HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017
FLORIDA ENERGY EFF3WE>yC fl ODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Prdfessional Regulation - Residential Performance Method
p g es
Project Name: HIGHLANDS MODEL
Builder Name: CAL BUILDERS
Street: 5333 EMERSON AVE.
Permit Office: ST. LUCIE COUNTY
City, State, Zip: VERO BEACH, FL,
Permit Number:
Owner: BROIN PAULEY
Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, VERO_BEACH_MUNICIPAL ARPT
County:: Indian River (Florida Climate Zone 2 )
1. New construction or existing New (From Plans
9. Wall Types (1312.0 sqft.) Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior R=4.1 1072.00 ft2
b. Frame - Wood, Adjacent R=11.0 240.00 ft2
3. Number of units, if multiple family 1
c. N/A R= ft2
4. Number of Bedrooms 3
d. N/A R= ft2
5. Is this a worst case? No
10. Ceiling Types (1259.0 sqft.) Insulation Area
a. Under Attic (Vented) R=30.0 1259.00 ft2
6. Conditioned floor area above grade (ft2) 1259
b. N/A R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A R= ft2
11. Ducts R ft2
7. Windows(104.6 sqft-) Description Area
a. Sup: Attic, Ret: Attic, AH: Garage 6 275
a. U-Factor: Dbl, U=0.32 60.50 ft2
SHGC: SHGC=0.22
b. U-Factor: Dbl, U=0.35 33.33 ft2
12. Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit 24.0 SEER:16.00
c. U-Factor: Dbl, U=0.32 10.75 ft2
SHGC: SHGC=0.20
13. Heating systems kBtu/hr Efficiency
d. U-Factor: N/A fti
a. Electric Strip Heat 27.0 COPA.00
SHGC:
Area Weighted Average Overhang Depth: 1.000 ft.
Area Weighted Average SHGC: 0.228
14. Hot water systems
a. Electric Cap: 40 gallons
8. Floor Types (1259.0 sqft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 1259.00 ft1
b. Conservation features
b. N/A R= ft2
None
c. N/A R= fti
15. Credits CF, Pstat
Glass/Floor Area: 0.083 Total Proposed L
Modified Loads: 45.77 PASS
Total Baseline
Loads: 45.94
1
I hereby certify that the plans and specifications covered y
Review of the plans and Sr'4?�
this calculation are in compliance with the Florida Energy
O,iVE
specifications covered by this
Code.
calculation indicates compliance
`O
with the Florida Energy Code. mrn'�-" .:j`:�•'� .°;,
PREPAR Y:
Before construction is completed '" =
DATE:
this building will be inspected for k�
compliance with Section 553.908 * "'
'
fy pliance
I herebycertify that this be7=
Florida Statutes. 1,�
with the Florida Energy CDWEOWNER/AGE
T:
BUILDING OFFICIAL:
DATE: -
DATE:
i
- Compliance requires certification by the air handler unit manufacturer that the
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in acco
envelope leakage test report with envelope leakage no greater than 7.00 ACH50
I
4/16/2018 6:14 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1
JVhEff%[equires an ' , t
APR .• :,,3
Permitting Department
St. Lucie County, FL
ae 1 of 5
File Copy
FORM R405-2017
PROJECT
Title: HIGHLANDS MODEL
Bedrooms:
3
Address Type:
Street Address
Building Type: User
Conditioned
Area: 1259
Lot #
Owner Name: BROIN PAULEY
Total Stories:
1
Block/Subdivision:
# of Units: 1
Worst
Case: No
PlatBook:
builder Name: CAL BUILDERS
Rotate
�ngle: 0
Street:
