HomeMy WebLinkAboutEVALUATION REPORTIN SCANNEDLP,-0-5 i BY ST. LUCK' COUi�'TY BII[Li?_ . _ .. SION REV EWED FOR CO AO (MP EVAL ORT OF REVIEIVE BY UNION CORRUGATING COMPANYDATE �26 GA. 5V PANEL' PLANS AND PERMIT MUST BE KEPT ON JOD OR NO INSPECTION WML FLORIDA BUILDING CODE 6TH EDITION (2017) FLORIDA/PRODUCT APPROVAL FL 20484.1-R1 ROOFING THESE PLANS AND ALL PROPOSED WORK AL ROOFING ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMM WITH AI-!lMCANA 09PR6a Prepared For: Union Corrugating Company 701 S. King St. Fayetteville, NC 28301 Telephone: (910) 483-0479 Fax: (910) 483-1091 Prepared By: Bala Sockalingam, Ph.D., P.E. rida Professional Engineer #62240 1216 N Lansing. Ave., Suite C Tulsa, OK 74106 Telephone: (918) 492-5992 FAX: (866) 366-1543 CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSISJUN OF THE CONTRACTOR OFREWRO This report consists of Evaluation Report (3 Pages including cover) Installation Details (1 Page) Load Span Table (1 Page) Report No. C2175-1 Date: 8.23.2017 w FL 20484.1-R 1 C2175-1 8.23.2017 Page 2 of 3 Manufacturer: Union Corrugating Company Product Name: 5V Panel Panel Description: 24" wide coverage with (5) 1/2" high ribs Materials: Minimum 26*., 80 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). J Deck Description: Min. 15/32"' thick APA rated plywood or min. 3/a" thick wood plank (min SG of 0.42) for new and existing constructions. Designed by others andiinstalled as per FBC 2017. , New Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1. ReQuiredifor new construction. Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For reroofing (Optional) construction only. Slope: 1/2:121or greater in accordance with FBC 2017 Section 1507.4.2 Design Uplift Pressure: 71.0 psf @ fastener spacing of 24" o.c. (Factor of Safety = 2) 169.0 •psf @ fastener spacing of 6" o.c. Panel Attachment: #10'15 x 2" long wood screw with washer At interior @ max 12" o.c. across panel width through panel rib At panel ends @ max 6" o.c. across panel width through panel flat and rib Test Standards: Roof assembly tested in accordance with UL580-06 `Uplift Resistance of Roof Assemblies' & UL1897-04 `Uplift Tests for Roof Covering v r --I--- Test Equivalency: The test procedures in UL 1897-04 comply with test procedures ,prescribed in UL 1897-12. Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1507.4. Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. The design pressure for reduced fastener spacing may be computed using rational analysis prepared by a Florida Professional Engineer or based on Union load span table. This evaluation report is ,, Supporting Documents FL 20484.1-R1 C2175-1 8.23.2017 Page 3 of 3 not applicable in 14, igh Velocity Hurricane Zone. Refer to current NOA for use of this product in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Section 1505 and current approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. UL580 & UL189I Test Reports Farabaugh Engineering and Testing Inc. Project No. T1971 16, Reporting Date 5/12/16 PANEL OVERLAP NEW UNDERLAYMENT PANEL FASTENER SPACING PER ALLOWABLE ROOF PANEL SEE DETAIL 2 SEE DETAIL 1 � "...—SEE � � UPUFf LOAD TABLE n n ( J J I EXISTING UNDERLAYMENT EXISTING SHINGLES DECK ATTACHMENT AND PLYWOOD 15/32' THICK (MIN. ) (OPTIONAL) (OPTIONAL) SUPPORTS MUST BE DESIGNED AND INSTALLED x 8Y OTHERS � NEW UNDERLAYME EXISTING UNDERLAYI (OPTIONAL) DETAIL 1 SCREW 2' LONG WOOD SCREW WITH WASHER NEW UNDERLAYMENT EXISTING UNDERLAYMENT V (OPTIONAL) DETAIL 2 IS/32' THICK (MIN.) 26 GA. PANEL 'j EXISTING SHINGLES la/l (OPTIONAL) PLYWOOD 15/32" THICK. (MIN.) a � 4 GENERAL NOTES: 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE^ n Y9 FLORIDA BUILDING CODE (FBC). o 2. ROOF PANELS SHALL BE MINIMUM 26 GA. EFFECTIVE COVERING WIDTH Or e PANEL = 24". - u 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOAD TABLE. S. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. I i I UNION CORRUGATING COMPANY 5V Panel Uplift Loads (Mui 26 ga.) Description Fastener Spacing Allowable Uplift along Panel Length. Load i(in) (psf) Coverage width: 24" 6 169.0 8 158.1 110 147.2 Panel Fasteners #10-15 hex head screws with 112 136.3 sealed washer 114 121..7 16 -_ 106.5 Panel fasteners spaced at 12" 118 94.7 o.c. across panel width 120 85.2 through ribs. —'— -- - -- 77.5 �24 71.0 Notes: I 1. The bold numbers indicate design loads calculated 2. Panels must be installed as per. Evaluation Report 1 from test data with safety factor of 2. 120484.1 and'Union current installation procedure. I 4pe®eeae'ae@d®�o G�p,LI N q sosvo .. 0 62 .�;ti� • N oLU: I ;W F � �4 1216 N Lansing Ave., Suite C F e S l �` ���a Bala Sockalingam, Ph.D., P.E. Tulsa, Ok 74106 FL 62240 918 492 5992