HomeMy WebLinkAboutBUILDING PLANPlanning & Development Services Department
4 1 Building & Code Regulations Division
R111-
2300 Virginia Avenue, Fort Pierce, FL 34982 -(772) 462-1553
Certification for Design Load Compliance
Project Name: VERDONKADDITION
_Project Address: 267 BERMUDA BEACH DR.
Permit#: Occupancy Type: R Construction Type: V
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the If above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
L DESIGN CODE: Florida _Building Code 2017 Edition with 20 `Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _ Partially Enclosed Open
3. Risk Category: _ 1 X II III_ IV Exposure Category: _ B C X D
4. Design Wind Velocity 165 mph 128 ASD N/A LRFD End Zone Width: 5 ft
S. Mean Roof Height: 16 it Roof Pitch: o.s 12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: 17.6 Zone 2: 17.6 Zone 3: 17.6 Zone 4: 43.3 Zone 5: 43.3 Garage: N/A
43.3 72.7 109.4 -47.0 -58.0 N/A
7. Design Loads: Floor: 40 PSF Roof/Dead: 5 PSF Roof/Live: 20 Balcony:. N/A PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PLF / CONCENTRATED
8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? _Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
Planning & Development Services Department
• Building & Regulations Division
Product Review Affidavit
Building Permit # Owners Name Applicant:
Product
Opening Design
Product Rated
Manufacturer
Model Number
Product Approval
Glass
Method of Attachment
Pressures
Desi n Pressure
Number
7 e
-
Windows
foarm 1,
rt>ae� -�o
PG-T
Olt 5'S�
ro 2-39. 7
3�1�w �t ��e" � xN rau�tru�J'`®p
Mullions
yes- ELI ,
4/,00,/0
f coor
iyl,75
FG# L(Al - I
N181
�-
5flre". lsr$'",M' P
Fixed Glass
M) A
'
Block Glass
Skylights
SlidingBlass Doors
'�� CLF,s 't
4-/- (Qo
I'fi T
/ **f1
7�f O T40
F'LAL 251,4
THIP4-T
�x tga'^ "I sFe .g�.A Taa��naS
Swing Type Doors
V
-"t/-'}�
�'/J�
FD-10)
V0.4,9157-e :0)
M$GLi
'/4' �a�F CN C.o at'
NS7.at. AYT
French Doors
N
Garage Doors
Hurricane Protection
Roof Ventilation
Roofing Material
-IQ9,
I25+b
CtillGlidJttl0
Moor
6!-f(Jo,/ u
Ala q 0
/7 D57-%0?
/"�,i
a r r�
bpr �moP1"TAG}{MeIJC �w PLAIJ
I have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the
wind loads and forces specified by current code provisions.
Name: PAUL WELCH P.E. Signature: ON PLAN
Design Prof,, PAUL WELCH P.E.I Cert. No. 29945 Date:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
ELECTRICAL NOTES
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
1)
ALL ELECTRICAL WORK SHAL BE IN ACCORDANCE WITH THE NEC (NFPA 70)
ELECTRICAL LOAD CARC'S2014
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
2)
EDITION.
A MINIMUM OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING
PER NEC
forces specified:
FIXTURES SHALL BE HIGH-EFFACY LAMPS OR A MINIMUM OF 75% OF THE
2176 S.F. @ 3 VA
6528 VA
Paul Welch P.E.
29945 / 5115
PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY
TWO 20A APPLIANCE CK' S
3000
HIGH-EFFACY LAMPS. (LOW VOLTAGE LIGHTING SHALL NOT BE REQUIRED
Print Name Cert It & Co. Cert Auth.
TO BE HIGH-EFFACY LAMPS)
LAUNDRY
1500
Paul Welch Inc.
3)
PROVIDE BRANCH CIRCUIT ARC -FAULT PROTECTION FOR ALL CIRCUITS
DRYER
5000
ON PLAN 3/7/2018
SERVING: FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS,
RANGE
12000
Signature, Date, and SealBRARIES,
g 1984 S.W.SVdSt. Suite #114 Port St.
Lucie, FL
DENS, BEDROOMS SUNROOMS, RECREATION ROOMS, CLOSETS,
WH
4500
HALLWAYS, OR SIMILAR ROOMS PER FBC AND NEC REQUIREMENTS.
DW
1200
Name
Company Name &Address
& d
Slccuv orm u u2u-iz Revised s/1s/iz IIs)
_ 4)
PROVIDE GROUND -FAULT CIRCUIT INTERRUPTER PROTECTION FOR ALL 125-
REFRIG(S)
2400
VOLT, SINGLE-PHASE 15 AND 20 AMP CIRCUITS SREVING: BATHROOMS,
IRR. PUMP (OPTION)
1800
GARAGES, KITCHENS, ACCESORY BUILDINGS, OUTDOORS, OR WITHIN 72" OF
MISC
10000
EDGE OF ANY SINK.