5333 EMERSON AVE.
Permit Office: ST. LUCIE COUNTY
Cross
Ilyentilation: No
County:
Indian River
Jurisdiction: ST. LUCIE COUNTY
Whole
House Fan: No
City, State, Zip:
VERO BEACH,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
V
Design Temp
Int Design Temp Heating
Design Daily Temp
Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, VERO_BEACH_MUN FL_VERO_BEACH_MUNI
45
90
70
75 299
64
Medium
BLOCKS
Number Name
Area Volu
e
1 Entire House
1259 10336
SPACES
Number Name
Area Volume
Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 WIC
36 288
No
0
1 Yes
Yes
Yes
2 M BATH
67 536
No
0
1 Yes
Yes
Yes
3 MASTER BEDROO
208 1664
No
2
1
1 Yes
Yes
Yes
4 KITCHEN/DINING
288 2304
Yes
0
1 Yes
Yes
Yes
5 LIVING
264 2376
No
0
1 Yes
Yes
Yes
6 BEDROOM 3
158 1264
No
0
1
1 Yes
Yes
Yes
7 BATH 2
48 384
No
0
1 Yes
Yes
Yes
8 BEDROOM 2
156 1248
No
0
1
1 Yes
Yes
Yes
9 HALL
34 272
No
0
1 No
Yes
Yes
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
WIC 12 ft 0
36 ft2
_---
0 1
0
2 Slab -On -Grade Edge Insulatio
M BATH 13 ft 0
I
67 ft2
----
0 1
0
3 Slab -On -Grade Edge Insulatio
MASTER BEDRO 13 ft 0
208 ft2
----
0 1
0
4 Slab -On -Grade Edge Insulatio
i
KITCHEN/DININ; 18 ft 0
I
288 ft2
----
0 1
0
5 Slab -On -Grade Edge Insulatio
LIVING 18 ft 0
264 ft2
----
0 1
0
6 Slab -On -Grade Edge Insulatio
BEDROOM 3 26 ft 0
158 ft2
----
0 1
0
7 Slab -On -Grade Edge Insulatio
BATH 2 6 ft 0
48 ft2
----
0 1
0
1
4/16/2018 6:14 PM EnergyGauge® USA J FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017
FLOORS
#
Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio BEDROOM 2
28 ft 0
156 ft2
----
0
1
0
9 Slab -On -Grade Edge Insulatio HALL
1 ft 0
34 ft2
----
0
1
0
ROOF
/
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V
#
Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1
Gable or Shed Composition shingles 13614
ft2
262 ft2
Light
0.6
No
0.9
No
0
22.6
ATTIC
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
300
1259 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented) WIC
30
Blown
36 ft2
0.1
Wood
2
Under Attic (Vented) M BATH
30
Blown
67 ft2
0.1
Wood
3
Under Attic (Vented) MASTER MEMO 30
Blown
208 ft2
0.1
Wood
4
Under Attic (Vented) KITCHEN/DININ 30
Blown
288 ft2
0.1
Wood
5
Under Attic (Vented) LIVING
30
Blown
264 ft2
0.1
Wood
6
Under Attic (Vented) BEDROOM 3
30
Blown
158 ft2
0.1
Wood
7
Under Attic (Vented) BATH 2
30
Blown
48 ft2
0.1
Wood
8
Under Attic (Vented) BEDROOIM 2
30
Blown
156 ft2
0.1
Wood
9
Under Attic (Vented) HALT
II
30
Blown
34 ft2
0.1
Wood
WALLS
Ornt
Adjacent Space
10 Wall Type1
Cavity Width
Height
Sheathing Framing
Solar
Below
E
Exterior Concrete Block - Ext Insul WIC
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
2
S
Exterior Concrete Block - Ext Insul WIC
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
_ 3
N
Exterior Concrete Block - Ext InsulM BATH
4.1 1
0 8
0
8.0 ft2
0
0
0.6
0
4
E
Exterior Concrete Block - Ext InsulM BAT
4.1 11
0 8
0
88.0 ft2
0
0
0.6
0
5
S
Exterior Concrete Block - Ext InsulM BA IH
4.1 1
0 8
0
8.0 ft2
0
0
0.6
0
_ 6
S
Exterior Concrete Block - Ext InsMASTER BE
4.1 13
0 8
0
104.0 ft2
0
0
0.6
0
_ 7
S
Exterior Concrete Block - Ext Ins161TCHEN/DI
4.1 18
0 8
0
144.0 ft2
0
0
0.6
0
8
N
Exterior Concrete Block - Ext Insul LIVING
4.1 18
0 8
0
144.0 ft2
0
0
0.6
0
_ 9
S
Exterior Concrete Block - Ext InEEDROOM 3
4.1 12
0 8
0
96.0 ft2
0
0
0.6
0
10
W
Exterior Concrete Block - Ext InfiffDROOM 3
4.1 14
0 8
0
112.0 ft2
0
0
0.6
0
_ 11
W
Exterior Concrete Block - Ext Insul BATH
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
-12
N
I
Exterior Concrete Block - Ext InERffDROOM 2
4.1 12
0 8
0
96.0 ft2
0
0
0.6
0
_ 13
E
Exterior Concrete Block - Ext InfiffDROOM 2
4.1 3
0 8
0
24.0 ft2
0
0
0.6
0
14
W
I
Exterior Concrete Block - Ext InfiffDROOM 2
4.1 13
0 8
0
104.0 ft2
0
0
0.6
0
_15
N
Garage Frame - Wood WIC
11 30
8
240.0 ft2
0.23
0.6
0
4/16/2018 6:14 PM EnergyGauge® USA -; FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5
FORM R4(15-9(N7
DOORS
#
Ornt
Door Type Space
Storms U-Value Width
Ft In
Height
Ft In
Area
1
N
Insulated LIVING
None .39 3
6 8
20 ft2
•
Orientation shown
WINDOWS
is the entered, Proposed orientation.
