HomeMy WebLinkAboutAPPROVED PRODUCTS- FBC APPROVED PRODUCTS:
APPROVAL MAXIMUM
PRODUCT CATEGORY SUB CATEGORY MANUFACTURER ALLOWABLE
No. & ®ATE
WIND SPEED
STRUCTURAL COMPONENTS
ROOF DECK
CAROLINA CARPORTS, INC.
FL6596.1-R5
190
26 Gauge AG Panel
10/10/17
STRUCTURAL COMPONENTS
STRUCTURAL WALL
CAROLINA CARPORTS, INC.
FL6702.1-R5
180
26 Gauge AG Panel
10/10/17
STRUCTURAL COMPONENTS
FLOOD VENT
FLOOD FLAPS, LLC
FLW381.1-R2
NA
8x16 Flood Flap
16/03/11
EXTERIOR DOORS
SWINGING
ELIXIR DOOR AND METAL COMPANY
FL17996.3
139
Series 402-14
09/07/15
EXTERIOR DOORS
SWINGING
ELIXIR DOOR AND METAL COMPANY
FL17996.5
170
Series 407
09/07/15
EXTERIOR DOORS
ROLL -UP
ASTA INDUSTRIES INC.
FL6888.1-R5
180
Model 203
10/06/17
WINDOWS
SINGLE HUNG
POCAHONTAS ALUMINUM COMPANY, INC.
FL12940.2-R4
139
Model 100 VS
01/07/16
WINDOWS
SINGLE HUNG
MI WINDOWS AND DOORS
FL17499.3-R2
180
Model 185 SH
12129)
TABLE 1
RAFTER FRAME, END POST, GROUND ANCHOR AND PANEL FASTENED SPACING SPECIFICATIONS
AVERAGE FASTENER SPACING
ON -CENTERS ALONG RAFTERS OR
MAXIMUM
PURLINS, AND POSTS OR GIRTS
WIND
ULTIMATE
NOMINAL
POST / RAFTER
(INCHES)
INTERIOR
END
RISK
EXPOSURE
WIND SPEED
WIND SPEED
SPACING
CATEGORY
CATEGORY
(MPH)
(MPH)
(FEET)
POSTS/RAFTERS
POSTS/RAFTERS
1 1'r1 Til 1 rn_
_S2A-Tn=4-� GT
s' .
I I C
METAL CARPORT INSTALLATION PLANS AND DETAILS
AND
FRAMING AND FASTENER SPECIFICATIONS
'. S FASTENERS OR ATTACHMFI(
Q RESPONSIBILITY OF THE FOR CONSTRUCTION IN THE
cl'1 4 6 STATE OF FLORIDA
CONTRACTOR OF RECORD PREPARED FOR:
CAROLINA CARPORTS, INC.
P.O. BOX 1263
DOBSON, NORTH CAROLINA 27017
151 TO 180 1.117 TO 139 1 4.0 -6 6
NOTES: 1. Specifications applicable to 26 gauge metal roof and wall panels fastened directly to 12 or 14 gauge steel tube framing, or 18 gauge hat DETAIL$ •1 C AND 1 D SHOWN QN SHEET 4 OF 5:
channel roof purlins.
2. Specifications applicable only for mean roof height of 20 feet or less, and roof slopes of 7" to 27" (1.5:12 to 6:12 pitch). Spacing
requirements for other roof heights and/or slopes may vary.
GENERAL NOTES:
1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING,'AND BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING,
ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS; OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS.
2. THESE STRUCTURES ARE DESIGNED AS NON -HABITABLE UTILITY/STORAGE BUILDINGS (RISK CATEGORY 1) CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT
SPECIFICALLY ADDRESSED HEREIN WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE, AND INSTALLATION OF DOORS, WINDOWS OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS LIST ON THIS SHEET, AND NOT
PROVIDED AND INSTALLED BY CAROLINA CARPORTS, INC. SHALL BE AT THE OWNER'S RISK. BECHTOL ENGINEERING AND TESTING, INC.; SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF
ADDITIONAL LOADS OF NON -APPROVED COMPONENTS.
3. ALL STEEL TUBING SHALL BE 50 KSI GALVANIZED STEEL. ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL.
4. FASTEN METAL ROOF AND WALL PANELS TO FRAMING WITH #12-14 x 3/4" SELF DRILLING FASTENERS WITH CONTROL SEAL WASHER @ 6" O.C. AVERAGE.
5. ALL FIELD FRAMING CONNECTIONS SHALL BE #12-14 x 3/4" SELF DRILLING SCREWS WITHOUT CONTROL SEAL WASHER. ALL SHOP FRAMING CONNECTIONS SHALL BE WELDED.
6. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS. THE REINFORCING STEEL SHALL BE MINIMUM GRADE 40. CONCRETE SLAB FOUNDATIONS SHALL BE REINFORCED WITH 6X6-W1 .4XW1 .4 WELDED WIRE
FABRIC COMPLYING WITH ASTM A 185, OR WITH SYNTHETIC FIBER REINFORCEMENT COMPLYING WITH ASTM C1116.
7• BASE RAIL GROUND ANCHOR REQUIREMENTS: ONE WITHIN 6" OF EVERY POST LOCATION, AND BOTH SIDES OF OPENINGS WHERE BASE RAIL IS ABSENT. GROUND ANCHORS ARE NOT REQUIRED FOR CONCRETE FOOTING AND/OR
CONCRETE SLAB CONSTRUCTION, EXCEPT AS SHOWN ON DETAIL 1 E, SHEET 4 OF 5; WHERE BASE RAIL IS FLUSH WITH EDGE OF SLAB. SEE GROUND ANCHOR SCHEDULE (THIS SHEET) FOR SPECIFIC TYPE GROUND ANCHOR REQUIREMENTS.
8. CONCRETE EXPANSION ANCHORS SHALL BE WEJ-IT ANKR-TITE MODEL AT1252, OR SLEEVE ANCHOR MODEL HSA 1260, OR EQUIVALENT.
9• POST/RAFTER BRACING: BRACE ON EVERY POST/RAFTER CONNECTION, EXCEPT FOR END WALLS AND GABLE ENDS.
10. SLAB FOUNDATION SUBGRADE SOILS SHALL BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDER PER SECTION R318.1 OF THE FLORIDA BUILDING CODE SIXTH EDITION (2017) (FBC FE 2017) - RESIDENTIAL, AND SECTION 1816.1
OF THE FBC FE 2017 - BUILDING.
11. 14 GA FRAMING IS 2-1/2" x 2-1/2" TUBE STEEL (TS). NIPPLES ARE 2-1/4" x 2-1/4" 12 GA TS FOR 14 GA FRAMING. 12 GA FRAMING IS 2-1/4" x 2-1/4" TS. NIPPLES ARE 2" x 2" 12 GA TS FOR 12 GA FRAMING.
GROUND ANCHOR SCHEDULE
ULTIMATE WIND SPEED
1 10...120 1.30: 140 ' 150 160 170 ' 180
12.
14
30" An
16
Detail 1 D
18
❑
20
48''
Anchor
.
0
22'
Detail1C
0
24
-
26
60TAnchori
m
28
30
Detail 1C
PREPARED BY.•
BECHTOL ENGINEERING AND TESTING, INC.
605 WEST NEW YORK AVENUE
DELAND, FLORIDA 32720
Certificate of Authorization No. 00005492
( F3C �L co
Clv rOUNTY RITI,0 TSION
E D FOR COMP
:: �r LU BY
L, z
.kN D PERN-IIT � T BE KEPT ON JOB
1`SFECTIOV W L BE �IA)E,
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH A" APPWCAOLI LADES.
r 1 4 I
.l • � t .� I
THIS IS TO CERTIFY THAT THE CALCULATIONS AND
SPECIFICATIONS HEREIN HAVE BEEN PREPARED BY THE
UNDERSIGNED PROFESSIONAL ENGINEER, AND ARE IN
ACCORDANCE WITH THE REQUIREMENTS,OF SECTION 1609 OF
THE FLORIDA BUILDING CODE, SIXTH EDITION (2017). THE PLANS
ARE VALID UNTIL THE NEXT REVISION OF THE FLORIDA BUILDING
CODE.
BECHTOL E N T 9yNG, INC.
605 WEST NEW,4YOA E• • • �` /
DEIAND, FL D 20
CertlBcate 0 i
i
. y '
N�f T
Thomas LU _
Florida 38538
i � • �'fA'�E O � �
0, FLO
V �
CAROLINA CARPORTS, INC.
GENERIC PLANS FOR USE IN THE STATE OF FLORIDA
AM
,0V8ECHT0LEN61NEERfNG MKB NTSy V
AND IIP=NQ, I'm
catsinma ¢orawNru. DWACHWtMu. AND IIAt6 MM nsnNo WaAms a RR 918001
"1^.101'E°` TB SHEET 1. OF 5
is
1
x2"x2" 16 GA ANGLE CLIP
SECURE TO POST AND
RAFTER WITH (4) #12-14 x 3/4"
SDF's, (2) ON BOTTOM,
(2) ON SIDE
OR.
