Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE 4-12-184 GCJANNED BY FOSI FA@§9(080'nt FLORIDA ENEI Florida Departme RECEIVED APR 12 2018 ! L'CfL1e���ICt�( usiness a Ind Profe ODE FOR BUILDING CONSTRUCTION sional Regulation - Residential Performance Method Project Name: LABERGE RESIDENCE Builder Name: Street: LOT 2 REFUGE LANE Permit Office: CITY OF PORT ST LUCIE City, State, Zip: PORT ST LUCIE , FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types -(3394.2 sqft.) Insulation Area a. Concrete Block - Ext Insul, Exterior R=4.1 2341.80 ft2 2. Single family or multiple family Single-family b. Frame - Wood, Exterior R=19.0 735.00 ft' 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=11.0 317.33 R2 4. Number of Bedrooms 3 d. N/A 10. Ceiling Types (2590.0 sqft.) R= ft' Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2590.00 ft2 6. Conditioned floor area above grade (ft') 2590 b. N/A R= 112 R= ft' c. N/A Conditioned floor area below grade (ft') 0 11. Ducts R ft' 7. Windows (377.0 sgft.) Description Area �, a. Sup: Attic, Ret: Attic, AH: Garage 6 200 a_ U-Factor: Sgl, U=0.65 289.00 ft' SHGC: SHGC=0.25 12. Cooling systems kBtulhr Efficiency b. U-Factor: Sgl, U=0.65 86.00 ft' a. Central Unit 48.0 SEER:16.00 SHGC: SHGC=0.20 c. U-Factor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft, a. Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 1.500 ft. Area Weighted Average SHGC: 0.238 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (2590.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2340.00 ft2 b. Conservation features b. Raised Floor R=0.0 250.00 ft' None c. NIA R= ft' 15. Credits None Total Proposed Modified Loads: 89.18 PASS Glass/Floor Area: 0.146 Total Baseline Loads: 93.89 1 hereby certify that the plans and specifications covered by in with the Florida Energy Review of the plans and specifications covered by this O� C11E SI-AT, O� this calculation are compliance Code. calculation indicates compliance with the Florida Energy Code. s�, :'..:;' o ;t•r �:•.••" �� O iltd Before s completed --lam ! PREP ED Y: construction DATE this building will be inspected for compliance with Section 553.908 _ y_ ng, as designed, is in complianceG,�bYVLM�� I hereby certify that thU6�" Florida Statutes. with the Florida EnergOWNER/AGENT• BUILDING OFFICIAL: VG DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017 this project requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50 (11402.4.1.2). FILE COPY 9/29/2017 1:31 PM EnergyGauge@ USA - v5.1 Section R405.4.1 Compliant Software Page 1 of 6 0 FORM K4Ub-LUl4 (PROJECT Title: LABERGE RESIDENCE Bedrooms: I 3 Address Type: Street Address Building Type: User Conditioned 2590 d Area: Lot # Owner: Total Stories: 1 BloctJSubDivision: # of Units: 1 Worst Case[ No PlatBook: Builder Name. Rotate Angle: 0 Street: LOT 2 REFUGE LANE Permit Office: CITY OF PORT ST LUCIE Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: PORT ST LUCIE , FamlyType: Single-family FL, New]Existing: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp J Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2590 30004.