04 09 2018 Q Cubic volume of the conditio led spaced was not added to the plans.
(A) Cubic shown under key note on page
04/09/2018 (Q) Truss En gineering_signa ,ure. s a copy,_must beoriginal signature.
(A) Resubmitted signed and sealed in duplic; e o 04/24/2018.
','� � � ' �• ` ��� i I � furnish the manufacturer
%% / o si ned and sealed. Please fu
04/27/2018I(Q) Truss placement drawings are not g
truss placement drawings in duplicate reviewed-and_approved by the d+esign person on record in
accordance with"Chapter 8 Section R 0 subsection R8021.7:\ of the 2017 Florida residential'building
code.
(A) Signed, sealed , in duplicatedi on 04/30/2018
04/27/2018 (Q) Submitted documents were not reviewed and approved by the design professional in
charge. Please submit all documents and drawings in duplicated reviewed and approved by the design
person of record in accordance with Chi Ater 8 Section R802 subsection R802.17.1 of the 2017 Florida
Residential Building Code.
(A) Signed and sealed in the title block -, resubmitting in duplicate 04/30/2018.
04/27/2018 (Q) Truss Engineering and truss drawings specified that they are designed to the 2014
Florida Building Code. Please submit !corrected Truss Engineering and Truss Placement drawings
designed to the current codes. See Section 107 of the 2017 Florida Building Code.
(A) Submitting revised drawings for 2017 in duplicate
2020 Old Dixie Highway SE, Suite 6, Vero Beach, FL 32962 • Tel: 772.562.3715 • Fax: 772.562.7782 • Email: CALBuilderinc®aol.com
www.CALBuilderslnc.com
04/27/2018 (QA) A cover letter is required to beIsubmitted with any submitted documents addressing
the plans examiners comments No cover letter was submitted specifying the changes or documents
needed.
(A) Attached with submittal package in duplicate 04/30/2018
04/27/2018 (Q) Please see clouded notes in the design parameters for wind load compliance on
submitted page 2.0. Please show the soil density on the plans or submit a Geotechnical report with
recommendations for the new fill requirements. See Chapter 4 Section R401 of the 2017 Florida
Residential Code.
(A) The design parameters on page 'is called out for 2000 PSI and note 12 in foundation notes
calls out allowable soil bearing capacity of 200 PSF.
04/27/2018 (Q) Only page 2.0 was submitted! with the correct building code cycle. See pages 1.0 and
5.0. Please submit corrected drawings with t!he current code cycle. See section 107 of the 2017 Florida
Building Code.
(A) Submitting pages I and 5 in duplicate on 04/30/2018.
CAL Builder's Inc.
April 30, 2018
RE: Permit #1803-0756
BUILDERS
INCORPORATED
GENERAL 25ggB /IO CONTRACTOR
APR 3 0 9018
ST. Lucie County, Permitting
04/09/2018 (Q) Cubic volume of the conditioned spaced was not added to the plans.
(A) Cubic shown under key note on page 3.
04/09/2018 (Q) Truss Engineering-signature=is a copy,; must be original signat�ure_�
(A)) Resubmitted signed and sealed in du/plicate on 04/24/2018.
i remot signed`'arid sealed. (Please furnish the manufacturer
04/27/20'8 �(Q) Truss placement drawings a
truss placement drawings in duplicate reviewed_and approved by the design person on record �n
accordance\'with Chapter 8 Section R802%subsection R802.1.1:1 of the120117 Florida residential./building
code. �' ---� �� ��\ ` '\ J ��I --- —IL
(A) Signed, sealed, in duplicated on 04/30/2018
04/27/2018 (Q) Submitted documents were not reviewed and approved by the design professional in
charge. Please submit all documents and drawings in duplicated reviewed and approved by the design
person of record in accordance with Chapter 8 Section R802 subsection R802.17.1 of the 2017 Florida
Residential Building Code.
(A) Signed and sealed in the title block -, resubmitting in duplicate 04/30/2018.
04/27/2018 (Q) Truss Engineering and truss drawings specified that they are designed to the 2014
Florida Building Code. Please submit corrected Truss Engineering and Truss Placement drawings
designed to the current codes. See Section 107 of the 2017 Florida Building Code.
