HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFINGFlorida Building Code Online r�
BCIS Home Log In User Registration Hot Topics 6,
ss
ProductApproval
USER: Public User
P-Juct Approval Ptbm > Rrcduct ar Apphcanon Sgardi > A_po
FL t
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/PhonelEmail
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who dei
the Evaluation Report,
Florida License
Quality Assurance Entity
Quality Asswance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
i
Equivalence of Product Standards �
Certified By
i
Sections from the CUde
I�
Page 1 of 4
ANNED
Surcharge Stats & Fads
Publications FaC Staff SCIS Site Mapy
Links Search
_Lis, : Application Detail
FL17022-R7
Revision
2017
Approved
08/18/2017v. date reapply 08,21117
Extreme Metal Fabricators, LLC
2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
f1validation@yaboo.com
Richard McKuhen
fivalldation@ yah oo.com
Richard McKuhen
2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
richard,15emfab.net
Roofing
Metal Roofing
RECENED
MAR 1 5- Zolo
Permitting Department
St. Lucie County
FILE COPY
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
. Evaluation Report - Hardcopy Received
LOCKE BOWDEld
PE-49704
Keystone Certifications, Inc.
04/22/2024
Zachary R. Priest, P.E.
W Validation Checklist - Hardcopy Received
F1170Z R7 COI_FL_j.70?2.i_ 5 V CRIhh�SCDdf
Standard Year
TAS L25 2003
UL 1897 2012
UL 580 2006
http://iv,,vw.floi-idabuiidlna.org/pr/pi- app dil.aspx?parai-n==-,.vGEVXQw-tDqv2aBQpHpQQ... 1 / 10/2018
Florida Building Code Online
Page ? of 4
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
of
FL * - I Model, Number or
Method 1 Dption D
08/1812017
08/25/2017
08/28/2017
10/1012017
Description
Limits of Use Installation Instructions
Approved for use in HVHZ: No F..L.17022 R7 II FL 17022.3 5V CRIh1P ss_r,pdf
Approved for use outside FIVHZ: Yes Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: +NIA/- fable A Evaluation Reports
Other: Refer to evaluation report for conditions. Istall the FL17022_R7 AE_FL 17022.1 5 V CRIMP ssrpdf
assembly in compliance with the installation meth d listed in Created by independent Third Party: Yes
this report and applicable code sections of FBC. R fer to
manufacturer's installation instructions.
17022.2 2 - "5V Crimp" (116) 0,032" Aluminum, 3/8" Rib height, 21" wide lapped roof
panel, mechanically attached to 15/32" plywood or blrood
Deck :•ritli exposed fasteners
Limits of Use I Installation Instructions
Approved for use in HVHZ: Flo FL17022 R7 1I.FL_M�22.2 V C 5 RII�iP 0.0_HLU 2 i1__ssr,{�df
Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704
Impact resistant: NO Created by Independent Third Party: Yes
Design Pressure: +N/AJ-Table A i Evaluation Reports
other: Refer to evaluation report for conditions. stall the 1 F1.17022-_R1_A_E Fl_ 1702 ,_5 V CRIMP 0 032
assembly in compliance with the installation meth d listed in is A_LUD7 ssr_.piif
this report and applicable code sections of FBC. R.fer to I Created by independent Third Party: Yes
manufacturer's installation instructions.
17022.3 13 - "1.5" Plechanicat Sea " (R5) 1.5" rib height, 16" wide, 24 gauge steel, standing seam
roof panel mechanically attarhed to 15132" plywood or wood
j deck with clips and fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL1.7022__R7 I_LF(L1702 _3__7 _S fi�CHAfViCAL
Approved for use outside HVHZ: Yes seam-2 4ciRssr.pdf
Impact Resistant: No Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/-TableA Cleated by IndependentThird Party: Yes
Other: Refer to evaluation report for conditions nd Evaluation Reports
limitations of use. Install the assembly in cornplialrice with FL1702,2_R7_gE, FL 1?022.3 1.5 [MECHANICAL
the installation method listed In this report and applicable seam7.q .2 a_s Al!i_f
code sections.of FBC. Refer to manufacturzr's installation Created by Independent Third Party: Yes
instructions.
17022.4 i 4 - %-5" Mechanical Sa m" (PS) ' 1.5" rib height, 16" wide, 0.032" aluminum, standing seam
i roof panel mechanically attached to 15(32" plywood or Wood
j Deck with clips and fasteners.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: N/A/ -Table A
Other: Refer to evaluation report for corditionslarid
limitations of use. Install the assembly in compliance with
the installation method listed In this report and applicable
code sections of FBC. Refer to manufacturer's installation
Instructions.
