Loading...
HomeMy WebLinkAboutINSTALLATION & OPERATION MANUALr . I i SCANNED) and By eries St Lude coon y° INSTALLATION AND OPERATION MANUAL ENGLISH ( FRAN9ES I ESPANOL Jandy Pro Series VS RoProTM Serges Variable -Speed Pumps p FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product Will be installed where such state or local requirements exist. The maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly. Before installing this product, read and followall warning notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in property damage, personal injury, or death. improper installation and/or operation will void the warranty. improper installation and/or operation can create unwanted electrical hazard which can cause serious injury, property damage, or death. ATTENTION INSTALLER -This manual contains important.inforination aboutthe installation, operation and safe use of this product. This information should be given to the owner/ operator of this equipment. Page 2 Jandf Pro Series VS FloPr6m Series Vadable-Speed Pump I Installation & Operation Manual of Contents Section 1. Important Safety Instructions .......1.. 3 1.1 Safety Instructions ...........................................`.. 3 1.2 Pool Pump Suction Entrapment Prevention Guidelines .................... 5' . . Section 2. General Description .......................�6 2.1 Introduction ................................. :....................... 6 2.2 Description......................................................... 6 Section 3. Installation Information—i...................6 3.1 Plumbing............................................................ 6 3.2 Electrical Installation ...........................................9 3.3 VS FloPro Pump Dip Switch Setrings .........:.....13 3A Auxiliary Load Operation..................................14 3.5 Remove Pump Lid...::......................................15 3.6 Conduct Pressure Test.....................................15 Section 4. Operation.......................................16 4.1 Startup............................................................15 Section 5. Service and Maintenance.............17 5.1 Routine Maintenance.......................................17 52 ,Winterizing the Pump.......................................17 6.1 - Service Technician Maintenance ...................... 20 Section 7. Product Specifications and Technical Data ....................... 21 7.1 Replacement Parts, List and Exploded View.... 21 7.2 ..Exploded Views ................................................ 22 7.3 - Performanc&Curves......................................... 23 7.4 Physical and Operational Specifications .......... 23 EQUIPMENT INFORM) RECORD - DATE OF INSTALLATION i INSTALLER INFORMATION 4 INITIAL PRESSURE.GAUGE READING (WITH CLEAR FILTER) I PUMP MODEL 'HORSEPOWER NOTES: JandyG Pro Series VS RoProvi Series VadableSpeed Pump I InstaAa6on & Operalion Manual Page 3 Section 1. Important Safety Instructions READ AND FOLLOW ALL INSTRUCTIONS 1.1 Safety Instructions All electrical work must be performed by a licensed electrician and conform to all national, state, and -local codes. When installing and using this electrical equipment, basic safety precautions should aIway-s be fgIIowed, including the -- A. WARNING RISK OF SUCTION ENTRAPMENT HAZARD,IWHICH, IF NOTAVOIDED, CAN RESULT IN SERIOUS INJURY OR DEATH. Do not block pump suction, as this can cause severe injury or death. Do not -use this pump for wading pools, shallow pools, or spas containing bottom drains, unless the pump is connected to at least two (2) functioning suction outlets. Suction outlet (drain) assemblies and their covers must be certified to the latest published edition ofANSI0/ASME®A112.19.8, or its successor standard, ANSI/APSP-16. I A WARNING To reduce the risk of injury, do not permit children to use this product. A WARNING To reduce the risk of property damage or injury, do not attempt to change the backwash (multiport, slide, or full' flow) valve position with the pump running. i A WARNING Jandy Pro Series pumps are powered by a high voltage electric motor and must be installed by a licensed or certified electrician or a qualified swimming pool service technician. A WARNING Due to the potential risk of fire, electric shock, or injuries to persons, Jandy Pro Series pumps must be installed -in accordance with the National Electrical Code® (NEC"), all local electrical and safety codes, and the Occupational Safety and Health Act (OSHA). Copies of the NEC may be ordered from the National Fire Protection Association, 470 AtlanticAve., Boston, MA 02210, or from your local government inspection agency. A WARNING RISK OF ELECTRIC SHOCK, FIRE, PERSONAL INJURY, OR DEATH. Connect only to a branch circuit that is protected by a ground fault circuit interrupter (GFCI). Contact a qualified electrician if you cannot verify that the circuit is protected by a GFCI. A GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI, push -the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the pump without the test button being pushed, a ground current is flowing, indicating the possibility of electrical shock. Do not use the device. Disconnect the device and have the problem corrected by a qualified service representative before using. A ,WARNING - .causing_severe-injury-or_property-damage. Page 4 Jandy®Pro Series VS FloPro7" Series Variable -Speed Pump (Installation &Operation Manual WARNING • Do not connect the system to an unregulated city wafer system or other external source of pressurized water producing pressures greater than 35 PSI. I • Trapped air in system can cause the filter lid to be blown off, which can result in death, serious personal injury, or property damage. Be sure all air is out of the system before operating. To minimize the risk of severe injury or death, the filter and/or pump should not be subjected to the piping system pressurization test. Local codes may require the pool piping system to be subjected to a pressure test. These requirements are generally not intended to apply to the pool equipment such as filters or pumps. ZodiacP pool equipment is pressure tested at the factory. However, if the WARNING cannot be followed and pressure testing of the piping system must include the filter. . and/or pump, BE SURE TO COMPLY WITH THE FOLLOWING. SAFETY INSTRUCTIONS: • Check all clamps, bolts, lids, lock rings,and system accessories to ensure they are properly installed and secured before testing. • RELEASE ALL AIR in the system before testing. • Water pressure for test must NOT EXCEED 35 PSI. • Water temperature for test must NOT EXCEED 100 ? F (380C). • Limit test to 24 hours. After test, visually check system to be sure it is ready for operation. NOTICE: These parameters apply to Zodiac equipment only. For non -Zodiac equipment, consult equipment manufacturer. A WARNING Chemical spills and fumes can weaken pool/spa equipment. Corrosion can cause filters and other equipment to fail, resulting in severe injury or property damage. Do notI store pool chemicals near your equipment. = A CAUTION Do not start pump dryI Running the pump dry for any length of time will cause severe damage and will void the warranty. A CAUTION This pump is for use with permanently installed, pools and may also be -used with hot tubs and spas, if so marked. Do not use with storable pools. A permanently installed pooi is constructed in or on the ground or in a. building such that it cannot fie readily disassembled for storage. A storable pool is constructed so that. it.may be readily disassembled for storage and Yeassembled to its original integrity. A CAUTION ' Do not install within an outer enclosure or beneath the skirt of a hot tub. The pump requires adequate ventilation to maintain airtemperature at less than -the maximum ambient temperature rating listed on the motor rating plate. SAVE THESE INSTRUCTIONS I Jandf Pro Series VS FloftTm Series Vadable-Speed Pump I In`stallaft & Operation Manual Page 5 1.2 Pool Pump Suction Entrapment