(A) Submitting revised drawings for 2017 in duplicate
2020 Old Dixie Highway SE, Suite 6, Vero Beach, FL 32962 • Tel: 772.562.3715 • Fax: 772.562.7782 • Email: CALBuilderInc®aol.com
www.CALBuildersInc.com
04/27/2018 (QA) A cover letter is required to be submitted with any submitted documents addressing
the plans examiners comments No cover letter was submitted specifying the changes or documents
needed.
(A) Attached with submittal package in duplicate 04/30/2018
04/27/2018 (Q) Please see clouded notes in the design parameters for wind load compliance on
submitted page 2.0. Please show the soil densilt on the plans or submit a Geotechnical report with
recommendations for the new fill requirements See Chapter 4 Section R401 of the 2017 Florida
Residential Code.
(A) The design parameters on page 2 is called out for 2000 PSI and note 12 in foundation notes
calls out allowable soil bearing capacity of 200 PSF.
04/27/2018 (Q) Only page 2.0 was submitted
5.0. Please submit corrected drawings with t
Building Code.
ng pages I and 5 in duplicate on 04/30/2018.
CAL Builder's Inc.
th the correct building code cycle. See pages 1.0 and
current code cycle. See section 107 of the 2017 Florida
.Af'wti i
Planning & Development Services
Building Si Code Regulation Division,
2300 Virginia Avenue
Fort Pierce; FL. 34982
Phone:(772)462.2172 Fax:(772)462.6443
PROPERTY INFORMATION
Address: 5333 Emerson Ave
City / State / Zip: Fort Pierce, FI 34951-1608
Parcel M 1310-441-0021-000/3
Zoning: AG-1
EW COMMENTS
1
Owner(s):
Brion Pauley
Jurisdiction: SAINT LUCIE COUNTY
Lot#:
APPLICATION INFORMATION
Permit Number: 1803-0756 Stories:
Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS)
CONTRACTOR INFORMATION
Contractor Name: Carl A Lachnitt
Business Name: Cal Builders Inc
Business Addr: 2020 Old Dixie Hwy Se Ste 6
City / State / Zip: Vero Beach, FI 32962
REVIEWS AND COMMENTS
Review Tvae Status
ADDRESSING ASSIGNMENT COMPLETE
Comment:
DOCUMENTS MISSING
3/27/2018 Comment:
ENVIRONMENTAL REVIEW
Comment:
FRONT COUNTER REVIEW
Comment:
PE REVIEW COMMENTS (2)
Comment:
4/9/2018
Comment:
4/27/2018
Comment:
4/27/2018
Block:
Automatic Sprinkler System? No
Fax Number: 772-562-7782
Email: Calbuilderinc@Aol.Com
Revie� Date Started Date Completed
Lori Bender 4/212018 41212018
PENDING Lashahna Ingram
NEEDS NOC I
COMPLETE Lynn Swartzel 3/28/2018 3/30/2018
COMPLETE Lasiahna Ingram 3/27/2018 3127/2018
i
I
INCOMPLETE William Durden 4/27/2018
Date Released
4/2/2018
3/30/2018
3/27/2018
CUBIC VOLUME OF THE CONDITION SPACE WAS NOT ADDED TO THE PLANS. PLEASE SUBMIT.
• PLEASE ADD THE CUBIC VOLUME OF THE CONDITIONED SPACE TO INFORMATION BLOCK CONTAINING
THE SQUARE FOOT INFORMATION OR A LETTER FROM THE DESIGN PROFESSIONAL SPECIFYING THE
CUBIC VOLUME OF THE CONDITIONED SPACE. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA
BUILDING CODE.
SUBMITTED DOCUMENTS WERE NOT REVIEWED AND APPROVED BY THE DESIGN PROFESSIONAL IN
CHARGE. PLEASE SUBMIT ALL DOCUMENTS AND DRAWINGS IN DUPLICATE REVIEWED AND APPROVED BY
THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH CHAPTER 8 SECTION R802 SUBSECTION
R802.1.7.1 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE.