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 2 162 1522.8 No 0 1 1 Yes Yes Yes 2 CLST 2 14 131.6 No 0 1 Yes Yes Yes 3 BEDROOM 3 162 1522.8 No 0 1 1 Yes Yes Yes 4 CLST 3 14 131.6 No 0 1 No Yes Yes 5 BATH 2 54 507.6 No 0 1 Yes Yes Yes 6 LAUNDRY 42 394.8 No 0 1 No Yes Yes 7 POWDER 30 282 No 0 1 No Yes Yes 8 LINEN 10 94 No 0 1 No Yes Yes 9 HALLWAY 117 1099.8 INo 0 1 No Yes Yes 10 OFFICE 140 1316 1 1 Yes Yes Yes 11 CLST 40 INo 376 tlo 0 1 Yes Yes Yes 12 MASTER BATH 238 2237.2 INo 0 1 Yes Yes Yes 13 MASTER WIC 220 2068 No 0 1 Yes Yes Yes 14 MASTER BEDROO 320 3008 Nc 0 1 1 Yes Yes Yes 15 GREAT ROOM 266 5054 No 0 1 Yes Yes Yes 16 KITCHEN 309 5871 Yes 0 1 Yes Yes Yes 17 FOYER 202 1737.2 No 0 1 Yes Yes Yes 18 LOFT 250 2650 No 0 1 Yes Yes Yes 9/29/20171:31 PM EnergyGauge® USA - v5.1 I- Section R405.4.1 Compliant Software Page 2 of 6 FOKM K4Ub-LUl4 FLOORS Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet # Floor Type Space 1 Slab -On -Grade Edge Insulation BEDROOM 2 24.9 fl 0 162 ft' ---- 1 0 0 2 Slab -On -Grade Edge Insulation CLST 2 2 It 0 14 ft' ---- 1 0 0 3 Slab -On -Grade Edge Insulation BEDROOM 3 20.9 ft 0 162 ft' __-_ 1 0 0 4 Slab -On -Grade Edge Insulation CLST 3 1 ft! 0 14 ft' ___- 1 0 0 5 Slab -On -Grade Edge Insulation BATH 2 6 it I 0 54 ft' ____ 1 0 0 6 Slab -On -Grade Edge Insulation LAUNDRY 1 ft 0 42 ft' 1 0 0 7 Slab -On -Grade Edge Insulation POWDER 1 ft I 0 30 ft' -___ 1 0 0 8 Slab -On -Grade Edge Insulation LINEN 1 ft I 0 10 ft' ____ 1 0 0 9 Slab -On -Grade Edge Insulation HALLWAY 1 ft i 0 117 ft' ____ 1 0 0 10SIab-On-Grade Edge Insulation OFFICE 10 ft 0 140 ft' ____ 1 0 0 11SIab-On-Grade Edge Insulation CLST 4 ft 0 40 ft' ____ 1 0 0 12SIab-On-Grade Edge Insulation MASTER BATH 22 ft 0 238 ft' 0 0 13SIab-On-Grade Edge Insulation MASTER WIC 41 ft 0 220 ft' ____ 1 0 0 14SIab-On-Grade Edge Insulation I MASTER BEDRO 32 ft 0 320 ft' __-- 1 0 0 15SIab-On-Grade Edge Insulation GREAT ROOM 14 ft 0 266 ft' __-_ 1 0 0 16SIab-On-Grade Edge Insulation KITCHEN 18 ft 0 309 ft' ____ 1 0 0 17SIab-On-Grade Edge Insulation FOYER 25 ft 0 202 ft' ____ 1 0 0 18Raised Floor LOFT i ___ I ____ 250 ft' 0 1 0 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area I Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 2897 fP I 0 ft' Light 0.6 No 0.9 No 20 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2590 ft' N N 9129/20171:31 PM EnergyGauge® USA - v5.1 - 'Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2014 CEILING f< Ceiling Type Space I R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) BEDROOM 2 20 Blown 162 ft2 0.1 Wood 2 Under Attic (Unvented) CLST 2 20 Blown 14 ft2 0.1 Wood 3 Under Attic (Unvented) BEDROOM 3 20 Blown 162 it' 0.1 Wood 4 Under Attic (Unvented) CLST 3 20 Blown 14 ft2 0.1 Wood 5 Under Attic (Unvented) BATH 2 20 Blown 54 ft' 0.1 Wood 6 Under Attic (Unvented) LAUNDRY 20 Blown 42 ft2 0.1 Wood 7 Under Attic (Unvented) POWDER 20 Blown 30ft' 0.1 Wood 8 Under Attic (Unvented) LINEN 20 Blown 10 ft' 0.1 Woad 9 Under Attic (Unvented) HALLWAY 20 Blown 117ft' 0.1 Wood 10 Under Attic (Unvented) OFFICE 20 Blown 140 ft' 0.1 Wood 11 Under Attic (Unvented) CLST 20 Blown 40 112 0.1 Wood 12 Under Attic (Unvented) MASTER BATH 20 Blown 238 ft2 0.1 Wood 13 Under Attic (Unvented) MASTER WIC I, 20 Blown 220 ft2 0.1 Wood. 14 Under Attic (Unvented) MASTER BEDRO , 20 Blown 320 IF 0.1 Wood 15 Under Attic (Unvented) GREAT ROOM 20 Blown 266 ft2 0.1 Wood 16 Under Attic (Unvented) KITCHEN 20 Blown 309 ft' 0.1 Wood 17 Under Attic (Unvented) FOYER 20 Blown 202 ft2 0.1 Wood 18 Under Attic (Unvented) LOFT I 20 Blown 250 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space p o _ 1 NE Exterior Concrete Block - Ext InsiBEDROOM 2 i 41 .1 13 0 9 4 121.3 ft' 0 0 0.6 0 _ 2 SE Exterior Concrete Block - Ext InstSEDROOM 2 41.1 12 0 9 4 112.0 ft' 0 0 0.6 0 3 NE Exterior Concrete Block - Ext Insul CLST 2 I.1 2 0 9 4 18.7 ft' 0 0 0.6 0 _ 4 SE Exterior Concrete Block - Ext InsiBEDROOM 3 4II1 12 0 9 4 112.0 ft' 0 0 0.6 0 5 SW Exterior Concrete Block - Ext InstSEDROOM 3 40 9 0 9 4 84.0 ft' 0 0 0.6 0 _ _ 6 NE Exterior Concrete Block - Ext Insul BATH 2 41I1 6 0 9 4 56.0 ft' 0 0 0.6 0 7 NE Exterior Concrete Block - Ext Insul OFFICE 4!1 10 0 9 4 93.3 ft' 0 0 0.6 0 _ 8 NW Exterior Concrete Block - Ext Insul CLST 4 I1 4 0 9 4 37.3 ft' 0 0 0.6 0 9 NE Exterior Concrete Block - Ext InsLMASTER BA 4.11 8 0 9 4 74.7 ft2 0 0 0.6 0 10 SE Exterior Concrete Block - Ext InsLMASTER BA 4.1 14 0 9 4 130.7 ft2 0 0 0.6 0 11 SE Exterior Concrete Block - Ext InsWASTER W 1 4.I1 11 0 9 4 102.7 ft' 0 0 0.6 0 _ 12 SW Exterior Concrete Block = Ext InsLMASTER W 1 4.) 