Loading...
HomeMy WebLinkAboutKassawat rev sheetsDiagonal bracing to be 2" x 4" to span 8'-0" from gable ei nailed to each truss 2" x 4" bracing to Sr 8'-0" from gable end each truss with (2) IC See typical wall sectu construction C;/4BLE ENDW/4 LL DET/4 Oakridge shingles FLU 1004.1 nailed with typical 1 1/2" ring shank nails - see approval for all spacings, laps and edge distances per product approval with 5 5/8" exposure through 301b felt on 19/32" CDX plywood nailed to trusses per roof sheeting attachment diagram on roof plan Galt' -Alum Metal drip on I" x 3" Beveled Drip or 2" x 8" Fascia. 1/2" Dense glass screwed to truss webbing with 410 SS screws at 6" o.c. field and edges finished with Trowel on stucco finish per manufacturers recomendations Strap beams to columns using Simpson HETA 20 at each beam end Column C-4 grade Beam B2 19/32" CDX plywood sheeting nailed per roof sheeting attachment detail on roof plan sheet Soffit and fascia - see typical section for exact details 2" x 4" sub -fascia 1/8" thick light textured stucco over paper backed wire lath nailed to substrate through one layer of 15 lb felt using 8d nails. Substrate to be 19/32" CDX Plywood nailed at 6" o.c. in field and edges with IOd ring shank nails into studs. ClarkDietrich XJ15 Double-J expanded flange galvanized control o nt at to pl wood using d ring shank nails ( ) in each corner and at 16" o.c. thereafter with min. I" penetration into studs L (12 NTS Girder Truss i4- ,4- 3 1/2" x 3 1/2" x 1/4" thick steel column 10" x 10" x 5/8" thick base plate with (4) 5/8" dia. x 8" A.B. preset in concrete slab See gable end detail for bracing notes Trusses at 24" o.c. see shop drawings by others 4 3/4" wide x 12" high x 8" long x 5/8" thick steel column cap prewelded to steel column. Provide 1/8" ilia, predrilled hole for (3) 6/8" dia. thrubolts. /ADJUST CAP WIDTH AS NEEDED TO MATCH GIRDER THICKNESS VERIFY WITH TRUSS SHOP DRAWINGS PRIOR TO FABRICATION -O' T.O.B. Tgplcal Steel Column Detall A.F.F. MAX. UPLIFT = 6,000 Ibs MAX. GRAVITY = 10,000 lbs 1/2" dense glass attached to bottom chord using 410 x 2" SS screws at 6" o.c. field and edges and finished with trowel on stucco finish per manufacturers recomendations Beam and column show beyond 4" concrete slab with fibermesh OR "x6" #10/10 WWM on 6 mil Visqueen over clean compacted termite treated fill II II F-24 S action at E ntrq F orch Scale 3/4" = 1'-0 it 3 1/2" x 3 1/2" x 1/4" thick steel column 5/8" dia. x 8" a.b. preset in concrete slab � 1 10" x 10" x 5/8" thick base plate prewelded to column Base Deta11 Secondary Pour 14" x 14" square to recess bolts Wood truss bottom chord 26 ga, top track screwed to studs using (2) Type 'IS" screws each side of each stud Attach to trusses using (2) #8 screws at 48" o.c. max CF Q, 3 %8" 26 ga. G.I. metal stud blocking at mid -span of studs a `o 0 s n R m \1/2" drywall s 3 %8" 26 ga. G.I. metal stud Q) at W' o.c. > 6- 26ga bottom track screwed to studs +using (2) Type "S" screws each side of each stud Typical base INTERIOR WALL SECTION nts nts nts Oakridge shingles FLU 1004.1 nailed with typical 1 1/2" ring shank nails - see approval for all spacings, laps and edge distances per product approval with 5 5/8" exposure through 301b felt on 19/32" CDX plywood nailed to trusses per roof sheeting attachment diagram on roof plan 12 \ 6 SLOPE Simpson HTS strap at each truss supporting Max. 1450 Ibs, uplift (24) IOd x 1 1/2" nails in each strap Galt' -Alum Metal drip on I" x 3" Beveled Drip on 2" x 8" Fascia. 