Prevention Guidelines 8 WARNING SUCTION HAZARD. Can +cause serious injury or death. Do not use this pump for wading pools, shallow pools or spas containing bottom drains, unless the pump is -- — -- - connected to at least two (2) functronmg suction outlets. WARNING Pump suction is hazardous and can trap and drown or disembowel bathers. Do not use or operate swimming pools, spas, or hot tubs if a suction outlet cover is missing, broken, or loose. The following guidelines provide information for. pump installation that minimizes risk of injury to users of pools, spas, and hot tubs: Entrapment Protection - The pump suction system must provide protection against the hazards of suction entrapment. Suction Outlet Covers -All suction outlets must have correctly installed, screw -fastened covers in place. Ali suction outlet (drain) covers must be properly maintained. They must be replaced if cracked, broken, or missing. Drain covers must be Misted/certified to the latest published edition of ANSI®/ASME® All2.19.8 or its successor standard, ANSi/APSP-46. The pool must be shut down and bathers must be restricted from entering the pool until any cracked, broken, or missing drain covers are replaced. Number of Suction Outlets Per°Pump 1 Provide at least two (2) hydraulically -balanced suction outlets, with covers, as suction outlets for each circulating pump suction line. The centers of the suction outlets (suction outlets) on any one (1) suction line must be at least three (3) feet apart, center to center. See Figure 1. The system must be built to include at least two (2) suction outlets (drains) connected to the pump whenever the pump is running. However, if two (2) suction outlets run into a single suction line, the single suction line may be equipped with a valve that will shut off both suction outlets from the pump: The system shall be constructed such that it shall not allow for separate or independent shutoff or isolation of each drain. See Figure 1. ! Additional pumps can be connected to.a single suction line as long as the requirements above are met. Water Velocity - The maximum water velocity through the suction outlet assembly and its cover for any suction outlet must not exceed the suciion._outiet assembly and its cover's maximum design flow rate. The suction outlet (drain) assembly and its cover must comply with the latest version of ANSINASME® All2.19.8, the standard for Suction Fittings For Use in Swimming Pools, Wading Pools, Spas,and Hot Tubs, or its successor standard, ANSi/ASME APSP 16. Testing and Certification - Suction outlet covers must have been tested by a nationally recognized testing laboratory and found to,comply with the latest published edition ofANSi/ASME All2.19.8,or its successor standard, ANSI/APSP-16, the standard for Suction Fittings For Use in Swimming pools, Wading Pools, Spas, and Hot Tubs. Fittings - Fittings restrict flow; for best efficiency use fewest possible fittings (but of least two (2) suction outlets). Pool cleaner suction fittings must conform to applicable International Association of Plumbing and Mechanical Officials (IAPMO)standards. age 6 Jandy° Pro Sedes VS FloProlm Series VadableSpeed Pump I Installation & Operation Manual ar E E ow Listed/certified to the latest published version of ANSI®/ASME®A112.19.8 or its successor standard, ANSI/APSP-16. . .Anti-entrapment-�—_ Cover/Grate or Suction Fitting, securely fastened to Main Drain Sump At Least I 3 Feet I r NI valves between Tee and Main Drains Suction Outlet —r "'� (Main Drain) Valves permitted only a Ei Figure 1. Number of Suction Outlets Per Pump Section 2. General Description 2.1 Introduction This manual contains information for the proper installation, operation, and maintenance of Jandy Pro Series VS FloPro variable -speed pumps. Procedures in this manual must be. followed exactly. To obtain additional copies of this manual, contact Zodiac® Customer Service at 800.822.7933. For address information, see the back cover of this manual. 2.2 Description i The VS F1oPro, is a variable -speed pump .that can be run from 600 RPM to 3450:RPM. When connected to the JEP-R controller, up to eight (8) speed settings may be programmed and recalled. This allows you to select the most appropriate speed for your application. Even more versatile programming is possible when you use an AquaLink® RS, AquaLink PDA, or AquaLink Z4TN controller. The pump is driven'by a variable speed ECM - . (Electronically Commutated Motor) directly attached to the -pump impeller. The.motor spins the:impeller which forces water to flow through the pump. As the speed of the motor is varied the flow through the pump is also varied. The adjustable flow rate allows for optimization of flow during the varying pump cycle requirements. As a result the energy efficiency of the pump is maximized resulting in cost savings to the pool owner while also helping to save the environment. Listed/certified to the latest published version of ANSI/ASMEA112.19.8 or its successor standard, ANSI/APSP-16. Arif-entraamenf�°=---- CoverlGrate or Suction Fitting, securely -fastened / to Main Drain Sump E— Suction Outset (Main Drain) Pump Section 3. Installation. Information 3.1 Plumbing Preparation Information. 1. . Upon receipt of the pump, check the carton for damage. Open the carton and check the. pump for concealed damage, such as cracks, dents'or a bent base. If damage is found, contact the shipper or distributor where the pump was purchased. 2. Inspect the contents of the carton and verify that all parts are included, see Section 7.1, Replacement Parts List and Exploded View , Pump Location 1. Zodiac Pool Systems, Inc. recommends installing the pump within one (1) foot (30 cm) above water level. The pump should not be elevated more than -five (5) feet above the water level of the pool. NOTE The pump is NSF certified as being able to prime at heights up to.10 ft above the pool water level, at sea I evel. However, to achieve better self -priming, install the J pump as close as possible to the water level of the pool. " 2 If the pump is located below water level, isolation valves must be installed on both the suction and return lines to prevent back flow of pool water during any routine or required servicing. A WARNING A check valve can interfere with the proper operation of certain Suction Vacuum Release System (SVRS) products. To avoid possible en- trapment hazard, serious injury, or death, matte sure to review the operation/owners manual of your particular SVRS product before installing the check valve. Jand? Pro Series VS FloProw Series Variable -Speed Pump I Installation & Operation Manual Page 7 POOUSPA PUMP 3 WAY VALVE FILTER HEATER a. ram- ,..-:.�•,:•"�,r. r _..,:••,- '- _i.�._" yea?-r.°:.. 'i.`.:ai•.�:•.�i�a'•.: %�,:. 1 •s; .. :i Ii:iY �'.;it p. =a-:..ir•5�_-.. is 3tt `� ��:; .� s- :=SKI(ifINIE _ /' I:,:S vF.•a ,: '�'� "F"'.': rl;.••t a.3 a f��v�;}?: }::i CHECK VALVE ?3t� �=�=::._. ..,;;•,� ';c't1= _ _ (CherkVatverecommended •z':+:J Feeders;- � ..?.:;•si:..:• :4�• a(i�Sf•Isu isFr:?=�:�.'-'•;::.�Trr - :.l>..:;:_... sys 1nlh tlDslon _ ,. .y n �� _ Ce;••. tar lemstnstaQed .ai' •$�':��7i:�, �'� •r �� j; L+` .M1 ,?;�..r,�. _ ::<.- ••'c::' 't:.tl;�i4_-.I:.1,..:,. orA ua uWsahchlo :%'a3«• -'3a,� :tip =ii;%;:{:-.:�a�`::iy %f•'7••' ..�Fi� �.• •:? •;:�:�,F Q P dnatlonsystems) _ gin. .�. -• i,:•`•� n,,;.�.;::^. '• '''"� jai 7ti-�s.'='?.._. :%i:VS_ :=!;.:.•' .i!t:f .-1,-i - '%Ji�r!'L�-r i'�•'-'Y�:a.I�Y• .��...,!:._ � - �`�.•��1rt `. _!�%?'•= _ •r(>�•�- F Si==c" :rMA1N�p '= c;:`-:�a;`'•+'•:•_`� cj.c5 • it-.• , . ). '_-• «. I'.__ = �•i;.. �f1s...-us•.FIZ._a: �'.,C--Sf,.r 3� 1CY �•at •.:•_cv{`•._��'i;.N, ' t�•'7.i:' r3'.6�• .r, - _ t��'• :i �•Yr.. _ .�:!1.'�..,ry,:,'::: ''.Se`*:•�5= •4;i1 � �: 5:7. ` :'FS . _ ::�"..... tir . :.�;: a:%-7iQPUonahr; ;.:-j0' � s•_ic�:;.. ''=.J� .:7..c.. vr. •.f.: - ::,4pi • .1: • u- : �:'.:'�i: �,;•f�,�: i�__t - yEr <@:-�i� :,;;•..L.;hCleaner:SuctiDn;P•oit=`ti;:•, f.r,�-`- _.��.;:._,� _ - - •.''�t:i•li• al., i:j,.r • `�^ria.: yTs.