Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFF3WE>yC fl ODE FOR BUILDING CONSTRUCTION Florida Department of Business and Prdfessional Regulation - Residential Performance Method p g es Project Name: HIGHLANDS MODEL Builder Name: CAL BUILDERS Street: 5333 EMERSON AVE. Permit Office: ST. LUCIE COUNTY City, State, Zip: VERO BEACH, FL, Permit Number: Owner: BROIN PAULEY Jurisdiction: ST. LUCIE COUNTY Design Location: FL, VERO_BEACH_MUNICIPAL ARPT County:: Indian River (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans 9. Wall Types (1312.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1072.00 ft2 b. Frame - Wood, Adjacent R=11.0 240.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1259.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1259.00 ft2 6. Conditioned floor area above grade (ft2) 1259 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(104.6 sqft-) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 275 a. U-Factor: Dbl, U=0.32 60.50 ft2 SHGC: SHGC=0.22 b. U-Factor: Dbl, U=0.35 33.33 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 24.0 SEER:16.00 c. U-Factor: Dbl, U=0.32 10.75 ft2 SHGC: SHGC=0.20 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A fti a. Electric Strip Heat 27.0 COPA.00 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.228 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1259.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1259.00 ft1 b. Conservation features b. N/A R= ft2 None c. N/A R= fti 15. Credits CF, Pstat Glass/Floor Area: 0.083 Total Proposed L Modified Loads: 45.77 PASS Total Baseline Loads: 45.94 1 I hereby certify that the plans and specifications covered y Review of the plans and Sr'4?� this calculation are in compliance with the Florida Energy O,iVE specifications covered by this Code. calculation indicates compliance `O with the Florida Energy Code. mrn'�-" .:j`:�•'� .°;, PREPAR Y: Before construction is completed '" = DATE: this building will be inspected for k� compliance with Section 553.908 * "' ' fy pliance I herebycertify that this be7= Florida Statutes. 1,� with the Florida Energy CDWEOWNER/AGE T: BUILDING OFFICIAL: DATE: - DATE: i - Compliance requires certification by the air handler unit manufacturer that the certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in acco envelope leakage test report with envelope leakage no greater than 7.00 ACH50 I 4/16/2018 6:14 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 JVhEff%[equires an ' , t APR .• :,,3 Permitting Department St. Lucie County, FL ae 1 of 5 File Copy FORM R405-2017 PROJECT Title: HIGHLANDS MODEL Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1259 Lot # Owner Name: BROIN PAULEY Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: builder Name: CAL BUILDERS Rotate �ngle: 0 Street: 5333 EMERSON AVE. Permit Office: ST. LUCIE COUNTY Cross Ilyentilation: No County: Indian River Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: VERO BEACH, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE V Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, VERO_BEACH_MUN FL_VERO_BEACH_MUNI 45 90 70 75 299 64 Medium BLOCKS Number Name Area Volu e 1 Entire House 1259 10336 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 WIC 36 288 No 0 1 Yes Yes Yes 2 M BATH 67 536 No 0 1 Yes Yes Yes 3 MASTER BEDROO 208 1664 No 2 1 1 Yes Yes Yes 4 KITCHEN/DINING 288 2304 Yes 0 1 Yes Yes Yes 5 LIVING 264 2376 No 0 1 Yes Yes Yes 6 BEDROOM 3 158 1264 No 0 1 1 Yes Yes Yes 7 BATH 2 48 384 No 0 1 Yes Yes Yes 8 BEDROOM 2 156 1248 No 0 1 1 Yes Yes Yes 9 HALL 34 272 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio WIC 12 ft 0 36 ft2 _--- 0 1 0 2 Slab -On -Grade Edge Insulatio M BATH 13 ft 0 I 67 ft2 ---- 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BEDRO 13 ft 0 208 ft2 ---- 0 1 0 4 Slab -On -Grade Edge Insulatio i KITCHEN/DININ; 18 ft 0 I 288 ft2 ---- 0 1 0 5 Slab -On -Grade Edge Insulatio LIVING 18 ft 0 264 ft2 ---- 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 3 26 ft 0 158 ft2 ---- 0 1 0 7 Slab -On -Grade Edge Insulatio BATH 2 6 ft 0 48 ft2 ---- 0 1 0 1 4/16/2018 6:14 PM EnergyGauge® USA J FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio BEDROOM 2 28 ft 0 156 ft2 ---- 0 1 0 9 Slab -On -Grade Edge Insulatio HALL 1 ft 0 34 ft2 ---- 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 13614 ft2 262 ft2 Light 0.6 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1259 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) WIC 30 Blown 36 ft2 0.1 Wood 2 Under Attic (Vented) M BATH 30 Blown 67 ft2 0.1 Wood 3 Under Attic (Vented) MASTER MEMO 30 Blown 208 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN/DININ 30 Blown 288 ft2 0.1 Wood 5 Under Attic (Vented) LIVING 30 Blown 264 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 3 30 Blown 158 ft2 0.1 Wood 7 Under Attic (Vented) BATH 2 30 Blown 48 ft2 0.1 Wood 8 Under Attic (Vented) BEDROOIM 2 30 Blown 156 ft2 0.1 Wood 9 Under Attic (Vented) HALT II 30 Blown 34 ft2 0.1 Wood WALLS Ornt Adjacent Space 10 Wall Type1 Cavity Width Height Sheathing Framing Solar Below E Exterior Concrete Block - Ext Insul WIC 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 2 S Exterior Concrete Block - Ext Insul WIC 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 _ 3 N Exterior Concrete Block - Ext InsulM BATH 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 4 E Exterior Concrete Block - Ext InsulM BAT 