo 1 1 1 Yes Yes Yes
8 FAMILY ROOM 303 2727 !No 0 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio MASTER BEDRO 12 ft 0 192 ft2 ---- 0 1 0
2 Slab-On-Grade Edge Insulatio M.BATH 17 ft 0 54 ft2 ---- 0 1 0
3 Slab-On-Grade Edge Insulatio WIC 6 ft 0 30 ft2 ---- 0 1 0
4 Slab-On-Grade Edge Insulatio KITCHEN/DININ 1 ft 0 412 ft2 ---- 0 1 0
5 Slab-On-Grade Edge Insulatio BEDROOM 2 11 ft 0 132 ft2 ---- 0 1 0
6 Slab-On-Grade Edge Insulatio BATH 2 1 ft 0 45 ft2 ---- 0 1 0
7 Slab-On-Grade Edge Insulatio BEDROOM 3 11 ft 0 110 ft2 ---- 0 1 0
8 Slab-On-Grade Edge Insulatio FAMILY ROOM 35 ft 0 303 ft2 ---- 0 1 0
3/15/2018 3:15 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4
r
FORM k05-2047 -�
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 1347 ft2 0 ft2 Medium 0.6 No 0.9 No 0 18.4
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented I 300 1278 ft2 N N
(CEILING
# Ceiling Type Space I R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) MASTER BEDRO 30 Blown 192 ft2 0.1 Wood
2 Under Attic(Vented) M.BATH i 30 Blown 54 ft2 0.1 Wood
3 Under Attic(Vented) WIC 30 Blown 30 ft2 0.1 Wood
4 Under Attic(Vented) KITCHEN/DININ 30 Blown 412 ft2 0.1 Wood
5 Under Attic(Vented) BEDROOM 2 30 Blown 132 ft2 0.1 Wood
I
6 Under Attic(Vented) BATH 2 30 Blown 45 ft2 0.1 Wood
7 Under Attic(Vented) BEDROOM 3 30 Blown 110 ft2 0.1 Wood
8 Under Attic(Vented) FAMILY ROOM 1 30 Blown 303 ft2 0.1 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below rnt In Wall T
-Igpe
_ 1 N Exterior Concrete Block-Ext IndMASTER BE '4.1 12 0 9 0 108.0 ft2 0 0 0.6 0
2 N Exterior Concrete Block-Ext InsuM.BATH 4.1 $ 0 9 0 45.0 ft2 0 0 0.6 0
3 E Exterior Concrete Block-Ext InsuM.BATH 4.1 11 0 9 0 99.0 ft2 0 0 0.6 0
4 W Exterior Concrete Block-Ext InsuM.BATH 4.1 1 0 9 0 9.0 ft2 0 0 0.6 0
i
_ 5 E Exterior Concrete Block-Ext Insul WIC 4.1 6 0 9 0 54.0 ft2 0 0 0.6 0
I
6 W Exterior Concrete Block-Ext In&EDROOM 2 14.1 11 0 9 0 99.0 ft2 0 0 0.6 0
7 S Exterior Concrete Block-Ext InfiffDROOM 3 4.1 11 0 9 0 99.0 ft2 0 0 0.6 '0
8 N Exterior Concrete Block-Ext In€iAMILY ROO 4.1 19 0 9 0 171.0 ft2 0 0 0.6 0
_ 9 W Exterior Concrete Block-Ext InMAMILY ROO ' 4.1 16 0 9 0 144.0 ft2 0 0 0.6 0
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 N 1 Metal Low-E Double Yes 0.65 0.25 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None
2 W 6 Metal Low-E Double Yes .0.65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None
3 S 7 Metal Low-E Double Yes 0.65 0.25 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None
4 N 8 Metal Low-E Double Yes 0.65 0.3 N 82.0 ft2 2 ft 0 in 1 ft 4 in None None
5 W 9 Metal Low-E Double Yes 0.65 0.25 N 20.4 ft2 2 ft 0 in 1 ft 4 in None None
6 W 9 Metal Low-E Double Yes 0.65 0.25 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None
3/15/2018 3:15 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2017
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .0004 1341.9 73.67 138.54 .2922 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Strip Heat/Existing/co None COP:1 27 kBtu/hr 1 sys#1
i
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/Existing/confirme Split SEER: 16 29.4 kBtu/hr cfm 0.8 1 sys#1
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
ftz
DUCTS
/ ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 125 ft2 Attic 45 ftZ Default Leakage KITCHEN/ (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Cooling Jan Feb Mar A r Ma X Jun ri
Jul X Au X Se Oct Nov Dec
Venting Jan Feb Feb �Xj Mar �Xj Apr May I IJun Jul Aug Sep �X�Oct �X�Nov HDec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
3/15/2018 3:15 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4
1
2017 -AIR'BARRIER AND INSU''t?° _'ION INSPECTION COMPONENT C'U%-�ERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: VERDONCK REMODEL Builder Name: DON HINKLE CONSTRUCTION
Street: 267 BERMUDA BEACH DRIVE Permit Office: ST.LUCIE COUTNY
City,State,Zip: FT.PIERCE,FL, Permit Number:
Owner: VERDONCK Jurisdiction: ST.LUCIE COUNTY
Design Location: FL,Fort Pierce
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA
General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall
The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material.