21 0 9 4 196.0 ft' 0 0 0.6 0 _ 13 NW Exterior Concrete Block - Ext InsLMASTER WI 4.1 9 0 9 4 84.0 ft' 0 0 0.6 0 _ 14 SW Exterior Concrete Block - Ext InsLMASTER BE 4.1 16 0 9 4 149.3 W 0 0 0.6 0 _ 15 NW Exterior Concrete Block - Ext InsLMASTER BE 4.i. 16 0 9 4 149.3 ft' 0 0 0.6 0 _ 16 SE Exterior Concrete Block- Ext InsdIREAT ROO 4.1 14 0 19 0 266.0 ft' 0 0 0.6 0 _ 17 SE Exterior Concrete Block - Ext Insul KITCHEN 4.1, 15 0 19 0 285.0 ft2 0 0 0.6 0 _ 18 SW Exterior Concrete Block- Ext Insul KITCHEN 4.11, 3 0 19 0 57.0 ft' 0 0 0.6 0 _ 19 NW Exterior Concrete Block - Ext Insul FOYER 4.1' 25 0 8 6 212.5 ft' 0 0 0.6 0 _ 20 NE Exterior Frame - Wood LOFT 19 10 0 10 6 105.0 ft2 0 0.25 0.6 0 _ 21 SE Exterior Frame- Wood LOFT 19 25 0 10 6 262.5 ft' 0 0.25 0.6 0 22 SW Exterior Frame- Wood LOFT 19, 10 0 10 6 105.0 ft' 0 0.25 0.6 0 1 9/29120171:31 PM EnergyGaugeO USA - v5.1 - Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2014 WALLS - F- Cavity Width Height Sheathing Framing Solar Be ow Adjacent 5 ace P 23 NW Exterior Frame - Wood LOFT 19 25 0 10 6 262.5 ft2 0 0.25 0.6 0 NW Garage Frame - Wood OFFICE 11 24 9 4 224.0ft' 0 0 0.600000 0 _24 25 E Garage Frame - Wood FOYER 11 10 9 4 93.3 ft' 0 0 0.600000 0 WINDOWS Orientation shown is the entered, Proposed orientation. Overhang # Wall Ornt ID Frame Panes NFRC Jactor SHGC Area Depth Separation Int Shade Screening 1 SE 2 Metal Law-E Single Yes 0165 0.25 15.0 ft' 1 ft 6 in 1 ft 4 in None None 2 SE 4 Metal Low-E Single Yes 0 65 0.25 15.0 ft' 1 ft 6 in 1 ft 4 in None None 3 SW 5 Metal Low-E Single Yes 0.165 0.2 24.0 ft' 1 ft 6 in 1 ft4 in None None 4 NE 7 Metal Low-E Single Yes 0.65 0.25 15.0 ft' 1 ft 6 in 1 ft 4 in None None 5 SE 10 Metal Low-E Single Yes 0.I 5 0.26 15.0 W 1 ft 6 in 1 ft 4 in None None 6 SW 12 Metal Low-E Single Yes 0.65 0.25 9.0 ft' 1 ft 6 in 1 ft 4 in None None 7 SW 14 Metal Low-E Single Yes 0.65 0.25 24.0 fF 1 ft 6 in 1 ft 4 in None None 8 NW 15 Metal Low-E Single Yes 0.65 0.25 30.0 ft' 1 ft 6 in 1 ft 4 in None None 9 SE 16 Metal Law-E Single Yes 0.65 0.2 48-0 ft' 1 it 6 in 1 ft 4 in None None 10 SE 17 Metal Low-E Single Yes 0.65 0.2 16.0 ft' 1 ft 6 in 1 ft 4 in None None 11 SE 17 Metal Low-E Single Yes 0.65 0.25 48.0 it, 1 ft 6 in 1 ft 4 in None None 12 NW 19 Metal Low-E Single Yes 0.65 0.25 30.0 ft' 1 ft 6 in 1 ft 4 in None None 13 NW 19 Metal Low=E Single Yes O.iS 0.25 16.0 fF 1 ft 6 in 1 ft 4 in None None 14 NW 19 Metal Low-E Single Yes 0.6I5 0.25 24.0 ft' 1 ft 6 in 1 It 4 in None None 15 NW 23 Metal Low-E Single Yes 0.6I5 0.25 48.0 ft' 1 ft 6 in 1 ft 4 in None None GARAGE I # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 504 if 384 ft' I 34 ft 9 ft 11 INFILTRATION I # Scope Method SLA CFM 50I ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000515 i 3500.5 I 192.17 361.41 .3761 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP:1 34 kBtu/hr 1 sys#1 9/29/2017 1:31 PM EnergyGauge@ USA - v5.1 - Section R405A.1 Compliant Software Page 5 of 6 FORM R4Ub-ZU14 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 48 kBtu/hr 1440 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EFL Cap Use SetPnt Conservation 1 Electric None Garage 