HomeMy WebLinkAboutPRODUCT EVALUATION REPORTPro
GULF COAST
26 Ga. Gulf Rib TM Roof Pan
Flori
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
NE / X.
Gulfc&&
SUPPLY & MANUFACTURING
Evaluation Report
Y & MANUFACTURING, LLC.
over 1x4 Wood Purlins over 15/32" Plywood
'Product Approval #11651.21 R3
Florida Building Code 2017 RECEIVED
Per Rule 61 G20-3
Method: 1 —D MAR 1�18
Permitting Departmen,
Category: Roofing CONCEALED FASTENERS ORMitWNTS
Subcategory: Metal Roofing ARE THE RESPONSIBILITY OF THE
ompliance Method: 61 G20-3.005(1)(d) CONTRACTOR OF RECORD,
NON HVHZ
RLE Copy
Product Manufacturer:
Gulf Coast Supply & Manufacturing, LLC.
14429 SW 2nd Place, Suite G30 %0%J11"/#81,,
Newberry, FL 32669 ��.oPN�EI,, S,• kGy'�
Engineer Evaluator:
Dan Kuhn, P.E. #75519
Florida Evaluation ANE ID: 10743
Validator:
Locke Bowden, P.E. #49704
9450 Alysbury Place
Montgomery AL 36117
No.75519
'
EOF :2.
'O�F••��ORIDP ••���.�
' oNA "�N10/ 05/ 2017
ST. LUCIE COUNTY BUILDI
REVIEWED FOR p�
Contents: RATE EVIEW Y u�
Evaluation Report Pages 1—
LANS AND PERMIT MUST BE KEPT ON 30B
SITE OR NO INSPECTIONS) WILL BE MADE
FL# 11651.21 R3 • OCTOBER 5, 2017
YI••. Orr
.. ..
•
jS.f%J1
_<l.f ��•, t i�/i•�'i f�iJ IJr 1...tt_e 11 J�.:'�f �
DA - PRODUCT APPROVAL Gulf oast
'I SUPPLY & MANUFACTURING
TM
Compliance Statement: The product Ias described in this report has demonstrated compliance with the
Florida Building Code 2017, Sections 1504.3.2, 1504.7.
Product Description:
GulfRibTM 3/4" Rib Roof Panel, Minimum 26 Ga. Steel, 36" Coverage,
through fastened roof panel over Minimum 1x4 Wood Purlins over minimum 1-/32"
Plywood Decking. Non Structural application.
Panel Material/Standards:
Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to
Florida Building Code 2017 Section 1507.4.3.
Paint`/Finish Optional
Yield Strength: Min. 80.Oksi
Corrosion Resistance: Panel Material shall comply with Florida Building
code 2017, Section 1507.4.3.
Panel Dimension(s):
0.018" Minimum
lThickness:
Width: 36" Coverage
Rib Height: 3/4" Major Rib at 9" O.C.
Panel Fastener:
#9-15x1.5" HWH with sealing washing or approved equal
1/4" minimum penetration through plywood.
Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4
Substrate Description:
Minimum 1x4 No. 2 SYP wood purlins over min. 15/3z" thick, APA Rated
plywood over supports at maximum 24" O.C. The 1x4 wood purlins shall be
fastened to the plywood with minimum BD x 2�/z" Ring Shank Nails at 4" O.C.
Design of 1 x4 wood purlins, plywood and plywood supports are outside the
scope of this evaluation. Must be designed in accordance w/ Florida Building
Code 2017.
Design Uplift
FL# 11651.21 R3 r OCTOBER 5. 2017
W14'
Table "A"
Maximum Total Uplift Design Pressure
109.25 psf
164.25 psf
Fastener Pattern
9"-9"-9"-91,
911-9"-9"-9"
Fastener Spacing,
24" O.C.
12" O.C.
Design Pressure includes a Safety Factor = 2.0.
G6ilCoak
FLORIDA
PRODUCT APPROVAL
SUPPLY & MANUFACTURING
G
TIVI
U LFRU B
PANEL OVER • • PURLINS OVER • •
FLORIDA
TM
PRODUCT APPROVAL NO. 11651.21 R
Code Compliance:
The product described erein has demonstrated compliance with the
Florida Building Code �017, Sections 1504.3.2, 1504.7.
Evaluation Report Scope:
The product evaluationis limited to compliance with the structural wind load
requirements of the Florida Building Code 2017, as relates to Rule 61 G20-3.
Performance Standards:
The product described (herein has demonstrated compliance with:
• UL 580-06 - Test for Uplift Resistance of Roof Assemblies
• UL 1897-12 - Uplift Test for Roof Covering Systems.
• FM 4i 71-1992, Section 4.4 Foot Traffic Resistance Test
Reference Data:
1. UL 580-94 / 1897-98 Uplift Test
Force Engineering & Testing, Inc. (FBC Organization # TST-5328)
Report No. 117-0062T--07D & E, Dated 02/19/2007
2. FM 4471-95, ISection 4.4 Foot Traffic Resistance Test
Force Engineering & Testing, Inc. (FBC Organization # TST 5328)
Report No. 117-0238T09D, Dated 07/21/2009
3. Certificate of Independence
By Dan Kuhn, P.E. (FL# 75519) @ Kuhn Engineering, LLC
(FBC Organizlation # ANE ID: 10743)
Test Standard Equivalence:
1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard.
2. The UL 1897198 test standard is equivalent to the UL 1897-12 test
standard. 1
3. The FM 447 -95 test standard is equivalent to the FM 4471-1992 test
standard.
