HomeMy WebLinkAboutSEWAGE CONSTRUCTION INSPECTION& FINAL APPROVALI-). -erAWNFID, 60 1 N-IVA3ell,49 .. . n4-13VAo*7r__ LOT: 14 BLOCK: SUBDIVISION Carlton Countn Estates iD# : 3211-701-0016-000-4 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION I SETBACKS [ ] [01] TANK SIZE (1] 1090.00 [i] [ ] [271 SURFACE WATER FT [ ] [021 TANK MATERIAL Polypropylene [ ] [281 DITCHES FT [ ] [031 OUTLET DEVICE I [ ] [291 PRIVATE WELLS 75_ FT [ ] [04] MULTI -CHAMBERED [ Y N ] [ ] [301 PUBLIC WELLS FT [ ] [05] OUTLET FILTER POlylok PL-68 I [ ] [311 IRRIGATION WELLS FT [ ] [061 LEGEND 1. 70-143-11QC4 2. [ ] [321 POTABLE WATER 10 FT [ ] [071 WATERTIGHT [ ] [331 BUILDING FOUNDATIONS 14 FT [ ] [081 LEVEL [ ] [34] PROPERTY LINES 100 FT [ ] [09] DEPTH TO LID [ ] [35] OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ j [101 AREA [11 679,2 [21 SQFT [ ] [361 DRAINFIELD COVER [ ] [11] DISTRIBUTION BOX HEADER X. [ ] [371 SHOULDERS [ ] [121 NUMBER OF DRAINLINES 1. 66 2. [ ] [381 SLOPES [' ] 1131 DRAINLINE SEPARATION [ ] [391 STABILIZATION 07/26/2019 [ ] [14] DRAINLINE SLOPE [ ] [151 DEPTH OF COVER ADDITIONAL INFORMATION [ ] [16] ELEVATION [ ABOVE / BELOW ]BM 7.00 [ ] [40] UNOBSTRUCTED AREA [ ] 1171 SYSTEM LOCATION [ ] (411 STORMWATER RUNOFF [ ] 118] DOSING PUMPS j [ ] [42] ALARMS [ ] [19] AGGREGATE SIZE [ ] [431 MAINTENANCE AGREEMENT [ ] [20] AGGREGATE EXCESSIVE FINES [ ] [44] BUILDING AREA [ ] [21] AGGREGATE DEPTH i [ ] [45] LOCATION CONFORMS WITH SITE PLAN I ] [461 FINAL SITE GRADING L FILL / EXCAVATION MATERIAL [ ] [471 CONTRACTOR MICHAEL W STUHR (ASHTO [ ] FILL AMOUNT . i [ ] 1481 OTHER INFILTRATOR Qu1ck4 Plus EQ36 LP [ ] [221 31. FILL TEXTURE [ ] [24] EXCAVATION DEPTH ABANDONMENT [ ] 1251 AREA REPLACED [ ] [49] TANK PUMPED [ j (261 REPLACEMENT MATERIAL [ ,] [501 TANK CRUSHED & FILLED Comments: Comments are on page 2. /i St. Lucie CHD DATE: 06/06/2019 CONSTRUCTION I APPROVED DISAPPROVED ]I: Environmental Specialist II B& J Ingram (ENVIRONMENTAL HEALTH) FINAL SYSTEM [ AppROVED / St. Lucie CHD DATE: 07/26/2019 DISAPPROVED ]: i EavironmentaFSpeclallst I Hunter A Collier (Florida Department of Has (Explanation of Violations on following page) I DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Page 2 of 3 Incorporated: 64E-6.003, FAC I EH Database v 1.0.1 AP1370875 EID1888068 I Violation Number Comments N STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT CONSTRUCTION INSPECTION Comment APPLICATION #:AP1370875 PERMIT #:56-SF-1888068 DISPOSAL SYSTEM DOCUMENT #: FI1312507 FINAL APPROVAL DATE PAID:10/29/2018 FEE PAID:515.00 RECEIPT #:56-PID-3781461 The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 400 gpd. New ST, filter, and 6x10 long BED DF installed. No violations, system ok to cover. Contractor notified by phone. Needs final inspection for potable well inspection/setback, potable water line setback, mound system, and final site grading. Well inspected during final Inspection. Final system approved. Emailed to contractor and building department. DH 4016, 08/09 (Obsoletes all previous editions w�lich may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1I370875 EID1888068