TOTAL
47928 VA
5)
PROVIDE TAMPER RESISTANT RECPTICLES PER NEC REQUIREMENTS.
6)
TIE ELECTRICAL INTO EXISTING ELECTRICAL SERVICE.
°
FIRST 10 KW @ 100 /°
10000
-
-.
-
- - - - --
REMAINDER A40%
15171.2
TOTAL
25171.2
APPLIED
DESIGN
PRESSURES
(PSF)
G_
MARK
I
E
AIC HEAT fad 100%
20000
ZONE
4
ZONE 5
(+)
(-)
(+)
(-)
TOTAL
45171.2 VA
1
10I
43.3
1 .47.0
43.3
-58.0
45171.2
2
15I
43.2
1 -46.9
43.2
-57.8
240 = 188 AMPS
3
20I
43.1
-46.8
43.1
-57.6
4
25'
43.0
-46.7
43.0
57.3
, .
USE 200 AMP SERVICE
5
30,
42.9
-46.6
42.9
-57.1
6
35
42.8
-46.4
42.8
-56.9
EAST FLEVATIGN SCALE /4
ROOF ATTACHMENT REQUIREMENTS
ROOF DATA:
Manufacturer:
CERTAINTEED
Type:
MODIFIED BITUMEN
NOA#:
14-0529.02
System Type:
E(3) Base sheet Mechanically fastened page 23 of 42
Design Pressure:
52.5 (-PSF) PER NOA
Membrane Type:
APP MODIFIED
Deck:
19/32 " Plywood
Base Sheet:
Weather / Empire Base Sheet
Fasteners:
I 1 ga. annular ring shank nails and approved tin caps
(spacing per base sheet attachment requirements)
BASE SHEET ATTACHMENT REQUIREMENTS:
ZONE 1:
Base sheet attached to deck with Fasteners as specified above
(Field)
at 8 " O.C. in ( 4 ) rows. One row is in the side lap. The otiv,- rows
are equally spaced approximately 9.8 " O.C. in the field of the s1Eet.
(METHOD PER NOA) Design Pressure (-PSF): 52.5
ZONE 2:
Base sheet attached to deck with Fasteners as specified above
(Perimeter/ Ridge)
at 5 " O.C. in ( 4 ) rows. One row is in the side lap. The otha rows
are equally spaced approximately 9.8 " O.C. in the field of the sleet,
(ENHANCED FASTENERS) Design Pressure (-PSF): 75.5
ZONE 3:
Base sheet attached to deck with Fasteners as specified above
(Comers)
at 3 " O.C. in ( 4 ) rows. One row is in the side lap. The othu rows
are equally spaced approximately 9.8 " O.C. in the field of the shet.
(ENHANCED FASTENERS) Design Pressure (-PSF): 125.8
MEMBRANE REQUIREMENTS:
One ply of Flintlast FR Cap 30 TCoolStar torch adhered to base sheet.
SURFACING
Any of the approved
surfacing options as per Table 4 of the Product Approval
DECK INSTALLATION:
Nail all plywood sheathing
(19/32" thick minimum) with 8D ring -shank nails at 4" O.C.
perimeter and N" O.C. field for all zones.
NOTE: REFER TO MANUFACTURER'S SPECIFICATIONS AND INSTALLATION
INSTRUCTIONS FOR ADDITIONAL INFORMATION AND REQUIREMENTS.
TA�Ul�ATLItlra
NEWI,IV1Nfa:
'�03 SLIT
EXIST, LIVING:
1813 SwFT
.EX15I..-GIARAUrc:
205 5QFT
K15Y- Gov..174R.G14:
10(n.5QFT
DOTAL: 2)4015151FT
...n 00-Ln
SCOPE OF WORK
CONSTRUCT ADDITION TO EXISTING RESIDENCE PER PLAN.
NOTES:
1)
THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ECT. SHALL VERIFY ALL
DIMENSIONS, CONDITIONS AT SOB SITE, PLANS, SPECIFICATIONS, ECT.
2)
STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE
ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES.
3)
ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER
SCALED DIMENSIONS.
4)
ALL CONSTRUCTION MUST COMPLY WITH THE FLORIDA BUILDING CODE
(FBC) 2017, FBC 2017 RESIDENTIAL, FBC 201 (PLUMBING CODE, FBC 2017
MECHANICAL CODE, FBC 2017 ENERGY CONSERVATION, AND THE NEC (NFPA
70) 2014 EDITION.
5)
RESIDENCE LOCATED IN NEGLIGIBLE WEATHERING AREA, AND IN VERY
HEAVY TERMITE INFESTATION AREA PER FRC 301.
6)
ALL ADDITIONS, REPAIRS, AND ALTERATIONS MUST COMPLY WITH THE F.B,C
2017 FOR EXISTING BUILDINGS.
R
STRUCTURAL NOTES
1)
DESIGN LOADS IN ACCORDANCE WITH ASCE7-10.
