HomeMy WebLinkAboutLETTER-CAPSHEET INSTALLATION� �dPNlld�
John M. Foster -Architect/ stL
Member - American Institute of Architects - LEED AP May 22, 2019
11205 Ridge Ave.
Fort Pierce, Florida 34982
Florida Reg. No. 8511
Planning & Development Services RECEIVED
Building & Code Regulation Division
2300 Virginia Avenue MAY 2 3 2p�g
Ft. Pierce, Florida 34982 ST, LuCiQ County, Permitting
Roofing Underlayrnent & Capsheet installation
Miller Residence
107 Sheridan Lane, St. L /cie County, Florida
Permit # 1803-0668
Per FBC 2017 - Sections R905.1.1, Table Underlayment, R905.10 Metal roof
Panels & R905.11 Modified bitumen roofing has been installed at the above
captioned address. Note that the St. Lucie County Property Appraiser lists the
Just Market Value of this structure at $130,000.
1) On April 4, April 24 & May 20, 2019, 1 personally observed the work in place.
2) PolyGlass "PolyStick TU711+" self -adhered underlayment has been installed
over PolyGlass` mechanically fastened tapered "iso" foam insulation with a
minimum slope of 1 /4" per foot in areas indicated as "self -adhered base & cap -
sheet" on approved plans.
3) PolyGlass self -adhered "PolyFresco" white granular surface modified cap was
installed ove(the PolyStick underlayment.
4) Self -adhered Boral "MetalSeal" underlayment was installed on areas noted as
"54 .Galvalume" roofing.
To the best of my professional knowledge and belief, this installation meets the
requirements of the Florida Building Code, Edition 6, 2017.
If t uestions regarding this matter, please contact me as noted
a reP�• .... oR
• •�N M.
Fos, i� '�� •• ��
FP
• REVIEWED FOR
r AIA CODE COMPLIANCE
�'••� LUCIE COON
FRFD ARc`�`�F1 L E C PY' -OCC
Florida Building Code Online
5/21/19, 4:59 PM
BCIS Home f Log In i User Registration Hot Topics Submit Surcharge Slats & Facts i
�i0l
Product Approval I
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
n a •ew FL # FL14317-R10
Application Type i Revision
Code Version 2017
Application Status I Approved
Comments I
Archived <`
Product Manufacturer �BoralRoon!fln�g
Address/Phone/Email enter Drive
Suite 100
Irvine, CA 92618
(130.1) 380-6091
RobinAnderson@boral.com
Authorized Signature Thomas Jemmett
tho.mas.Jemmett@boral.com
Technical Representative Adrian Cooper
Address/Phone/Email 135�NW 20th Street
Boca Raton, FL 33431
(954) 520-5461
Quality Assurance Representative
Address/Phone/Email
Category / Rooflngi
Subcategory `►� Underlayments
�� tF@PR;306L2 A9Ctir�BpfE kHPit-iSifJbft7tN� ,. X!. ' ��
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
=; Evaluation Report -Hardcopy Received
Florida Engineer or Architect Name who developed
Robert J. M. Nieminen
the Evaluation Report
I
Florida License
PE-59166 ,i
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
08/21/2020�
Validated By
John W. Knezevlch, PE
a ValldationChecklist - Hardcopy Received
1'
Certificate of Independence
FL14317 R10i COI 2018 01 C_ OI NIEMINEN.pdf
i -
Referenced Standard and Year (of Standard)
Standard Year
ASTM D1970 2015
https://floridabullding.org/pr/pr app_dtl.aspx?param =wGEVXQwtDgsbCUITKel20BoXpSjktfpju5SJCf9NBzd024B1g6rhfA%3d%3d Page 1 of 2
Florida Building Code Online
5/21/19, 4:59 PM
FRSA/TRI (April 2012) 04-12
UL 1897
i
Equivalence of Product Standards
Certified By i
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
10/12/2018
Date Validated
10/15/2018'
Date Pending FBC Approval
10/22/2018
Date Approved
12/11/2018
Cummnry of Prndur►c
2012
2012
FL # Model, Number or Name Description
4317.1 Boral Roof Underlayments ) Roof underiayments for use in prepared roof assemblies I
Limits of Use I Installation Instructions
Approved for use in HVHZ: No FL14317 R10 11 2018 ID FINAL_g BORAL Underlay en s_FL34317
Approved for use outside HVHZ: Yes B) 0 pdf
Impact Resistant: N/A Verified By: Robert J. M. Nieminen PE - 59166
Design Pressure: +N/A/-210 Created by Independent Third Party: Yes
Other: 1.) The design pressure In this application Evaluation Reports
pertains to a particular underlayment system for FL14317_@U_&E_201$_10 FINAL _j:$ BORAL_Underlayments FL14317-
use under foam -on the systems. Refer to ER RiQ.pdf
Section 5.6.4. 2.) 114er to ER Section 5 for Limits Created by Independent Third Party: Yes
of Use.