Quality Assurance Entity:
The manufacturer has established compliance of roof panel products in
accordance with the (Florida Building Code and Rule 61 G20-3.005(3) for
manufacturing under a quality assurance program audited by an approved quality
assurance entity.
Minimum Slope Range:
Minimum Slope shall comply with Florida Building Code 2017, including
Section 1507.4.2 and in accordance with Manufacturers recommendations. For
slopes less than 3:1 , lap sealant must be used in the panel side laps.
Installation:
Install per Manufacturer's recommended details.
Underlayment:
Shall comply with Florida Building Code 2017 section 1507.1.1.
FL# 11651.21 R3 • OCTOBER 5, 2017
'C o �'� t
e PRODUCT A...® n Gull
SUPPLY & MANUFACTURING
TM
Roof Panel Fire Classification: Fire classification is not part of this acceptance.
Shear Diaphragm: Shear Diaphragm values pre outside the scope of this report.
Design Procedure:
FL# 11651.21 R3 P OCTOBER 5, 2017
W41"
For roofs within the para
at a minimum meet thos
the parameters listed on
for each project in actor
using allowable stress de
not be exceeded. This ev
Hurricane Zone. Refer to
product in High Velocity
eters listed on the load table, fastening pattern must
listed for the applicable wind zone. For all roofs outside
ie load table, design wind loads shall be determined
rote with FBC 2017 Section 1609 or ASCE 7-10
an. The maximum fastener spacing listed herein shall
uation report is not applicable in High Velocity
urrent NOA or HVHZ evaluation report for use of this
irricane Zone.
Gulf C&M
SUPPLY & MANUFACTURING
ENGINEER LOAD TABLE: 26 Ga. GulfRibTM Panel over 1x4 Wood Purlins over 15/32" Plywood
Buildings having a Roof Mean Height s 20''-0"; Roof Slope: 2' /12 `I - 12 _'/1:2'" Gable or Hip Roof; Wind Speeds 120-
180mph; Exposure C, Risk Category II, Enclosed Building, based o ''Florida Building Code"2`017.` `
120
130
1140 1 150 160
170
180
WIIND
FASTENER
ON CENTER
ON CENTER
ON CENTER ON CENTER ON CENTER'
ON CENTER
ON CENTER
SPEED
(MIN.114"
penetration)
SUBSTRATE
SPACING
SPACING
SPACING SPACING SPACING
SPACING
SPACING
ZONE 1 ,
.
49-15X1.S"
1x4 Wood
Purlins
I, .
24 , TYPE 1
24", TYPE T
24", TYPE 1
24", TYPE 1 '24", TYPE 1
24", TYPE 1
24", TYPE 1
ZONE 2
#9-15x1.5"
1x4 Wood
Purlins
24", TYPE 1
24", TYPE 1
24' TYPE 1
24", TYPE 1 24", TYPE 1
24", TYPE 1
24", TYPE 1
ZONE 3
#9-15X1:5"
1xd4 Woo.
Purlins
24". TYPE 1
24", TYPE 1
24', TYPE 1
24", TYPE 1 34", TYPE 1
'24", TYPE 1 °
24", TYPE 1
1.) PANEL DESCRIPTION: GULFRIBTM, MIN. 26 GA., GRADE 80, 36"COVERAGE, 3/4" TALL.
2.) PANEL FASTENER: #9-15X1.5" HWH WITH SEALING WASHER OR APPROVED EQUAL
3.) MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE: 109.25 PSF @ 24" O.C. FASTENER SPACING TYPE 1 FASTENER PATTERN,
164.25 PSF @ 12" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING.
4.) SUBSTRATE: 1X4 WOOD PURLINS OVER MIN. 1sh2" THICK PLYWOOD. WOOD PURLINS ATTACHED TO PLYWOOD W/ MIN. 8D X
2'/2" RING SHANK NAILS AT 4" O.C. PURLINS AND PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FBC 2017
5.) ROOF SLOPE: ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN'PANEL SIDE LAPS.
6.) LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-1I0 (KD = 0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING
CODE 2017.
ZONE 2 ZONE 3--,:rl
J -
♦� RIDGE
°----------,
ZONE ♦♦ ♦♦♦
Note: Dimension (a) is defined as 10% of the minimum width of the building or
40% of the mean height of the roof, whichever is smaller, however, (a) cannot be
-? a less than either 4% of the minimum width of the building or 3 feet.
TYPE 1 FASTENER PATTERN
1 x 4 Wood Purlins @ 24" O.C. Attached to Plywood with
(1) 8ci x 2.5" Ring Shank Nails @ 4" O.C. At Panel Lap
ZONE 2 GABLE ROOF �a!
—J-----------------1
� I
):a
I ` t
RIDGE
I I
__I
E---------------------4-
I
ZONE 1
i
'i-ZONE 3 EAVE
FL# 11651.21 R3 • OCTOBER 5, 2017
L(1) #9-15 x 1-1121 w/Sealer Washer Min. 15/32. Plywood
Fastener Pattern @ 24" O.C.
TYPE 2 FASTENER PATTERN
1 x 4 Wood Purlins n 12" O.C. Attached to Plywood with
i
(1) 8d jX 2.5" Ring Shank Nails @ 4" O.C. At Panel Lap
L(1) #9I15 x 1-1/2" w/Sealer Washerl—Min- 15/32" Plywood
9'-9"-91,'-9" Fastener Pattern @ 12' O.C.