DIVI90N: 07 00 00—THER\AALAND MOISTUREPROTECTION
SE ON: 07 30 05--ROORNG FELTAND UNDERLAYM ENT
REPORT HOLDER RECEIVED
MAR 15 2018
M FM BUILDING PRODUCTS OORPORA" I ON permitting Department
525 ORANGESTFE7 St. Lucie county
COSHOCTON, OHI O 43812
MAIUNGADDRESS
POST OFFICE BOX 340 F I L E C'
009-IOCTON, OHI O 43812
EVALUATION WELECT
a -- on 0 i A ilim A
_ !` �L�
11CC m 11CC 11CC
e
C�
PMG CLISTED
Look for the trusted marks of Conformity!
"2014 Fbdpient of Prestigious Western gates Seismic Policy Council
(VVSS:lq Award in 6coellence" I ASibsidiaryof
ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not B`C�
specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a
recommendation for its use. 'Mere is no warranty by ICC Evaluation Service, LLC, express or implied, as
Is "cc 17065
to any finding or other matter in this report, or as to any product covered by the report. PmdulcniU.mlroaBoa7 ae wsaN
Copyright ° 2018 ICCEvaluation Srrv!ce, LLG All rightsreserved.
ES
ICC-ES Evaluation Report
ESR-1737
Reissued April 2017
Revised March 6, 2018
This report is subject to renewal April 2019.
www.icc-es.org 1 (800) 423-6587 1 (562) i699-0543 A Subsidiary of the International Code Council®
DIVISION: 07 00 00—THERMAL AND MOISTURE
PROTECTION
Section: 07 30 05—Roofing Felt and Underlaym
REPORT HOLDER:
MFM BUILDING PRODUCTS CORPORATION
525 ORANGE STREET
COSHOCTON, OHIO 43812
(740) 622-2645
www.mfmbi).com
salesCo)_mfmbp.com
MAILING ADDRESS:
POST OFFICE BOX 340
COSHOCTON, OHIO 43812
ADDITIONAL LISTEE:
HUTTIG BUILDING PRODUCTS
555 MARYSVILLE UNIVERSITY DRIVE
SUITE 400
ST. LOUIS, MISSOURI 63141
(800) 325-4466
www.huttig.com
EVALUATION SUBJECT:
MFM IB-3 ICEBUSTER, I13-3 STORMSTO'PPER, I13-3
SHINGLESTARTER, IB-4 STORMSTOPPER,I ULTRA HT
WIND & WATER SEAL TM AND SHINGLESTARTER SELF -
ADHERING UNDERLAYMENTS
1.0 EVALUATION SCOPE
Compliance with the following codes:
112015, 2012, 2009 and 2006 Inte
Code® (IBC)
09-12015, 2012, 2009 and 2006 Intern
Code® (IRC)
Properties evaluated:
€^ Roof underlayment
Mice barrier
€f Fire classification
2.0 USES
IB-3 IceBuster, IB-3 StormStopper, I13-3
4 StormStopper, -Ultra HT Wind & �
Building
Residential
IeStarter, IB-
SeaITP°, and
ShingleStarter are self -adhering membranes used as an
alternative to the ASTM D226 Type I and Type II
underlayments specified in IBC Chapter 15 and IRC
Chapter 9, and an alternate to the ice barrier specified in
IBC Chapter 15 and IRC Chapter 9. I13-3 IceBuster, IB-3
StormStopper, I13-3 ShingleStarter, and IB-4 StormStopper
underlayments are also used as components of classified
roof assemblies when installed in accordance with Section
4.2. Ultra HT Wind & Water SeaITM is limited to use with
nonclassified roof assemblies. See Table 1 for additional
listee product name correlations.
3.0 DESCRIPTION
3.1 General:
IB-3 IceBuster, I13-3 StormStopper, IB-3 ShingleStarter,
IB-4 StormStopper, and ShingleStarter underlayments are
composed of fiberglass -mat reinforcement, modified
asphalt, and mineral fines on the surface. The products are
black in color and have a release 'liner on the back that is
removed prior to attachment to the substrate. The products
are produced in rolls of various lengths.
Ultra HT Wind & Water SealTM is composed of a white,
cross -laminated polymer film, laminated to a high
temperature rubberized asphalt adhesive. The top surface
of the product is white and has a release liner on the back
that is removed prior to attachment to the substrate. The
product is produced in rolls of various lengths.
3.2 I13-3 IceBuster:
I13-3 IceBuster is nominally 50 mils thick [0.050 inch
(1.27 mm)] and is produced in rolls measuring 36 inches
(914 mm) wide.