0.98 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC I Collector Storage Cert # Company Name SystemlIModel # Collector Model # Area Volume FEF None None IDUCTS I — Supply -- — Return -- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area i Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 200 ft2 Attic 20 ft' Default Leakage Garage (Default) c(DefauR) c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans II Cooling Jan Feb Mar Jan Feb Mar �X� Apr May Jun Jul rj AugSe I ' ri Oct Nov N Dec Dec VH enting Jan Feb Mar Apr May l Jun Jul Aug Sep Oct Nov Thermostat Schedule: HERS 2006 Reference Hours I! Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 PM 80 78 78 78 I 78 78 78 80 80 80 78 78 78 78 80 78 78 80 78 80 78 80 78 Cooling (WEH) AM 78 PM 80 78 78 78 78 78 78 80 80 80 78 78 78 78 80 78 78 80 78 80 78 80 78 Heating (W D) AM 65 PM 68 65 65 65 �I 65 65 65 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 PM 68 65 65 65 65 65 65 68 68 68 I 68 68 68 68 68 68 68 68 68 68 68 68 68 9/29/20171:31 PM EnergyGauge@ USA - v5.1 - Section R405.4.1 Compliant Software Page 6 of 6 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: LABERGE RESIDENCE Builder Name: Sheet: LOT 2 REFUGE LANE Permit Office: CITY OF PORT ST LUCIE City, State, Zip: PORT ST LUCIE , FL, Permit Number: Owner: I Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop 'down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend'. behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. [Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 9/29/2017 1:32 PM EnergyGaugeO USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 1 7 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the EnergyPerformance Index, the more efficient the home. LOT 2 REFUGE LANE, PORT ST LUCIE, FL, 1. New construction or existing New (From Plans) I 9. Wall Types Insulation Area a. Concrete Block - Ext Insul, Exterior R�.1 2341.80 ftz 2. Single family or multiple family Single-family b. Frame - Wood. Exterior R=19.0 735.00 ft 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=11.0 317.33 ft' 4. Number of Bedrooms 3 d. N/A 10. Ceiling Types R= ft' Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2590.00 ft' 6. Conditioned floor area (ft') 2590 b. N/A R= ft' ft' c. N/A R= 7. Windows" Description Area Ducts R ft' a. U-Factor: Sgl, U=0.65 289.00 ft' a. a. Sup: Attic, Ret: Attic, AH: Garage 6 200 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 88.00 ft' SHGC: SHGC=0.20 12. Cooling systems kBtu/hr Efficiency c. U-Factor: NIA ft' a. Central Unit I 48.0 SEER:16.00 SHGC: d. U-Factor: N/A ft' I 13. Heating systems kBtulhr Efficiency SHGC: a. Electric Strip Heat 34.0 COP:1.00 Area Weighted Average Overhang Depth: 1.500 ft. i Area Weighted Average SHGC: 0.238 8. Floor Types Insulation Area 14. Hot water systems Cap: 40 gallons i a. Slab -On -Grade Edge Insulation R=0.0 2340.00 ft' a. Electric EF: 0.98 b. Raised Floor R=0.0 250.00 ft' b. Conservation features c. N/A R= ft' None 15. Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building -TglvsrAT: Construction through the above energy saving features which will be installed (or exceeded) o Py""p"a� in this home before final inspection. Otherwise, a new EPL'Display Card will be completed yw ,,,.. _ _ r .n based on installed Code compliant features. Builder Signatur :- _ Date:..q-- S;-_ Ifs Address of New Home: City/FL Zip:,'15aV5'6/u 1j�Y3C� SOD 3y9S7 'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. "''Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 9/29/2017 1:32 PM EnergyGauge@ USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 1