Back taaxt
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of FloHda is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. `Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter
455, F.S., please click here .
Product Approval Accepts:
®®99E
I
I
https://floridabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgsbCUITKel2OBoXpSjktfpju5SJCfgNBzdO24Blg6rhfA%3d%3d Page 2 of 2
NEORECta.
Certificate of Authorization #32455
i 353 Christian Street, Unit #13
Oxford, CT 06478
a (203) 262-9245
ENGINEER EVALUATE } TEST CONSULT CERTIFY
Boral Roofing
7575 Irvine Center Drive, Suite 100
Irvine, CA. 92618
(602)269-2288
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and
construction materials in the State of Florida. The docume
P.E. for use of the product under the Florida Building Code
described. herein have been evaluated for compliance with
herein.
Evaluation Report M35710.12.10-R11
FL14317-R10
Date -of Issuance:12/21/2010
Revision 11:10112/2018
the applicable rules and regulations governing the use of
station submitted has been reviewed by Robert Nieminen,
oriittul ifs m,Gode<; ResidePitral Vo e. The products
khe 6th Edition (2017) Florida Building Codetsections noted
DESCRIPTION: Boral Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of
this Evaluation Report relative to updated Code requirements wlith each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.,
INSPECTION: Upon request, a copy of this entire Evaluation Report1 shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8. I
Prepared by: q,�.µ�����dr„--
1� �'...�.owaawn. ...awri..w' -: D7 .=.!t?•3` •'M I t�� =
Robert J.M. Nieminen, P.E. :fix • _ ,T,_
; �� ' The facsimile seal appearing was authorized by Robert
Florida Registration No. 59166, Florida DC4 ANE1983 Nleminen, P.E. an 10/12/2018. This does not serve as an
electronically signed document.
CERTIFICATION of INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial Interest in any company manufacturing or
distributing products it evaluates. I
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the'approval process of the
product.
S. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
i
t
a
r
NEMO etc.
ROOFING COMPONENT EVALUATION:
SCOPE:1.
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Boral Roof Underlayments, as marketed by Boral Roofing, have demonstrated
compliance with the following sections of the 61 Edition (2017) Florida Building Code through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations
/ Conditions of Use set forth herein.
STANDARDS:2.
C r/t ,;"£'p•"S y.� S.z r a !'•-r4,t-w.'^c},.5 ! fir".• !� `. 5 '4l r -•dj}/ 'k iv' K! �.
Sectionor?w +n,r}l..Y 1 .., pro e .. "r?� g._'_' f_StaRf�aid..�:...: ' ✓"'•Ear
1504.3.1 Wind Uplift UL 1897 2012
1507.1.1, T1507.1.1, Physical Properties ASTM D1970 2015
1507.2.9.2
1507.3.3 I Physical Properties FRSA/TRI April 2012 (04-12) 2012
3. REFERENCES:
on Re. fenceN111 `°s`., .....s.�.:
ERD (TST 6049) Physical Properties M36790.07.11 09/30/2011
ERD (TST 6049) Physical Properties B40380.08.12 08/28/2012
ERD (TST 6049) Tensile Adhesion / LTA C41420.09.12-2 09/11/2012
ERD (TST 6049) Adhesion B41940.09.12 09/13/2012
ERD (TST 6049) Tensile Adhesion / LTA B47390.07.14-1 07/31/2014
ERD (TST 6049) Tensile Adhesion / LTA B47390.09.14 09/04/2014
OC (PDM1838) Physical Properties Equivalency statement 11/02/2017
PRI (TST5878) ASTM D1970 NEI-031-02-02:REV 10/27/2010
PRI (TST 5878) 1 ASTM D1970 NEI-029-02-01:REV 12/03/2010
PRI (TST 5878) Tensile Adhesion / LTA NEI-046-02-01REV 12/17/2010
PRI(TST5878) FRSA/TRI April 2012 NEI-076-02-01 02/14/2011
PRI (TST 5878) I ASTM D1970 NEI-034-02-02 01/29/2013
PRI (TST 5878) ' Wind Uplift BORR-001-02-01 03/17/2015
PRI (TST 5878) Wind Uplift BORR-005-02-01 06/24/2015
PRI (TST 5878) Tensile Adhesion / LTA DAPF-002-02-01 03/08/2018
PRI (TST 5878) , ASTM D1970 (adhesion) OCF-443-02-01 10/11/2018
UL, LLC. (QUA 9625) Quality Assurance Service Confirmation Exp. 08/21/2020
A. '•OrDESCRIPTION:
4.1 Boral® TileSeal SO' is a nominal 50-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof
underlayment; meets ASTM D1970.