•'•y ��:':.. r.�..�::�'. i�_';.'7T/' j:�.', ':YY•C�Il._^:.:li N�• •.1::� �R?: t'7.`.�c�',,,'..T. :•yt::.: �.f1 �--•. .: ?.i::!�� ;1.: t;li�;.•i.1w I L,- .'• y, :rt':V -: �:,• _ • a�-;,Y%,i:= , ... = x•.:z''�;='...r; =;,`: y. SPADRAIN •p:.. ;'„ ::c �` a�_•c� .t.:n;�•i#.'r{p,r � ::,;�.•' (SuCtionOuUeq SPA RETURN _ i:. - s -' :`.;.:•,'; %., '3_ MANUAL BYPASS VALVE Si POOL MANUALBXPASS DETAIL - RETURN USENMEMMInoNnATe EXCEEDS 12SGPMFORZODIM ••:•.• HFATERS.RUMTOTHEMANUFAC. TURERS RECOMMENDARORS U` USING A DIFFERENT D RAND HEATER. rigure z. typical Piping Installation NOTE When the pool equipment is located below the pool surface a leak can result in large scale water loss or flooding. Zodiac Pool Systems, Inc., cannot be responsible for such water loss or flooding or damage caused by either occurrence. 3. InstaIl the pump such that any disconnecting means and/or junction boxes for power connection are within sight of the pump and at least five (5) feet horizontally from the edge of the pooi and/or spa. Choose a location that will minimize,turns in the piping. NOTE In Canada, the minimum distance maintained from the edge of the pool and/or spa as noted above must be 3 meters (10 feet), as required'by the Canadian Electrical Code (CEC, CSA C22.1). 4. The pump must be placed on a solid foundation that will not vibrate. To further reduce the possibility of vibration noise, bolt the pump to the foundation, or place it on a rubber mat. NOTE Zodiac Pool Systems, Inc. recommends bolting the pump directly to the foundation. S. The pump foundation must have adequate drainage to -prevent the-motor-from-getiing-wet. Protect -the pump from the rain and sun. 6. Proper ventilation is required for the pump to operate normally. All motors generate heat that must be removed by providing proper ventilation. 7. Provide access for future services by leaving a clear area around the pump. Allow plenty of space above the pump to remove the lid and basket for cleaning. 8. If the equipment is in a potentially dark area, provide adequate lighting. Pipe Sizing For assistance with suction and discharge pipe sizing, please see Tabled. Installation Recommendations 1. To help prevent difficulty in priming, install the suction pipe without high points (above inlet of pump = inverted "U71s, commonly referred to in plumbing as an airlock) that can trap air. For installations of equipment up to 100 feet (30 m) from the water, refer to Table 1, the pipe sizing chart. For installations of equipment more than 100 feet (30 m) from the water, the recommended pipe size must be increased to the next size. ' - 8 Jandya Pro Series VS FloProTM' Series VadableSpeed Pump I Installation & Operation Manual Figure 3. Table 1. tP' y �""Alt^^'.. pe$ize� �� i,•r.-.�,..y,+�,;:§}'•:J""•��ti'• •-��Maxrrreum=F,ibwr ,Yrsti'A::SCC.att_"'•-��,•n�ti ��illlax�mum�Flow��-�. • "';2'. N "�c� ••^JY-_;•kx��:�? > ��tirs Dcharge•w.• 1=4rn"�a.:!:rni_ie�t�is _ .aif.'� •:Ja-r`ar>i �c:::a:._..::rsw..M a:s5oa' .zx:-::ra;r��a:: 1%" . 37 GPM (140 LPM) 50 GPM (189 LPM) (38 mm) 2„ (51 mm) 62 GPM (235 LPM) 85 GPM (322 LPM): 2%" 88 GPM-(333 LPM) 120 GPM (454 . (64 mm) LPM) 3" 136 GPM-,(515. 184 GPM (697 (76 mm) LPM). LPM) .: 4" 234 GPM (886 313 GPM (1185 (102 rn LPM) . LPM) � . 2. VS F1oPro Pumps come equipped with unions on both the suction and discharge ports. This feature simplifies installation and service and eliminates the possibility of leaks at threaded adapters.' 3. The VS F1oPro Pump must be connected to at least two. (2) hydraulically -balanced main drains for each pool pump suction line. Each drain (suction outlet) assembly must be. provided with covers and must be listed or certified to the latest published edition of ANSI®/ASME®A112.19.8, or its successor standard, VS FloPro with Small No Base Required Option Haywar& Super PumpP t PentaU°SuperFlo® Sta-Rites SuperMaiP Small Base Option HaywardSuperl[M 2 JandyPlusHPbyzi Dandy Max HP byZ Pump Height Suelioil Side Height Option Small Base with spacers' I I PentairMsperFlo I 3 Sta-Rite Dyna-GIasTM small Base +Large Base Sta-Rite Max E Proo 01111 Option-.Sta-MteDura-GlasP a` Sta•Rite Dura-Glas II Sta-Rite Max-&Glaso. *Optional (Osier R0546400) VS FloPro Pump and Base Options Pipe Sizing Chart for Schedule 40 PVC ANSI/APSP 16. The suction fittings of the main drains must be at least three (3) feet•(1 m) apart or at different planes. The suction fittings can be a drain and skiminer, two (2)-drains, two (2) skimmers, or a skimmer with an equalizer line installed. Check the local codes for proper installation.. [MOTE To prevent entrapment, the system must be built so 1 it cannot operate with the pump drawing water from only 1 one (1) main drain. At least two (2) main drains must be connected to the pump when it is in bperation. However, if . two (2) main drains run into a single suction line, the single suction line maybe equipped with a valve that will shut off both main drains from the pump. " 4. The piping must be well supported and not forced together where it will experience constant stress. 5. Always use properly sized valves. Jandy Pro Series Diverter Valves and Ball Valves typically have the best flow capabilities.. 6. Use the fewest possible fittings especially 90 degree. . elbows. Each additional fitting or length ofpipe increases resistance to flow which makes the pump work harder NOTE If more than ten (10) suction fittings are needed, the pipelslze must be increased. 1 Jandya Pro Series VS FloProM Series VadetiMpeed Pump I Installation & Operation Manual AdMEMW Page 9 i 7. Every new installation must be pressure tested' according to local codes. Replacement of Existing Pump Jandy Pro Series VS FloPro pumps can easily replace several other pumps: the Hayward® Super Pump® Hayward Super IITM Pentair' SuperFIo® Pentair --—WhisperFl&- -Jandy-P-ro-Series,-P1usHP-(PHP),-Jandy - --- Pro Series MaxFIP (1V1PIp), Sta Rite® Dura-Glas, Sta Rite Dura-Glas II, Sta Rite Dyna-G1asTM Sta Rite . Max E-Glas® Sta Rite Max E-Pro® and Sta Rite SuperMax®. f To replace the Pentair WhisperFlo, Jandy Pro Series PHP, or Jandy Pro Series-MHP, use the VS FloPro's adjustable base. The VS FloPro base (and its spacers) increase the total height of the pump and the height of the suction side ofthe pump. See Table 2 and Figure 3. NOTE Adjustable base comes with FloPro models VS-FHP1.0, VSFHP165JEP, VS-FHP2.0 and 1 VSFHP270JEO If adjustable base is required for VSFHP270AUT or VSFHP165AUT please see item 18 in section 7.1 'Replacement Parts List and Exploded Mew° laple z. VS FloPro Dimensions ;: ":t•; V; Y"s=r''..`-.'i� "r,;f��;,r.r±�i ri:.:a�:�,r� ..�yL �G—a •.. l ��.5•��: �.i3 �:1'. �i:;ru.�_7; �C:.: �•�;:u;+i5 �ii7'.:S:Y-l��f i Yr SUC�rOn• cf Li'J'�i:Z�My.3•.'./f;:: C.r+.3ir f,�prp; ��:-j: . Via„•` -,; s [•.:5%✓�I'� \}A:c- <sa•R'-.. ��..i .Lis :d'J.=e?..f `�� , �ct.�`.r�^ ��y_;�y....� T};=-�;;_x-r , , �C=::T.•'� �Y�i tHerght'rr.r-.: sr-��.•«���;s,._. .trs''ii=.u.rin . \ i S��f} :�;3�s,z 1-lerght�--�,;.��..., 1. ..iirnd 7 3/4" ;.. .:�l::':2•T `�•.- 12 3/4" 1. Pump without Base (197 mm) ;(44 mm) 2. Pump with Base 9" , t 14" (229 mm) (356 mm) 3. Pump with Base and 9114" 141/4" Spacers 235 mm) ; (362 mm) 4. Pump with Small + Large 10 7/8" : i 15 7/8°. Base 1276 mm) , (403 mm) Install Spacers into Small Base i 1. Using a hand cutter tool, cut the plastic bars connecting the top and bottom sets of spacers, as shown in Figure 4. 