HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTSProduct Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report I
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
I
Referenced Standard and Year (ofiStandard)
I
I
i
:ode Onlir�
As & Facts I Publications I FBC Staff I BCIS Site Map I Links I Search
n Detaif �i / �" 6 03 � -V5—?
v��2uzT��A L
ST. LUCIE COUNTY BUILDING DIVISION
REVIEWED FOR C p q
REVIEWED BY
DATE
PLANS AND PERMIT MUST BE KEPT ON JOB
SITE OR NO IN$PECTION(S) WILL BE MADE
Tri-Built Materials Group, LLC
PO Box 70
Rutherford, NJ 6114ESE PLANS AND
(800) 516-1485ARE S BJECT TO ANY CORRECTIONPROPOSED
david.ruiz@triby rWD BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
davild.rulz@tribuiltmmMPmY WITH AU-�PUCABLE CODES.
David Ruiz
,
ORoute 17 North
Rutherford, NJ 07073
CONCEALEDFASTENERS OR ATTACHMENTS
HMENTSEast
ARTRES RESPONSIBILITYOF
(201) 842-2449
THE
CONTRACTOR ORRECORDdavid.ruiz@tribuiltmaterialsgroup.com
ALL MANUFACTURES LABLES SHOWING
U FACTORS AND SHGC COMPLIANCE
WITH FBC ENERGY CODE MUST
REMAIN ON ALL DOORS AND WINDOWS
ALMerigyr,fe6ts
UNTIL INSPECTIONS ARE APPROVED
Evaluation Report from a Florida
Registered Architect or a Licensed Florida
Professional Engineer
1 . Evaluation Report - Hardcopy Received
Robert Nieminen
PE-59166
UL LLC
07/18/2020
John W. Knezevich, PE
,o� Validation Checklist - Hardcopy Received
FL16048 R6 COI 2017 01 COI Nieminen.Ddf
Standard
Year
ASTM D1970
2015
ASTM G155
2005
FM 4474
2011
FRSA/TRI April 2012 (04-12)
2012
UL1897
2012
Equivalence of Product Standards FILE COPY
Certified By
i
i
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?par im=wGEVXQwtDgtFPmdYNDWrwipmtAnR8jv9FiYHTk4FLCxcgVtRhfvMw%3d%3d 1/2
3/15/2018 l '
Sections from the C"___
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
i
Florida Building Code Onli�
1
Method 1 Option D
I
09/25/2017
10/01/2017
10/03/2017
12/12/2017
FL #
Model, Number or Name
Description
16048.1
f RI BUILT}�Rootif nderlagrnents
Self a� in'g, m flied bit�u n roof y�mentss?D `
Limits of Use I
_. . __,_ ,
Installation Instructions
Approved for use in HVHZ: No
FL16048 R6 II 2017 09 FINAL ER TRI-
Approved for use outside HVHZ: Yes
BUILT UNDERLAYMENTS FL16048-116.pdf
Impact Resistant: N/A I
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-150
Created by Independent Third Party: Yes
Other: 1.) The design pressure noted herein pertains to use
Evaluation Reports
of foam -on tile systems overtop the self -adhering
FL16048 R6 AE 2017 09 FINAL ER TRI-
underlayment for one particular application. See ER Section
BUILT UNDERLAYMENTS FL16048-R6,pdf
5.6.4 for details. 2.) Refer to ER Section 5 for other Limits of
Created by Independent Third Party: Yes
Use. I
I
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Co1J 1 ht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
i
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
® ®® -
Credit Card
Safe
R8jv9FiYHTk4FLCxcgVtRhfvMw%3d%3d 2/2
QOTRINITYIERD
EVALUATION REPORT
TRI-BUILT Materials Group, LLC
PO Box 70
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
(203) 262-9245
Rutherford, NJ 07070 I D6te of'Issuance l0%25/.2201�2
(800) 516-1485 R 4sion'6. 09/25/2Qt7
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
dESCRIaTioN 1111-BUILT4Roof'Underlaymentsr
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitultes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documelntation changes. Trinity) ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity) ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluatioi Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCAANE1983
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to i
distributing products it evaluates.
2. Trinity I ERD is not owned, operated or controlled by
3. Robert Nieminen, P.E. does not have nor will acquit
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acqui
product.
S. This is a building code evaluation. Neither Trinity
project on which this Evaluation Report, or previoul
specifically for that purpose.
