HomeMy WebLinkAboutASSEMBLY DETAILS FINAL88' MIN
90' MAX
OVERALL
HEIGHT
43 1/2' MAX, OVERALL WIDTH
40' MAX, FRAME WIDTH
35 3/4' MAX,
PANEL WIDTH
I t
I
84' SEE SUB JAMB CLIP
MAX TO SUB JAMB
iJAMB _ ASSEMBLY DETAIL
HEIGHT
SHEET 2
83 1/8,
MAX
PANEL
HEIGHT
38' MIN
TO
42 1/2'
MAX
9
2' 12' MAX
MAX, ❑,C, TYP
t
I
SEE SUB JAMB
CLIP TO FLOOR
DETAIL SHEET 2
TI❑GA DOORWAY SYSTEM TDS-S-PA-WS
EXTERI❑R VIEW
DESIGN PRESSURE RATING IMPACT RATING
±50PSF
THIS SYSTEM WAS NOT TESTED FOR WATER LARGE AND SMALL
INFILTRATION AND IS TO BE INSTALLED ONLY MISSILE IMPACT
WHERE THE WATER REQUIREMENT IS NOT NEEDED
TEES MEG
Spectrum Hare &
Brands Home Improvement
0
NOTES:
1 ) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO
COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE INCLUDING
THE HVHZ.
2) STEEL FRAMING AND CONCRETE OPENING TO BE DESIGNED AND ANCHORED
TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND
CONCRETE OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR
ENGINEER OF RECORD.
3) BUILDING GIRT AND OPTIONAL INTERMEDIATE BUILDING GIRT TO BE
DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO
STRUCTURE. BUILDING GIRT AND OPTIONAL INTERMEDIATE GIRT ARE THE
RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD.
4) ALLOWABLE STRESS INCREASE OF 1 /3 WAS NOT USED IN THE DESIGN OF
THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION FACTOR Cd=1.6 WAS
USED FOR WOOD ANCHOR CALCULATIONS.
5) FRAME MATERIAL: FORMED 16GA. (.053" MIN.) GALVANNEALED STEEL.
6) DOOR PANEL MATERIAL: FORMED 20GA. (.036" MIN.) GALVANNEALED STEEL.
7) APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS
PRODUCT IN WIND BORNE DEBRIS REGIONS.
8) EACH PANEL IS FITTED WITH THREE HINGES LOCATED AT 6" MINIMUM UPTO
10" MAXIMUM FROM EACH END WITH ONE AT PANEL MIDSPAN.
HARDWARE SCHEDULE
A.
ML 1300 M❑RTISE LOCK BY TELL MANUFACTURING, INC,
B.
RIM PANIC DEVICE 9500 SERIES BY TELL MANUFACTURING, INC,
C.
CYLINDRICAL LOCK LC1200 SERIES BY TELL MANUFACTURING, INC,
D.
STEEL HINGES H4545 BY TELL MANUFACTURING, INC.
E.
ALUMINUM THRESHOLD 1/2'— HIGH BY H❑UST❑N NON—FERROUS
ITEMS A, B AND C ARE INTERCHANGEABLE
TABLE OF CONTENTS
SHEET NO.
DESCRIPTI❑N
1
ELEVATI❑N, ANCH❑RING LAYOUT AND NOTES
2
DETAILS AND NOTES
3
BILL OF MATERIALS AND CROSS SECTI❑N
4
CROSS SECTI❑N
5 - 6'
INSTALLATI❑N DETAILS
7 - 8
COMPONENTS
Robert J. Amoruso, P.E.