2. Push the two (2) top spacers and two (2) bottom spacers out ofthe base. 3. Align the pins in the four (4) spacers with the holes in the base and snap the spacers into place, as shown in Figure S. \�l�16I1� Figure 5: Snap Spacers into Place 3.2 Electrical Installation' Voltage Checks The correct voltage, as specified on the pump data plate and Table 3.on page 10 is necessary for proper performance and long motor life. Incorrect voltage will decrease the pump's ability to perform and could cause overheating, reduce -the motor life, and result in higher electric bills. It is the responsibility ofthe electrical installer to provide data plate operating voltage to the pump by ensuring proper circuit sizes and wire sizes for this specific application. The National Electrical Code® (NEC% NFPA-70) requires all pool pump circuits be protected with a Ground Fault Interrupter (GFCI). Therefore, it is also the responsibility ofthe electrical installer to ensure that the pump circuit is in compliance with this and all other applicable requirements of the National Electrical Code (NEC) and any other applicable installation codes. A CAUTION Failure to provide data plate voltage (within 1076) during operation will cause the motor to overheat and void the warranty. Bonding and Grounding 1. In addition to being properly grounded as described in Electrical Wiring section, and in accordance with the requirements-ofthe National Electrical Code (NEC), or in Canada the Canadian EIectrical Code (CEC), the pump motor must be bonded to all metal parts ofthe swimming pool, spa or hot tub structure and to all electrical components and equipment associated with the pooUspa water circulation system. The bonding must be accomplished by using a solid copper conductor, No. 8 AWG or larger. In Canada No. 6 AWG or larger must be used. Bond the motor using the external bonding lug provided on the --motor-frame. --- ® WARNING Mays disconnect the power source before working n a motor or its connected load. Figure 4. Cut Sets of Spacers Out of Base Page 10 Jandye Pro Series VS FloProTO Series Variable -Speed Pump I 'Installation & Operation Manual Table 3. Recommended Wire Sizes for VS FloPro Pumps „J,•{A=i 4: �.r.•.�K':�ti' `Y �MteY?C;e.)rrt: Lti7C•".'CS.•tii=.•.:l �=f=i wY.., �•aro.i:v.T•-e;:!.y: RECOMMENDER�MINIM.l11MnWIRE SIZEjFOR�IMS r. ly:. �1f..�G.+tGyrCx.^..bii.:y, �wv..:..yC{ti�t:l r`i'•�` 131101 r.y �. ,, ._.Ta.•_?.?�:n�.r '. .rh�:y,vx-��.a .n - r_r n. s : a s_� ca a.,��a•?: Ta wr. �•.r. x.^.rr11�i�%�a.� . ; ^Sjc. v:,; !. iY•.x4.��Y.:l.s ,:� Fit.4u S a.3 _ 0-450 Feet Distance from Sub -panel' I (o4s metres) Branch Fuse AMPS Gauge of Wire Model Class: CC; G, H, J, K, RK, or Voltage 230 VAC 230 VAC -VS-FHP1:o; VSFHP165AUT; VSFHP-165JEP _::.. - _:_ : = _ .. 15A:::.- VS-FHP2.0, VSFHP270AUT, VSFHP270JEP 20A 10 *Assumes three (3) copper conductors in a buried conduit and 3% maximum voltage loss in branch circuiLAll National Electrical Code® (NECO) or the Canadian Electrical Code (CSA) and local codes must be followed. Table shows minimum wire size and branch fuse recommendations for typical installation. A WARNING Make sure that the control switch, time clock, or control system is installed in an accessible location, so that in the event of an equipment failure or a loose plumbing fitting, the equipment can be turned off. This location must not be in the same area as the pool pump, filter, and other equipment. A CAUTION ' The pump must be permanently connected to a dedicated electrical. circuit. No other.equipment, lights, appliances, or outlets may be connected to the pump circuit, with the exception of devices that may be required to operate simultaneously with the pump, such as a chlorinating device or heater.' Bonding Lug Breaker Panel --GROUND •• -., 'Z rl mmm 0 o s,c®. Terminal Block Variable -Speed Pump (230 VAC) Figure 6. Bonding the Motor Electrical Wiring 1. The pump motor must be securely and adequately grounded using the green screw provided. Ground before attempting to connect -to an electrical power supply. Do not ground to a gas supply line. 2. VNue size must be adequate to minimize voltage drop during the startup and operation of the pump. See Table 3 for suggested wire sizes. 3. Insulate all connections carefully to prevent grounding or short-circuits. Sharp edges on terminals require extra protection. For safety, and to prevent entry of contaminants, reinstall all conduit and terminal box covers. Do not force connections into the conduit box. NOTE When power alone is supplied to this pump, tt will not operate. it requires a digital command sent to it by either a variable speed controller (JEP-R),'an Aqual_[W RS controller, anAquaUnk Pool Digital Assistant (FDA), or an AquaLink Z4TMr, to operate at a chosen speed. VS FloPro Controller Options The VS FloPro pump can b'e'operated by one (1) of four (4) controllers: the JEP-R variable -speed controller, the AquaLink RS controller (Rev O or later), the AquaLink PDA (Rev 4.0. or later), or the AquaLink Z4. The VS FloPro variable -speed pump communicates Vith the controllers via a four -wire RS-485 interface. Controller'lnstallation Options The VS-FHPI.0, VSFI P165JEP, VS, FHP2.0, & VSFBr270JEP pumps come pre -configured for the JEP R variable -speed controller with DIP switch settings .pre -configured to work with this.controller. The VSFBP I 65AUT and VSFID270AUTPumps come . pre -configured for installation with the AquaLink RS, .AquaLink PDA, or AquaLink Z4. -To linstall with an AquaLinkRS controller (Rev O or later), an AquaLink PDA (Rev 4.0 or later), or an' AouaLink Z4: t. I Remove power from the VS FloPro pump by - disconnecting the high voltage lines or by turning off any breaker to which the VS FloPro pump Hower is connected. A WARNING ELECTRICAL SHOCK HAZARD Turn off all switches and the main breaker in the variable - speed pump electrical circuit before starting the procedure. Failure to comply may cause a shock hazard resulting in severe personal injury or death. 2. Remove the access cover to complete electrical connections to the motor. I - Jandf Pro Series VS FloPro7m Series Vadable-Speed Pump I Installation & Operation Manual Adir 4111TEW Page 11 6. Connect the RS-485 connector on the AquaLink® RS (or multiplexer interface board), matching wire colors with connector positions as follows: I -red, 2-black, 3-yellow, and 4-green. See Figure 7. 7. Restore power to the pump and verify the operation of the controller. - ---Refer to -the appropriate manual -for get. ap and-- ---- _- operation of the pump: AquaLink RS Owner's Manual, 6593, AquaLink PDA Owner's Manual, H0572300, or AquaLink Z4TM Owner's Manual, H0386600. JEP-R Remote Mounting The variablerspe'ed controller may be remote mounted onto a vertical surface that is protected from the elements. Follow the directions carefully to maintain the ability to reinstall the variable -speed controller onto the Pump. Reverse these instructions to complete the reinstallation. See Figure 8. . A WARNING ELECTRICAL SHOCK HAZARD Turn off all switches and the main breaker in the variable - speed pump electrical circuit before starting the procedure. Failure to comply may cause a shock hazard resulting in severe personal injury or death. Figure 7. Wiring AquaLink RS Controller or AquaLink PDA 3. Slide dip switches 1 and 2 down to the OFF position. If applicable to your pump model slide dip switch 5 up to the ON position. See Figure 7. 4. Select the desired address(es) for the pump by setting dip switches 3 and/or 4, as shown in Section 3.3, VSMoPro Pump Dip Switch Se#ings. 5. If short RS485 cable or JENR controller is pre installed: a. Disconnect the RS485 cable from the 4-pin Figure 8. Disconnect Variable -Speed Controller header on the pump drive. from Pump Note: Do not cut the cable, or you will lose the ability to return —to-the-defaultfactoryconfiguration. - ---- — - --- — b. Connect the new RS-485 cable from the AquaLink through the available compression fitting and route the 4-conductor cable through the motor.drive threaded port closest to the connector. Figure 7. Page '12 Jandy' Pro Sedes VS HoPrd"' Series Vadable-Speed Pump I Installation & Operation Manual A WARNING When determining routing and protection for the . variable -speed controller cabling, ensure that all . National Electrical Code® (NEC®) and all local code requirements are met. NEC code requirements prohibit the routing of signal cables in conduits or raceways that are used for branch, feeder, or sen►i� to -building routing of signal cables, with regard to lightening protection. At the pump: I. Remove power from the pump by disconnecting the . high voltage lines or by turning off or deactivatingI any breaker to which the pump power is connected. 