5/8" thick light textured trowel on stucco finish applied to 1/2" dense glass screwed to soffit framing using 1*10 x 2" SS screws at 6" o.c. field and edges Hang beams on columns using Simpson MBHA 5.56/11.88 with (1) 3/4" did. ATR top and face with min. 7 embedment set in Simpson ET Epoxy Tie Adhesive grade Trusses at 24" o.c. see shop drawings by others II'-0" T.O.B. A.F.F. Beam B2 Column C-1 Im 1/2" dense glass attached to bottom chord using 410 x 2" SS screws at 6" o.c. field and edges and finished with trowel on stucco finish per manufacturers recomendations 4" concrete slab with fibermesh OR (."x(." 11:10/10 WWM on 6 and Visqueen over clean compacted termite treated fill U. i l l l I I III III III I I I ���::���.���• � i t�H---���f---L r - II�� _ II F-36 S &ction at Entry F�orch Scale : 3/4" = 1'-0" Oakridge shingles FLU 1004.1 nailed with typical 1 1/2" ring shank nails - see approval for all spacings, laps and edge distances per product approval with 5 5/8" exposure through 301b felt on 19/32" CDX plywood nailed to trusses per roof sheeting attachment diagram on roof plan Simpson HETA 20 or equal hurricane anchor at each truss with (10) IOd x 1 1/2" nails ( 24" o.c.) supporting Maxim 1810lbs. uplift Galt' -Alum Metal drip on I" x 4" Drip on _ I" x 8" Fascia on `o 2" x C Sub -Fascia 4680 square f t roof / 150 = 31.2 sq. feet cont. 2" vent 5/8" thick stucco on 3/8" hi -rib lath attached to horizontal and vertical wood framing with nails or staples to provide no less than 1-3/4" penetration into horizontal wood framing and 3/4" penetration w/cont 2" wide screen vent 5/8" thick light textured stucco on typical concrete block construction 45 bar vert. w/ 30" overlap at each filled cell 12 PRE-ENGINEERED TRUSSES 6 at 24"o.c. TYPICAL �( shop drawings by manufacturer ) R- 3 8 BLOWN IN INSULATION base board Grade K51 'o1!71!;jot111 fz� I I I I k:=H TYPIC,4L SECTION 5/8" drywall with smooth finish 1/2" drywall over6FBVC. strips at 16" o.c. foil insulation on typic walls All drywall is per and Shall meet all pertaining ASTM codes. Mortar to be Type "1"i" only. Provide Dur-O-Rock at air wet areas (ex. showers, tubs etc...) Fill cell with concrete and (1) 45 bar vert. (typical). Max. spacing shall not exceed 32" unless otherwise noted see foundation plan notes for spacing at openings 4" concrete slab with fibermesh OR 6"x6" #10/10 WWM on 6 mil Visqueen over —clean compacted termite treated fill Scale 1/2" Digitally signed . by Daniel R. Daniel R Braden e n Date: 2022.03.15 09:35:24-04'00' ,11 f� O _ � N 00 0 dd 4-1 t � .. •• U N __ —d w 00 2 O � = U LE 10 N N 7t 4�W U C) C�3 N m W � k) OO <�Z W OD 0) " O OD NN� < 06� < - rr L < I z NN It O � ~ ( rr� a�- Q� U -Q �3 m W ii x —1 fy 1) v J (f DATE DRAWN 10-18-21 DRAWN BY: D.R.B. T.E.R.f= . CHECKED BY: i� MODEL: CUST01"I SERENITY I --I SHEET D — 2 W Ili OF 8. �M JOB NUMBER: w 21-2-4,4 .0gfL R. BRAD ®® 1` e AR 9770 o�9 �. Go° C)° ° °al