Florida P.E. No. 49752
Digitally signed
��pMES
�O�4Q,`�\CE/Jy-F OpG' by RobertJ
N d9752 •� Amoruso
9 • S E OF "•� Date:
.;Fss`• R jO��� 2017.04.07
SKMUK '�i, �ONA�.•° 14:08:22-04'00'
TW
PTC PRODUCT DESIGN GROUP, LLC
PO BOX 520775 1 LONGWOOD, FLORIDA 32752
FBPE C.A. NO. 25935
Phone: 321.690.1788 I Email: info@pto-corp.com
TELL DOORS & WIND❑WS, LLC,
2505 WEST 11TH STREET, H❑UST❑N, TEXAS 77008
TI❑GA DOORWAY SYSTEM TDS—S—PA—WS
IGINEER DATE ❑S STEEL SINGLE DOOR — IMPACT
ELEVATI❑N, ANCH❑RING LAYOUT AND NOTES
TJH 07/06/10
SIZE
PROVED DATE DWG
RB "� 08-01021
JA 03/20/17
LIEN
THIRD ANGLE PR❑JECTI❑N RELEASE STATE Ev
F-INAL B
4 1 L N T S SHEET
1 OF 8
C
STRIKE JAMB (2) PER
-11 24 L❑CATI❑N
CLIP IS ATTACHED
TO SUB JAMB AND
FRAME JAMB WITH
(4) ITEMS #24
SUB JAMB --� II II I _Y f II 1 1 INTERI❑R
EXTERI❑R
SUB JAMB CLIP
W LLULU I U JHI`"ID
CORNER C❑NSTRUCTI❑N DETAIL
TEES MEG
Spectrum Han+ware &
Brands Home Improvement
(2) PER
L❑CATI❑N
IS ATTACHED
SUB JAMB AND
ME JAMB WITH
ITEMS #24
FERI❑R
JAMB
NOTES:
1cL FORANCHORING-SUB JAM$:CLIP TQ16GA (.06Q' MIN -)STEEL FRAM{NG'USE,5"l`1.6;` :1:8
1BOLT WITH_5/1"6"=18<NUT=AND=5/16":WASHER._BOLT_,TO RE-OF:SU.FEICIENT_LENGTHrTO-
2) FOR ANCHORING SUB JAMB CLIP INTO CONCRETE AT FLOOR USE:
- 5/16" MINIMUM 90' L-BOLT SET IN CONCRETE WITH 5/16" NUT AND WASHER. BOLT
TO BE OF SUFFICIENT LENGTH TO ACHIEVE 6" MINIMUM EMBEDMENT INTO CONCRETE AND
3-THREADS MINIMUM BEYOND NUT AND WASHER WITH 2 3/4" MINIMUM EDGE DISTANCE.
90' L-BOLT TO BE MINIMUM A36 STEEL.
- 3/8" HILTI KWIK BOLT 3 OF SUFFICIENT LENGTH TO ACHIEVE 2 1/2" MINIMUM
EMBEDMENT INTO CONCRETE WITH 4 1/2"-MINIMUM EDGE
�= 3/8" 1 -EDGE k&-, ,SUFF101ENTLENGTH"TO ACHIEV..E 2"MINIM JM EMBEDMENT INTO:
--. g30. ^'c'_ —...: +'��-`'.�.-r fi r.,,, —L.___- .<..
ITVV'!—APC(N---OF SUFFICIENT -LENGTH TO ACHIEVE 1 3/4 MINIMUM EMBEDMENT
INTO CONCRETE WITH 3 3/16" MINIMUM EDGE DISTANCE.
LOCATE ALL ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
MINIMUM EDGE DISTANCE LOCATE ANNCHORS-AS SHOOWN IN -ELEVATIONS AND
INSTALLATION DETAILS .µ
FO (RING SUB JAMB CLIP TO WOOD USE 5/16" LAG SCREW WITH MINIMUM
EMBEDMENT OF 1-3/4", MINIMUM EDGE DISTANCE OF 1-1/4" AND MINIMUM SPACING OF
1-1/4". LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
5) WASHERS SHALL BE USED WHEN ANCHORS ARE INSTALLED IN OVERSIZE HOLES
(CLIP HOLE DIAMETER 1/16" GREATER DIAMETER THAN ANCHOR DIAMETER).
6) MINIMUM 2 ANCHORS PER SUB JAMB CLIP FOR ATTACHMENT TO SUPPORTING SUBSTRATE
7) ALL FASTENERS TO BE CORROSION RESISTANT.
8) INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR
MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN
SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
A. WOOD - MINIMUM SPECIFIC GRAVITY OF G=0.42 (NON-HVHZ) AND G=0.55 (HVHZ)
B. CONCRETE - MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI.
C. STEEL FRAMING: 16GA. (.060" MIN.) Robert J. Amoruso, P.E.
Florida P.E. No. 49752
TJH 107/06/10
RJA 103/20/1
THIRD ANGLE PROJECTION
�•.•`` MEq��•,
Digitally signed
by Robert J
1N 49752
Amoruso
E OF u/
Date:
2017.04.07
14:08:34-04'00'
PTC PRODUCT DESIGN GROUP, LLC
PO BOX 5207751 LONGWOOD, FLORIDA 32752
FBPE C.A. NO. 25935
Phone: 321.690.1788 1 Email: info@ptc-corp.com
TELL DOORS & WINDOWS, LLC.