2)
SOIL BEARING CAPACITY: 2500 PSF (MIN.).
3)
ALL STRUCTURAL CONCRETE IN BEAMS, LINTELS, VERTICLE CELLS, AND
COLUMNS SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI
COMPRESSIVE STRENGTH AT 28 DAYS.
4)
SLAB / FOOTINGS TO BE CONCRETE WITH A MINIMUM 2500 PSI COMPRESSIVE
STRENGTH AT 28 DAYS. SEE PLAN FOR SIZES & STEEL REQUIREMENTS.
5)
MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
FOOTINGS: 3" BEAMS: 1'/z" SUSPENDED SLABS: 1 Y2"
6)
LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS EXCEPT AS
NOTED GRADE 60 STEEL MINIMUM IN BEAMS AND COLUMNS.
7)
ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED.
8)
SPLITING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO
INSTALATION OF HARDWARE IS NOT PERMITED,
9)
UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE
SHALL CONFORM TO THE MANUFACTURES INSTRUCTIONS AND STANDARD
PIRACTICIES.
10)
UNLESS OTHERWISE NOTED, ROOF SHEATHING TO BE NAILED WITH 8d RING -
SHANK NAILS AT 4" O.C. PERIMETER AND 6" O.C. FIELD.
11)
LINTELS SHALL HAVE A MINIMUM 4" BEARING EXCEPT RECESSED LINTELS
SHALL HAVE 8" BEARING.
12)
PROVIDE # 5 CORNER BARS W/ 30" MIN. LAP SPLICE FOR BOND BEAM.
LINTEL SCHEDULE
LINTEL #
LENGTH /TYPE
GRAVITY
LOAD
GRAVITY
LOAD
UPLIFT
LOAD
UPLIFT
LOAD
COMPOSITE
BEAM
L-1
5'-10" 70" U-LINTELS
2622
150
1492
150
8F12 1B-IT
L-2
T-6" 90" U-LINTELS
1729
150
1021
150
8F12 IB-IT
L-3
13'-4" 160" U-LINTELS
755
489
455
390
SF12 1B-2T
NOTE: WHEN LINTEL IS IN VARIOUS LOCATIONS, WORST CASE LOADING IS SHOWN
NOTE: PROVIDE "CASTCRETE" PRE -CAST CONCREE LINTEL AS NOTED ON PLANS,
d3 a
5TDAKTER(',Jt.
ex+�*. ELet49
x-- --T1 • o e
FAMILY ROOM
FAN I LT MDROOM
EXIST . ST. LIJCIE COUNTY BLTLDIN ON
�-?TAkTFIZCOL EX15i' Cr%?i ✓ REVIEWED FOR COMPL
REVIEWEq B ._.._ DATE y/l
_ _ _ _ _... -• PLANS AND PERMIT MUST KEPT ON JOB
OR NO LNSPECTION WILL MADE.
�EDIZ(?QM ♦' tee' Dl1�INr, c.!
CONCEALED FASTERAS ON ATTACHMEOS
ARETHERESPONSIBILITI'OF THE
CONTRACTOR OF MORD
ric r PLANS AND ALL PROPOSED WORK
AP SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
FLOW I/ 1 a MAY BE NECESSARY IN ORD
I ER TO L GTIz1 C/� �^� .A f�l GALE - 1 0011110wITMA"APOW0AALE00098.
RECETVEI� ---
FILE CO[
AR 1S,.
.. 5T_LuMcie Co
nrv.:^,
PAUL WELCH INC.
Alr'CHAN/CAL ELECTRICAL CIVIL ENGINEERING
I984 S. W B/LTMOREST, SUITE# I f4
PORTST, LUCIE, FL34984,
PHO)VEC772) 788-9888 E-MAIL PWELCHINCLaAOL CON
PAUL PVEL CH, P.E.. FLA REG NO. 29945
MAR 0 7 2018
L-3 r
i�
U
O
A
i
Q
�a
SHELT IlLNBER
R-30INSULATION - -
'/2" DRYWALL (CEILING) --
(I ROW)
S"XS" CONTINUOUS CONCRETE -- - ---
BEAM BLOCKW/ (1) - #5 BAR IN
(3000 PSI) CONC.. FILLED EACH CELL
8" PRECAS LINTEL W/ (1)-#5 BAR IN (3000 PSI) CONCRETE FILLED CELL
AT ALL DOOR AND WINDOW
OPENINGS (SEE LINTEL SCH. FOR
MORE INFORMATION) -
'A" DRYWALL (WALL) --^-
1X2 FURRING Q 16" OR 24" O.C.