3.3 IB-3-Storm Stopper:
I6-3 StormStopper is nominally 50 mils thick [0.050 inch
(1.27 mm)] and is produced in rolls measuring 36 inches
(914 mm) wide.
3.4 IB-3 ShingleStarter:
I13-3 ShingleStarter is nominally 50 mils thick [0.050 inch
(1.27 mm)] and is produced in rolls measuring 36 inches
(914 mm) wide.
3.5 IB-4 StormStopper:
IB-4 StormStopper is nominally 60 mils thick [0.060 inch
(1.52 mm)] and is produced in rolls measuring 36 inches
(914 mm) wide.
3.6 ShingleStarter:
ShingleStarter is nominally 50 mils thick [0.050 inch
(1.27 mm)] and is produced in rolls measuring 73/16 inches
(183 mm) wide.
IMES Evaluation Reports are not to be construed as represenhing aesthetics or any other attributes not specifically addressed, nor are they to be construed
as an endorsement ofthe subject ofthe report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as =�
40
to any finding or other matter in this report, or as to any product covered by the report. �� —
Copyright © 2018 ICC Evaluation Service, LLC. All rights reserved. Pagel of 3
ESR-1737 I Most Widely Accepted and 1 ;d
3.7 Ultra HT Wind & Water SeaITM:
Ultra HT Wind & Water SeaITM is nominally 45
(0.045 inch (1.14 mm)] and is produced in rolls
36 inches (914 mm) wide.
4.0 INSTALLATION
4.1 General:
Installation of IB-3 IceBuster, I13-3 StormStopf
ShingleStarter, IB-4 StormStopper, Ultra HT Wind
Seal M, and ShingleStarter must comply with the a
code, this report, and the manufacturer's K
installation instructions. The installation instructic
be available at the jobsite at all times during install
Prior to application of the membrane, the dec
must be free of frost, dust and dirt, loose Paste
other protrusions. Damaged sheathing must be
Installation is limited to plywood substrates comp
the requirements of the applicable code.
The membrane is cut into manageable len
rerolled. The membrane is aligned lengthwise, I
the eave, on the lower edge of the roof; the mei
applied directly to the roof deck by peeling
release liner approximately 1 to 2 feet (305 to
and pressing the membrane firmly in place, from 1
to the edge. End (vertical) seams must be ove
minimum of 6 inches (152 mm). Edge (horizont;
must be overlapped a minimum of 3 inches (102
3 inches (76.2 mm) for Ultra HT Wind & Water SE
subsequent courses of membrane are applied I
the eave, from the lower edge of the roof up%
shingle -lap manner.
If the membrane becomes misaligned, the rol
cut and restarted. After application, the membran
inspected, and any defects repaired. "Fish mouth
pressed flat, and covered with a patch of mer
sufficient width and length to overlap each side a
the slit a minimum of 3 inches (76 mm) (Flat
metal drip edges must be installed, in accordant
applicable code, so as to prevent water backup)
layer of minimum 30-inch-wide (762 mm) and
must be installed and centered vertically on
before installation of the underlayment in the fie
all hips and ridges after installation of the undeil
the field.
thick
wring
, IB-3
Water
iblished
is must
tion.
surface
ors, and
with
is and
allel to
rane is
ck the
0 mm)
center
seams
im) and
TM. The
rallel to
dsina
must be
must be
are slit,
Drane of
d end of
ling and
with the
A single
the valley
Id, and at
ayment in
Installation of an approved roof covering can proceed
immediately following application of the membrane. The
underlayment membrane must is to be covered by
an approved roof covering within the time set forth
in the underlayment manufacturer's published I installation
instructions.
For reroofing application, the same proce
after removal of the existing roof covering and
to expose the roof deck.
4.2 Roof Classification:
Under the 2015, 2012 and 2009 IBC and If
IceBuster, I13-3 StormStopper and I13-4 S
roofing underlayments may be used as coi
classified roof assemblies consisting of Class,
asphalt glass fiber mat shingles or Class C asl
felt shingles complying with the applicable
installed in accordance with this report over
3/8-inch-thick (9.5 mm) plywood deck.
Under the 2006 IBC, the I13-3 IceE
StormStopper and IB-4 StormStoppi
underlayments may be used in Class A or �
apply
i felts
Page 2 of 3
assemblies that utilize the roof coverings specified in the
exceptions to Sections 1505.2 and 1505.3. Under the 2006
IRC, the I13-3 IceBuster, IB-3 StormStopper and I134
StormStopper roofing underlayments may be used with
roof coverings of brick, masonry, slate, clay or concrete
roof tile, concrete roof deck, ferrous or copper shingles or
sheets, and met I sheets and. shingles where such roof
coverings ar e d o be used in lieu of a Class A
assembly under Section R902.1.