I
TRUSS ENGINEERING AND TRUSS DRAWINGS SPECIFIED THAT THEY ARE DESIGNED TO THE 2014
FLORIDA BUILDING CODE. PLEASE SUBMIT CORRECTED TRUSS ENGINEERING AND TRUSS PLACEMENT
DRAWINGS DESIGNED TO THE CURRENT CODES. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING
CODE.
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort -Pierce, FL, 34982
Phone:(772)462.2172 Fax:(772)462.6443
EVIEW COMMENTS
Page 2
Comment: A COVER LETTER IS REQUIRED ITO BE SUBMITTED WITH ANY SUBMITTED DOCUMENTS ADDRESSING THE
4/27/2018 PLANS EXAMINERS COMMENTSI NO COVER LETTER WAS SUBMITTED SPECIFYING THE CHANGES OR
SUBMITTED DOCUMENTS.
Comment: PLEASE SEE CLOUDED NOTES IIN THE DESIGN PARAMETER'S FOR WIND LOAD COMPLIANCE ON
4/27/2018 SUBMITTED PAGE 2.0. -PLEASE SHOW THE SOIL DENSITY ON THE PLANS OR SUBMIT A GEOTECHNICAL
REPORT WITH RECOMMENDATIONS FOR THE NEW FILL REQUIREMENTS. SEE CHAPTER 4 SECTION R401
OF THE 2017 FLORIDA RESIDENTIAL CODE.
Comment: ONLY PAGE 2.0 WAS SUBMITTED WITH THE CORRECT BUILDING CODE CYCLE. SEE PAGES 1.0, AND 5.0.
4/27/2018 PLEASE SUBMIT CORRECTED DRAWINGS WITH THE CURRENT CODE CYCLE. SEE SECTION 107 OF THE
2017 FLORIDA BUILDING CODE.
PLANS EXAMINER REVIEW COMPLETE William Durden 4/9/2018 4/27/2018 4/27/2018
Comment:
ZONING REVIEW COMPLETE
Comment: .
Angela
3/30/2018 4/6/2018 416/2018
:.9 1wo� .
Planning &.Development Services
Building & Code Regulation Division.
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462-2172 Fax:(772)462.6443
PROPERTY INFORMATION
Address: 5333 Emerson Ave
City / State / Zip: Fort Pierce, FI 34951-1608
Parcel M 1310-441-0021-000/3
Zoning: AG-1
APPLICATION INFORMATION
Permit Number: 1803-0756
Permit Type:
IEW COMMENTS
1
Owner(s):
Brion Pauley
Jurisdiction: SAINT LUCIE COUNTY
Lot#: Block:
Stories: Automatic Sprinkler System? No
BUILDING RESIDENTIAL (SFR UP TO; 2 FLOORS)
CONTRACTOR INFORMATION r
Contractor Name: Carl A Lachnitt U Fax Number: 772-562-7782
Business Name: Cal Builders Inc
Business Addr: 2020 Old Dixie Hwy Se Ste 6 I Email: Calbuilderinc@Aol.Com
City / State / Zip: Vero Beach, FI 32962
I
REVIEWS AND COMMENTS
Review Tvoe Status Revie led ev Date Started Date Completed Date Released
ADDRESSING ASSIGNMENT COMPLETE LoriSender 4/2/2018 4/2/2018 4/212018
Comment:
DOCUMENTS MISSING PENDING Lasha na Ingram
3/27/2018 Comment: NEEDS NOC
ENVIRONMENTAL REVIEW COMPLETE Lynn Swartzel 3/28/2018 3/30/2018 3/30/2018
Comment:
FRONT COUNTER REVIEW COMPLETE Lashahna Ingram 3/27/2018 3/27/2018 3127/2018
Comment:
I
PE REVIEW COMMENTS (2) INCOMPLETE William Durden 4127/2018
Comment: CUBIC VOLUME OF THE CO i DITION SPACE WAS NOT ADDED TO THE PLANS. PLEASE SUBMIT.