2505 WEST 11TH STREET, HOUSTON, TEXAS 77008
TI❑GA DOORWAY SYSTEM TDS—S—PA—WS
❑S STEEL SINGLE DOOR — IMPACT
DETAILS AND NOTES
F-B- I I "° 08-01021 �
STATE FINAL tB
J T S I
SHEET OF 8
'RTS LIST
NO, PART NUMBER DESCRIPTI❑N MANUFACTURER MATERIAL
1
T-10,3,1
TI❑GA PA HEAD JAMB 16GA,
TELL MANUFACT,
GALVANNEALED STEEL
2
T-10,2,1
TI❑GA PA HINGE JAMB 16GA,
TELL MANUFACT,
GALVANNEALED STEEL
3
T-1,7
THESH❑LD, 1/2" HIGH
H❑UST❑N NON-FER,
ALUMINUM 6063-T5
4
T — 1,2,2
FRAME HINGE REINFORCEMENT TOGA,
DAYT❑N INDUSTRIES
GALVANNEALED STEEL
5
T-1,1,1
TI❑GA B❑TT❑M DOOR SKIN 20GA,
TELL MANUFACT
GALVANNEALED STEEL
6
T-112
TI❑GA TOP DOOR SKIN 20GA.
TELL MANUFACT.
GALVANNEALED STEEL
7
T-1,1,3
TOP CAP DOOR CHANNEL 20GA,
TELL MANUFACT,
GALVANNEALED STEEL
8
T-114
TELL MANUFACT,
GALVANNEALED STEEL
9
T-1,1,5
BOTTOM DOOR CHANNEL 1�15A,
TELL MANUFACT.
GALVANNEALED STEEL
10
T-116
DOOR HINGE REINF❑RCEMENT TOGA,
DAYT❑N INDUSTRIES
GALVANNEALED STEEL
11
T-117
DOOR FOAM CORE 1 LB/FT DENSITY
POLYSIYRENE
12
T-118
DOOR CLOSER REINF❑RCEMENT 12GA.
TELL MANUFACT,
GALVANNEALED STEEL
13
T-1,1,10
MORTISE LOCK REINF❑RCEMENT 14GA.
TELL MANUFACT.
GALVANNEALED STEEL
14
T-10,4,1
TI❑GA PA STRIKE JAMB 16GA.
TELL MANUFACT,
GALVANNEALED STEEL
15
T-10,4,3-
PA STRIKE JAMB CLIP 12GA,
TELL MANUFACT,
GALVANNEALED STEEL
16
T-10,2,3
PA HINGE JAMB CLIP 12GA.
TELL MANUFACT,
GALVANNEALED STEEL
17
T-1,2.4
FRAME WEATHERSTRIPPING
FOAM
18
T-1,5
HINGES - H4545 SERIES
TELL MANUFACT,
STEEL
19
T-1,68
M❑RTISE LOCK ML 1300
TELL MANUFACT.
STEEL
-20
T-I,6A
CYLINDRICAL LOCK LC1200 SERIES
YALE SECURITY
21
T-1.8
DOOR SWEEP, DT100101
TELL MANUFACT.
ALUMINUM 6063-T5
22
TI❑GA-PA_SUB__JAMB-I6GA,
TE-L-L—MANUF-AC-T--
-GAL-VANNEAL-ED—STEEL-
_T-10,9
23
T-10,10
TI❑GA PA SUB JAMB CLIP 12GA,
GALVANNEALED STEEL
24
S1
#12-24 X 1 1/4' HEX HEAD TEK
STEEL
25
B1
5/16'-18 X 3/4' HEX CAP SCREW
STEEL
26
N1
HEX NUT 5/16"
STEEL
27
W1
FLAT WASHER 5/16"
STEEL
28
S2
#8-32 X 1/2' PPH SMS
STEEL
2 9
S 2
#14 X 1/2' PFH SMS
STEEL
30
S 3
#10-24 X 1/2' UC PFH SMS
STEEL
31
T16C
RI- PANIC DEVICE 9500 SERIES
TELL MANUFACT.
