Loading...
HomeMy WebLinkAboutINSULATION & INSTALLATION CERTIFICATES ' RECEIVSO sl JUL 3 0 2019 INSULATION INSTALLATION CERTIFICATE ST..Lucie County, Permitting South Florida Select Homes Corp TO: _ LOT--- BLOCK:. SE- JOBd: 115312 JOB,NAME: Norton Res i JOB ADDRESS: 13185 S Indian River Dr Jensen Beach, FL 34956 The undersigned hereby certifies that insulation has Ibeen installed at .the above described property as follows; 1, Exterior, CBS walls have. been insulated with .........:..................Check one S on cellulose (.) piny .. to a thicknes$. of WA inches, which, thickness, according to the. ( );Fiibergiass blankets manufacturer, O Aluminum Foil Density N/A wil[yield an "R" value.of O Riold Exterior Frame walls have been insulated with .. ......... ........Check one ( ), Spray.on cellulose to a thickness -of 5 inches, which; thickness, according to the O Fiberglass blankets manufacturer, SES Sucraseal ! O Aluminum Foil Density iN/A will yield an "R" value of 19 ( 4-Other spray'Foam 2. Main Ceilings.have been insulated with I .......Check one. ( ) Fiber lass blankets g to a thickness of 5.25 inches, which thickness according to the ( ) Fiberglass loose fill manufacturer,. SES Sucraseal ( ) Aluminum Foil Density WA will'yield an "R" value of �20 (x)'Other Ispray foam Floor Over No A/C 6 been insulated with ... .....................Check one O Fiberglass blankets toa, thickness of 5 inches, which thickness according to the O Fiberglass loose fill: manufacturer; SES Sucraseal O Aluminum Foil Density . N/A will yield an "R" value of 119 (X) Other Ispray foam 3.. Interior knee walls have:been "insulated with........ . .........:..:.....Check one ( ) Fiberglass 'blankets to a thickness of inches, which. thickness, according to the ( ) Polyurethane manufacturer, ( ) Spray on cellulose Density N/A will yield an "R" value of j { ) Other Spray Foam 4. Garage partition walls of conditioned living areas h� ave been insulated with ......... .............I. .................Check one ( ) Fiberglass,blankets. to a thickness of inches, which thickness, according to the ( ) Spray on cellulose ;manufacturer; ( ) Polyurethane Density WA will yield an "R" value ofl ( I Other Aluminum Foil' MULTI FAMILY RESIDENTIAL. CONSTRUCTION: ONLY-, The common (party) walls separating different tenants shall be insulated as follows- Frame/Metal "stud.wails R611 (Min.); CBS or Concrete walls R-3 (Min:),;'hy-Energy Code requirements: 'See Energy Code Rev..1187, paragraph'903.2(b), on page 947, latest edition. These "minimums levels of insulation'�'are not included in the Energy Calculations, but shall be'installed in the field. -NOTE; Densities: ofsprayed on, loose. fill, -or any other composed -on site insulation shall be the P.C.F. (lb%ft3) average of three (3) "DRY SAMPLES" of actual installation, Insulation Contractor insulation ContractorSignatnre MCIN6231 7/16/2019 Insulation Contractor CC# Date of. Certification Builder's Name- Builder's CC# Not blic Mal a%rL KELLY LYOU%G ;`�: `�dtv'�uili:-S;ateclFlorida ; �` b GG.193242 .. �• =J Com nissior ? MyGmm &g+msJul1,2022; '. dcrdedlH4B fl•tiaicr21%curyMul, I