I Installation Instructions
i FL17022_R7 II_FL.17o22.4 MECHANCIAL_SEAM,
Ii\l.U_P1)flUtl ssspdf
f Verified By: Locke Bowden, P,E. 49704
f Created by independent Third Party: Yes
{ Evaluation Reports
Ii FL17Q22_til ltF_F1,17(�7,7.4 h117CHAPICIAL SEAM
ALl1flIfdUP1 ssf.,pdf
Created by Independent Third Party: Yes
17022.5 5 - "1 in. Plait Strip" (115) 1" rib height, 16" wide, 26 gauge steel, standing seam roof
1 panel mechanically attached to 15132" plywood or wood
deck with fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17LSTRIP ssr.ecff
Approved for use outside HVHZ: Yes I Vcnfled By: Locke Bowden, P.E_ 49704
Impact Resistant: Flo I Created by Independent Third Party: Yes
Design Pressure: a PI/Al-Table A Evaluation Reports
Other: Refer to evaluation report for conditions and FL 170127✓I—L-DJAI LSTRIP ssv.pdf
limitations of use. Install the assembly in compliance with I Created by Independent Third Party: Yes
littp://-vvw~w.tloridabuilding.org/pr;pi app_dtl.aspk9parana=i�rGENrk'Qi,v-tDgv2aBQl)HpQQ... IJ/IO?018
Florida.Building Code Online
Page 3 of 'l
:.the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturers installation
instructions,
17022.6 to - "1 in. Rail Sti p" (RS)I
1" lilt height, 1.6" wide, 0.032" aluminum, standing seam
# roof panel mechanically attached to attached to 15/32"
Limits of Use
plywood of, Rood Deck with fasteners,
Installation instructions
Approved for use in HVHZ: No
FL17022_R7 ILFL._17Q?2.6 1.0 NAIL STRIP 0.032
Approved for use outside HVHZ: Yes
iatur�t^ssL•l2df
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +NJA/-Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions
nd
Evaluation Reports
limitations of use. Install the assembly in complia
tce with
FL].7022 R7 AE F_L_7,7Q2_2 6 i.0 MAIL STRIP U.032
the installation method listed in this report and agpiicabie
ALUkj ssssi-Ldf
code sections of FBC. Refer to manufacturer's his
ablation
Created by Independent Third Party: Yes
I
instructions.
,—
r I
17022.7 7 - "1.5 in. Nall Strip" ( 5) 1.5" rib height, 19" wide, 26 gauge steel, standing seam
iroof panel mechanically attached to 15!32" plywood or wood
deck with fasteners.
Limits of Use qiq Installation Instructions
Approved for use in HVHZ: No I FL17t722 R7 II FL 17022.7 A;! Mai! Stri�26GA ssr,�df
Approved for use outside HVHZ: Yes ' Verified By: Locke Bowden, P.E. 49704
Impact Resistant: Wo 1 Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A f Evaluation Reports
Other: Refertoevaluation report for conditions and 1( FLI707?_R7 AE_ FL 17022.7 1_5 Mail Strif�2tiGF� ssr. df
hrnitations of use. Install the assembly in complF nce with i Created IndependenC Third Party: Yes
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturers installation
instructions.
17022.8 I s - "EMAY. Rib" (RS)
_l{
l
(29 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners. µ
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
EL170Z 7�I 022E1AXRib pdfF178 r
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent third Party: Yes
Design Pressure: +N/A/ Table A
Evaluation Reports
Other: Refer to evaluation report for conditions)
and
&;t7022_R7TAE FL 177�2? �_F.f iAX, Rib ssr.,pdf
limitations of use. Install the assembly in compliance
with
Created by Independent Third Party: Yes
the Installation method listed in this report and applicable
code sections of FBC. Refer to manufacturers installation
instructions.
170229 9� PBR TIAX" (R5) 1 -16 gauge steel, lapped roof panel mechanically attached to
1 1 15/32" plywood or wood deck with exposed fasteners.
Limits of Use T i Installation Instructions
Approved for use in HVHZ: No ! FL17Q23 R7�II FL170ZZ.9 PEiR RIB_ ssr.odf
Approved -for use outside HVHZ: Yes i Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No j Created by independent Third Party: Yes
Design Pressure: +N/A/ -Table A ; Evaluation Reports
Other: Refer -to evaluation report for conditions and F17022 R7 AF F( i70z2.9 P17F.wRSS sei_odf
limitations of use. Install the assembly in compliance with Created by Independent Third Party: Yes
the installation method listed in this report and *licahte
code sections of FBC. Refer to manufacturer's installation
Instructions.tru Insctions.