32
T-119
CYLINDRICAL LOCK REINFORCE. 16GA
TELL MANUFACT,
GALVANNEALED STEEL
TELL
MF—G
W.6m,
Spectrum
Brands
Hardware &
Home Imp. amw t
cmaw:
AND CON:
IN&�
EX1
VERTICAL CROSS SECTI❑N
DRAFTER IDATE
TJH 107/06/10
RJA 103/20/1
THIRD ANGLE PROJECTION
+EE:E3-
Robert J. Amoruso, P.E.
Florida P.E. No. 49752
Digitally signed
by Robert J
Amoruso
Date:
2017.04.07
14:08:46-04'00'
PTC PRODUCT DESIGN GROUP, LLC
PO BOX 520775 1 LONGWOOD, FLORIDA 32752
FBPE C.A. NO. 25935
Phone: 321.690.1788 1 Email: info@ptc-corp.com
TELL DOORS & WINDOWS, LLC,
2505 WEST 11TH STREET, HOUSTON, TEXAS 77008
TI❑GA DOORWAY SYSTEM TDS-S-PA-WS
❑S STEEL SINGLE DOOR - IMPACT
BILL OF MATERIALS AND CROSS SECTI❑N
B I I NO
STATE FINAL
NTS
08-01021
"Do ,
H❑RIZ❑NTAL CROSS SECTI❑N
TELL MF G
Spectrum Hardware &
Brands Home Improvement
DATE
T J H 107/06/10
13F SPECTRUM APPROVED DATE —"�
Es�ME„n,L RJA 03/20/17
AR
IS DDC
1 THY THIRD ANGLE PR❑JECTI❑N RELE
wsm m ANY
' PUBLISHED
WITTEN MAT
Robert J. Amoruso, P.E.
Florida P.E. No. 49752
01 SPMES ����i4 Digitally signed
Q�kQ�..GE497 by Robert J
�_+ N A9752 •'�*� Amoruso
3 EE O � Date: STA
s;<.0R1oPG.2,` 2017.04.07
' '''iS1z;NQ;�14:08:57-04'00'
PTC PRODUCT DESIGN GROUP, LLC
PO BOX 520775 1 LONGWOOD, FLORIDA 32752
FBPE C.A. NO. 25935
Phone: 321.690.1788 1 Email: info@ptacorp.com
TELL DOORS & WINDOWS, LLC,
2505 WEST 11TH STREET, HOUSTON, TEXAS 77008
TI❑GA DOORWAY SYSTEM TDS—S—PA—WS
❑S STEEL SINGLE DOOR — IMPACT
CROSS SECTI❑N
DWG
NO 08-01-021
STATE FINAL
■1111MW3��3111Z
2�
(3) ALONG
HEAD
SUB JAMB CLIP
STRIKE JAM
24
SUB JAMB CLIP
STRIKE JAMB
9
VERTICAL CROSS SECTI❑N
SUB JAMB TO GIRT
5/16' BOLT WITH 5/16' NUT AND
WASHER. BOLT MUST BE 3-THREADS
BEYOND NUT MIN, ENGAGEMENT
SUB JAMB
I
INTERIOR
BUILDING GIRT
BY OTHERS
STRIKE ,
EX1
CONCRETE FLOOR
BY OTHERS
5/16' BOLT WITH 5/16' NUT AND
WASHER, BOLT MUST BE 3-THREADS
BEYOND NUT MIN, ENGAGEMENT
BUILDING GIRT
BY OTHERS
JSUB
AMB TEES MEG
Spectrum Ham6ore &
Brands Home Improvement
VERTICAL CROSS SECTI❑N
SUB JAMB CLIP TO
CONCRETE FLOOR INSTALLATION
(4) PER
CLIP
JAMB
6' MINIMUM 90' L-BOLT SET IN CONCRETE
H 5/16' NUT AND WASHER. BOLT TO BE SET
IN CONCRETE MIN, AND HAVE 3-THREADS MIN,
'❑ND NUT MIN, ENGAGEMENT AND 2 3/4' MIN,
iE DISTANCE OR
_. 3' HILTI KWIK BOLT 3 WITH 2 1/2' MIN,
EMBEDMENT INT❑ CONCRETE AND 4 1/2'
MIN, EDGE DIST.