2. Lift up the controller cover on its hinges to access the variable -speed controller. 1 3. Remove the six (0 screws to disconnect the 'variable -speed controller from the controller base on the Pump motor. i 4. Detach the RS-485 cable connecting the variable - speed controller user interface to the controller base I on the motor. Do not over extend the cable when raising the controller away from the motor. 5. Unscrew the four (4) connector terminals and I disconnect the wires ofthe motor cable assembly.. Note: Do not cut the cable, or you will lose the ability to return to the default factory configuration. 6. Bundle the loose wire into the pocket of the controller base. This wire will be used if reinstalling the variable -speed controller onto the Pump. 7. Secure the pocket cover and gasket with six (6) screws to the variable -speed controller base on the motor. 8. Remove the one (1) screw "and access cover to complete electrical connections to the motor. 9. Insert the free end of the new RS-485 cable through the available compression fitting and route "the 4-conductor cable through the motor drive threaded port closest to the connector. 10. Prepare the cable and attach another 4-pin connector, ensuring the wire colors match Figure 7. 11. Insert the RS-485 connector onto the corresponding RS-485 connector on the motor PCB. 12. Secure the compression fitting nut around the cable to secure the motor. 13. Verify the DIP switch settings match Figure 7. 14. Reinstall the access cover with the single screw removed in step 8. Follow the instructions in the Variable -Speed Controller User Interface Installation/Owner's manual (H0412200) to complete the remote mounting of the controller. To install the JEP-R variable-'sbeed controller., IMPORTANT The installer must TURN ON switches 1 and 2 at the VS-FHP2.0 pump when connected to the variable - speed controller. NOTE The variable -speed controller part no. is JEP R. the high voltage lines or by opening any breaker to which the pump power is connected. A WARNING ELECTRICAL SHOCK HAZARD Turn off all switches and the main breaker in the variable - speed pump electrical circuit before starting the procedure. Failure to comply may cause -a shock hazard resulting in severe personal injury or death. 2. Remove the cover of the junction box and feed the RS-485 cable into the fitting. 3. Unplug the RS-485 connector. 4. Attach the four (4) wires in the RS-485 cable to the RS-485 connector.'Match the wire colors with the positions on the connector: I- red, 2- black, 3- yellow, and 4- green. See Figure 9. 5. - Insert the RS-485 connector back into the pump. 6. Slide dip switches I and 2 up, so they are in the ON position, and slide switches 3 and 4 down, so they. are in the OFF position: See Figure 9. Jandy° Pro Series VS FloPro'M Sedes Vadab"peed Pump I • Installation & 0perallon Manual Page 43 Controller (Rear View) _m h� Q Remove to ^ac Tess ci 0�,123 4-Position DIP Switch 6-Position DIP Switch ,gat Power wiring Port I vw),Two;�- Product may dtferrminrmages shown Figure 9. Wiring Variable -Speed Controller (JEP-R) 7. Connect the other end of the cable to the controller. Match the colors ofthe wires with the appropriate connector positions as follows: I- red, 2- black, 3- yellow, and 4- green. i 8. Restore power to the pump and verify the operation of the controller. 9. Refer to the Variable -Speed Controller' Owner's Manual, H0412200, to operate the pump. I ' VSFHP166JEP Motor 3.3 VS FioPro Pump Dip Switch Seffings The 4- or 5-position dip switch is located at the rear of the VS F1oPro pump. This dip switch serves two (2) functions: it selects the pump address, and it determines what type of controller will be used with the pump. Table 4. VS-FHP1.0, VSFHP166AUT & VSFHP166JEP Dip Switch Settinas II c::••?7S`' �� f%;- a: rncr ` Swictc w•(b.0 , 3J ^�y=.:W�qi;-.,.•r'i•L1 �' �p, •Rw'7 %aa{ • • M' yi-1ri-/z)Yf ,,r-n 'a.rc•.;=_;- 'o•_o.K_wer '4^:' 1'..T��r1�:5 _ .C.:ltdNi J:a. . ....E .reS• ON ha AquaLink RS, AquaLink OFF OFF PDA, orAquaLinkZ47m ON ON ON Variable Speed Controller .5 ItCI].a?-•st,•�.,,''' �� •7,4; Switch " s'"o--c••r».tyj�.;•��,.iiAfd=.1`e•5-?7"L Pump;Address ,-•r � •l'•• ° .3,:ey:L:k: �':£:I1x:�%r .: qL �a�; ^'k Tog ON OFF PUMP 2 OFF ON PUMP 3 ON ON PUMP Table 5. VS-FHP2.0, VSFHP270AUT & VSFHP270JEP Dip Switch Settinas c�-s', +�".i• j�J.:. FG� �: r rYite w� _.✓..ex fks` ••. _.'•Df ' �1. T 2' ei_::%f i.=yi..r-i :.s,-• .ijy,.,, �•tir �,G-.' .s?-.:�b.=i 3:r.L"� r;+�•: +13.-t'= ' .ir: ••'�,�;�.N ��i?:Sil ::tom= :�%sa� �2.`iai�r.: �•,:�'�'*�Sri�..�"-."— rF'`-.�'% ''�_% 3•�3'L • ti. �i:nw'.'._.�t; _ iw OFF OFF AquaLink RS, AquaLink PDA, or AquaLink Z4 ON I ON 1 Variable Speed Controller Switch:, i—. r,y -a��j' 101\1 ^� i+'7 1.• a 3Switch •-'•�S` _Im: ;�' Nw� j ja fig: .,wtT-0an,:� rm Address_ _� •---� ' ON 1r.1. •., ;Pi.§ .t. R is=x,—• r r �;�+ai• r�sl,' `--^• 7{'('.- _ I,.._crz5• c ••..:.. ri ...Y 7~a J ,(4:J•. �•�: ��t f•<<y:ifi•�•-i�:l1y� k •" f Lfi'::r � �i;iT� i7.'tSL�_.:�f i-ii1nR.�'.. 7C•_.I�J= L':2%arCU•�L,.V3vh•_lSSiwQ ON OFF PUMP 2 OFF ON PUMP 3 0 1 ON PUMP4 4 JandyO o Series VS FloPro7m Series Vadable-Speed Pump I Installation & Operation Manual 3A Auxiliary Load Operation Certain pump models are equipped with a terminal bar that provides user access to a built-in Auxiliary Load relay contact. This normally -open, dry contac is activated under certain operating conditions and primarily intended to be used to control external de that require system water flow for proper functionir such as heaters,:booster pumps,.salt water chlorinat See Figures 9 and 10 for comparlment's location d An access cover with -Phillips -head screw must be removed before proceeding. Auxiliary Load Connection Requirements A WARNING ELECTRICAL SHOCK HAZARD Due to the potential risk of fire, electric shock, or injuries to persons, Zodiac® Pumps and any auxiliary loads must be installed in accordance with the National Electrical Code® (NEC®), all local .electrical and safety codes, and the occupational Safety and { Health Act (OSHA). Copies of the NEC may be , ordered from the National Protection Association, 470 AtianticAve., Boston, MA 02210, or from your local government inspection agency. In Canada, Zodiac Pumps must be installed in l ' accordance with the Canadian'Electrical Code (CEC). I - The Auxiliary Load relay contacts are rated at 23OVIIIA RMS. Please ensure the requirements of the equipment to be connected to the Auxiliary . Load do not exceed this rating. 1 _ - c 0 O L2 L1 — L1 0 0 m (Black) 230V Power � 0 12 Source (Red or Black) Earth L2 - (Red or Biaak) Earth 230V EXAMPLEONLY Auxiliary NOTRepmenlaft of Load 81/wragconfiguiaGons Note: In ads eonrouraVon. k is rmpodant ro veriy,tha shared powersoun:o Is adequalelyrated to service Eoth the pump and the auxNaryoqutpmenL Figure 11. 230V Auxiliary Load, Shared Power Source Wiring Diagram 115V Power Source -, , =1 u 230V II Power I Source• S (RedI� Black) ' Une (YYhite) Una (Black) EXAMPLE ONLY 115V: AuxiitaNOTReplesenlaUWat ry Load agwningwgurdGons Figure 12. 115VAuxiliary Load, Separate Power Sources Wiring Diagram. Ll (Black) 230V Power L2 Source (Red or Black) Ll 230V tntaeK) Power Source L (RedorBlack) Line (Black) 230V EXAMPLEOl1LY Earth Auxiliary NOTRepn senlaGueof Load agwAPngconrigurarans 13. 230V Auxiliary Load, Separate Power . Sources Wiring Diagram ry Load Operation Characteristics ry Load relay contact activation is speed - ant, and behaves as follows: Contact Closure From a stopped condition, there is a three -minute delay before the Auxiliary Load contact is closed when the motor speed reaches and maintains a speed of at least 1725 RPM. From a running condition at below 1725 RPM, there is 'a five -second delay before the Auxiliary Load contact is closed when the motor speed reaches and maintains a -speedy of at least 1725 RPM. Jandya Pro Series VS FIDPro7m Series Vadable-speed Pump I Installation & Operation Manual Page 9 5 Contact Opening i If the pump speed is below 1725 RPM, the Auxiliary Load contact is opened. Contact openings are always immediate. 