requirements Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit
Ceiling/attic the insulation and any gaps in the air barrier,shall be sealed. shall be aligned with the air barrier.
Access openings,drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with
sealed. a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed. minimum.
j Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows,skylights The space between window/doorjambs antl framing,and
and doors skylights and framing shall be sealed.
Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to
(including insulation. maintain permanent contact with the underside of
above-garage subfloor decking,or floor framing cavity insulation
and cantilevered shall be permitted to be in contact with the top side
floors) of sheathing,or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation
a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls
Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit,or narrow
Narrow cavities cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spac Bs.
Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building
shall be sealed to the drywall. thermal envelope shall be airtight and IC rated.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls,or insulation that on
installation readily conforms to available space shall
extend behind p4pong and worffing-
Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall
on exterior wall tubs shall separate them from the showers and tubs. be insulated.
Electrical/phone box or The air barrier shall be installed behind electrical or communication
exterior walls boxes or air-sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub-floor or drywall.
Concealed When required to be sealed,concealed fire sprinklers shall only be
sprinklers I between fire spro a" walls or cellongs
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. In addition,inspection of log walls shall be in accordance with the provisions of[CC-400.
3/15/2018 3:15 PM EnergyGauge®USA-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
i
267 BERMUDA BEACH DRIVE, FT. PIERCE, FL,
1. New construction or existing Addition 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 828.00 ft2
b. N/A R= ft
3. Number of units, if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 3(2) d.N/A R= ft2
5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 1278.00 ft2
6. Conditioned floor area(ft2) 1278 i b.N/A R= ft2
7. Windows- Description Area c. N/A R= ft2
a. U-Factor: Dbl,U=0.65 125.40 ft2 11. Ducts R ft2
a.Sup:Attic,Ret:Attic,AH: KITCHEN/DINING 6 125
SHGC: SHGC=0.25
b. U-Factor: Dbl, U=0.65 82.00 ft2
SHGC: SHGC=0.30 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a.Central Unit 29.4 SEER:16.00
SHGC:
d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency
SHGC: a. Electric Strip Heat 27.0 COP:1.00
Area Weighted Average Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: 0.270
8. Floor Types Insulation Area 14. Hot water systems-None required
Cap:N/A
a.Slab-On-Grade Edge Insulation R=0.0 1278.00 ft2 a. EF:
b.N/A R= ft2
c. N/A R= ft2 b. Conservation features
15.Credits CF,Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building ES
Construction through the above energy saving features which will be installed (or exceeded) V0�� _ ATFo
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code mpliant features.
