Loading...
HomeMy WebLinkAboutHD PERMIT FLOORl■nwil gum ° BEIDROOM #2 00 10'-O" A.F.F rlt ° Flat Carling SPA Pam Cn Water Pam ° j�ilE��11 { 1�I I N MA ------------- I I I a I I i 0 i I i I I I i ------------� I I I I I I I O I I i I i i i I I B I I I i i i i I I I ------------� o N n 5 shelves S PANTRY i r22• x 36;, (4tua Acc J with hghi. SIG«3� ` r► -4- i STUDY °_ 10'-0" A.F.FA-,, Flat Ceding 10'-0° -G" -L 4'-10" C -4" e..'- 24" 1'-8" COVERED PORCH Q ivl Coffer Ceding 's­JIF 8'-8" 01 Ceiling. 24". C-2 ill I 92 IAbo�c@� ii it rtue Auld with light i I .1 I pt H.S. L YI s C x TYPICAL NOTES: SCALE 1/41' 1'-00, 1. Contractor to verifg ALL notes and dimensions prior to proceeding with work. 2. Contractor to STRICTLY enforce ALL OSHA Requirements. 3. ALL Lumber to be used as Beam, Rafters, etc... to have a minimum 1,400 P.S.C. fiber stress. 4. No dissimilar metals to touch. 5. ALL Concrete used for slabs shall be min. 3000 PSi concrete, and ALL Concrete used for vertical filled cells, continuous. tie beams etc., to shall be min. 3,000 F.S.I. concrete and/or 4,000 P.S.C. grout mix L. Drywall at ceilings shall be leveled and attached to bottom chord of trusses with screws. 1. ALL wood in contact with concrete shall be pressure treated. S. ALL wall dimensions are nominal and not finished wall or stud dimensions. 9. ALL plumbing fixtures to be low flow. 10. Contractor to Provide Pan i Drain at water heater in accordance with the Florida Plumbing Code current edition. iI. Contractor to Provide a 2'-8" wide door at one bathroom for handicap accessibility requirements. 12. Lowest finished floor to be set bg Governing Building Department survegor to set in field. 13. Separation between residence and garage shall be per FBC R309.1 and R309.2 14. Door between garage and residence shall be 1-3/8" solid wood - 20 min. fire rated 15. The Garage shall be separated from residence and the attic area bg 5/8" type "X'" drgwall applied to garage wall. WALL SYMBOL LEGEND O.C. for walls up to 10'-0"* high. For 10 -0 a Space inspection 32" o.c. for walls is required by ang up to 15'-0"* licensed structural walls over special d enTneer to review and approve the vert. steel installafton in the footings, ® ° in the wall cavitg and into beam. v C s = 2" x 4" non-bearin stud walls - see sections. insulate L - a- wwitthh R-111 bastptasceast bathrooms il between A/C and 20- c00 9 V = r = 2" x 4" non -bearing stud wall at plumbing locations See floor plan for locations co COL Q C < dui ty , Square Footage Breakdown Window ;'ached L .a Total A/C Space = 2,931 sq. ft. � ® + Covered Porch Total = 334 5q. ft. �' o 0 Garage = 142 sq. ft. Under Roof Total = 4,021 sq. ft. Ule Mark Size Window Descri Lion I. 3'-1" x 5'-3" SINGLE HUNG 2. -5" x 5'-3" 5iNGLE HUNG - EGRESS 5. 3'-P x L'-4" SINGLE HUNG J. 4'-O" x 2'-O" FIXED GLASS S. L'-O' x 2°-0" FIXED GLASS 40-5. x 3'-2' SINGLE HUNG 1. 3'-0' x 3'-b" FIXED GLASS S. 2'-2" x 3'-2' SINGLE HUNG 9 2°-6" x 2'-t" CASEMENT ALL Windows to be white ESP aluminum windows with tint. Provide muntin's and structural mullions per elevations. See product approval chart for window manufacturer information. - ALL windows to withstand Pressures stated in Permit Information Box on these plans. - ALL windows in bathrooms to be tempered - ALL windows within 18" of finished floor to be tempered unless impact rated. - verifg all masonrg/rough opening sizes prior to ordering windows. Door Schedule Mark Size Door Descri tion A 3'-O" X e'-O" FOAM FILLED FIBERGLASS f. PANEL B 16'-0" X 8'-O" GARAGE DOOR C 9'-0" x 8'-0" GARAGE DOOR D 13) 3'-0' x 8'-0' SLIDING GLASS DOOR E (2) 3'-0" X 8'-O" SLIDING GLASS DOOR F 3'-0" X 8'-0" 20 MINUTE FIRE DOOR G 2'-8" X 8'-0" HOLLOW CORE INTERIOR DOOR H 5'-0" X 8'-0" BIPASS DOOR J 2'-8" X 8'-0" HOLLOW CORE INTERIOR DOOR K 5'-O' X ®°-®" Bi-FOLD DOOR L 4'-0" X W-0" BI-FOLD DOOR M 4'-0" X 8'-0' Bi-FOLD DOOR - ALL exterior doors including garage doors to withstand pressures stated in permit information box on these plans. - vei ifg all masonreg/rough opening sizes prior to ordering windows. - See product approval chart on these plans for exterior door manufacturer information (including garage door) - Provide one exit door (swing tgpe) that is 3'-0" wide minimum and one emergencg escape door (not shuttered). If escape door has gglazing then it must be impact resistant and shall NOT be thru garage. This mag be the same door if it meets both criteria listed above. r Digitally signed by Daniel R. / �°€3raden Dater2021.10.27 r 00 so Ctii M ar 00 � N h . a � H w 00 4 : o