• PLEASE ADD THE CUBIC VOLUME OF THE CONDITIONED SPACE TO INFORMATION BLOCK CONTAINING
4/9/2018 THE SQUARE FOOT INFORMATION OR A LETTER FROM THE DESIGN PROFESSIONAL SPECIFYING THE
• CUBIC VOLUME OF THE CONDITIONED SPACE. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA
BUILDING CODE.
Comment: TRUSS ENGINEERING IS SIGNATURE IS A COPY, MUST BE ORIGINAL SIGNATURE. PLEASE RESUBMIT
CORRECTED DOCUMENTS. �
4/9/2018 • PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER CHAPTER 8 SECTION R802 SUBSECTION
R802.1.7.1 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. TRUSS ENGINEERING MUST HAVE THE
ORIGINAL SIGNATURE OF THE TRUSS MANUFACTURERS ENGINEER, REVIEWED AND APPROVED BY THE
DESIGN PROFESSIONAL IN CHARGE.
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462.2172 Fax:(772)462-6443
4/27/2018
4/27/2018
4/27/2018
4/27/2018
4/27/2018
4/27/2018
Comment:
Comment:
Comment:
Comment:
Comment:
Comment:
PLANS EXAMINER REVIEW
Comment:
ZONING REVIEW
Comment:
EVIEW COMMENTS
Page 2
TRUSS PLACEMENT DRAWINGS ARE NOT SIGNED AND SEALED. - PLEASE FURNISH THE
MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND APPROVED BY THE
DESIGN PERSON OF RECORD IN ACCORDANCE WITH CHAPTER 8 SECTION R802 SUBSECTION R802.1.7.1
OF THE 2017 FLORIDA RESIDENj IAL BUILDING CODE.
SUBMITTED DOCUMENTS WERE NOT REVIEWED AND APPROVED BY THE DESIGN PROFESSIONAL IN
CHARGE. PLEASE SUBMIT ALL DOCUMENTS AND DRAWINGS IN DUPLICATE REVIEWED AND APPROVED BY
THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH CHAPTER 8 SECTION R802 SUBSECTION
R802.1.7.1 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE.
TRUSS ENGINEERING AND TR I SS DRAWINGS SPECIFIED THAT THEY ARE DESIGNED TO THE 2014
FLORIDA BUILDING CODE. PLEASE SUBMIT CORRECTED TRUSS ENGINEERING AND TRUSS PLACEMENT
DRAWINGS DESIGNED TO THEICURRENT CODES. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING
CODE.
A COVER LETTER IS REQUIRED TO BE SUBMITTED WITH ANY SUBMITTED DOCUMENTS ADDRESSING THE
PLANS EXAMINERS COMMENTS. NO COVER LETTER WAS SUBMITTED SPECIFYING THE CHANGES OR
SUBMITTED DOCUMENTS.
PLEASE SEE CLOUDED NOTES IN THE DESIGN PARAMETER'S FOR WIND LOAD COMPLIANCE ON
SUBMITTED PAGE 2.0. -PLEASE SHOW THE SOIL DENSITY ON THE PLANS OR SUBMIT A GEOTECHNICAL
REPORT WITH RECOMMENDATIONS FOR THE NEW FILL REQUIREMENTS. SEE CHAPTER 4 SECTION R401
OF THE 2017 FLORIDA RESIDENTIAL CODE.
ONLY PAGE 2.0 WAS SUBMITTED WITH THE CORRECT BUILDING CODE CYCLE. SEE PAGES 1.0, AND 5.0.
PLEASE SUBMIT CORRECTED DRAWINGS WITH THE CURRENT CODE CYCLE. SEE SECTION 107 OF THE
2017 FLORIDA BUILDING CODEI.
I
COMPLETE William Durden 4/9/2018 4/27/2018 4/27/2018
I
COMPLETE Angela Huff 3/30/2018 4/6/2018 4/6/2018
I
r
Planning & Development Services
Building & Code Regulation Division.