Robert J. Amoruso, P.E.
Florida P.E. No. 49752
••o•• jpMES qo, Digitally signed
�' by Robert J
o��Q'.�•cerosF o9Gm':
Amoruso
Date:
...A2017.04.07
�i,S�ONA� �E�•`� 14:09:08-04'00'
PTC PRODUCT DESIGN GROUP, LLC
PO BOX 520775 1 LONGWOOD, FLORIDA 32752
_ FBPE C.A. NO. 25935
Phone: 321.690.1788 1 Email: info@ptc-corp.com
TELL DOORS & WINDOWS, LLC,
2505 WEST 11TH STREET, HOUSTON, TEXAS 77008
TI❑GA DOORWAY SYSTEM TDS—S—PA—WS
❑S STEEL SINGLE DOOR — IMPACT
INSTALLATI❑N DETAILS
B DOG 08-01021
'JMENT IS THE PAMLIY EF SPECTRUM
N� � m �� AL RJA 03/20/17
RUN �g SECRETS �� M��Y RELEASE STATE EVp [ILK
3PMWS SMALL DE DISCLOSED TE MY THIRD ANGLE PROJECTION FINAL 1]
rM PERSR7, CI8D71, ER PUBLISHED
SPECTRUM BRANDS' PRIDR WRITTEN SCALE N T S SHEET 5 OF 8
TJH 107/06/10
VERTICAL CROSS SECTI❑N
SUB JAMB CLIP TO
CONCRETE FLOOR INSTALLTI❑N
MIN.
D
H 2' MIN.
D
TELL MEG
Spectrum Hardware &
Brands Home Improvement
INTERI❑R
CONCRETE FLOOR
BY OTHERS
3/16' ITW
TAPC❑N
► .a
o c Q' T
A o
a e ;. 1 3/4' MIN.
a EMBEDMENT
ia. 9 a g d
2 5/8' MIN.
EDGE DIST,
VERTICAL CROSS SECTI❑N
SILL TO CONCRETE FLOOR INSTALLATI❑N
DRAFTER IDATE
TJH 107/06/10
APPROVED DATE '�
„E MUM W ��, ,
R ITS AML1ATES. THE R J A 0 3/ 2 0/ 17
MCUMM ARE MIDI T„u_
WX a
SECRETS PMETARY RELE
s
Ss, B>ER SDI�anmrr THIRD ANGLE PROJECTION
w�LLu HE ntsansfn ro riY
%6 59 � PRnTEN D
HRAtIDS' PRIIHi YRITTEl!
Robert J. Amoruso, P.E.
Florida P.E. No. 49752
Digitally signed
by Robert J
" 49752 .Amoruso
E OF :�4/ Date:
ORIOP:?`.� 2017.04.07
A�-���`�
14:09:18-04'00'
PTC PRODUCT DESIGN GROUP, LLC
PO BOX 520775 1 LONGWOOD, FLORIDA 32752
FBPE C.A. NO. 25935
Phone: 321.690.1788 1 Email: info@ptc-corp.com
TELL DOORS & WINDOWS, LLC.
2505 WEST 11TH STREET, HOUSTON, TEXAS 77008
TI❑GA DOORWAY SYSTEM TDS—S—PA—WS
❑S STEEL SINGLE DOOR — IMPACT
INSTALLATI❑N DETAILS
7Nw.5
08-01021
STATE EV
FINAL B
I T S SHEET 6❑ F 8
1/2
F.
O
14
TI❑GA PA HINGE JAMB
TI❑GA PA STRIKE JAMB
16GA, GALVANNEALED
STEEL .053" MIN, THICK
1/2"
1.00 5 3/4" 11110-1
_ 3O. THRESH❑LD L/_2n HLGH
ALUMINUM 6063-T5 ,105" THICK
27/64"
5/16"
1 45/64" .
