Loading...
HomeMy WebLinkAboutAPPLICATION ENGINEERING1 APPLICATION ENGINEERING FOR HEATING AND COOLING PALM HARBOR HOMES PLANT 6/9 605 S. Frontage Rd.. Plant City, FL 33566 Manufacturer's Mode( #.-340-LS30592A HVAC System Type: OVERHEAD GRAD FLEX I AR rights reserved- this information proprietary to LaSalle Bristol Cc Calculations on fhis page are based on design standards ad krfh i for best distributbn based on Manual T Design tabulations are be ENTIRE HOUSE VALUES - DESIGN ZONE: 1 COOLING LOAD: 33,692 Btuh for Outside HEATING LOAD: 40,985 Btuh based on outside OVERALL HEAT LOSS COEFFICIENT: 0.115 /SHGC Total Cond. Floor Area: 1287.00 s.f. TRUE Ou Level 1 Ceiling: 96to 114 in. Level 2 Ceiling: Primary Wall Area: 1175.50 s.f. (Net) Dark Rool Secondary Wall Area: 0.00 s.f. (Net) Prim Wall TOTAL Std window 87.50 s.f. Sec Wall TOTAL Shaded Window 50.00 s.f. Exp Floor TOTAL Glass Block 0.00 s.f. Std winds TOTALSkylde 0.00 sf. Shaded TOTAL Doorl Area: 60.00 s.f. Glass Bic TOTAL Door2 Area: 0.00 s.f. Skyl to All Glass % of Floor. 10.68 % Door 1:. AD Glass % of Wall: 10.01 % Door 2: Mach. Ventilation per MHCSS 3280.103(b) : 50 LATENT GAIN: 4613 Btuh Attitude: ROOM BY ROOM VALUES: Heat Exiting Furnace: 102 deg A/C 6dting : 49. deg Actual heating and cooling required in each room and flow set to maximum of either heating or cooling HEATING COOLING CFM ROOM NAME LOSS (Btu) GAIN (Btu) DIST Living Room c 8,545 7,681 277 Dining c _ 3,977 4,510 162 Kitchen h 2,977 1,939 82 Entry h 2.398 1.490 66 Den h 4.541 3,038 125 Bedroom #2 c 4,688 3,962 140. Hall c 1,401 856 42 Bath #1 h 1,192 774 33 WIC h 1,578 1,005 43 M. Bath h 1,402 906 39 M. Bedroom c 8,286 7,431 248 AS O NNV39 UP -FLOW (SPLIT A/C) PALM HARBOR HOMES - PLANT 619 ASHRAE and ACCA Manuals JRev 8 2 and D Rev 1.1. System registers are bcated ed an worst case orientation. Room loads may vary based on actual conditions. 30N Latitude 95 ° F (35 C)/ 47%and Inside reduced to 75 ° F (23 C)/50% 10 ° F (43 C) with inside temp raised to 72 ° F (22 C) Crawlspace is not heated by the primary air handier. : (11+Non-ins Rim-11-22) lo Perimeter. 166.00 s ft to 0 in. Level 3 Ceiling., 0to 0 in. l: 0.043 Net Roof Area (less ducts): ): 0.163 FLOOR DUCTS (U): 0.052 ATTIC DUCTS (U): 0.067 EXT. DUCTS (U): .060 /'0.86 ATTICDUCTAREA: .060 10.05 EXT. DUCTAREA: 1.63010.51 PEOPLE: 3 1.420 10.34 FIREPLACES_ 1.480 DUCT GAIN: @ Average 1.670 DUCT LOSS: n Summer Infi tr (7.5 mph): 40 It Winter Infiltration (15 mph): Cooling Air Values for 3 ton unit CFM , Btuh 279 8,091 165 4,794 74 2,136 67 1.928 129 3,731 139 4,016 50 1,461 47 1,363 52. 1,496 239 6,931 TOTALS 40,985 33,592 1,257 1,241 35,947 Heating Air Values for 50 12.5 KW 90 % Gas/Oil Elec CFM Btuh E Btuh .264 10,114 9,585 156 5,992 5,679 70 2,670 2,530 63 2,410 2.284 122. 4.664 4,421 131 5,021 4,758 48 1,827 1.731 44 1,703 1,614 49 1,870 1,773 226 8,664 8,212 1,173 44,934 42,587 1170.6 s.f. Na 0.167 0.125 198.53 s.f. exposed 0 s.f. exposed 3420 Btuh Total Appliances 0 3452 Btuh @ 93 TD/ 48 TD 5020 Btuh @ 102 TD 44.8 . cfm 84.5 cirri @ Average 766.7 FPM, max velocity in trunk #: 2 0.21 Max pressure at A/H Maximum A/C capacity per MHCSS 3280.715 Calibrated Blower Test Btuh (aft adl) 10,216 6.085 2.719 2,455 4,749 5,098 1,861 1,735 1,905 8,798 45,620