17
Builder Signature: , Date: o 'l4`j a
Address of New Home: 22{� f �► ^� City/FL Zip: ✓,�,c n �y�S
OD wE'�
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
3/15/2018 3:15 PM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1
I
ect Summary
Pro
-�- wrightsoft® j Date: Nov 06,2017
Enure House By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax.772-466-6796 Email:QUICKCALCS@ OL.COM
I
Proeect Information
For: VERDONCK RESIDENCE
267 BERMUDA BEACH DRIVE, FT. PIERCE,FL
Notes:
I
I
---Desiqn
I Information
Weather: Fort Pierce, FL, US
Winter Design Conditions j Summer Design Conditions
Outside db 42 OF Outside db 90 OF
Inside db 70 OF j Inside db 75 OF
Design TD 28 OF Design TD 15 OF
Daily range L
Relative humidity 50 %
Moisture difference 61 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 13951 Btuh Structure 13744 Btuh
Ducts 4639 Btuh Ducts 6966 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 18590 Btuh Use manufacturer's data n
Rate/swing multiplier 0.95
Infiltration Equipment sensible load 19675 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0, Structure 2642 Btuh
Ducts 1881 Btuh
Central vent (0 cfm) 0 Btuh
Heatingg Coolingg (none)
Area(ftz 1278 1278 Equipment latent load 4523 Btuh
Volume(ft3) 11502 11502
Air changes/hour 0.45 0.23 Equipment total load 24198 Btuh
Equiv.AVF(cfm) 86 44 Req. total capacity at 0.70 SHR 2.3 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make Trane
Trade Trade TRAN E
Model Cond 4TTR4031 L1
AHRI ref Coil TEM6AOC36H31++TDR
AHRI ref 7567544
Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER
Heating input 5.3 kW Sensible cooling 20580 Btuh
Heating output 17924 Btuh Latent cooling 8820 Btuh
Temperature rise 17 OF Total cooling 29400 Btuh
Actual air flow 980 cfm Actual air flow 980 cfm
Air flow factor 0.053 cfm/Btuh Air flow factor 0.047 cfm/Btuh
Static pressure 0.50 in H2O Static pressure 0.50 in H2O
Space thermostat Load sensible heat ratio 0.82
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
WCI htsoft® 2018-Mar-1515:16:24
.`C 9 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1
ACC. ...ments\VERDONCK REMODEL-FAMILY ROOM ADDITION.rupi Calc=MJ8 Front Door faces: S
+wrightsoft° Right-JO Worksheet .lob:
Entire House Date: Nov 06,2017
By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name Entire House MASTER BEDROOM
2 Exposed wall 92.0 ft 12.0 ft
3 Room height 9.0 ft d 9.0 ft heat/cool
4 Room dimensions 12.0 x 16.0 ft
5 Room area 1278.0 ft2 192.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number (Btuh/f?2-F) (Btuh/ft2) ;,or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-4ocs 0.143 n 4.00 2.55 324 212 850 541 108 78 312 199
4A5-2ob 0.560 n 15.68 16.16 82 0 1279 1318 0 0 0 0
_ 4A52om__--__-_-•-----0,770-.n- 21.58 19,31,.,----_30- --- 0 ___---647 ___---579 _-_ 30-__-- -__0 __-_647 ________579
W -- 13A-4ocs----- - - - -0.143_e-- - -4.00 --_2.55 .I ---I53- -- 153.. . __613-_._389-- - 0 0 - __-- --0
11 13A-0ocs 0.143 s 4.00 2.55 99 69 276 ' 176 0 0 0 0
__ . 4A5.2om-- -- -----0.770_s-_-21.56-_19:31-_a-_30---___60_. ___647 -----579.--- ____0-----0-----�.
Val 13A-4ocs 0.143 w 4.00 2.55 252 187 747 475 0 0 0 0
��CGI 10D-m 1.390 w 38.92 38.45 20 2 794 784 0 0 0 0
4A5-2om 0.770 w 21.56 45.10 45 6 970 2030 0 0 0 0
.P ..-_-j2G0sw_.__--_____-_ 0 091._ _ .____.2.155 1.28 i _306-._._-_306_--.._._780. 393_-- -_ 9 _0_ __0 - _..-_0
C --166 30ad_ -. _ 0 032 0 90 _- _1.68 II _ 9278 1278 1145-_ 2147__-_192 _-192 172_—_-323
0 989-__-_..27 69_. -0.00 i_- 1278 --._92 _--__2548 __`0_---192_ _-__12_!__332_ 0