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. an 09/25/2017. This does not serve as an electronically signed
document.
or will it acquire, a financial interest in any company manufacturing or
y company manufacturing or distributing products it evaluates.
a financial interest in any company manufacturing or distributing products for
a financial interest in any other entity involved in the approval process of the
RD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
versions thereof, is/was used for permitting or design guidance unless retained
Uf-RINITY I ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT Materials Group, LLC, have
demonstrated compliance with the following sections of the 6' Edition (2017) Florida Building Code through testing
in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations /
Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Resistance
I
FM 4474
2011
1504.3.1
Wind Uplift i
UL 1897
2012
1504.6
Accelerated Weathering
ASTM G155
2005
1507.2.4 / 1507.1.1, 1507.2.9.2
Physical Properties
ASTM D1970
2015
1507.3.3
Physical PropertieIs
FRSA/TRI April 2012 (04-12)
2012
3. REFERENCES:
I
Entity
Examination i
Reference
Date
ERD (TST6049)
Physical Properties
S40540.02.13-1
02/19/2013
ERD (TST6049)
Physical Properties
S40540.11.13
11/19/2013
ERD (TST6049)
Physical Properties
S40540.03.14
03/26/2014
ERD (TST6049)
Physical Properties
S44870.04.14-2
04/02/2014
ERD (TST6049)
Physical Properties
S44870.04.14-3
04/02/2014
ERD (TST6049)
Physical Properties
S44870.04.14-1
04/10/2014
ERD (TST6049)
Physical Properties
S44870.04.14-4
04/10/2014
ERD (TST6049)
Physical Properties
S43530.02.14-1-R1
05/14/2014
ERD (TST6049)
Physical Properties
S43530.05.14
05/28/2014
ERD (TST6049)
Physical Properties
S40540.10.14
10/31/2014
ERD (TST6049)
Physical Properties
SC7645.02.15
02/13/2015
ERD (TST6049)
Accelerated Weathering
SC8520.04.15
05/27/2015
ERD (TST6049)
Wind Resistance
SC14045.05.17-Ri
06/07/2017
UL, LLC. (QUA9625)
Quality Control
Multiple -Listing R16814
12/10/2015
UL, LLC. (QUA9625)
Quality Control
Service Confirmation
Exp. 07/18/2020
4. PRODUCT DESCRIPTION:
4.1 Tri-Built Sand-R SA Shingle Underlayment is a self -adhering, glass -mat reinforced,
sand -surfaced, SBS
modified bitumen
roof underlaymentl with a 36-inch sheet width; meets ASTM D1970.
4.2 �k3grTrl� Built S/AHT TAU .11nderlaymert a self -adhering, non -woven polyester fabric surfaced, SBS modified
bitumen roof underlayment; meets ASTM D1970 and
FRSA/TRI April 2012.
4.3 Tri-Built Smooth
HT S/A Underlayment is a self
-adhering, glass -mat reinforced,
film -surfaced, SBS
modified bitumen
roof underlayment; meets ASTM
D1970.
S. LIMITATIONS:
5.1 This is a building code evaluation.I Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design, U.C. Evaluation Report A42960.10.12-R6
Certificate ojAuthorization #9503 6T" EDITIONI(2017) FBC NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017
1 Page 2 of 6
1 I •
TRINITY ERD
5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made to the
Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the
prepared roof covering.
5.5 Allowable Roof Covers:
TABLE 1: JROOF COVER OPTIONS
Underlayment
Asphalt
I
Nail -On Tile
Foam -On Tile
%'
Metal
Wood Shakes
D
Slate
Shingles
i
& Shingles
Tri-Built Sand-R SA Shingle
Yes
Nol
No
No
Yes
Yes
Underlayment
ULBuilt 5/A HT T,14
Yes
£
Yes
nderiayment
Yes
Yes
See 5.5.1
Yes
Yes
Tri-Built Smooth HT S/A
yes
No
No
Yes
Yes
Yes
Underlayment
5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations.
TABLE 1A: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS)
Adhesive
Florida ProductlApproval
Underlayments
ICP Adhesives Polyset® AH-160
FL6332
Tri-Built S/A HT TU Underlayment
Dow TileBondTI
1`1_22525
Tri-Built S/A HT TU Underlayment
I
5.6 Allowable Substrates: i
I
5.6.1 Direct -Bond to Deck:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
l
➢ Plywood; ASTM D41 primed Plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41
primed Southern Yellow Pine; ASM D41 primed structural concrete.
While not required over plywood, OSB or Southern Yellow Pine substrates, TRI-BUILT Materials Group, LLC
recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note:
TRI-BUILT Materials Group, LLC requuires tongue -and -groove board decking be covered with plywood or
OSB prior to installation of the self-ai hering underlayment.
5.6.2 Bond -to -Insulation:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam -on tile systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be
designed by a qualified design pro lfessional and installed based on testing of the insulation/underlayment
system in accordance with FM 4474, Appendix D or TAS 114, Appendix J.