1/8
O TI❑GA BOTTOM DOOR SKIN
20GA ' GALVANNEALED STEEL ,036" MIN. THICK
LEFT END SHOWN, RIGHT END IS SIMILAR
1/8"
5/16"
O TI❑GA TOP DOOR SKIN
20GA STEEL ,036' MIN, THICK
LEFT END SHOWN, RIGHT END IS SIMILAR
7/32'
1 37/64" 3/4"
(REF)
23/32"
tl 7/8"
1 59/64" 9/16"(REF)
O7 TOP CAP DOOR
CHANNEL
20CA GALVANNEALED FRAME WEATHERSTRIPPING
STEEL ,036" MIN. THICK 21 DOOR SWEEP 17
FOAM
1 43/64"
23/32"
O TOP DOOR CHANNEL
160A GALVANNEALED
STEEL .053" MIN, THICK
1 43/64'
t
O BOTTOM DOOR CHANNEL
16GA GALVANNEALED
STEEL .053' MIN. THICK
TELL
Spectrum
MFG
Hardware &
Home Improvement
ALUMINUM 6063-T5,042" MIN. THICK
EPDM
DRAFTER
TJH 107/06/10
OF SPEcnmRJA 03/20/1
ES. Tlf
CQlri°QITIAL
IZWM M'f
is PDOC�KM
� aU'M ANY THIRD ANGLE PROJECTION
PYRI�ITQ�°° 1
Robert J. Amoruso, P.E.
Florida P.E. No. 49752
Digitally
signed by
N 49752 •=�0 Robert J
Amoruso
�:•• STA E OV
Date:
2017.04.07
14:09:32-04'00'
PTC PRODUCT DESIGN GROUP, LLC
PO BOX 520775 1 LONGWOOD, FLORIDA 32752
FBPE C.A. NO. 25935
Phone: 321.690.1788 1 Email: info@ptc-corp.com
TELL DOORS & WINDOWS, LLC.
2505 WEST 11TH STREET, HOUSTON, TEXAS 77008
TI❑GA DOORWAY SYSTEM TDS-S-PA-WS
❑S STEEL SINGLE DOOR - IMPACT
COMPONENTS
B I -I � 08-01021
STATE FINAL FVB
ITS F I
SHEET 7 [IF 8
q
1 3/4"
8 3/64"
4 1/4"
5 3/4"
23 TI❑GA PA SUB JAMB CLIIP
12GA, GALVANNEALED STEEL .108" MIN. THICK
O TI❑GA PA HEAD JAMB
16GA, GALVANNEALED
STEEL ,053" MIN, THICK
I
9/32"
0 0
000
0 0
O
00
10"
00
O
0 0
000
Io 0
10 DOOR HINGE REINF❑RCEMENT
TOGA, GALVANNEALED STEEL ,138"MIN,
1. 15/64" --�►I�
1"
1"
n
15 rH J I miNr- JAMB CLIP
16 PA HINGE JAMB CLIP
12GA, GALVANNEALED
STEEL .108' MIN, THICK
TESL
SpecBru�m
MFG
Hardware &
Home Improvement
DOCUMENT IS
9/32" --�
00
000
0
O
0
10"
0
O
0
00o
I0 0
1 1/4"
O FRAME HINGE REINF❑RCEMENT
THICK 10GA. GALANNEALED STEEL ,138' MIN, THICK
6" TO 12"
1 3/4"
Robert J. Amoruso P.E.
TI❑GA PA SUB JAMB Florida P.E. No. 49752
16GA, GALVANNEALED
STEEL ,053" MIN. THICK ������ jP�ES q•.,, Digitally signed
. �Q'•'�GEMS'•�.9'i� by Robert J
NQ 49752 1.0 Amoruso
�9 STA E OF � Date:
'OAF OR IV.- � 2017.04.07
'S Cs.
NAIE.•
"M s...% 14:09.43-04'00'
PTC PRODUCT DESIGN GROUP, LLC
PO BOX 5207751 LONGWOOD, FLORIDA 32752
FBPE C.A. NO. 25935
Phone: 321.690.1788 1 Email: info@ptc-corp.com
DRAFTER DATE
TELL DOORS & WIND❑WS, LLC,
CHECKED DATE 2505 WEST 11TH STREET, H❑UST❑N, TEXAS 77008
TITLE
TI❑GA - D❑❑RWAY SYSTEM TDS-S-PA-WS
ENGINEER DATE STEEL SINGLE DOOR ❑S - IMPACT
TJH 07/06/10 COMPONENTS
SIZE
APPROVED DATE p DWG NO
RUN
TrAL RJA 03/20/17 D 08-01021
NANY T V [IER
THIRD ANGLE PR❑JECTI❑N RELEASE STATE FINAL EB
SUALE N T S - SHEET 8 OF