3.6 Remove Pump Lid 1. Make sure that the pump is turned -off. that--_. powers the pump motor is turned off. A WARNING ELECTRICAL SHOCK HAZARD Turn off all switches and the main breaker in the variable speed pump electrical circuit before starting the pros I dui Failure to comply may cause a shock hazard resulting in severe personal injury or death. A - WARNING, 'I ELECTRICAL SHOCK HAZARD Due to the potential risk of fire, electric shock,1 or injuries to persons, Zodiac® Pumps must be installed in accordance with the National Electrical Code® (NEC®), all local electrical and safety codes, and the occupational Safety and Health Act (OSHA). Copies of the NEC may be ordered from the National Protection Association, 470 AtlanticAve., Boston, MA 02210, or from your local government inspection agency. In Canada, Zodiac Pumps must be installed' in accordance with the Canadian Electrical Code (CEC). 3. tviaKe sure all necessary isolation valves are closed to prevent pool water from reaching the pump. 4. Following the markings on the locking'ring, turn the ring counter -clockwise until the `START' markings align with the ports. See Figures 14 and 5. Carefully remove the lid with locking;ring. 3.6 Conduct Pressure Test A WARNING When pressure testing a system with water, air is often trapped in the system duririg the filling process. This air will compress when.the system is pressurized. Should the system fail, this trapped air can propel debris at a high speed and cause injury. Every effort to remove trapped air must be taken, loosening the pump basket lid while filling the pump. A' WARNING Trapped air in the system can cause the .filter lid to be blown'off, which can result in death, serious injury, or property, damage. Be sure all air is properly purged out of the system before operating. DO NOT USE COMPRESSED AIR TO PRESSURE TEST OR --CHECK FOR.LEAKS.------ - - -------------------- WARNING . ELECTRICAL SHOCK HAZARD Do not pressure test above 35 PSI. Pressure testing must be done by a trained pool professional. Circulation equipment that is not tested properly might fail, which could result in severe injury or property damage. A WARNING When pressure testing the system with water, it is very important to make sure that the pump basket lid is completely secure. 1. Fill the system with water, using care to eliminate trapped air. 2. Pressurize the system with. water to no more than 35 PSI. 3. Close the valve to trap pressurized water in the system. 4. Observe the system for leaks and/or pressure decay. 5. If there are lid leaks, repeat this procedure. For Zodiac Technical Support, call 800.822.7933. Section .4. Operation 4.1 Start-up A CAUTION Never run the pump without water. Running the pump 'dry" for any length of time can cause severe damage to bpth the pump and motor and will void the warranty. - If this is a new pool installation, make sure all piping is clear of construction debris and has been properly pressure tested. The filter should be checked for proper installation, verifying that all connections and clamps are secure according to the manufacturer's recommendations. - — � VL►ARMING---- To avoid risk of property damage, severe personal injury or death, verify that all power is turned off before starting this procedure. ENGLISH Jandy G Pro Series V8 FloProTH Sedes Vadabte-speed Pump. I Installation & Operation Manual j Lid with Locking Ring ... ...1. _ Seal Figure 14. 0-ring in Lid Assembly Lid.with Locking Ring and Seal Pump Debris Trap Basket (inside Pump) Figure 16. Exploded View of Pump 5. 6. 8. 1. Depending on the location of the pump, do one of the foIlowing: , - If the pump is located below the water level of the i pool, open the filter pressure release valve to prime the pump with water. - If the pump is located above the water level of the pool; remove the lid and fill the basket with water - - -----._,... liefote-sfafin� tiie=nunin: �._:;..::.:---- `- - ___._:_._ _-- = ::: -..: • . 2. Prior to replacing the lid; check for debris around the lido ring seat. Debris around the lid o-ring seat will cause air to leak into the system and will make it difficult to prime the pump. Hand -tighten the lid to make an airtight seal. Do not use any tools -to tighten the lid: hand -tighten only. Make sure all valves are open and the uiuons are tight. Restore power to the pump. Then turn on the pump - by following the instructions in the appropriate manual: Variable -Speed Controller•Owner's manual, H0412200, AquaLink® RS Owner's Manual, 6593, AquaLink PDA Owner's Manual, H0572300, orAqugLink Z4TM Owner's Manual, H0386600. Once all the air_ has -left the filter, close the pressure release valve, The pump. should prime. The time it takes to prime will depend on the elevation -and length of pipe used on the suction supply pipe. See Installation Recommendations in Section 3.1 for proper elevation and pipe size. The default priming speed is 2150 RPM. The pump will take approximately .14-15 minutes to prime at this priming speed when the:pump is located ,10 feet above the pool.water. If priming speed is adjusted to 3450 RPM, the pump.should prime within 6 minutes at 10 feet above the water level. TE The pump is NSF -certified as being able to prime at heights up to 10 ft above the pool water level, at sea level. However, to achieve better self:priming, install the pump as close as possible to the water level of the pool. If the pump does not prime and all the instructions to this point have been followed, check for a suction leak. If there is no leak, repeat Steps 2 -through 7. For technical assistance, call Zodiac® Technical Suppoit at 800X&7933: Jandy° Pro Series VS FloPro7m Series Variable -Speed Pump I Installation & Operation Manuai Page 17 Section 5. Service and I 5.2 Winterizing the Pump Maintenance A CAUTION. ' i To avoid damage to the plastics, do not use lubricant used to install and lubricate the o-ring. 0.1 Koutme maintenance ; Inspect the pump filter basket for debris by looking through the clear pump lid. Remove any debris, because as debris accumulates, it will begin to block the flow of water through the pump. Keep the basket clean to improve the performance of the pump. 1. Turn off the power to the pump. If the pump is located below the water level, close the isolation valves on the suction and discharge sides of the pump to prevent backilow of water. 2. Turn the lid's locking ring counter -clockwise until 'START' aligns with the ports. Carefully remove the lid. A CAUTION A misaligned basket will cause the lid to be improperly seated, allowing an air leak, which could result in pump damage. 3. Lift the basket out of the pump. 4. Dispose of the debris and thoroughly clean the basket, making sure all the holes are open. Using a garden hose, spray the basket from the outside to help clear the Boles. Remove any remaining debris. by hand. 5. Replace the basket in the pump by aligning the opening with the suction pipe. If aligned properly, the basket will drop easily into place. Do notforce U into place. 6. Remove the lid seal and remove debris around.the lid seal seat, as this can allow air to leak into the system. CIean the lid seal and place it on the lid. 7. Replace the lid with locking ring. Hand -tighten the lid to make an.air--tight seal. Do not use any tools to tighten the lid: hand-tigluen only. 8. Verify that all valves have been returned to the proper position for normal operation. 9. Open the pressure release valve on .the filter, and make sure it is clean and ready for operation. —107.—Tum on the power to the pump. -Once all the air l been evacuated from the filter, close the pressure release valve. A CAUTION The pump must be protected when freezing temperatures are expected. Allowing the pump to freeze will cause severe damage and void the warranty. A CAUTION Do not use antifreeze solutions in the pool, spa, orhot tub systemslAntifreeze is highly toxic and may damage the circulation system. The only exception to this is Propyiene Glycol. For more information, see your local poollspa supply store or contact a qualified swimming pool service company. 