I
' Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design, U.C. I Evaluation Report A42960.10.12-R6
Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-116
TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017
Page 3 of 6
i
I
l
I
I
I
•
j TRINITY I ERD
5.6.3 Bond to Mechanically Attached Base Layer:j
Tri-Built Sand-R SA Shingle Underlayment; Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ ASTM D226, Type I or II felt.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam -on tile systems (Tri-Built S/A HT TU
Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-
12).
5.6.4 Wind Resistance for Underlavment Svs
does not address wind uplift resistance
the underlayment forms part of the lo;
underlayment systems that are not add
applications. Maximum Design Press
allowable wind loads, and reflects the i
per FBC 1504.9 has already been appliE
FBC 1609 for determination of design w
#1 Maximum Design Pressure = -45.0 psf:
Deck: Min. 15/32-inch plyi
Having Jurisdiction. I
Primer: (Optional) ASTM D41
Underlayment: Tri-Built S/A HT TU U
#2 Maximum Design Pressure = -67.5 psf j
ems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12)
if all underlayment systems beneath foam -on tile systems, where
i-path. The following wind uplift limitations apply to direct -deck
2ssed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile
re is the result of testing for wind load resistance based on
timate passing pressure divided by 2 (the 2 to 1 margin of safety
). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or
id pressures.
to meet project requirements to satisfaction of Authority
or RESISTO EXTERIOR PRIMER
nderlayment, self -adhered.
Deck:
Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction. I
Primer:
Soprema Elastocol 600c
Underlayment:
Tri-Built S/A HT TU Underlayment, self -adhered.
#3 Maximum Design Pressure = -150.0 psf:
Deck:
Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit
adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp
splinters and wood projections shall be removed/sanded.
Primer:
(Optional) RESISTO EXTERIOR PRIMER
Underlayment:
Tri-Built S/A HTI TU Underlayment, self -adhered, shall be thoroughly roll using hand
roller and/or weighted roller to ensure there are no voids, and ensure there are no
voids/bridging at side and end -laps.
#4 Maximum Desi
Deck:
Base Sheet:
Underlayment:
Exterior Research and Design, I.I.C.
Certificate of Authorization #9503
Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Soprema Soprai-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1)
and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three,
equally spacedl rows in the center of the sheet.
Tri-Built S/A HT TU Underlayment, self -adhered.
Evaluation Report A42960.10.12-116
6°1 EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017
j Page 4 of 6
i
I
I
I
TRINITY ERD
5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet
or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1
design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria.
Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left
exposed for longer than 30-days after installation
Tri-Built S/A HT TU Underlayment shall i of be left exposed for longer than 180-days after installation.
5.8 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)):
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by using battens during loading of the roof
tiles. j
TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS
Underlayment
I
Tile Profile
Staging Method
Maximum
Slope
Flat
Max. 10-tile stack
6:12
Lugged
Max. 10-tile stack
5:12
i
Max. 10-tile stack (bottom 2-tile stack
shall be inverted, followed by 8 tiles high 6:12
on slope, as shown below)
j
f
Tri-Built S/A HT TU
i
Underlayment
Lugged
I
i
1
I
Exterior Research and Design, LLC.
Certificate of Authorization #9503
i
I
I
I
j
I
I
I
I
I
I
e EDITION (2017) FBC NON-HVHZ EVALUATION
TRI-BUILT Roof Underlayments; (800) 516-1485
I
I
I
Evaluation Report A42960.10.12-116
FL16048-R6
Revision 6: 09/25/2017
Page 5 of 6
I
\J\T___R1N1TYjERD
6. INSTALLATION:
6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC
published installation requirements subjeci to the Limitations set forth in Section 5 herein and the
specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to appliIIcation, and prime the substrate (if applicable).
6.3 Tri-Built Sand-R SA Shingle Underlayment iTri-Built S/A HT TU Underlavment or Tri-Built Smooth HT S/A
Underlavment:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
6.3.2 Non -Tile applications:
While priming is optional, TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof
cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Rolll out approximately 10 ft of membrane and peel back the first 3
ft of release film. i
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel -off the release film diagonally while holding the
membrane tight. Firmly roll, broom or hand -press the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below, sealed in accordance with
TRI-BUILT Materials Group, LLC requirements.
When installing at slopes above 8:12, TRI-BUILT Materials Group, LLC recommends back -nailing in the
overlap area at the top of the sheet at 121inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys, apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications (Tri-Built S/A HT TU Un_derlayment only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
For foam -on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012 (04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment. See Table 2 herein, ani TRI-BUILT Materials Group, LLC published requirements for tile
staging.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Gulfport, MS
9. QUALITY ASSURANCE ENTITY:
I
UL, LLC— QUA9625; (314) 578-3406; k.chancellor@us.ul.com
I
- END OF EVALUATION REPORT -
Exterior Research and Design, I.I.C. I Evaluation Report A42960.10.12-R6
Certificate of Authorisation N9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017
1 Page 6 of 6