HomeMy WebLinkAboutNOASCANNED
MIA h1i•I 1M
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA)
www.miamidade.cov/economv
Gardner Asphalt CorporationnNTS
4161 W. 7`I' Avenue
ARE THE RESPONSISIM OF THE
Tampa, FL. 33605 I
CONTRACTOR OF RECORD
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date sta
(In Miami Dade County) and/or the AHJ (in areas other
or material tested for quality assurance purposes. If this
manufacturer will incur the expense of such testing and
of such product or material within their jurisdiction. RI
determined by Miami -Dade County Product Control Sei
of the applicable building code.
This product is approved as described herein, and has b�
including the High Velocity Hurricane Zone of the Flor:
DESCRIPTION: Gardner Underlayments
LABELING: Each unit shall bear a permanent label
statement: "Miami -Dade County Product Control Apl
RENEWAL of this NOA shall be considered after a rI
in the applicable building code negatively affecting the
i below. The Miami -Dade County Product Control Section
an Miami Dade County) reserve the right to have this product
duct or material fails to perform in the accepted manner, the
AHJ may immediately revoke, modify, or suspend the use
reserves the right to revoke this acceptance, if it is
)n that this product or material fails to meet the requirements
designed to comply with the Florida Building Code
Building Code.
the manufacturer's name or logo, city, state and following
I", unless otherwise noted herein.
application has been filed and there has been no change
nance of this product.
TERMINATION of this NOA will occur after the exp ration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Offici1HESE PLANS AND ALL PROPO ED WORK
This NOA revises NOA# 15-0707.09 and consists of pages 1 through 5. ARE SUBJECT TO ANY CORRECTIONS
The submitted documentation was reviewed by Alex Tigera. REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH AL APPLICA[ 14 COALS,
ST. LUCTY COUNTY RUIT `ISION
RFV F1N ED FOR CO, NOA: 17-0427.10
MIAMI•DADECOUNTY REV1EIi' D BY Expiration Date: 03/28/18
DATE 30 6/1Approval Date: 08/31/17
PLANS AND PERMIT ST BE KEPT ON JOB 059
P 1
OR NO INSPECTION WILL BE MADE,
ROOFING COMPONENT APPROVAL
Category Roofing
Sub -Category: Underlayment
Material: Asphalt
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test
Product
Product Dimensions
Specification
Description
APOC Tuff -Felt 26 36" x 72' rolls
ASTM D 226 Type II
Asphalt Saturated Felt underlayment, 2
Manufacturing
square #30.
Location 91 2
Unite R20 36' x 72' rolls
ASTM D 226 Type II
Asphalt Saturated Felt underlayment, 2
Manufacturing
square #30.
Location #1, 2
APOC Tuff -Felt 46 36" x 144' rolls
ASTM D 226 Type I
Asphalt Saturated Felt underlayment, 4
Manufacturing
square #15.
Location #1, 2
United FGUR10 36" x 144' rolls AS M D 226 Type I Asphalt Saturated Felt underlayment, 4
Manufacturing square #15.
Location #1, 2
United FGUR70
18" x 72' rolls AS iM D 226 Type II
Asphalt Saturated Felt underlayment, 1
Manufacturing
square #30.
Location #1, 2
GatorSkin
42" x 285.8' rolls AS M D 226 Type II
Synthetic roof underlayment comprised
Manufacturing
of layers of polyolefin film.
Location #3
Weather -Armor CX-L
37.25" x 145' rolls ASTM D 226 Type II
High strength hybrid underlayment
Manufacturing
comprised of two layers of polyolefin and
Location #3
polyester synthetic fabric with a thin layer
of modified bitumen between the two
plies.
Weather -Armor SB-1
36" x 65' 8" rolls i ASTM D 1970
Glass fiber reinforced, polymer modified
Manufacturing
asphalt, granulated self -adhered
Location #4
I
underlayment.
Weather -Armor HT3
i
39" x 65' 8" rolls i ASTM D 1970
60-mils thick (nominally), self -adhering
Manufacturing
membrane composed of elastic polymers,
Location #4
bitumen, glass reinforcements and a cross
laminated sheet surfacing.
NOA: 17-0427.10
MIAMI•DADE COUNTY
Expiration Date: 03/28/18
Approval Date: 08/31/17
Page 2 of 5
I
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product Dimensions Suecification Description
Weather -Armor FT3 39" x 65' 8" rolls ifAS 103 60-mils thick (nominally), self -adhering
Manufacturing
membrane composed of elastic polymers,
Location #4 I bitumen polyester and glass
reinforcement.