- -- ------ ---- ------- ---------- ---- ------
__---------
6 c)AED excursion 688 -30
Envelope loss/gain 11296 10097 1463 1070
12 a) Infiltration 2655 727 346 95
b) Room ventilation 0 0 0 0
13 Intemal gains: Occupants @ 230 4 920 2 460
Appliances/other 2000 0
Subtotal(lines 6 to 13) 13951 13744 1810 1625
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 13951 13744 1810 1625
15 Duct loads 33% 51% 4839 6966 33% 51% 602 824
Total room load 18590 20710 2411 2449
Air required(cfm) 1 980 980 1 127 116
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoft' 2018-Mar-15 15:16:24
�� Right-Suite®Universal 2017 17.0.14 RSU08101..ments\VERDONCK REMODEL-FAMILY ROOM ADDITION.rup Calc=MJ8 Front Door faces: S Page 1
wrightsoft° Right-J®Worksheet Job:
Entire House Date: Nov 06,2017
By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name M.BATH WIC
2 Exposed wall 17.0 ft 6.0 ft
3 Room height 9.0 ft heat/cool 9.0 ft heat/cool
4 Room dimensions 1.0 x 54.0 ft 5.0 x 6.0 ft
5 Room area 54.0 ft2 30.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number (Btuh/Wz*F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool ;Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-4ocs 0.143 n 4.00 2.55 45 45 180 115 0 0 0, 0
I-� 4A5-2ob 0.560 n 15.68 16.16 ':, 0 0, 0 0 0 0 0 0
_ 4A5-2om.---- ---0.770 .-n-- ----21.56 -19.31- ----0 --------0- ---0 - 0-- -- - -.0-- ---0 ----
W - - 13A-4ocs------ -0.143 --e - 4.-.Op - 2.55 +--_99-_._---99 --396 ---252 - -54- ----� -- 216 . -- 137
11 U(J 13A-flocs 0 0
_----G-4A5 2om.__..._ 0 770--s•----21.56_ 19.31 _� 0 ----0- -- -0-- - --0 --=--0 -----0•----0 ---Q
13A-4ocs 0.143 w 4.00 2.55 9 9 36 23 0 0 0 0
10D-m 1390 w 38.92 38.45 0 0 0 0 0 0 0 0
--_-_ _ 4A5-2om ___--_-- 0.770_w_ 21.56 45.10,_i--0-- -0
P_- 12C Osv✓- — -- -- -0 091 _ 2:--_. 1.28_t ---jQ --0 0
C 16B-30ad 0.032 - 0.90 1.68 54 54 48 91 30 30 27 50
,22A-tpl. _ 0 9$9 _._ ,.-27.69 -Q.OQ ._-.54.
6 c)AED excursion -11 -4
Envelope loss/gain 1132 469 409 184
12 a) Infiltration 491 134 173 47
b) Room ventilation 0 0 0 0
13 Intemal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 1622 603 582 231
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1622 603 582 231
151 Duct loads 33% 51% 539 306 33% 51% 194 117
Total room load 2162 909 776 348
Air required(cfm) 114 43 41 16
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
c "�" wrigFrttsoftm 2018-Mar-15 15:16:24
Right-Suite®Universal 2017 17.0.14 RSU08101 Page 2
'��` ...ments\VERDONCK REMODEL-FAMILY ROOM ADD IT]ON.rup Calc=MJ8 Front Door faces: S
i
wrightsoft, Right-M Worksheet Job:
Entire House Date: Nov 06,2017
By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name KITCHEN/DINING BEDROOM 2
2 Exposed wall 0 ft 11.0 ft
3 Room height 9.0 ft heat/cool 9.0 ft heat/cool
4 Room dimensions 1.0 x 412.0 ft 12.0 x 11.0 ft
5 Room area 412.0 ftz 132.0 ftZ
Ty Construction U-value Or HTM Area (W) Load Area (ft� Load
number (Btuh/ftf-°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 1�- - 13A-4ocs 0143 n - 4.00 2.55 0 -__o ._----0 _0 _ 0 0 0 0
-G 4A5-2ob 0,560 n 15.68 16.16 0 0 0 0 0 0 0 0
'-_C:AA5-2om_ __- _-0-770--n _.._21,56 19.31: _---__0..-_--.._0. _--0-.___.-0_.___ -� -------0.-_ --_0 -0
w 13A-4ocs ____ ___0.143 e_ _ 4.00 2.55 0 0 0 __0 _ 0 0 0 0
11 VN 13A-flocs - 0143 s --4.00 2.65 i 0 0 0 0 0 0 0 0
4A52om.-,_-._.-- . 0770.-s_. - 21.56__-19.31 1 Q_._.__,.0. _-_ -0 _0-_.. -0-----0.-.___0
VL 13A-4ocs 0.143 w 4.06 2.55 0 0 0 0 99 84 336 214
10D-m 1.390 w 38.92 38.45 0 0 0 0 0 0 0 0
4A5-2om_ 0.770 w_ 21,56 45.10 0 - 0 0_ 0_ 15_-_ 1 323_____ 677
_ --2-