1. Drain all water from the pump, system equipment,' and piping. 2. Remove the two (2) drain plugs. Store the drain plugs in a safe location and reinstall them when the cold weather season is over. Ensure drain plug o-rings are not misplaced. - ' 3. Keep the motor covered and dry. Do not cover the pump with plastic, because this will create condensation that will damage the pump. NOTE Zodiac Pool Systems, Inc. recommends having a qualified service technician or electrician properly disconnect the electrical wiring at the'switch or junction box. once the powerls removed, loosen the two (2) unions and store the pump indoors. For safety, and to prevent entry of contaminants, reinstall all conduit and terminal box covers. 4. When the system is reopened for operation, have a qualified technician or electrician make sure all piping, valves; wiring and equipment are in accordance with the manufacturer's recommendations. Pay close attention to the filter and electrical connections. S. The pump must be primed prior to starting. Refer to Section 4.1, Start-up.,_ Page 18 dandy- Pro Sedes VS FloProw Sedes VadabMpeed Pump I; Installation &.0pem9on Manual Section 6. Troubleshooting, and Repair Zodiac® strongly recommends that you call a qualified service technician to perform any repairs on the filter/pump system. To locate a qualified technician, check your local yellow pages or visit www.zodiacpoolsystems.com or www..- zodiacpoolsystems ca and click on "Dealer Locator.' 4r iil *-^`tirTi .+tti: .:I.�'•5.1 �5• i%.::G�'�TF: :.-.., •GY�. .>i.�11�•K.�n•.�• .✓-.�.•iy7.t°�.I iti:..iY~i�r "�• Ir iTV - - r� :t:yT•S'1 iv�.ti) ^G'^I� •-•ii .tis+'r 1.Z vyi?i•. tD��:�:.Y. �,i �.:�j✓.+.. .�l.tifj� H:j 3. - ^."sue "'.?..Y:� �,Y . �::� �%'�wl•.,TSS::t:�i�;,N•.Vi ��•1f n.-ai£..•-wri•'•..!:10�`^„[li*� •tiM��� 1.L..". 4 -..1tl?ossrb'Ie Cause/S_oiut�on Y:... 1•t .«. :.: d:• .., ..;+G;+•`Y_"`.'.. ^'r!?i:C%='•kT t �_t •�Z:.:��u�j� •K�iafih'�\.. �3C�i ;_�. '..y' • }..?f%.y, x+-t ^.i" .>..:di �h�' i/,]V:Y��i7.-- LY.=�i rt.., Jz. s.i.•rr �. _ ri :;.a':•.•,t Wiz. >. tip... Ir ��".L'.n ._""l.y.;� �� �..•t t...�.�t"�it tt-fi4 }1,��...�"•�...... GY'r. vLri'Z'::TG .�a.ls.�..•"!i•.Yr.. .A-l��iilA•:•�4�'.:� .I...wL{w..t••vT�va ""•:U�.ia....-.'..•..�•�ti•.....�Giw�iltiisi:l'M :i The cleanin /circulatiin " = = Veri t 'at=s i" " e s e = system is not operating necessary. correctly. Check .filter and clean) as necessary. Check valve positions.�Adjust as necessary. NOTE Multiple pieces of equipment operating at one time (for example, waterfalls, spa jets, and surface returns) will affect the proper operation of the cleaning system. Check the cleaning system manual to ensure that the system is adjusted according to the manufacturer's recommendations. Bubbles are present in the: Air.is in the system. Check the pool or spa water level to ensure that it is at the propef pump basket. level and air is not being drawn.into the suction piping. ,If the water is at the normal level, turn off the pump. Turn the lid's locking ring counter -clockwise until'STARr aligns with the ports. Remove the lid and do a visual inspection of the lid seal looking for cracks or gaps on the iubber surface. If none are observed, use a clean rag to wipe the surface -dean (note: the rag may show black material that came off the lid seat). Use the rag again to�clean the mating surface of the housing. Using a very small amount of silicone lubricant (no Vaseline) will help make a proper seal and protect the lid seal. Align 'START' with the ports and turn the locking ring clockwise until'LOCKED' aligns with the ports. Hand -tighten the lid to make.an air -fight seal. Do not use any fools to tighten the lid. Turn the pump back on. if problem is not resolved lid seal replacement.may be necessary. Air leaks are still present. Check the suction.side piping union. While the pump is running, try to tighten the union. If this does not stop the air leak, turn of the pump: Loosen both unions and slide the pump out of the way Remove, clean, and re -install both union o-rings. Reposition the pump next to the piping and secure the union nuts to the pump. With clear! union o-rings, hand -tightening of the unions should create a seal. If the unions still do not seal, gently tighten with a large pair of tongue=and-groove 'pliers. Do not over -tighten. There is no air in the !t is possible that debris is caughi,in the pump impeller. The pump impeller moves thewater, system, but the pressure is and the vanes in the impeller can become blocked with debris. See Section 6 9; Service still low. Technician Maintenance and Blocked Impeller, in this manual for more information. There is'no debris blocking The pump impeller and diffuser are showing signs of normal wear. Have a qualified the impeller and the service technician check the impeller and diffuaec and replace as necessary. pressure is still low. If the pump is part of a relatively new installation, it could be an electrical problem:, Contact a qualified service technician. Have the technician check for loose electrical connections and check the voltage at the pump motor while it is, in operation. The voltage must be within 10% of the motor's data plate rating. If the voltage is not within 10%, contact a qualified electrician'and/or the local power service provider. Pump seal is leaking air. Have a qualified service technician replace the seal. The pump is leaking water This is caused by a damaged or failed mechanical seal. Replace the seal. between the motor and Pump body. . i v - Jandf Pro Series V$ FlAoT" Series VadableSpeed Pump I Installation & Operation Manual Page 19 f^'L."1.Ta r».�.+�rnr. ia'!'i1 '� ."•.yl..i.i'�=. :+il .m tom.i;� �:� -2- :2,:; J;e:'••.XX'stT• .t: Y!•ifi:; :,a {r. •..•�!r'•. •:'•.min C-••f .s:i•_fi.a Jt: m7:/"aaa•..y I" - - •.•-•�^'i �:: �''•7i?F�y/stL'3! f,:..t.,. rt7' ...� z^.0 sv.%a.. S_N2::..ct N90 �r.W.i�•La Yy�•'.,?t;e;:?`v^-•iS:. •>J 1Y.ir1.' ,.u'�"7 l i F,„� ti�ZRQ =_,.. �; �tie:�yJ�,r,, ter,: ���. r.• 1:� ,;-,.1, Fr ,.�. T:3 �JMc ,osffible Cause/.$olutronq; : , =-mg r;n rJrA� 1?iks1�rS':l.;.t 1 .YP l.s wg:.. fr.':�• r'=El•r�'.?vS..d+eli.i_�!.::...ae:'aA:t_.Sc,, ;_r+:: _+� . • ... 5c�.�au�.t;,t-. i i: y }:: t ?, b+ n ,.a + 7�nt i ,;Lg?``'',. - E''tt'r 1�t Zir u'.-�+�.. e� ::• 5•, d r '�,*i.^ y.«J7• `*;- .0 ..3ia'M ate.•,^.. ,...�s: �.;.\c•:t+,.t:d. RN15..uil:d��1::5..., t z��'�:::L`: "i,^.e:G The pump gets hot and Make sure that there is adequate room around the motor to circulate air and keep the shuts off periodically. motor cool. Have a qualified electrician check for loose connections and check the voltage at the pump motor while it is in operation. The voltage must be within 10% of the motor's data plate rating. If the voltage is not within 10%, contact a qualified electrician and/or the local power service provider Pump Will not start _ --- _No power to pump. - - - — - Make sure pump is properly connected to high voltage. See Section 3.2, Electrical Installation, in this manual. Improper low voltage wiring. Check low -voltage wiring between pump and controller. Correct if necessary. See Section 3.2, Elecfncal Installation, In this manual. Improper pump address setting. Make sure that pump dip switches 3 and 4 are set properly for the installation. Both should be OFF for use with Variable -Speed Controller or set to the proper address when connected tol an AquaLink®RS controller, an AquaLink PDA, or an AquaLink Z4n". See Section 3.3, Pump Dip -Switch Settings, in this manual. Note: VS-FHP1.0 & VSFHP165JEP should always have dip switch setting 5 set to ON for both controllers. Fault condition exists. View fault message on controller and correct fault before proceeding. If unsure how to correct fault, contact Zodiac® Technical Support at 800,822.7933. Variable -Speed