#
Wall
Ornt ID Frame
Panes NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation
Int Shade
Screening
1
2
3
4
5
6
S 6 Vinyl
S 7 Vinyl
S 7 Vinyl
N 8 Vinyl
S 9 Vinyl
N 12 Vinyl
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
0.32 0.22 N 15.0 ft2 1 ft 0 in 1 ft 4 in
0.35 0.25 N 33.3 ft2 1 ft 0 in 1 ft 4 in
0.32 0.22 N 10.5 ft2 1 ft 0 in 1 ft 4 in
0.32 0.22 N 20.0 ft2 1 ft 0 in 1 ft 4 in
0.32 0.22 N 15.0 ft2 1 ft 0 in 1 ft 4 in
0.32 0.2 N 10.8 ft2 1 ft 0 in 1 ft 4 in
None
None
None
None
None
None
None
None
None
None
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
418ft2
418ft2
30ft 8ft
11
INFILTRATION
# Scope
Method
SLA
(;FM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000365
1205.9 66.2 124.5 .2739
7
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity
Block
Ducts
1
Electric Strip Heat/ None
COPA 27 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
Split
SEER: 16 24 kBtu/hr 720 cfm
0.8 1
sys#1
HOOT
WATER SYSTEM
#
System Type
SubType Location
EF Cap Use SetPnt
Conservation
1
Electric
None Garage
0.95 40 gal 60.9 gal 120 deg
None
SOLAR
HOT WATER SYSTEM
I
FSEC Collector
Cert # Company Name System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
I
I
I
4/16/2018 6:14 PM EnergyGauge@) USA - F1aRes2017 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017
DUCTS
/
--- Supply
--
--- Return
----
Air
CFM 25
CFM25
HVAC #
. V # Location R-Value
Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic 6
275 ft2
Attic
95 ftZ Default Leakage
Garage
(Default)
(Default)
1 1
'
TEMPERATURES
Programable Thermostat: Y
Ceiling
Fans:
Cooling[ ] Jan
Heatin[X] Jan
Feb
Feb
Mar
Mar
j
Apr
Apr
Jul
JunJul
Jun rl
May ri
X Au
Au
Se
Sep
rl
[ ]
[ ]Oct
Oct
Nov
Dec
Ventin [ ] Jan
Feb
X
X Mar
[X]
A r
Ma Jun Jul
May
Aug
Se
[X]
Oct
XNovDec
X Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
78
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78 78 78
78
78
78
78
78
78
PM
78
78
78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
4/16/2018 6:14 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5
1
2017 - AIR BARRIEeR AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
I
Project Name: HIGHLANDS MODEL Builder Name: CAL BUILDERS
Street: 5333 EMERSON AVE. Permit Office: ST. LUCIE COUNTY
City, State, Zip: VERO BEACH, FL, Permit Number:
Owner: BROIN PAULEY Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, VERO_BEACH_MUNICIPAL_ARPT
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with
Ceiling/attic
i
the insulation and any gaps in the air barrier shall be sealed.
The insulation in an dropped ceiling/soffit
y Pp g /soffit
Access openings, drop down stairs or knee wall doors to
shall be aligned with the air barrier.
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate
shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top
of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs
and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any
exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaced
shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping
joints taped.
shall be permanently attached to the crawlspace walls
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between thIe garage and conditioned spac
Bs.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind pdpong and wirong-
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes 'or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sp.r*n kler cover plates and walls or ceol*ngs-
a. ui awnwn, inspection or iog wars snan De in accordance with the provisions of ICC-400.
4/16/2018 6:14 PM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
4 i
FORM R405-2017
ENERGY
PERFORMANCE LEVEL
(EPL)
'
DIS�PLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* =
100
The lower the EnergyPerformance Index, the more efficient the home.
5333 EMERSON
AVE., VERO BEACH, FL,
1. New construction or existing
New (From Plans)
9. Wall Types
Insulation
Area
2. Single family or multiple family
Single-family
a. Concrete Block - Ext Insul, Exterior R=4.1
1072.00 ft2
b. Frame - Wood, Adjacent
R=11.0
240.00 ft2
3. Number of units, if multiple family
1
c. N/A
R=
ft2
4. Number of Bedrooms
3
d. N/A
R=
ft2
5. Is this a worst case?
No
10. Ceiling Types
Insulation
Area
a. Under Attic (Vented)
R=30.0
1259.00 ft2
6. Conditioned floor area (ft2)
1259
b. N/A
R=
ft2
7. Windows** Description
Area
c•
R=
ft2N/A
a. U-Factor: Dbl, U=0.32
I
60.50 ft2
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Garage
R ft2
6 275
SHGC: SHGC=0.22
b. U-Factor: Dbl, U=0.35
33.33 ft2
SHGC: SHGC=0.25
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.32
10.75 ft
a. Central Unit
24.0 SEER:16.00
SHGC: SHGC=0.20
d. U-Factor: N/A
ft2
SHGC:
13. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
1.000 ft.
a. Electric Strip Heat
27.0
COP:1.00
Area Weighted Average SHGC:
0:228
8. Floor Types Insulation
Area
14. Hot water systems
a. Slab -On -Grade Edge Insulation R=0.0 1259.00 ft2EF:
a. Electric
Cap:
40 gallons
b. N/A R=
ft2
0.95
c. N/A R=
ft2
b. Conservation features
None
15. Credits
CF, Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final ins Ion. Otherwise, a new EPL Display Card will be completed
based on installed Code molian eaWfes------%
Builder Signature:
Address of New H
Date: 4 -) 7 > / 8
City/FL Zip:
4D WBT�;
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I
4/16/2018 6:14 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1