_ _ - --_ _ _ -. _-- - .._ -__..w_... -- __--. __ __., __ __ ____._ ____ _
P _-_ 12C-0sw___-__- _ ___0 091 -___ --_2.55--_1.28 -,-_ 63_ -63 161 - _ -81._ _--_27 27 _69-_---35
C 16B-30ad 0.032 - 0.90 1.68 1 412 412 369 692 132 132 118 222
_ _ _ _ __ .. _ . - __- -- - _ _ _ __. -_
F 22A-tpl----------_-0 989_a___27.69__-0.00.._-_412 _. 0 -- -0__- _0 -- 132 --- 11 305--- -�
l
i
6 c)AED excursion -50 290
Envelope loss/gain 530 723 1151 1437
12 a) Infiltration 0 0 317 87
b) Room ventilation 0 0 0 0
13 1ntemal gains: Occupants @ 230 0 0 1 230
Appliances/other 2000 0
Subtotal(lines 6 to 13) 530 2723 1469 1754
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 530 2723 1469 1754
15 Duct loads 33% 51% 176 1380 33% 51% 488 889
Total room load 706 4103 1957 2643
Air required(cfm) 37 194 103 125
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoft' 2018-Mar-15 15:16:24
Right-Suite®Universal 2017 17.0.14 RSU08101 Page 3
'C�` ...ments\VERDONCK REMODEL-FAMILY ROOM ADDITION.rup Calc=MJ8 Front Door faces: S
-wrightsoft° Right-J®Worksheet Job:
Entire House Date: Nov 06,2017
By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name BATH 2 BEDROOM 3
2 Exposed wall 0 ft 11.0 ft
3 Room height 9.0 ft heat/cool 9.0 ft heat/cool
4 Room dimensions 9.0 x 5.0 ft 11.0 x 10.0 ft
5 Room area 45.0 ftz 110.0 ftz
Ty Construction U-value Or HTM Area (ftz Load Area (ftz) Load
number (Btuh/ft�°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat cool
6 --- 13A-4ocs- - -- -- 0.143 n -4.00 - 2.55 ( -0 ----0 -0- ----0-- ---0' - 0-- --0- ---0
%-G4A5-2ob 0.560 n 15.68 16.16 I 0 0 0 0 0 0 0 0
4A5-2om__--- ---'0.770._n_ 21.56_ 19:31. --0----------0. ------_A. -----0--__--0-------0------Q--------Q
W-_. 13A-4ocs- ------ 0.143. e - 4.00_v 2_55 -I- -- -0._-.. 0- - - 0- - - 0--- ---0 --- -0------8 ------0
11 V1��J,r 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 99 69 276 176
�G._4A52om _--_--- 0:770_s_ -21.56_--19.31___L____ 0__._._0'---____.0 ___- 0-----_30 ----_30
13AAocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0
10D-m 1390 w 38.92 38.45 0 0 0 0 0 0 0 0
4A5-2om _ -`_0.770 w-, 21.56-_45.10- ----0 _.0_ 0..__ _-0 _ 0._ ---0_ __0--_ _-0
__0 091 -- _ - 2._55 - -1.28 126 ___126 _ _321
C_ 16B_30ad 0.032. 0. - 1.68 - 45 45 - 40 76 110 110 _99,_ -185
F__.__., 22A
I
i
6 c)AED excursion -4 -25
Envelope loss/gain 361 233 1556 1030
12 a) Infiltration 0 0 317 87
b) Room ventilation 0 01 0 0
13 Intemal gains: Occupants @ 230 0 0 1 230
Appliances/other 0 0
Subtotal(lines 6 to 13) 361 233 1873 1347
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 361 233 1873 1347
15 Ductloads 33% 51% 120 118 33% 51% 623 683
Total room load 482 351 2496 2030
Air required(cfm) 25 17 132 96
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
Ak wrightsoft' 2018-Mar-15 15:16:24
Right-Suite®Universal 2017 17.0.14 RSU08101 Page 4
'4CC,k ...ments\VERDONCK REMODEL-FAMILY ROOM ADDITION.rup Calc=MJ8 Front Door faces: S
wrightsoft° Right-M Worksheet - Job:
Entire House Date: Nov 06,2017
By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@40L.COM
1 Room name FAMILY ROOM
2 Exposed wall 35.0 ft
3 Room height 9.0 ft heaticool
4 Room dimensions 1.0 x 303.0 ft
5 Room area 303.0 ftz
Ty Construction U-value Or HTM Area (ft� Load Area Load
number (Btuh/W°F) (Btuh/ft� 'or perimeter (ft) (Btuh) or perimeter
Heat Cool (Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-4ocs--- --0.143 n 4.00 2.55 171 7 89 358 228 - w- - --
4A5.2ob -- 0.560 n 15.68 16.16 82 0 1219 1318
--.4A5-2om------—0.770-n-- -21.56 19.31._!---=0--------0----_0 ---0.