Ultra HT Wind & Water SeaITM may be used where
nonclassified roof coverings are permitted.
4.3 Ice Barriers:
One layer of IB-3 IceBuster, IB-3 StormStopper, and Ultra
HT Wind & Water SeaITM, or I13-4 StormStopper may be
used where an ice barrier is required by the code. The
number of courses used must be sufficient to cover from
the eave's edge to a minimum distance of 24 inches
(610 mm) inside the exterior wall line of the building. When
used as underlayments in the field of the roof, the products
recognized in this report must overlap the ice barrier.
4.4 I13-3 ShingleStarter and ShingleStarter:
IB-3 ShingleStarter and ShingleStarter are intended for use
as starter courses for asphalt shingle applications. Use in
this manner must be approved by the shingle manufacturer
and be part of the fire classification listing. The membrane
must be installed as described in Section 4.1 of this report.
End (vertical) and edge (horizontal) seams must be
overlapped a minimum of 6 inches (152 mm). The end and
edge seams must be covered with a uniform, continuous
application of roof mastic to assure a watertight seal prior
to lapping ends. A hand roller must be used to apply firm
uniform pressure over all seams.
5.0 CONDITIONS OF USE
The MFM IB-3 IceBuster, IB-3 StormStopper, IB-3
Shin1OStarter, IB-4 StormStopper, Ultra HT Wind & Water
Seal , and ShingleStarter underlayments described in this
report comply with, or are suitable alternatives to what is
specified in, those codes listed in Section 1.0 of this report,
subject to the following conditions:
5.1 Installation must comply with the applicable code, this
report and the manufacturer's published installation
instructions. In the event of a conflict between this
report and the manufacturer's instructions, this report
governs.
5.2 Installation is limited to plywood substrates for the
IB-3 IceBuster, IB-3 StormStopper, IB-3
ShingleStarter, IB-4 StormStopper, Ultra HT Wind &
Water SeaITM, and ShingleStarter underlayments.
5.3 Installation is limited to roofs with a slope of 2:12
(16.67%) or greater.
5.4 Installation is limited to use with roof coverings that do
not involve hot asphalt or coal -tar pitch.
C, the I13-3 5.5 The I13-3 IceBuster, IB-3 StormStopper, I13-3
:)rmStopper ShingleStarter, IB-4 StormStopper, and
iponents of ShingleStarter underlayments must not be applied
, or Class C when the ambient air and substrate temperatures are
halt organic below 40°F (4.4°C). Ultra HT Wind & Water SeaITM
:ode, when underlayment must not be applied when the ambient
a minimum air and substrate temperatures are below 50°F
(10°C).
aster, IB-3 5.6 Installation is limited to use with approved roof
r roofing coverings that are mechanically fastened through the
lass B roof underlayment to the sheathing or rafters.
ESR-1737 I Most Widely Accepted and 1` ld 1
5.7 Installation is limited to roofs with ventilated attic
spaces in accordance with the requirements of the
applicable code.
5.8 The products are manufactured in Coshocton, Ohio
under a quality -control program with inspections by
ICC-ES.
6.0 EVIDENCE SUBMITTED
6.1 Data in accordance with the ICC-ES Acceptance
Criteria for Roof Underlayments (AC188),I dated
February 2012 (editorially revised December 2015).
6.2 Data in accordance with the ICC-ES Acceptance
Criteria for Self -Adhered Roof Underlayments Ifor Use
as Ice Barriers (AC48), dated February 2012
(editorially revised December 2015).
6.3 Data in accordance with ASTM E 108 as modified by
Section 3.3 of AC188. 1
TABLE 1-
Page 3 of 3
7.0 IDENTIFICATION
The MFM Building Products Corporation underlayments
described in this report are identified by a label on the
container of each roll bearing the manufacturer's name
(MFM Building Products) and address, the manufacturing
location, the product name, and the evaluation report
number (ESR-1737).
The Huttig Building Products underlayments are marked
by a label on the container of each roll bearing the
additional listee's company name (Huttig Building
Products) and address, the manufacturing location, the
Huttig Building Products product name and the evaluation
report number (ESR-1737).
NAME CORRELATION
COMPANY
MFM Building Products
Corporation
Huttig Building Products
IB-3 IceBuster
I
IB-3 IceBuster/Huttig — Grip
IB-3 StormStopper
IB-3 Storm Stopper/Huttig — Grip
PRODUCT
NAME
I13-3 ShingleStarter
IB-3 ShingleStarter/Huttig — Grip
IB-4 StormStopper
I
I13-4 Storm Stopper/Huttig — Grip
ShingleStarter
ShingleStarter/Huttig — Grip