Address: 12774 MARINER CT, PALM CITY , FL Permit Number. 1803-0244
4990 Permit Type: POOL/SPA - �S� 1r�-'--'-roed./
RESIDENTIAL Part D.44255o200r10W6
Job Description: CONSTRUCT GUNITE Number Units: I
SWIMMING POOL & SPA WITH VANISHI G subdwsfon: 4426M
Block
GE. Status: Pending toe Ise
Zoning: PLANNED UNIT Juduftu o: Cry
DEVELOPMENT
Date Applied: 3/8/2018
PERMIT REVIEW INFORMATION
Reviewed By Date Started Dade Sent Department Date Completed Review Type Review Status
ingraml 3/12/2018 3/122018 DOCUMENTS MISSING PENDING
angels 3202018 3J012018 ZONING REVIEW INCOMPLETE
JPIInc 323/2018 3012018 PLANS EXAMINER REVIEW INCOMPLETE
swartzell 3/9/2018 8/2018 3/9/2018 ENVIRONMENTAL REVIEW COMPLETE
PERMIT REVIEW COMMENTS INFORMATION
Review Type Compliance Comment Comment R
Date Date
PLANS EXAMINER 3/222018 1) PLANS REFERENCE THE 2014 FBC AND 2011 NEC, PLEASE UPDATE TO CURRENT CODE
REVIEW EDITION. (FAC 61 G20.1.001)
PLANS EXAMINER 3222018 2) PLEASE UPDATE PIPING SCHEMATIC TO REFLECT ACTUAL EQUIPMENT INCLUDING
REVIEW HEATERS. ([A] 107.2.1)
PLANS EXAMINER 3/222018 3) PLEASE UPDATE ELECTRICAL SCHEMATIC TO REFLECT ACTUAL EQUIPMENT INCLUDING
REVIEW HEATERS. ([A] 107.2.1)
PLANS EXAMINER 3/222018 4) PLEASE PROVIDE PRODUCT DATA FOR ALL EQUIPMENT, INCLUDING DOOR ALARMS, &
REVIEW SAFETY BARRIER. ([A] 107.2.1)
PLANS EXAMINER 3/222018 5) PLEASE PROVIDE LADDERS, STAIRS OR UNDERWATER BENCHES/SWIM-OUTS IN THE
REVIEW DEEP END. (454.2.18) .
PLANS EXAMINER 3222018 6) PLEASE PROVIDE DETAIL FOR THE AUTO FILL. ([A] 107.2.1)
REVIEW
PLANS EXAMINER 3222018 7) PLEASE PROVIDE SKIMMER, LOCATE ON PLAN. (454.2.21.2) I
REVIEW
PLANS EXAMINER 3/222018 8) PLEASE PROVIDE DETAIL FOR OVERFLOW. ([A] 107.2.1)
REVIEW
PLANS EXAMINER 3/22/2018 9) PLEASE VERIFY LOCATION OF THE TEMPERATURE RELIEF VALVES. (M2006.3)
REVIEW
PLANS EXAMINER 3/222018 10) PLEASE PROVIDE SOIL COMPACTION REQUIREMENTS ON PLANS. ([A] 107.2.1)
REVIEW
12
--- INSEECTIOtJ INFORMATION
i
Inspector Date Date Inspection Date of Scheduled Permit Inspector
Name Inspection Type Updated Scheduled Status Inspection By Number Comments
SHORING I 1803-0244
ANGLE OF REPOSE 1803-0244
MAIN DRAIN TEST 1803-0244
DRAIN TEST I 1803-0244
POOL STEEL & GROUND 1803-0244
POOL STEEL 1803-0244
COMPACTION TEST -
ORIGINAL - TURN INTO 1B03-0244
OFFICE
POOL UNDERGROUND PIPING 1803-0244
erinit Status Lookup 1803-0244
I