w 13A-4ocs_ 0.143 -_e 4.00 2.55 0 0 0 0
11 WJ--- 13A-4ocs _-- 0.143 s� 4.00 - 2.55 - 0 _._. _ -0- O- -O
--4A5720m--�- - 0 770-s_—21.56--19:31. , ---0----Q -- _0- - 0 _ - --- --- -----.�_-
13A-4ocs 0.143 w 4.00 2.55 144 94 375 238
10D-m 1.390 w 38.92 38.45 20 1 794 784
,4A5-2om_------_0.770 w 21.56--45.10 30 2 647_--1353
P 12GOsw — -__- 0 091.__ ---2.55•-- 1.2$_,_ . 0; _-_ 0-- ___0. —___...-0 _--
C_ 166_30ad _ 303 303- 271-
F 226 tpl _ 0 989 _ 27 69
6 c)AED excursion 520
Envelope loss/gain 4694 4951
12 a) Infiltration 1010 277
b) Room ventilation 0 0
13 Intemal gains: Occupants @ 230 0 0
Appliances/other 0
Subtotal(lines 6 to 13) 5704 5228
Less external load 0 0
Less transfer 0 0
Redistribution 0 0
14 Subtotal 5704 5228
15 Duct loads 33% 51% 1897 2650
Total room load 7600 7877
Air required(cfm) 401 373
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoft" 2018-Mar-15 15:16:24
Aft Page Universal 2017 17.0.14 RSU08101 Page 5
..mentsWERDONCK REMODEL-FAMILY ROOM ADD ITI ON.rup Calc=MJB Front Door faces: S
Dt System Summary Date: Nov 06,2017
Entire House By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772 466-6796 Email:QUICKCALCS@,AOL.COM
I
Project • •
For: VERDONCK RESIDENCE
267 BERMUDA BEACH DRIVE, FT. PIERCE,FL
I Heating Cooling
External static pressure 0.50 in H2O 0.50 in H2O
Pressure losses 0 in H2O 0 in H2O
Available static pressure 0.50 in H2O 0.50 in H2O
Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O
Lowest friction rate 0.327 in/100ft 0.327 in/100ft
Actual air flow 980 cfm 980 cfm
Total effective length (TEL) 153 ft
Supply Branch Detail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv
Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk
BATH 2 h 482 25 17 0.667 4.0 Ox 0 VIFx 5.0 70.0
BEDROOM 2 c 2643 103 125 0.413 7.0 OxO VIFx 31.1 90.0 st1
BEDROOM 3 h 2496 132 96 0.594 7.0 OxO VIFx 14.1 70.0
FAMILY ROOM h 3800 200 186 0.327 8.0 OxO VIFx 42.8 110.0 st2
FAMILY ROOM-A h 3800 200 186 0.390 8.0 OxO VIFx 38.2 90.0 st1
KITCHEN/DINING c 2051 19 97 0.455 7.0 Ox0 VIFx 20.0 90.0 st1
KITCHEN/DINING-A c 2051 19 97 0.424 7.0 OXO VIFx 28.0 90.0 st1
M.BATH h 2162 114 43 0.342 6.0 Ox0 VIFx 36.4 110.0 st2
MASTER BEDROOM h 2411 127 116 0.351 8.0 Ox0 VIFx 32.3 110.0 st2
wlc h 776 41 16 1 0.344 4.0 OxO VIFx 1 35.3 1 110.0 st2
i
SupplyDetail Table
I
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk
st2 Peak AVF 482 362 0.327' 614 12.0 0 x 0 VinlFlx st1
st1 Peak AVF 823 867 0.327' 1104 12.0 0 x 0 VinlFlx
.► �"' wrightsoft 2018-Mar-15 15:16:25 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1
ACCA ...mentsWERDONCK REMODEL-FAMILY ROOM ADDITION.rup Calc=MJ8 Front Door faces: S
I
TableReturn Branch Detail
Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk
rbl Ox0 980 980 0 i0 0 0 Ox 0 VIFx
I
i
wri htsoftW 2018-Mar-1515:16:25
ti 9 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 2
ACCA ...mentsWERDONCK REMODEL-FAMILY ROOM ADD ITION.rup Calc=MJ8 Front Doorfaces: S