FIFOIL INSULATION -'--•-�--"-
— EXISTING ROOFING / ROOD' SYSTEM
— METAL FLASHING
"SIMPSON" HTSM 16 WITH (4) —1/4" x I
TITEN AND (8) — 10d EACH JOIST
-
- 10.5
(— CUTBACK EXISTING TRUSS TAIL,
MAINTAIN FULL BEARING
I/2" DRYWALL OVER 1 x 2 FURRING
EXISTING CMU WALL
(2500 PSI) CONCRETE FOUNDATION PER
PLAN
WALL FINISH / INSULATION NOTES
1) INTERIOR TO BE IW' DRYWALL FINISH.
2) ALL INTERIOR GYPSUM BOARD TO BE MIN, I/," THICK WITH (13 GAGE,13/8"
LONG,19/64" HEAD; 0.098" DIAMETER, 1 V44" LONG, ANNULAR -RINGED; 5D
COOLER NAIL, 0.086" DIAMETER, 15/8" LONG, 15/64" HEAD; OR GYPSUM BOARD
NAIL, 0.086" DIAMETER, 1 5/8" LONG, 9132" HEAD) SPACED AT 7" O.C. FOR NAILS
AND 12" O.C. FOR SCREWS.
3) WALLS AT SHOWER TO BE TILE. PROVIDE CEMENT, FIBER -CEMENT OR GLASS
MAT GYPSUM BACKERS IN COMPLIANCE WITH ASTM C 1288, C 1325, C 1178, OR
C 1278 AND INSTALLED IN ACCORDANCE WITH MANUFACTURERS'
RECOMMENDATIONS AS BACKERS FOR WALL TILE IN TUB AND SHOWER
AREAS AND WALL PANELS IN SHOWER AREAS. (PER FRC 702.4.1 & FRC 702.4.2).
4) WALL AND CEILING FINISHES SHALL HAVE A SMOKE -DEVELOPED INDEX OF
NOT GREATER THAN 450.
5) WALL AND CEILING FINISHES SHALL HAVE A FLAME -SPREAD
CLASSIFICATION OF NOT GREATER THAN 200.
6) ALL EXPOSED INSULATION MATERIALS INSTALLED ON ATTIC FLOORS SHALL
HAVE A CRITICAL RADIANT FLUX NOT LESS THAN 0.12 WATT PER SQUARE
CENTIMETER. EXPOSED FOAM PLASTIC INSULATION MATERIALS EXPOSED TO
THE UNDERSIDE OF THE ROOF DECK OR ON THE ATTIC WALLS SHALL
COMPLY WITH SECTION FRC316.
7) PER FRC 702.2.1 ALL GYPSUM BOARD MATERIALS AND ACCESSORIES SHALL
CONFORM TO ASTM C 36, C 79, C 475, C 514, C 630, C 931, C 960, C 1002, C 1047, C
1177, C 1178, C 1278, C 1395, C 1396 OR C 1658 AND SHALL BE INSTALLED IN
ACCORDANCE WITH THE PROVISIONS OF FRC, AND ADHESIVES FOR THE
INSTALLATION OF GYPSUM BOARD SHALL CONFORM TO ASTM C 557
8) INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR RETARDERS
OR VAPOR PERMEABLE MEMBRANES INSTALLED WITHIN FLOOR -CEILING
ASSEMBLIES, ROOF -CEILING ASSEMBLIES, WALL ASSEMBLIES, CRAWL
SPACES AND ATTICS SHALL HAVE A FLAME SPREAD INDEX NOT TO EXCEED 25
WITH AN ACCOMPANYING SMOKE -DEVELOPED INDEX NOT TO EXCEED 450
WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
ENERGY CONSERVATION NOTES
1) RESIDENCE SHALL BE IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017
ENERGY CONSERVATION RESIDENTIAL.
2) ATTIC ACCESS DOORS OR HATCHES FROM CONDITIOND SPACES TO
UNCONDITIONED SPACES SHALL BE WEATHERSTRIPPED AND INSULATED TO
A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES,
A WOOD FRAMED OR EQUIVALENT BAFFLE OR RETAINER IS REQUIRED TO BE
PROVIDED WHEN LOOSE FILL IS INSTALLED, TO PREVENT LOOSE FILL FROM
SPILLING INTO THE LIVING SPACE.
3) THE BUILDING THERMAL ENVELOPE SHALL BE CONSTRUCTED TO.LIMIT AIR
LEAKAGE IN ACCORDANCE WITH THE REQUIREMENTS R402AI THROUGH
R402.4.4.
4) THE BUILDING SHALL BE TESTED FOR AIR LEAKAGE IN ACCORDANCE WITH
R402.4.1.2
5) WINDOWS, SKYLIGHTS, AND SLIDING GLASS DOORS SHALL HAVE AN AIR
INFILTRATION RATE OF NO MORE THAN 0.3 CFM PER SQUARE FT, AND
SWINGING DOORS NO MORE THAN 0.5 CFM PER SQUARE FT AND MUST BE
TESTED LISTED AND LABELED IN ACCORDANCE WITH R402.4L3,
12
14
EXISTING CONCRETE FOUNDATION---
_
TORH DOWN ROOFING OVER
BASE SHEET PER PRODUCT
APPROVAL REQUIREMENTS
OVER 19/32" CDX PLYWOOD
ROOF SHEATHING WITH Sd
RINGSHANK NAILS AT 4" O.C.