Controller Incorrect dip switch setting. LCD is not displaying Make sure pumpdip switches 1 and 2 are both ON if the controller is the JEP R and information both are OFF if the controller is a PDA, AquaLink IRS, orAquaUnk Z4: See Section or 3.3, Pump Dip Switch Settings, in this manual. Note: VS-FHP1.0 & VSFHP165JEP pump LEDs are not should.always have dip switch setting 5 set to ON for both controllers. Improper low -voltage wiring. illuminated. Check low -voltage wiring between pump and controller. Correct if necessary. See Section 3.2, Electrical Installation, in this manual. Controller displays °Pump Improper low -voltage wiring. not connected". Check low -voltage wiring between pump and controller..Correct if necessary. See Section 3.2, Electrical Installation, in this manual. Improper pump address set. Ensure pump dip switches 3 and 4 are set properly for the installation. Both should be OFF for use with Variable -Speed Controller or set to the proper address when connected to an AquaLink IRS controller, an AquaLink PDA, or an AquaLink Z4. See Section 3.3, Pump Dip Switch Settings, in this manual. Note: VS-FHP1.0 & VSFHP165JEP should always have dip switch setting 6 set to ON for both controllers. Page 20 I i\ Jandf Pro Series VS HoProTM Series Vadable•Spsed Pump I Installation & Operation Manual Fault message appears on Fault condition e controller display.. View fault messi to correct fault,( `1-888-647-4004 :1�Tr�.+2ICfM:4t yk•'�r�.lr,`�'3F',:.�:i` �w.Ki,�lru��-�3:;•�i?kiy�.'�,1�s-?sy4,�r`rt-t.7r7'Sr}:r�:"�.: ;r.,.., �:==Possi6l'e::C'auselSolution�?•�. � �-•, '��f =tr�� 'rr((_,,_�_, _- �` 'g:xw_l�^}.p r :•2.,lti�tr`-.t ,,,'i ^ .'^F.� �+:^L.. a�!;�.. r• +,.�:.:.^-K:e.-:.flL7�.�-1'�..•:lti=Jw: �43�vi�n �..:r�"*�.•7�pp•`s+-rL:-r.�:^.-.lzT�i'.��.a.y ��r:. Its. D on controller and correct fault before proceeding. If unsure how iiact Zodiac Technical Support at 800.822.7933. In Canada, call A CAUTION This pump must be serviced by a professional service technician qualified iri pool/spa installation. The following procedures must be followed exactly. Improper installation *and/or operatiori.can create dangerous electrical hazards, which can cause high voltages to run through the electrical system: This can cause property damage, serious personal injury, and/or death. Improper installation and/or operation will void the warranty. Blocked Impeller . A WARNING Before servicing the pump, switch off the circuit breakers at the' -power source.'Severe personal injury or death may occur if the pump starts while your hand is inside the pump. I. Turn off the pump. Switch off the circuit breakerto'the pump motor. 2. Remove the lid and basket. . 3. Look inside the pump f 4. Replace or -debris. Remove any debris found inside. the basket and lid. 5. Switch on the circuit breaker to the pump motor. 6. Turn on the pump, and see if the problem is solved. 7. If the impeller is still blocked with debris and it is not, possible to remove the'debris using Steps 2 through 4, the pump will need to be disassembled in order to, access the inlet and outlet of the impeller. 1 J Jandy° Pro Series VS RoProym Series Variable -Speed Pump I Installation & Operation Manual Page 21 Section 7. Product Specifications and Technical Data 7.1 Replacement Parts List and Exploded View To order or purchase parts for Zodiac® pumps, contact your nearest Zodiac dealer. If the Zodiac dealer cannot supply you with what you need, contact Zodiac Technical Support at 1.800.8223933, or send an e-mail message to productsupport@zodiac.com. In Canada, 1-888-6474004, customerservice PSC@zodiac.com -- ---Key - 1 --- - -- - No. _.. _--- ---- --- - - - - ---- -- -- Description Order Part No. 1 Motor, Drive, VS-FHP2.0 & VSFHP270AUT R0562201 1 Motor, Drive, VS-FHP1.0, VSFHP165JEP i R0571000 1 Motor, Drive, VSFHP165AUT R0670400 2 Backplate, (Backplate w/Hardware, Backplate O-ring & Mechanical Seal) R0479500 3 Impeller, (Impeller, Screw W/O -ring), VS-FHP2.0 R0479605 3 Impeller, (Impeller, Screw w/O-ring); VS-FHP1.0 R0479603 4 Diffuser, (Diffuser w/O-ring, Hardware & Backplate 0-ring) R0479701 5 Mechanical Seal, Carbon and Ceramic (1i Set) R0479400 6 Pump Body, (Body and Backplate O-ring) R0479800 7 Motor Mounting Foot I R047990D 8 Lid w/Locking Ring, (Lid w/Locking Ring & Lid 0-ring) R0480000 9 Pump Debris Filter Basket R0480100 10 Drain Plug w/ O-ring (Set of 2) R0446000 11 Tail Piece, 0-ring & Union Nut (Set of 2), R0327301 12 Lid O-ring R0480200 13 Backplate O-ring R0480300 14 Tailpiece 0-ring (Set of 2) R0337601 15 Diffuser/Impeller Hardware (Diffuser O-ring, Screws (2), Self Sealing Screw) R0480400 16 Backplate Hardware (Backplate Hardware & Backplate O-ring) R0480500 17 Motor Hardware Kit R0446700 18 Pump Base Kit R0486700. 19 Cover Fan, GEN 11 Replacement Kit (Hardware, Cover) R0562400 20 Hardware Speed Drive, GEN 11 R0662500 21 Connector, Speed Drive, VS-FHP Pump (4-Ain Connector) R0660900 22 Cable, R8485, Replacement Kit R0535100 23 Screw w/O-Ring R0515400 24 Cover, Large,, Speed Drive w/Gasket, , GEN 11 R0562300 25 Base Spacer, FHP, VS-FHP, Replacement Kit, R0546400 26 Data Cable, Feed Thru R0501100 27 User Interface Kit, Variable -Speed Pumps JEP-R 28 Cover, Controller, VS-FHP 1.0 R0571500 _ 29 Fan Cover,3S-F_HP_1.0 R057_1300 30 Access Cover, VS-FHP1.0 R0571400 31 User Interface Screws, VS-FHP1.0 R0571600 32 Conduit Fitting, 112 NPT VS-FHP1.0 R0501101 33 RearAccess'Cover Screw, VS-FHP1.0 R058760D i Page 22 Jandy® Pro Series VS FloPro7m Series Vadabl"peed Pump I Instal(allon & Operation Manual 7.2 Exploded Views I 8 VS-FHP2:O; VSFHP270AUT & VSFHP270JEP Motor (110562201) R0670400 ii 10 ' 16 (Qty 6) 14 . t ' A7- 2, 51` � 15,23 24 \ 3 . 2, 3, 4,13 2 L1 (Qty4) 19 i7 (Qty 4) 19 (Qty 3) (Qry 4) *25 Optional 7 *18 Optional 28 31 (Qty 6) 33 j I 30 27 21 . 32 29 i II , I I 1-VS-FHP10 &VSFHP165JEP Motor (110571000) ii .r\ 6 4,15 4 (Qty 2) 15 (Qty.2) 1-VSFHP165AUT Motor —J (110670400) Figure 16. VS FloPro Series Pumps Exploded View JandyO Pro Series VS RAW" Series Vadable-Speed Pump I Installaft & Operation Manual —.JddM3MWPage 23 7.3 Performance Curves Jan4y Prb Series VS HoPro Series Pump, VS-FHP1.0, VSFHP166AUT & VSFHP1663EP Performance Curves 100 43 39 70 60 28 u .9 34 i RP1 2 93 50 22 0, EO ISS 40, 1 -17 50 RF A C 30o- 20- 9 14 a- -�— a 0 10 20 30 40 50 SO 70 80 SD 100 110 120 130 140 160 160 170 lea 190 . 200 FlowRate, Gallons Per Minute, (GPM) Jafidy P I ro Series VS HoPro Series Pump VS-FHP2.0, VSFHP270AUT & VSFHP270JEP Performance Curves 9 4 .3 .2 70 SO. 1450q n V .22 40, )air 17 30. PIT 20 10 I 001P .4 600 00 M "w QU Ou lu du UU 100 110 120 130 140 150 160 170 ISO 190 200 Flow Rate, Gallons Per Minute, (GPM) 7.4 Physical and Operational SpecificatioOS; Specifications 5 7 ~ VAC 1,600W 2-2% 46 lbs. t 64 cm (25.2") VS-FHP1.0. VSFHP165AUT & 1.0 VSFHP166JEP .2$0 VS-FHP2.0. VSFHP270AUT & 2.0 230 VAC 2,400 W 2Y, - 311 58 lbs. 69 cm M (27.2! ) . 7.4.2 Dimensions NOTE When installing a pump, leave a minimum of two (2) feet (30 crn) of clearance above the.pump for removal ofthe strainer basket. 641 mm 25 W 283 mm 254 mm 11,/a" 10" I . Attached JEP-R Enclosure er-. P1.0 Models only) - _ I 324 mm 12Ile 197 mm I 7%". I _ 165 r I 276 mm Bolt Holes, to Front Edge of.Union Centerto Center Cen ter of Bolt Holes Figure 17. VS-FHP1.0 & VSFHP16SAUT Dimensions ' 691 nm I .27 WW 283 mm r_2510mm� � I 11118" f, 1-166 nun 6112" 276 mm 1o7I8" Bolt Holes, Center to Center Front Edge of Union to Center of Bolt Holes . I - Figure 18. VS-FHP2.0 & VSFHP270AUT DimensionsULLISTED f CONFORM y � CONFORMSTO Zodiac Pool Systems, Inc. SOT 2620 Commerce Way, Viista, CA92081 ULST01081 1.800.822.7933 ( www2oEr1acPoo1Systems.com ' Zodiac Pool Systems Canada, Inc. 2115 South Service Road West,Unit 3 Oakville (ON) l6L 5W2 Intertek I Cerrffiedto CAWCSAC222" No:10a +1(888) 6474004 www2od1acPao18ystems ca. ZODM C 8 Is a R91S IeV Wema*ofZodlacfnlei naCiona1,SAS. U,usadunderlicense. A11Wewftrefe=wdhe;dh are theprop*offhefrrespective owners: O20i5ZoaacPaot4staim, rna N8920400REvg w