MANUFACTURING LOCATIONS:
1. Tacoma, WA.
2. Eutaw, AL.
3. Hangzhou, China.
4. Springville, AL.
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Report
Date
PRI Construction Materials
GGI-100-02-01
ASTM D 226
06/22/12
Technologies
GGI-101-02-01
ASTM D 226
06/22/12
GGI-132-02-01
ASTM D 226
04/28/15
GGI-176-02-01
ASTM D 226
09/26/16
GGI-178-02-01
ASTM D 1970
10/25/16
GGI-194-02-01
ASTM D 1970
08/04/17
GGI-196-02-01
TAS 103
08/08/17
APPROVED ASSEMBLIES:
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood
System E(1): Anchor sheet mechanically
Anchor Sheet: One or more plies of APOC Tuff
Weather -Armor CX-L with a mii
deck with approved nails and tin
rows fastened at 12 inches o.c. rr.
90 degrees to the roof deck.
to deck.
26, United FGUR20, United FGUR70, GatorSkin, or
n 4" headlap and a 6" end lap mechanically fastened to
6 inches o.c. minimum at all laps and three staggered
.gym in the field of the roll. Nails shall be driven flush and
Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry
slate, metal roof applications, and as an anchor sheet in roof tile applications. Must Comply with
applicable Roofing Application Standards and Building Codes.
MIAMI•DADE COUNTY
NOA: 17-0427.10
Expiration Date: 03/28/18
Approval Date: 08/31/17
Page 3 of 5
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(2): Anchor sheet mechanically fastened to deck.
Anchor Sheet: Minimum 2 plies or more of APOCITuff-Felt 46, or United FGUR10 with a minimum 19"
headlap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6
inches o.c. minimum at all laps andl three staggered rows fastened at 12 inches o.c. minimum in
the field of the roll. Nails shall be driven flush and 90 degrees to the roof deck.
Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry
slate, metal roof applications, and as an anchor sheet in roof tile applications. Must Comply with
applicable Roofing Application Standards and Building Codes.
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(3): Anchor sheet mechanically fastened to deck, membrane adhered.
Anchor Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" headlap and a
6" end lap mechanically fastened }o deck with approved nails and tin caps 6" o.c. at the side lap
edge and in a grid pattern spaced �2" o.c. in the field of the roll.
Membrane: One or more plies of Weather -Armor SB-1, or Weather -Armor HT' self -adhering membrane
adhered to the anchor sheet with a minimum 3" headlap and 6" end lap.
Surfacing: Shall be acceptable for use in app I roved asphaltic shingles, wood shakes, & shingles, quarry
slate, and metal roof applications. Must Comply with applicable Roofing Application Standards
and Building Codes.
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(4): Anchor sheet mechanically fastened to deck, membrane adhered.
Anchor Sheet: One or more plies of ASTM D 21N Type II or ASTM D 2626 with a minimum 4" headlap and a
6" end lap mechanically fasteneto deck with approved nails and tin caps 6" o.c. at the side lap
edge and in a grid pattern spaced 12" o.c. in the field of the roll.
i
Membrane: One or more plies of Weather -Armor FT3 self -adhering membrane adhered to the anchor sheet
with a minimum 3" headlap and 6" end lap.
i
Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood. shakes, & shingles, quarry
slate, metal roof, and mechanically fastened roof tile applications. Must Comply with applicable
Roofing Application Standards,I and Building Codes.
NOA: 17-0427.10
Expiration Date: 03/28/18
Approval Date: 08/31/17
Page 4 of 5
LABELING:
All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city,
state and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County
Product Control Seal as shown below. ;
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by
1. This Notice of Acceptance.
2. Any other documents required by the Building 0
the installation of this material.
LIMITATIONS:
of the following:
or applicable building code in order to properly evaluate
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance
with applicable building code.
3. Weather -Armor SB-1, and Weather -Armor H shall not be hot mopped; refer to manufacturer's published
literature for product compatibility.
4. Gardner Underlayments listed herein are components used in roof assemblies. Roof assemblies are approved
under specific assembly Notice of Acceptance.
5. APOC-Tuff Felt 26, United FGUR20, APOC-Tuff Felt 46, United FGUR10, United FGUR70, GatorSkin,
Weather Armor CX-L, and Weather -Armor SBI-1 listed herein shall not be left exposed as a temporary roof
for longer than 30 days of application.
6. Weather -Armor HT and Weather -Armor FT listed herein shall not be left exposed as a temporary roof for
longer than 180 days of application.
7. Gardner Underlayments listed herein may be used with any approved roof covering Notice of Acceptance
listing Gardner Underlayments listed herein as la component part of an assembly in the Notice of Acceptance.
If Gardner Underlayments listed herein is not listed; a request may be made to the Authority Having
Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that
appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire
testing results.
8. For fire classification of specific roof assemblies using Gardner Underlayments listed herein refer to a
current Approved Roofing Materials Directory for fire ratings of this product.
9. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
QM[AM-DADERMOUNTY
NOA: 17-0427.10
Expiration Date: 03/28/18
Approval Date: 08/31/17
Page 5 of 5