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 5 S Exterior Concrete Block - Ext InsulM BA IH 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 _ 6 S Exterior Concrete Block - Ext InsMASTER BE 4.1 13 0 8 0 104.0 ft2 0 0 0.6 0 _ 7 S Exterior Concrete Block - Ext Ins161TCHEN/DI 4.1 18 0 8 0 144.0 ft2 0 0 0.6 0 8 N Exterior Concrete Block - Ext Insul LIVING 4.1 18 0 8 0 144.0 ft2 0 0 0.6 0 _ 9 S Exterior Concrete Block - Ext InEEDROOM 3 4.1 12 0 8 0 96.0 ft2 0 0 0.6 0 10 W Exterior Concrete Block - Ext InfiffDROOM 3 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 _ 11 W Exterior Concrete Block - Ext Insul BATH 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 -12 N I Exterior Concrete Block - Ext InERffDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.6 0 _ 13 E Exterior Concrete Block - Ext InfiffDROOM 2 4.1 3 0 8 0 24.0 ft2 0 0 0.6 0 14 W I Exterior Concrete Block - Ext InfiffDROOM 2 4.1 13 0 8 0 104.0 ft2 0 0 0.6 0 _15 N Garage Frame - Wood WIC 11 30 8 240.0 ft2 0.23 0.6 0 4/16/2018 6:14 PM EnergyGauge® USA -; FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R4(15-9(N7 DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 N Insulated LIVING None .39 3 6 8 20 ft2 • Orientation shown WINDOWS is the entered, Proposed orientation. # Wall Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 2 3 4 5 6 S 6 Vinyl S 7 Vinyl S 7 Vinyl N 8 Vinyl S 9 Vinyl N 12 Vinyl Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes 0.32 0.22 N 15.0 ft2 1 ft 0 in 1 ft 4 in 0.35 0.25 N 33.3 ft2 1 ft 0 in 1 ft 4 in 0.32 0.22 N 10.5 ft2 1 ft 0 in 1 ft 4 in 0.32 0.22 N 20.0 ft2 1 ft 0 in 1 ft 4 in 0.32 0.22 N 15.0 ft2 1 ft 0 in 1 ft 4 in 0.32 0.2 N 10.8 ft2 1 ft 0 in 1 ft 4 in None None None None None None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 418ft2 418ft2 30ft 8ft 11 INFILTRATION # Scope Method SLA (;FM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000365 1205.9 66.2 124.5 .2739 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 24 kBtu/hr 720 cfm 0.8 1 sys#1 HOOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM I FSEC Collector Cert # Company Name System Model # Collector Model # Area Storage Volume FEF None None ft2 I I I 4/16/2018 6:14 PM EnergyGauge@) USA - F1aRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 DUCTS / --- Supply -- --- Return ---- Air CFM 25 CFM25 HVAC # . V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 275 ft2 Attic 95 ftZ Default Leakage Garage (Default) (Default) 1 1 ' TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling[ ] Jan Heatin[X] Jan Feb Feb Mar Mar j Apr Apr Jul JunJul Jun rl May ri X Au Au Se Sep rl [ ] [ ]Oct Oct Nov Dec Ventin [ ] Jan Feb X X Mar [X] A r Ma Jun Jul May Aug Se [X] Oct XNovDec X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/16/2018 6:14 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 1 2017 - AIR BARRIEeR AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA I Project Name: HIGHLANDS MODEL Builder Name: CAL BUILDERS Street: 5333 EMERSON AVE. Permit Office: ST. LUCIE COUNTY City, State, Zip: VERO BEACH, FL, Permit Number: Owner: BROIN PAULEY Jurisdiction: ST. LUCIE COUNTY Design Location: FL, VERO_BEACH_MUNICIPAL_ARPT COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with Ceiling/attic i the insulation and any gaps in the air barrier shall be sealed. The insulation in an dropped ceiling/soffit y Pp g /soffit Access openings, drop down stairs or knee wall doors to shall be aligned with the air barrier. unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaced shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between thIe garage and conditioned spac Bs. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind pdpong and wirong- Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes 'or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sp.r*n kler cover plates and walls or ceol*ngs- a. ui awnwn, inspection or iog wars snan De in accordance with the provisions of ICC-400. 4/16/2018 6:14 PM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 4 i FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) ' DIS�PLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. 5333 EMERSON AVE., VERO BEACH, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1072.00 ft2 b. Frame - Wood, Adjacent R=11.0 240.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=30.0 1259.00 ft2 6. Conditioned floor area (ft2) 1259 b. N/A R= ft2 7. Windows** Description Area c• R= ft2N/A a. U-Factor: Dbl, U=0.32 I 60.50 ft2 11. Ducts a. Sup: Attic, Ret: Attic, AH: Garage R ft2 6 275 SHGC: SHGC=0.22 b. U-Factor: Dbl, U=0.35 33.33 ft2 SHGC: SHGC=0.25 12. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.32 10.75 ft a. Central Unit 24.0 SEER:16.00 SHGC: SHGC=0.20 d. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 1.000 ft. a. Electric Strip Heat 27.0 COP:1.00 Area Weighted Average SHGC: 0:228 8. Floor Types Insulation Area 14. Hot water systems a. Slab -On -Grade Edge Insulation R=0.0 1259.00 ft2EF: a. Electric Cap: 40 gallons b. N/A R= ft2 0.95 c. N/A R= ft2 b. Conservation features None 15. Credits CF, Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final ins Ion. Otherwise, a new EPL Display Card will be completed based on installed Code molian eaWfes------% Builder Signature: Address of New H Date: 4 -) 7 > / 8 City/FL Zip: 4D WBT�; *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I 4/16/2018 6:14 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1