HomeMy WebLinkAboutNOA 5-3-18MAM I sly MIANII-DARE COUNTY
((,(��da�1 PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMI CES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) � l D� -eq �,_ www.mianddade.eov/econorny
Q ST. LUCIE COUNTY � �ZLc� cr�� L'
3M Center Building 0220-05-E-06 REVIEWED FOR OMPLIANCE/IN ISION
St. Paul, MN. 55144-1000 REVIEW ' ��
DATE
PLANS AND PERMIT MUST BE K SCOPE: SITE OR NO INSSP CT ON JOB
This NOA is being issued under the applicable rules and regulafonTl%(��rft► h%EUst,�onstruction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION�3I _110am oOf�T•ile dhesiyeRTA.I�
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a 'renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion
of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the
manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
FASTENERS OR ATTACHMENTS
This NOA renews NOA# 14-0805.02 and consists of pages 1 through 8.
CONCEALED
ARE THE RESPONSIBILITY OF THE
e1(3NTRACTOR OR RECORD
The submitted documentation was reviewed by Alex Tigera.
x 1P.T
NOA No.: 15-1201.04
MM MI -DARE COUNTY
Expiration Da e: 01/03/21
Approval Date: 12/31/15
THESE PLANS AND ALL PROPOSED WORK
Page 1 of 8
ARE SUBJECT TO ANY CORRECTIONS
BY FIELD INSPECTORS THAT
TO
FILEREQUIRED
COPY
MAY BE NECESSARY IN ORDER
COMPLY WITH ALL APPLICABLE CODES.
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves 3M Foam Roof Tile Adhesive RTA-1 as: manufactured by 3M Company as described below in this
Notice of Acceptance. For the locations where the pressure requirements, as determined by applicable building code,
do not exceed the design pressure values obtained by calculations in compliance with RAS 127. For use with approved
flat, low, and high profile roof tile systems using 3M Foam Roof Tile Adhesive RTA-1.
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test
Specifications
3M Foam Roof Tile N/A TAS 101
Adhesive RTA-1 j
PRODUCTS MANUFACTURED BY OTHERS:
Product Description
Single component polyurethane foam roof tile
adhesive.
Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment
resistance values with the use of 3M Foam Roof Tile Adhesive RTA-1 roof tile adhesive.
MANUFACTURING LOCATION:
1. Norton, OH.
PHYSICAL PROPERTIES:
Proper Test Results
Density ASTM D 1622 1.951bs./ft.3
Compressive Strength ASTM D 1621 7.8 psi
Tensile Strength ASTM D 1623 15 PSI Parallel to rise
Water Absorption ASTM D 2842 4.6 Lbs./Ft2
Moisture Vapor Transmission ASTM E 96 1.94 Perm / Inch
Dimensional Stability ASTM D 2126 +0.89% Volume Change @ 700 C., 2 Weeks
Closed Cell Content ASTM D 2856 54.1%
Note: The physical properties listed above are presented as typical average values as determined by
accepted ASTM test methods and are subject to normal manufacturing variation.
NOA No.: 15-1201.04
Expiration Date: 01/03/21
Approval Date: 12/31/15
Page 2 of 8
I
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Report
Date
Southwest Research Institute
i
01-1208-025
ASTM E 108
06/16/98
PRI Construction Materials
FOP-009-02, 10
Physical Properties
12/14/10
Technologies, Inc.
FOP-009-02-01
TAS-101
11/8/10
FOP-009-02 02
TAS-101
11/4/10
FOP-009-02703
TAS-101
11/8/10
FOP-009-02704
TAS-101
11/8/10
FOP-009-01-05
1
TAS-101
11/8/10
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. 3M Foam Roof Tile Adhesive RTA-1 can be used with flat, low, medium and high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of 3M Foam Roof Tile Adhesive RTA-1 roof tile
adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein.
F �
—W
2 ,
F'=
MS
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code,
I
NOA No.: 15-1201.04
Expiration Date: 01/03/21
Approval Date: 12/31/15
Page 3 of 8
INSTALLATION:
1. 3M Foam Roof Tile Adhesive RTA-1 may be used with any roof tile assembly having a current NOA that
lists attachment resistance values with the use of 3M Foam Roof Tile Adhesive RTA-1.
2. 3M Foam Roof Tile Adhesive RTA-1 shall be applied in compliance with the Component Application
section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive
attachment with the use of 3M Foam Roof Tile Adhesive RTA-1 shall provide sufficient attachment
resistance to meet or exceed the resistance values determined in compliance with Roofing Application
Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA.
3. 3M Foam Roof Tile Adhesive RTA-1 roof tile adhesive and its components shall be installed in accordance
with Roofing Application Standard RAS 120, and Fomo Products, Inc. 3M Foam Roof Tile Adhesive RTA-
1 Operating Instruction and Maintenance Booklet
4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by Polyfoam
Products, Inc.
5. Tiles must be adhered in freshly applied adhesive. Tile must be set within 4 minutes after 3M Foam Roof
Tile Adhesive RTA-1 has been dispensed. 1
6. 3M Foam Roof Tile Adhesive RTA-1 placement shall be in accordance with the 'Placement Details' herein.
Each generic tile profile requires the specific placement noted herein.
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile
Profile
Typical Placement
! Detail
Weight per paddy (grams)
"NLow & High Profile
#
12
fligh Profile 2-Piece Barrel
# 2
12
LABELING: i
All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami -
Dade County Product Control Seal as shown below. i
MIAMI•DADE COUNTY
I
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
NOA No.: 15-1201.04
MIAMI•DADE COUNTY Expiration Date: 01/03/21
Approval Date: 12/31/15
Page 4 of 8
i
ADHESIVE PLACEMENT DETAILS
PLACEMENT DETAIL ## 1
-c.• •
FLAT PROFILE
NOA No.:15-1201.04
Mwr�n•nEwe couNnr Expiration Date: 01/03/21
Approval Date: 12/31/15
Page 5 of 8
ADHESIVE PLACEMENT DETAILS
PLACEMENT DETAIL ## 1
-c.• •
FLAT PROFILE
NOA No.:15-1201.04
Mwr�n•nEwe couNnr Expiration Date: 01/03/21
Approval Date: 12/31/15
Page 5 of 8