I
4.2 Boral® TileSeall is a nominal 60-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof
_. ...iezwnderlavment: meets.AS.T.M.D1970and FRSA/TRI 04-12. �<..a=y..�t�•.,-s,���z ,a, ,�.,.,..__._�,.�•�..
4.3 Boral® Meta kall is a nominal 60-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI 04-12.
�wMas�^'^0,..,a-.,•Y<c,cmY.nrlavanon:a.:..Fa,+a:;"C•arc«:vzria.r=:w.�t-?ccr�r%7;+,as• .,t:,•r �c g�.,.�;trM'r ..: .•:":.` •r.:r''sr.�?nr"r.`v .:s. ';°°c:.•=
4.4 GatorSeal® is a nominal 55-mil thick, granular -surfaced,` fiberglass reinforced, self -adhering SBS modified bitumen
roof underlayment; meets ASTM D1970.
4.5 Citadel0ii Plus is a nominal 48-mil thick, fabric -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen
roofing underlayment for use as a base -layer in multi -ply underlayment systems; meets ASTM D1970.
i
I
NEMO ETC, LLC Evaluation Report M35710.12.10-R11
Certificate of Authori:atlon#32455 0 EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R10
Boral Roof Underlayments: (602) 269-2298 Revision 11:10/12/2018
Page 2 of 8
1
I
II
1I
I
( II
MEMO etc.
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically' or that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZjurisdictions.
5.3 Fire Classification is not part of this LaboratorylReport; refer to current Approved Roofing Materials Directory for
fire ratingts of this product.
5.4 Boral Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents.. If not listed; a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined withilIsupporting data for the prepared roof covering.
5.5 Allowable Roof Covers: Table 1 pertains to uselof each listed underlayment by -itself beneath the stated roof
covers. Refer to the installation instructions for multi -ply underlayment options.
5.5.1
TABLE I:
ROOF COVER OPTIONS
`ltiti ! +�+ � t -
•rr{ r
A.ti :5 +, . ; , '' ^'.
+.1 7^ a`.�is'.::r�4k'. ,`>.:7V'
�' 1'• t
'hYl a �1 Y
{
jRt511�n,1e3}
.. .�.ire.!";:�..,...:.t..�,{�h?��ngfPSC;'...�r
r?.�Ac:tin, ..�....X.Y'..j�.}.R,
,'.•.�.... �..�
,`�'.�:'TJ,..r.C...n,�,.
...
::.. .......: ..:. ..
Boral TileSeal SO"T
Yes
No
1 No
Yes
Yes
Yes
Boral TileSeal"T
Yes
Yes
Yes
Yes
Yes
Yes
� (See 5.5.1)
Boral MetalSeal"T
Yes
Yes
i Yes
Yes
Yes
Yes
(See 5.5.1)
GatorSeal
Yes
No
� No
No
Yes
Yes
"Adhesive -set Tile" is limited to use of following Approved tile adhesives / underlayment combinations.
ADHESIVETABLE IA: ALLOWABLE TILE
.•\!. �.` 4 r' d, �,. ! ✓ C.'f .+, `'4t J. iia, ti•! 1'y1} F FW' t t P. -
P oridairoduct �
v 40 -QJ N7,
^e.-ai - - i,Y r '..
� • ti � ..