PERIMETER AND 6" O.C.FIELD
--- 2X12 WOOD JOIST AT 16" O.C.
SIMPSON BETA20 WITH (9)-10d
* X 1'F," AT 24" O.C.
ALUM. DRIP EDGE
r 1 X 2 P.T. WD. DRIP EDGE OVER
2X12 P.T WD. FASCIA
---- #5 REBAR W/ 90 DEGREE HOOK
8"X8"X16" CONCRETE BLOCK
(MASONRY)
— #5 VERT. REBAR IN (3000 PSI)
CONCRETE FILLED CELL
(SEE PLAN FOR LOCATIONS)
/ L _V STUCCO FINISH
#5 REBAR W/ 30" MIN. LAP
SPLICE
FINISHED GRADE
(2500 PSI) CONC. FOUNDATION
SEE PLAN FOR SIZES AND
SPECIFICATIONS
=rn- na +ai
u
till=lU'�(Ij-n!
z
TORN DOWN ROOFING OVER
/ BASE SHEET PER PRODUCT
APPROVAL REQUIREMENTS
OVER 19/32" CDX PLYWOOD
ROOF SHEATHING WITH 8d
12 RINGSHANK NAILS AT 4" O.C.
0.5 PERIMETER AND 6" O.C:FIELD
' — 2X12 WOOD JOIST AT 16" O.C.
'--- SIlNPSON HETA20 WITH (9)- lod
- — - . X 1 X" EACH JOIST
ALUM. DRIP EDGE
R-30 INSULATION -- —•- a — I X 2 P.T. WD. DRIP EDGE OVER
2X12 P.T WD. FASCIA
Y," DRYWALL (CEILING)
(1 ROW)
STUCCO SOFFIT PER 8"X8" CONTINUOUS CONCRETE ----"-
� STRUCTURAL NOTES
BEAM BLOCKW/ (1) - #5 BAR IN — #5 REBAR W/ 90 DEGREE HOOK
(3000 PSI) CONC. FELLED EACH CELL
— 8"X8"X16" CONCRETE BLOCK
8" PRECAS LINTEL W/ (1)-#5 BAR — - (MASONRY)
IN (3000 PSI) CONCRETE FILLED CELL _
AT ALL DOOR AND WINDOW — — #5 VERT. REBAR IN (3000 PSI)
OPENINGS (SEE LINTEL SCH. FOR CONCRETE FILLED CELL
MORE INFORMATION) _ - (SEE PLAN FOR LOCATIONS)
'F4" DRYWALL (WALL) - - --- STUCCO FINISH
1X2 FIRRING aQ 16" OR 24" O.C. •---
-- #5 REBAR W/ 30" MIN. LAP
F1.FOIL INSULATION - ''x-•---------------• ----^- - SPLICE
- - - I — FINISHED GRADE
!!I-11J..,ll !p-,I1Ic".E`m nI_nl=+s-T—.(2500PSI) CONC. FOUNDATION
SEE PLAN FOR SIZES AND
lip, SPECIFICATIONS
TYFILA_I... Alt, E_ TlD_N
-- 7--
�
AND
FOUNDATION SCHEDULE
EAF �( 1ST
r`
I N
F-1 18" DEEP X I6" WIDE (2500 PSI) CONCRETE MONOLITHC.
/
`^'
FOOTING W/ (2). N5 BARS CONTINUOUS
J
-2 S" DEEP X 8" WIDE (25M PSQ CONCRETE MONOLITHIC
FOOTING W/(1).#5 BARS CoNTINuous
Sd 4" TEK (2500 PSI) CONCRETE SLAB W/ FIBERMESH
OR 6"/ 6" 10/10 W WM OVER VAPOR BARRIER ON
CL
CLEAN COMPACTED CHEMICALLY TREATED FILL
LL
5 q
B-1 #5 BARS X 12" LONG DRILLED OUT & EPDXIED
WITH 6" MINIMUM EMBEDMENT @ 24" O.C.
'I.
ALL AREAS ADJACENT TO EXISTING FOUNDATION
CONCRETE FOUNDATION NOTES
1)SLAB / FOOTINGS TO BE CONCRETE WITH A MINIMUM 2500 PSI COMPRESSIVE
STRENGTH AT 28 DAYS, SEE PLAN FOR SIZES &STEEL REQUIREMENTS
2)MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: FOOTINGS: Y'
SUBGRADE PREPERATION NOTES
1) THE AREA WITHIN TIM LIMITS OF THE FOUNDATION SHALL HAVE ALL
L^ L�
1//µ/'( -
— -
I
VEGETATION. TOP SOIL AND FOREIGN MATERIAL REMOVED.