2°x4" 16 GA PLATE
SECURE TO EACH SIDE OF
TS END POST POST/RAFTER CONNECTION
WITH (4) #12-14 x 3/4" SDF's,
(2) ON POST, (2) ON RAFTER
END POST/RAFTER CONN. DETAIL
Not To Scale
1-1/7 x 1-1/2' x 2" 16 GA
CLIP ANGLE SECURE TO
RAFTER POST AND GABLE
RAIL WITH (4),#12-14 x 3/4' SDFs
(2) ON TOP, (2) ON SIDE
TS RAFTER POST
1-1/2. x 1-1/2' x: 2" 16 GA CLIP
ANGLE SECURE TO RAFTER
AND GABLE RAIL WITH (4)
#12714 x 3/4" SDFs, (2) ON TOP,
(2) ON BOTTOM
GABLE RAIL
GABLE. RAIL'.TO RAFTER POST
CONNECTION DETAIL
h Not To Scale
#12-14 x 3/4" SDF
@ 12" O.C.
3'A.
ROLL -UP DOOR GUIDE TO POST
CONNECTION .DETAIL
Not To Scale CURTAIN: 26 GA. galvanized steel with
baked on epoxy primer & polyester top coat
NIPPLE
DBL. HE
S NIPPLE
ACH WITH
K 3/4"
.LING FASTENERS
POST
Ct RAFTER POST/DBL. HEADER DETAIL
Not To Scale
1=1/2° x 1-1/2" x 2" 16 GA CLIP ANGLE
SECURE TO RAFTER POST AND .
GABLE RAIL WITH (4) 012-14 x 3/4'Si
TOP, AND BOTTOM
1-1/2° x 1-1/2". x 2' 16 GA CLIP ANGLE
SECURE TO RAFTER AND GABLE
RAIL WITH (4) #12-14 x 3/4' SDF's,
(2) ON TOP, (P) ON BOTTOM
RAFTER POST
LONG TS NIPPLE
1/8' SECURE WITH (4) #12-14 x 3/4"
r� SELF -DRILLING FASTENERS
LE TS HEADER
NIPPLE TO
DBL. HDR.
RAFTER_ POSTMEADER ,DETAIL
Not To Scale
3/16"
12" LONG TS NIPPLE.
SECURE POST TO NIPPLE
WITH (4) #12-14 x 3/4' SDFs,
6' LONG TS NIPPLE.
SECURE WITH (4) #12-14 x 3/4" SDF's
24" 16 GA U-CHANNEL BRACE'(5' TO T POST)
6" LONG TS NIPPLE 48' 16 GA U-CHANNEL.BRACE (8' TO IV POST)
SECURE RAFTER AND POST TS GABLE RAIL BRACE ANGLE SHALL BE MIN. 45°
TO NIPPLE WITH (4).#12-14x 3/4" TO MAX. 60° FROM HORIZONTAL'
SELF -DRILLING- FASTENERS TS RAFTER POST
TS RAFTER POST
SIDE, EXTENSION
GABLE RAIL TO.. RAFTER
POST-RAFTER/POST DETAIL
� 1.:CONNECTION DETAIL . 1�2J Not To Scale
.Jio
--r7 TS POST
II LI.
.TS NONSTRUCTURAL.
HEADER
fir•---=-------=--- I I
II I
II I
II I
I
SWINGING DOOR
(Size varies, see plan)
POST O
OSECTION
Not To Scale
#12-14 x 3/4' SDF
@ 12" O.C.
' e-
6' LONG TS NIPPLE
SECURE EACH WITH (4) #12-14 x 3/4'
SELF -DRILLING FASTENERS
- ITS POST
TS BASE RAIL
3/16' NIPPLE TO
BASE RAIL
RAFTER POST/BASE .
� BASE RAIL CONNECTION. DETAIL
Not To Scale
TS RAFTER POST
-2"x4" 16 GA PLATE (ONE REQUIRED)
SECURE TO EITHER SIDE OF
POST/RAFTER CONNECTION
WITH (4) #12-14 x 3/4" SDF's;
(2) ON POST, (2) ON RAFTER
ITS LEAN-TO RAFTER
�2°x2'x2° 16 GA ANGLE CLIP
SECURE TO POST AND
RAFTER WITH (4). #12-14 x 314"
SDFs, (2) ON RAFTER,
(2) ON POST
POST / LEAN-TO RAFTER CONN.,DETAIL.
13 Not To scale . .
BECHTOLENZ31ItINQI, oo;II�
605 WEST Ni VENUE
DELAND, FLORIDA 3272b •.
Certrecat6&A eon o-- 3853
Thomas 6 STATE
Florida License OF
CAROLINA CARPORTSs INC.
GENERIC PLANS FOR USE IN THE STATE OF FLORIDA
01/02/18
®ECHTOL. ENG/NEER(NG ° "*x MKB- � , NTS
AND 7115877M4 Ina
RR G18001
CM=TNQ WDTM rJa. 0MR01A . *0 MATS M*4 Marrs"
xraW �'N°"
TB . SHEET 5 OF 5'