HomeMy WebLinkAboutAPPLICATION ENGINEERINGRed I I APPLICATION ENGINEERING FOR HEATING AND COOLING PALM HARBOR HOMES - PLANT #6/#9 605 S. Frontage Road Plant City, FL 33566 TAIR OPTAIR HANDLER PREP Manufacturers Model #: T3626D HVAC System Type: OVERHEAD GRAD FLEX FOF UP-FLOW (SPLIT A/C) Prepared By LaSalle Air Systems aWO10 (Method & Output C 2009) All rights reserved: this information proprietary to LaSalle Bristol Co. a clie i t ts. Calculations on this page are based on design parameters set forth in ASHRAE and ACCA Manuals J and D. Design calculations are based on worst case orientation. Room loads may, vary based on actual conditions. ENTIRE HOUSE VALUES - DESIGN ZONE: 1 (HUD) I COOLING LOAD: 45,539 Btuh based on outside temp of I 97 ° F (36 C) with inside temp reduced to 75 ° F (23 C) HEATING LOAD: 53,758 Btuh based on outside temp of 10 ° F (-13 C) with inside temp raised to 70 ° F (21 C) OVERALL HEAT LOSS COEFFICIENT: 0.113 I CONSTRUCTION DETAILS & U FACTORS: (11-13-30) I TOTAL FLOOR AREA: 1680.00 SJ. TRUE OUTSIDE PERIMETER: 172.00 ft LOW CEILING HEIGHT: 108 in. HIGH CEILING HEIGHT: 108 in. NET WALL AREA 1288.25 &1. ROOF: 0.033 FLOOR DUCTS (U): 0 TOTAL Sid window 199.75 s.f. WALLS: 0.088 ATTIC DUCTS (U): 0.238 TOTAL S.G.D. 40.00 51 FLOOR: M076 EXT. DUCTS (U): 0.236 TOTAL Glass Block 0.00 s f. Sid winds LOBO ATTIC DUCT AREA: 69.359 s.f exposed TOTAL Skylite 0.00 s.f. S.G.D. 0.630 EXT. DUCT AREA: 0 s.f exposed TOTAL DOOR1 AREA: 20.00 s.f. Glass Bic 0.420 PEOPLE: 4 TOTAL DOOR2 AREA' 0.00 S.f. Skylite 0.790 FIREPLACES., 0 WINDOW % OF FLOOR 14.27 % DOOR1: 0.480 DUCT GAIN: 3984 Btuh WINDOW % OF WALL 15,49 % DOOR2: 0.670 DUCT LOSS: 4237 Btuh Mech. Ventilation per MHCSS 3280.103(b) : 59 cfm SUMMER INFILTR: 101.0 crin LATENT GAIN: 5765 Btuh Altitude: 250 111 WINTER INFILTR 2020 rim ROOM BY ROOM VALUES: I 1450.7 FPM, max velocity in trunk#: 2 Requirements based on actual house toads Coaling Air Healing Air Maximum AIC capacity without incorporating dud friction losses. Values for Values for 72 18 Kvi per MHCSS 3280.715 HEATING COOLING CFM I 4.6 ton unit Gas/Oil Elec Calibrated Blower Test ROOM NAME LOSS (Btu) GAIN (Btu) DIST CFM Btuh CFM Btuh Btuh Btuh Living Room 13,323 14,665 541 460 14,301 460 17,497 15,975 14,W5 Bedroom #3 4,276 3,456 134 134 4,171 134 5,103 4.660 4,352 Bedroom #2 4,651 3.657 142 138 4.302 138 5.263 4,805 4.106 W.I.C. Z344 1,337 52 67 Z098 67 Z567 2,344 Z140 M.Bedroom 6,972 6,066 220 256 7,965 256 9.745 8,898 7,979 M. Bath 4,479 3,052. 119 141 4,371 141 5.347 4,882 4,560 Utility 3,491 1,975 77 74 Z296 74 2,809, 2,564 2,367 Bath#1 1,878 1,167 46 71 2,206 71 2,699 2,465 2,259 Mchen 4.750 Z764 107 123 3,824 123 4,678 4,272 3,985 Dining Room 7.595 7,401 281 239 7,430 239 9,091 8.300 6,981 TOTALS 53,758 45,539 1.720 11704 52,963 1,704 64,800 59,165 53,285