2) CLE FILL SANDPLAOR GRAVEL
5 GA L F_
'
MUST BE CED TO DESIGN ISUBGRADE OF FREEVEGETATION AND FOREIGN
MATEEL
COMPACTED TO
ASSURE UNIFORM SUPPORT OF THE FLOOR SLAB. ,
3) SUBGRADE COMPACTION SHALL BE ACHIEVED BY MEANS AND METHODS
DETERMINED BY THE RESPONSIBLE CONTRACTOR. SOIL DENSITY TESTINO BY
INDEPENDENT SOILS TESTING FIRM SHALL BE REQUIRED TO INSURE PRESCRIBED
SOIL DENSITIES ARE ACHIEVED.
4) AFTER FOOTING EXCAVATION, AND FORMING, CONTRACTOR SHALL RECOMPACT
SUBGRADE SOILS USING SUITABLE VIBRATORY MECHANICAL COMPACTOR. THE
UPPER 16 INCHES OF SOILS UNDERLAYING THE WALL FOOTINGS SHOULD HAVE A
MINIMUM DENSITY OF 95%OF TIM MAXIMUM DRY UNIT DENSITY AS DETERMINED
BY MODIFIED PROCTOR METHOD FOR THE EXISTING SOILS. IN:FEACE SOIL DENSITY
TESTS SHOULD BE PERFORMED IN ACCORDANCE WITH ASTM 134922, AT A
FREQUENCY DETERMINED BY THE SOIL TECHNICIAN TO VERIFY VNIFORNI TY OF
THE UNDERLYING SOIL DENSITY, PRIOR TO PLACING CONCRETE,
5) SUBBASE COMPACTION FOR THE FLOOR SLAB FILL MATERIAL SHALL BE
UNIFORMLY COMPACTED TO A MINIMUM DENSITY EQUAL TO 984 OF THE
MAXIMUM DRY UNIT DENSITY OF THE FILL AS DETERMINED BY MODIFIED PROCTOR
METHOD IN ACCORDANCE WITH ASTM D-1551.
6) CONCRETE SLABS ON GRADE SHALL BE PLACED OVER A POLYETHYLENE VAPOR
BARRIER WITH A MINIMUM THICKNESS OF 6 MILLS, INSTALLED WITH LAPPED
JOINTS NOT LESS THAN 6INCHES AND CONTINUOUSLY TAPPED WITH HIGH DENSITY
POLYETHYLENE ADHESIVE TAPE.
4 19'-4"
FOUNDATION PLAN 5GALEY"
PAUL WELCH INC.
_— -- - - MECHANICAL ELECTRICAL CIVIL ENGINEERING
f984T S. W. B/LTMOREST, SUITE,# I f4
PORTST. LUC/E, FL 34984,
PHONE (7,72) 785 - 9888 E-MAIL EWELCH/NC@AOL COIN
PAUL WELCH, P.E,. FLA REG NO.299445
rw�
U
a
0
i
H
U
W
a
a
u
r
SHEET NUMBER
2
a
STUCCO CEMENT FINISH
FILLED CELL AT JAMB BLOCK (TYP)
CMU WATER RESISTANT COATING;
i
(SEE WATERPROOFING NOTE .#1,)
EXISTING CMU WALL
e
#5 HORZ. REBAR X 12" LONG
°
4 ;a
Iz3 P.T. WOOD FIRRING ALL (3) SIDES CONTINUOUS ."
a
-
DRILLED OUT AND EPDXIED TO
EXISTING WALL WITH 6"
WOOD TRIM
EMBEDMENT SPACED AT 6" FROM
TOP ARID BOTTOM AND 24" O.C.
VERT.
P. T. WOOD BUCK WITH SEALANT PER WATERPROOFING
APPLY PERIMETER SEALANT CAULK
NOTE #4 AND ANCHORED.TO MASONRY PER BUCK
#5 VERT. REBARIN (3000 PSI)
BETWEEN BUCK & WINDOW FRAME
ATTACHMENT, NOTE:
CONCRETE FILLED CELL
(SEE WATERPROOFING NOTE #5)
EJE
III
.
MF
SEE WATERPROOFING NOTE #6
CORROSION RESISTANT FLASHING
EXISTING FILLED CELL
„ - TER WATERPROOFING NOTE #2
ANCHOR DOOR ,.IAMB AND HEADER TO 2k' BUCKS IN
STRICT ACCORDANCE WITH MANUFACTURE'S
EXISTING WALL
NEW WALL
PRQDUC T APPROVAL INSTALLA 110N REQUIREMENTS.
STARTER COLUMN DETAIL ots...
SLIDING GLASS
DOOR, BUCK.
DETAIL
(PLAN VIEW)
_ --- ..
SCALE: N.I.S.
—
_
COIJTINUOIIS'F'UAf9 INTERIOR.'AIR7
FASTENERS
AS REQUIRED BY WINDOW MANUFACTURER
ST'UCCT1 CEMENT FIIJI5fI
_
AND WATER SEALANT PER,:. ..
WATERPROOFING NOTE �j6
r=-CORROSION
RESISTANT ,FLASHING PEP, WATERPROOFING'
_
NOTE #2
y
,,,--FILLED
CELL AT JAMB BLOCK (TYP)
MARBLE SILL
CAULK SEAM AT WINDOW INSTALLATION
CMU WATER RESISTANT COATING
NOTE'#1)
(SEE WATERPROOFING
NOTE #5)
(SEE WATERPROOFING
°. .°.
MORTAR OR
;.
CMU .WATER
RESISTANT COATING
GROUT
a
(SEE WATERPROOFING NOTE #I)
-
3i
n.l
P.T: WOOD FIRI�II�10 ALL (.a) SIDES
SET SII::L IN
FULL MORTAR BED
� °•
�-•---1x:.3
.°
CONTINUOUS
''
I
7z DRYWALL
"
STUCCO OR
DECORATIVE CEIvIEPJTITIOUS COATING
WOOD TRIM
8" C .IJ,.
.M.
CORROSION RESISTANT FLASHING
z
~
PER WATERPROOFING NOTE #2.
F'•'T. WOOD DUCK WITH SEALANT PER
3/A" FURRING
TO MASONRY WALL
WATERPROOFING NOTE #4. AND ANCHORED TO
MASONRY PER BUCK ATTACHMENT NOTE.
APPLY PERIMETER SEALANT CAULK
41,,
NETWEf N BUCK & WINDOW FRAME
\_--
SEE WATERPROOFING NOTE #6
"r
(SEE WATERPROOFING NOTE #5)
M
AND JAMB HEADERIN
__4
STRICOTRACCORDANCE WITHDOOR
MANUFACTURE'S
er
;
M�
PRECAST CONCRETE WIND RESISTANTFLUSFI
PRODUCT APPROVAI INSTALLATION REQUIREMENTS
SILT... AS MANUFACTURERD BY CAST—CRETE
(OR EQUAL)
EXTERIOR DOOR
BUCK..
DETAIi!
_;'RECAST CONCRETE WINDOW SILL_ DETAIL.
—
-- SCALE: N.T.S.
-- SCALE: N.T.S.------
WATERPROOFING NOTE-
11
. PRIOR TO BUCK INST'ALLAl10N TREAT THE MASONRY OPENING WITH A CMU WATER RESISTANT COATING '10
SEAL THE .WINDOW / DOOR CAVITY TO PREVENT 11 FROM ABSORBING WATER, THE CMIJ WATER RESISTANT
COATING SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. THE
3TUCC0. CEMENT FINISH
`'
APPLICATION OF THE CMU WATER RESITANT COATINGSHALL INCLINE THE ENTIRE SURROUND OF THE
y
CVENING (SILLS, JAMBS, HEAD) AND RETURN WALLS OF THE OPENING 8" MINIMUM EACH DIRECTION. ALL
J
,,,--FILLED CELL AT JAMB BLOCK (TYP)
CMU WATER RESISTANT' COATINGS SHALT. BE INSTALLED PRIOR TO BUCK INSTAI._LATIONS,
CMU WATER RESISTANT COATING
.
2.,
INSTALL BUCKS SD THAT THERE ARE NO EDGE GAPS EXCEEDING 1/B" BETWEEN BUCK AND MASONRY.
(SEE WATERPROOFING NOTE #1)
3.
PRIOR TO BUCK INSTALLATION APPLY :3/8- NOMINAL. DIAMETER BEAD. OF SEAL.AfII BETWEEN THE BUCK AND
THE MASONRY TO PREVENT THE PASSAGE OF LIQUID BEHIND THE BUCK. COMPLETELY SEAL THE ENTIRE.
CORROSION RESISTANT FLASH ING
° B'
-THE OF 11-IE' WOOD BUCKS WITH SEALANT TO RESTRICT 'THE PASSAGE 01- LIQUID 'Tl-IROLIGI-I IHE'Clll-, ENDS
PER WA1'ERPROO(-1NG
NOTE #2
w
°':o °
_
I-- ix3 P.T. WOOD FIRRING ALL (3) SIDES CONTINUOUS` '
AND THE ENTIRE EXTERIOR FACE AND RETURN SURFACE OF THE BUCK SHALL. BE COATED WITH A 1_1001D
.°
-
APPLIED .WATER RESISTIVE COATING / SEALANT.
•�
!
-�
A.
PROVIDE -r S.