+ ' 4 tlndarlaylnents
s ,
�e•}......... rrax •>> ...� ....;:..,„-k die fk a.P.provalx"a
�i
DAP Foam Touch 'n Seal StormBond Roof Tile Adhesive
FL14506
Boral TileSeal"T or Boral MetalSeal"T
DAP Foam Touch'n Seal StormBond 2 Two -Component
Polyurethane Roof Tile Adhesive
FL21374
Boral TileSeal"T or Boral MetalSeal"T
Dow TILE BOND"' Roof Tile Adhesive
FL22525
Boral TileSeal"T or Boral MetalSeal"T
ICP Adhesives Polyset® AH-160
1 FL6332
Boral TileSeal"T or Boral MetalSeal"T
ICP Adhesives Polyset® RTA-1
FL6276
BoraI T IIeSeal"T or Boral MetalSeal"T
I
I
II
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
J
NEMO ETC, LLC Evaluation Report M35730.12.10-Ri1
Certificate o/Authorization #32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION t FL14317-R10
Boral Roof Underlayments; (602) 269-2298 Revision 11:10/12/2018
Page 3 of 8
i
MEMO etc.
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Citadel Plus, Boral TileSeal 50HT, Boral TileSeal Boral MetaISeal"T GatorSeal:
➢ Plywood (unprimed or primed with ASTM D4 prim
Boral TileSeal'Tr or Boral MetalSeal"T:
➢ OSB (unprimed or primed with ASTM D41 primer).
Note: Refer to Section 5.6.4 for uplift limitations associated with direct -deck underloyment installations where the
overlying roof cover is adhesive -set tile roofing
5.6.2 Bond to Base Laver Uriderlavment:
Citadel Plus, Boral TileSeal 50HT, Boral TileSeal"T, Boral MetalSeal"T or GatorSeal:
➢ ASTM D226, Type II felt; Citadel Plus.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under adhesive -set tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested
in accordance with FBC 1504.3.1.
5.6.3 Bond to Other Substrate Tvpes: ,
Citadel Plus, Boral TileSeal 50HT, Boral TileSeal"T, Boral MetalSeal"T or GatorSeal:
➢ ASTM D41 primed metal (e.g., flashing metal, valley metal, etc.).
Boral TileSeal"T
➢ Huber Zip Deck (unprimed or primed with ASTM D41 primer); Dens Deck Prime.
Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval.
5.6.4 Wind Resistance for Underlayment Systems in Adhesive -set Tile Applications: FRSA/TRI April 2012 (04-12) does
not address wind uplift resistance of all underlayment systems beneath adhesive -set tile systems, where the
underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems
that are not addressed in FRSA/TRI April 2012 (04-12) and are used in adhesive -set tile applications. Maximum
Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the
ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer
to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads
#1 Maximum Design Pressure=-126.0 post:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
iil"Jurisdiction.
Primer: 1 (Optional) ASTM D41 to the plywood deck
Base Ply: ! Citadel Plus, self -adhered
Cap Sheet -,I Boral TileSeal"T or Boral MetalSealn self -adhered, and back -nailed within the selvedge -edge side laps
i using 12 ga. x 1Y<" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
#2 Maximum) Design Pressure = -142.5 psf:
Deck: I Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Ply, None
Cap Sheet: Boral TileSeal"T or Boral MetalSealn self -adhered and back -nailed within the selvedge -edge side laps
I using 12 ga. x 1%" ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c.
NEW ETC, LLC 1
Certificate of Authorization #32455
1
e EDITION (2017).FBC NON-HVHZ EVALUATION
Boral Roof Underlayments, (602) 269-2288
Evaluation Report M35710.12.10-Rll
FL14327-R30
Revision 11: IOIW2018
Page 4 of 8
MEMO etc.
6.5.4 Non -Tile Applications, to Base Sheet:
Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with
Boral Roofing published installation instructions and Section 6.4.
Install Boral TileSeal 50HT in accordance over ASTM D226, Type II felt or Citadel Plus with Boral Roofing published
installation instructions and Section 6.5.3, except end (vertical) laps, described below.
Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the fabric top surface, rolling the interface into place with a weighted roller.
6.6 pp'ator5eat: uew r✓ r� r w, ���''tti ::q`�yro.�y9f } ^fir'":: !i iA,.3.�r G". ey%�r Fi.