2300 Virginia Avenue
Fort Pierce, FL. 34982
• Phone:(772)462-2172 Fax:(772)462-6443
PROPERTY INFORMATION
Address: 5333 Emerson Ave
City / State I Zip: Fort Pierce, FI 34951-1608
Parcel M 1310-441-0021-000/3
Zoning: AGA
APPLICATION INFORMATION
Permit Number: 1803-0756
Permit Type: BUILDING RESIDENTIAL (SFR UP TO
CONTRACTOR INFORMATION
Contractor Name: Carl A Lachnitt
Business Name:
Business Addr:
City / State / Zip:
Cal Builders Inc
2020 Old Dixie Hwy Se Ste 6
Vero 13earh_ FI 329B2
REVIEWS AND COMMENTS
Review Type
ADDRESSING ASSIGNMENT
Comment:
DOCUMENTS MISSING
3/27/2018 Comment:
ENVIRONMENTAL REVIEW .
Comment:
FRONT COUNTER REVIEW
Comment:
PLANS EXAMINER REVIEW
Comment:
4/9/2018
4/9/2018 Comment:
Comment:
4/9/2018
Comment:
4/9/2018
EVIEW COMMENTS
1
Owner(s):
Brion Pauley
:tion: SAINT LUCIE COUNTY
Lot#: Block:
Stories: Automatic Sprinkler System? No
FLOORS)
Fax Number: 772-562-7782
Email: Calbuilderinc@Aol.Com
I
Status Reviewed By Date Started Date Completed. Date Released
PENDING Lori Bender
PENDING Lashahia Ingram
NEEDS NOC
COMPLETE Lynn.Swartzel 1 3/2812018 3/30/2018 3130/2018
COMPLETE Lashahna-Ingram 3/27/2018 3/27/2018 3/27/2018
INCOMPLETE William IDurden 4/9/2018
• PLEASE ADD THE CUBIC VOLUME OF THE CONDITIONED SPACE TO INFORMATION BLOCK CONTAINING
THE SQUARE FOOT INFORMATION OR A LETTER FROM THE DESIGN PROFESSIONAL SPECIFYING THE
CUBIC VOLUME OF THE CONDITIONED SPACE. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA
BUILDING CODE.
ENERGY CALC'S INFORMATION BLOCK AT THE TOP OF THE PAGE ARE INCOMEPLETE. SEE SECTION
405.4.2 (1) OF THE 2017 FLORIDA ENERGY CODE.
• LINE SEVEN ON THE ENERGY CALC'S ARE INCORRECT, MULTIPLE TYPES AND SIZES OF GLAZED
OPENINGS ON PLANS. PLEASE CORRECT ENERGY CALC'S AS PER SECTION R401.3 OF THE 2017 FLORIDA
BUILDING CODE ENERGY CONSERVATION 6TH EDITION.
• PLEASE SUBMIT THE ENERGY PERFOMANCE SHEETS OR SUBMIT A THE NFRC FENSTRATION
MANUFACTURE CERTIFICATEI FOR THE U-FACTOR AND THE SHGC FOR EACH GLAZED OPENING SHOWING
COMPLIANCE WITH CHAPTER 4 SECTION 402.1.1 OF THE 2017 ENERGY CODE SIXTH EDITION.
Planning & Development services REVIEW COMMENTS
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce; FL. 34982
• Phone:(772)462-2172 Fax:(772)462-6443
Page 2
Comment: • PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER CHAPTER 8 SECTION R802 SUBSECTION
4/9/2018 R802.1.7.1 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. TRUSS ENGINEERING MUST HAVE THE
ORIGINAL SIGNATURE OF THE TRUSS MANUFACTURERS ENGINEER, REVIEWED AND APPROVED BY THE
DESIGN PROFESSIONAL IN CHARGE.
I
Comment: I WAS UNABLE TO COMPLETE MY REVIEW DUE TO SUBMITTED PLANS ARE DESIGNED TO THE 2014
4/9/2018 FLORIDA BUILDING CODE. PLEASE REVISE THE PLANS TO REFLECT THE'CURRENT BUILDING CODE
CYCLE. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE.
Comment: • PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE
4/9/2018 SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED
. DOCUMENTS.
ZONING REVIEW COMPLETE Angela Huff 3/30/2018 4/6/2018 4/6/2018
Comment: