HomeMy WebLinkAboutINSULATION & INSTALLATION CERTIFICATES
' RECEIVSO
sl JUL 3 0 2019
INSULATION INSTALLATION CERTIFICATE
ST..Lucie County, Permitting
South Florida Select Homes Corp
TO: _ LOT--- BLOCK:.
SE-
JOBd: 115312 JOB,NAME: Norton Res
i
JOB ADDRESS: 13185 S Indian River Dr Jensen Beach, FL 34956
The undersigned hereby certifies that insulation has Ibeen installed at .the above described property as
follows;
1, Exterior, CBS walls have. been insulated with .........:..................Check one
S on cellulose
(.) piny ..
to a thicknes$. of WA inches, which, thickness, according to the.
( );Fiibergiass blankets
manufacturer,
O Aluminum Foil
Density N/A wil[yield an "R" value.of
O Riold
Exterior Frame walls have been insulated with .. ......... ........Check one
( ), Spray.on cellulose
to a thickness -of 5 inches, which; thickness, according to the
O Fiberglass blankets
manufacturer, SES Sucraseal !
O Aluminum Foil
Density iN/A will yield an "R" value of 19
( 4-Other spray'Foam
2. Main Ceilings.have been insulated with I .......Check one.
( ) Fiber lass blankets g
to a thickness of 5.25 inches, which thickness according to the
( ) Fiberglass loose fill
manufacturer,. SES Sucraseal
( ) Aluminum Foil
Density WA will'yield an "R" value of �20
(x)'Other Ispray foam
Floor Over No A/C 6 been insulated with ... .....................Check one
O Fiberglass blankets
toa, thickness of 5 inches, which thickness according to the
O Fiberglass loose fill:
manufacturer; SES Sucraseal
O Aluminum Foil
Density . N/A will yield an "R" value of 119
(X) Other Ispray foam
3.. Interior knee walls have:been "insulated with........ . .........:..:.....Check one
( ) Fiberglass 'blankets
to a thickness of inches, which. thickness, according to the
( ) Polyurethane
manufacturer,
( ) Spray on cellulose
Density N/A will yield an "R" value of j
{ ) Other Spray Foam
4. Garage partition walls of conditioned living areas h� ave been
insulated with ......... .............I. .................Check one
( ) Fiberglass,blankets.
to a thickness of inches, which thickness, according to the
( ) Spray on cellulose
;manufacturer;
( ) Polyurethane
Density WA will yield an "R" value ofl
( I Other Aluminum Foil'
MULTI FAMILY RESIDENTIAL. CONSTRUCTION: ONLY-, The common (party) walls separating
different tenants shall be insulated as follows- Frame/Metal "stud.wails R611 (Min.); CBS or Concrete walls
R-3 (Min:),;'hy-Energy Code requirements: 'See Energy Code Rev..1187, paragraph'903.2(b), on page 947,
latest edition. These "minimums levels of insulation'�'are not included in the Energy Calculations, but shall
be'installed in the field.
-NOTE; Densities: ofsprayed on, loose. fill, -or any other composed -on site insulation shall be the P.C.F.
(lb%ft3) average of three (3) "DRY SAMPLES" of actual installation,
Insulation Contractor insulation ContractorSignatnre
MCIN6231 7/16/2019
Insulation Contractor CC# Date of. Certification
Builder's Name- Builder's CC# Not blic
Mal
a%rL KELLY LYOU%G
;`�: `�dtv'�uili:-S;ateclFlorida
; �` b GG.193242
.. �• =J Com nissior
? MyGmm &g+msJul1,2022;
'. dcrdedlH4B fl•tiaicr21%curyMul,
I