;eacki 'rv_41
Cc^tart tts :: 2AOI ?lair Stone no T_.:,)ahassn- n_ 3Z399 Phone: 850.41`17-1824
1
The State of Florida 15 an P.A(EEO employer. Co!)vr*ht '+007-2ed; 51,m r f Flnrlya.:: Prioa_v Statement :n AccG5ibd!r' Statement :: AeF.rna StatemenC
Under Florida law, email addresses are public records. If you do not want your a -mail addt s released in response to a Pub;ic-records request, Co not sand
electronic mail to this entity. Instead, contact the offce by !lhcne or by trad¢lona! mail. I£ you have any queszians, please contact 850.467.1395. "Pursuant to
Sedan 455.275(1), Flo, Wa Statutes, effective October 1, 2012, licensc-asiicansed under Chapter 455, FS. must provide the Department with an email addr,--s If
then hnve one. The emaiis provided may be used for official 4ommur.icaticn with the lkensee. Ffwmver mail addresses are public record. TF •rcu do not va!sh to
supply a personal address; pleae provide the Department enTh an email address ahL-h can be node avallable to the public. To determine if you area licensee under
Chapter 455, FS., please click hue .
Product Approval Accepts,
http:11-wkw.floridabuiIdin-.org/prlpr_app_ dtl_aspx?parim=tivGE XQvc,-tDgv?aBQpB.pQQ... 1/!0/2018
Compliant with Florida Building Cade 2017 (6'r ed.)
Cornpliar!t %mith Florida Product Approval Rul' # 61G20-3
Compliant: Keystone Certifications
Product: V vri;a�p 26GA Steel Rood pane! FBSec.1S07.4.2
Field strength: SO ksi amain.; Attached to min.15/32"" plywood or Wood
Deck w/ min. 0.42 specific gravity wi h screws. 24"° Coverage
Rib Height 3/81"
Corrosion Resistant Compliant: FBC Sec. 1 507.4.3
Fastener 1(Method 1 Attachment)* #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate
3/16" min. three deck or S/r embedmentint good plank. (*or sufficient length to meet
requires -ents)
Fastener 2:(Method 2,3, cis 4 Attachment):
penetrate 3/16" mina Baru deck or 5/88" en
tv meet require;nents).
Underlaymente To be compliant with FBC
Slope. Shall be in compliance with FBC Sec.
3 x 1-1/2" Hex -Washer Head wood scree* to
dment into mood plank. (*or sufficient length
Chart 2507.1.1
Fastener attachment specifications above
Irstall Details: Table A Allowable Loads
IME'6"OD _ 1:l 0
POETHOD
:'OETt Ot2
DESIGN PRESSURES
( -� PSF � -'� .� �
Ala', t9.C.
-�0_L_PSF
� -228 PSF
ROW SPACING
8" O.C.
f 6" o.r.
FASTENER SPACING (ALONG Pavel width')
iz"i O.C. � �
�-
12" O.C.
�2" R.C.
FASTENER SIZE
9 _ 1 M�
#10
1 #10 1
Reference Data: ARCHITEcrURAL TESTING;r INC. TST ID#:1527����
UL 580-06 & 1897-041 'hest Report OBB93.01-450-18 05/02/14
'Fes{ Report i F3366.01-450-€8 12/18/15
TAS 125-03 Test Report D05893.02-450-18 07/2.2/14
�rEgU R/ALLXCY UL 1897-00, is equivalent to test standard UL 1897-212 `,-Design pressmi-e margin of safety E: Q
Locke Bowden, P.E. does not have, not will acquire a financial
under this evaluation.
Locke Bowden, P.E. is not owned, operated, or controlled by
report.
Jrr
in t a ura ray factoring or distributing products
amy cowiparlVormbild i:ureol, or distributing products under this
' . A;
FL1 a 022.@ 6V Crimp t26GA Stelle[), 24" WideRoof Panel - Details
Limitations:
4- Umderldymentto be compliance with current Florida Building
. Minimum slope to be compliant with Florida Building Code 2(
Products are compliant for State of Florida product approval
4. Engineering analysis for "project specific approval by local at
5. Fire classification is not part of this acceptance. Shear diaphi
S. Support framing in compliance w/FBC 2017 61h, ed., Chapter
Structural Loading.
7. This report does not imply warranty, installation, recommend
ode (FBC)2017 61h ed.
7 61h ed., and per with Manufacturer's installation reference.
�r Rule 61 G20-3. Compliance Method: 1-D
iorities w/jurisdiction is allowed by other registered engineers.
Jm values are outside this report.
for Steel, Chapter 23 for Wood and Chapter 16 for
product use outside of this report.
-
`i
DA'nor
x1U�1•it" in ,errble.WforRow ---- 5-\+CrimpP.00lPanel
r Spscfng nCDes;gnPressures
Hex WasherlFlead Wood Screwy /
r
//.
4VI
r I
15132" or gr atur PPjrtcad, cr
V.bw plank
3f8"
1
, _.-._-
Profile
Nominall2" I _� Nominall2"
o.c- �� o.c.
------------- -..- ...._-� _ -.__
Fasten
f9 X 1-1/2" Min. or #E10 x 1-1/2" Min. per
Table "A" Hex Wtifasher lead Screrr:<
(Spaced 12" o. c. across the Panel Wdth
Panel f •� Rererto Table"A"'for Spacing Along Panel
Overlap Length
Deck- 15/32' orgreater
j Plykiyood, or
1 - Znbo� plank