F'Ft VID_ PALM FLASHING ING T I O AND D00 OPENINGS. FLASHING SHALL BE
Ali A SILL F WINDOW A R P NIN PAIN FI_A_HI JG I SEALED OR
APPLY 1'ERIMETEF
SEALANT CA111<
O
SEE WATER PROOFING NOTE #6
SLOPED IN A MANNER TO DIRECT,WATER WATTER '10 THE SURFACE OF 111E EXTERIOR WATER RESISTIVE BARRIER FOR
BETWEEN BUCK
& WINDOW MANE
SUBSEQUENT DRAINAGE. INCORPORATE PAN FLASHING AT HEAD AND SILT_ AS WELL FAIN FLASHING SHALL_
(SEE WATERPROOFING NOTE #5)
�
BE CORROSION RESISTANT (OPTIONAL NOT REQUIRED IF ITEM #1=3 INSTALLED),
— P.T. WOOD BUCK WI Ill SEALANT PER
WAlETRP1300FI14G NOTE #4 AND .ANCHORED TO.
5.
PROVIDE CONTINUOUS 3/8" BEAD OF SEALANT ON WINDOW / DOOR FRAMES AT' ALL PERIMETER ON FRONT
MASONRY PER BUCK ATTACHMENT NOTE.
AND BACK SURFACE PRIOR TO WINDOW./ DOOR INSTALLATION,
\
�
6.
.AFTER WINDOW/..DOOR INSTALLATION PROVIDE FOAM SEALANT BETWEEN THE BUCK (OR PRECAST SILT...) AND .
NOTE:
ANCHOR WINDOW FRAME TO MASONRY IN STRICT
THE WINDOW
/ DOOR TO ENSURE A WATER RESISTAIJT INTERIOR AIR SEAL AROUND TITS ENTIRE PERIMETER:
WINDOW FRAME SHOULD BE COMPLETLY
SEATED
ACCORDANCE WI-1-1-1 MANUFk TURE'S PRODUCT
ON THE BUCK. IN NO INST/NCE SHALL TFIE APPROVAL. INSTALLATION REQUIREMENTS_
FRAME OVERHANG THE BUC<
_WINDOW HEADER AND JAMBS TYP. BUCK DETAIL:
SCALE:. N.T.S.
NOTE:
WINDOW
AND DOOR FENESTRITIONS
SHALL BE IN
ACCORDANCE WITH FMMA /. AMA 200-9• CONTRACTOR
SHALL SUBMIT FMMA / AMA 200-9
STANDARDS
WITH PERMIT SUBMITTAL.
BUCKS:
• FOR
WINDOWS, SGD, AND SWING
DOORS USE
2X4, 2X6,.2X8, 1X6, 1X8, DOUBLE 1X6, OR DOUBLE 1X8 IS
ACCEPTABLE.
ALL
BUCKS MUST BE PRESSURE
TREATED.
ALL
BUCKS MUST COVER ENTIRE
DEPTH OF THE
DOOR/WINDOW JAMB;
B=—ATTACHMENT:
• FOR 1 X BUCKS ATTACH TO CMU WAL WITH'
1 1/2" LONG CASE HARDENED COIL NAILS AT 4" FROM ENDS AND
12" O.C.
OR
3/16" X 1 1/2" TAPCONS AT 4" FROM ENDS AND 12" O.C.
OR
1/4" X 1. 1/2" TAPCONS AT 4" FROM ENDS AND 12" O.C.
• FOR 2 X BUCKS ATTACH TO CMU WALL WITH'_
2 1/4" LONG.CASE HARDENED COIL NAILS AT 4" FROM ENDS AND
12" U.C.,
OR
3/16" X 2 1/4" TAPCDNS AT 4" FROM ENDS AND 12". D.C.
OR
1/4" X 2 1/4". TAPCONS AT 4" FROM ENDS AND 12" O.C.
FOR DOUBLE 1 X BUCKS ATTACH FIRST C)URS TO CMU WALL Wfflt
1 '1/2" LONG CASE HARDENED COIL NAILS AT 4" FROM ENDS AND
12" O.C:
OR
3/16" X:1 1/2" TAPCONS AT 4" FROM ENDS AND 12" O.C.
OR
1%4" X 1 1/2" TAPCONS AT 4' FROM ENDS AND 12" D.C. ATTACH
SECOND LOURS 10 CMLJ WALL TIIRLI
FIRST COURSE WITH: 2 1/4" LONG CASE HARDENED COIL NAILS AT
4" FROM ENDS AND '12" O.C.
OR
:3/16"_X 2 1/4" TAPCONS AT 4-" FROM ENDS AND 12" D.C.
OR
1/4" X 2 'I/4" TAPCO14S AT 4" FROM ENDS AND 12" O.C.
PAUL WELCHING _
MECHANICAL ELECTRICAL CIV%L ENGjNEERING
f984S. W. BILTMORES'T- SUITE & f f4
PORT57: L.UCIE, FL,34984_
j PI-JONE(77,2)785-9888 EMAIL PKIELGHINC@AOL:GOM
PAUL, YVELCH, P.E. FLA REa1V0.29945
MAR U 1 flila '
W
E-a
1�$
O
w
1
I
'
Q
x
U
W,
R�
NUMEER