;�:t"r.-.t ..•, n.r:-sr�� � � �$� '�,",,".;?a.. •�.�' ., �� ti{!:w �.,rwJ:t:`+S::w',� 3L:,'): °r * � :.f: a t?=n��.ri.C�.affv�y`'ri '�. kaJ � tiJr'kr {i
6.6.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed.
6.6.2 Do not use GatorSeal on roof pitches less than 2.12,
6.6.3 Non -Tile applications, Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by'/ -inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with
a weighted roller.
Fasten the black selvedge edge to the deck with corrosion resistant roofing nails, nails & tin -tags or 1-inch diameter
plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and greater.
Overlap successive courses the entire width of the'black-selvedge area, minimum 3-inch.
- Seal end (vertical) laps using SBS Mastic under all�side (vertical) laps or any other laps where the self -adhering
bituminous underside is in contact with the granular or mineral top surface, rolling the interface into place with a
weighted roller, or using the Inverted Sheet Seam detailed in Boral Roofing published installation instructions.
6.6.4 Non -Tile Applications. to Base Sheet:
Install ASTM D226, Type 11 felt in accordance with Code requirements or install Citadel Plus in accordance with
Boral Roofing published installation instructions and Section 6.4.
Install GatorSeal overASTM D226, Type II felt or Citadel Plus in accordance with Boral Roofing published installation
instructions and Section 6.6.3 except end (vertical) laps, described below.
Apply SBS Mastic under all side (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the granular top surface, rolling the interface into place with a weighted roller.
r'' m} .;b` .;_.r�,,.*vi r+ ,+ ♦ {' tr. }.+>,ar,. y� .h4e1Yu�,�
6.7:Boral:Tile5eal..,�oY;BbraCMetalSeal�?`�r�.,�,��*��...............��,�.��*��.�z�....,,`>.�,,,,��3G_Y�u�-.�,`,��f.z . h � ...... :
6.7.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed.
6.7.2 Do not use Boral TagS ae I"Tor oral MetalSeal"T on roof pitches less than 2:12.
6.7.3 Non -Tile Applications. Direct to Deck:
st:ratel-primezwit4i-.A&TlWe41 primer and allow to dry prior to installation. Cut the membrane into
manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by %-inch.
Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the
exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller.
Fasten the black selvedge edge to the deck with roofing nails, nails & tin -tags or 1-inch diameter plastic or steel
cap nails spaced maximum 12-inch o.c. Overlap successive courses the entire width of the black -selvedge area,
minimum 3-inch.
Seal under all end (vertical) laps using approved mastic'or use Inverted Sheet Seam method detailed in Boral
Roofing published installation instructions.
NEMO ETC, LLC Evaluation Report M35710.12.30-Rll
eertijhate ofAuthorization #32455 0 EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R10
Boral Roof Underlayments, (602) 269-2288 Revision 11:10/12/2018
Page 7 of 8
NEMO l etc.
6.7.4 Non -Tile Applications, to Base Sheet:
Install ASTM D226, Type'll felt in accordance with Code requirements or install Citadel Plus in accordance with
Boral Roofing published installation instructions and Section 6.4.
Install Boral TileSeal"T or, Boral MetalSeal"T over ASTM D226, -Type II felt or Citadel Plus'in accordance with Boral
Roofing published installation instructions and Section 6.7.3, except end (vertical) laps, described below.
Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the'fabric top surface, rolling the interface into place with a weighted roller.
6.7.5 Tile Applications:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
j noted above as a guideline.
For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s),
Base Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1.
For adhesive -set tile applications, refer to Section 5.6.4 herein.
Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design
pressure requirements may not exceed -120 psf.
I
Refer to Section 5.8 for tile staging limitations. Battens must be used for all tile installations atop Boral TileSeal"T
or Boral MetalSeall with roof pitches of 2% to less than 3:12. Boral Roofing's Elevated Batten System or counter
battens are required!
As required -by the
this product.
Brentwood, NH
UL, I.I.C. —
NEW ETC, LLC
Certificate of Authorization #32455
I
Official or Authority Having Jurisdiction in order to properly evaluate the installation of
(631) 546-2458; Kanchi.Asrawala-Dokania@ul.com
- END OF EVALUATION REPORT -
Evaluation Report M35710.12.10-R11
e EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R10
Boral Roof Underlayments; (602) 269-2298 Revision 11: 20/12/2018
Page 8 of 8