SCOPE:
This Evaluation Report is issued under Rule 61G21
construction materials in the State of Florida. The 1
P.E. for use of the product under the Florida Bu
products described herein have been evaluated f
sections noted herein.
DESCRIPTION: Boral Roof Underlayments
LABELING: Labeling shall be in accordance with the
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid
Quality Assurance documentation changes, or provisic
this Evaluation Report by the named client constitL
changes or the referenced Quality Assurance docume
Evaluation Report relative to updated Code requireme
ADVERTISEMENT: The Evaluation Report number prece
advertising literature. If any portion of the Evaluation
INSPECTION: Upon request, a copy of this entire Evalua
its distributors and shall be available for inspection at
This Evaluation Report consists of pages 1 through 7.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCAANE1983
GGANNED
BY
SKUdecountf
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
(203)262-9245
Evaluation Report M35710.12.10-119
FL14317-R8
'BE KEPT ON JOB Date of Issuance: 12/21/2010
BE MADE. Revision 9: 10/14/2017
i and the applicable rules and regulations governing the use of
cumentation submitted has been reviewed by Robert Nieminen,
ing Code and. Florida Building Code, Residential Volume. The
compliance with the 6th Edition (2017) Florida Building Code
requirements the Accredited Quality Assurance Agency noted
until such time as the named product(s) changes, the referenced
Ins of the Code that relate to the product change. Acceptance of
tes agreement to notify Robert Nieminen, P.E. if the product
�ntation changes. Trinityl ERD requires a complete review of this
!nts with each Code Cycle.
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any co
3. Robert Nieminen, P.E. does not have nor will acquire, a fin
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a fii
product.
5. This is a building code evaluation. Neither Trinityl ERD nc
project on which this Evaluation Report, or previous versie
specifically for that purpose.
by the words "Trinityl ERD Evaluated" may be displayed in
lort is displayed, then it shall be done in its entirety.
Report shall be provided to the user by the manufacturer or
job site at the request of the Building Official.
The facsimile seal appearing was authorized by Robert
Nieminen, P.E. on 10/14/2017. This does not serve as an
electronically signed document.
or will it acquire, a financial interest in any company manufacturing or
pany manufacturing or distributing products it evaluates.
icial interest in any company manufacturing or distributing products for
al interest in any other entity involved in the approval process of the
Robert Nieminen, P.E. are, in any way, the Designer of Record for any
thereof, is/was used for permitting or design guidance unless retained
CONCIEVAULED ;A OTENERS OR 6CHMSTS
ARE THE Woman
UV awn
Cf%Py
FIL"m
�t
THESE PLANS AND ALL PROPOSED Y,IORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL A-11ING BLE CODES.
\I KINITY I ERD
I
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Boral Roof Underlayments, as marketed by Boral Roofing, have demonstrated compliance
with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the
following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set
forth herein.
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind Uplift UL 1897 2012
1507.1.1, T1507.1.1, 1507.2.9.2 Physical Properties, ASTM D1970 2015
1507.3.3 Physical Properties FRSA/TRI April 2012 (04-12) 2012
3. REFERENCES:
Entitv Examination Reference Date
ERD (TST 604b) Physical Prope ies M36790.07.11 09/30/2011
ERD (TST 6049) Physical Proper�ies 1340380.08.12 08/28/2012
ERD (TST 6049) Tensile Adhesion / LTA C41420.09.12-2 09/11/2012
ERD (TST 6049) Adhesion I B41940.09.12 09/13/2012
ERD (TST 6049) Tensile Adhesion / LTA B47390.07.14-1 07/31/2014
ERD (TST 6049) Tensile Adhesio i / LTA 647390.09.14 09/04/2014
PRI (TST 5878) ASTM D1970 NEI-031-02-02:REV 10/27/2010
PRI (TST 5878) ASTM D1970 NEI-029-02-01:REV 12/03/2010
PRI (TST 5878) Tensile Adhesion / LTA NEI-046-02-01REV 12/17/2010
PRI (TST 5878) FRSA/TRI April 2012 NEI-076-02-01 02/14/2011
PRI (TST 5878) ASTM D1970 NEI-034-02-02 01/29/2013
PRI (TST 5878) Wind Uplift BORR-001-02-01 03/17/2015
PRI (TST 5878) Wind Uplift BORR-005-02-01 06/24/2015
UL, L-C. (QUA 9625) Quality Assuranc Service Confirmation Exp. 08/21/2020
4. PRODUCT DESCRIPTION:
4.1 Self -Adhering Underlayments:
4.1.1 Boral TileSeal® 50"T is a nominal 50-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof
underlayment; meets ASTM D1970.
4.1.2 Boral TileSeal® HT is a nominal 60-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI 04-12.
4.1.3 GatorSeal® is a nominal 55-mil thick, grlanular-surfaced, fiberglass reinforced, self -adhering SBS modified
bitumen roof underlayment; meets ASTM D1970.
4.1.4 Citadel® Plus is a nominal 48-mil thick, fabric -surfaced, fiberglass reinforced, self -adhering SBS modified
bitumen roofing underlayment for use as a base -layer in two-ply underlayment systems; meets ASTM
D1970.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance u I less retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
Exterior Research and Design, U.C. Evaluation Report M35710.12.10-119
Certificate of Authorization #9503 6T.. EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-118
Boral Roof Underlay it ents; (602) 269-2288 Revision 9: 10/14/2017
Page 2 of
5.3 Fire Classification is not part of thi.
Directory for fire ratings of this produ
5.4 Boral Roof Underlayments may be i
referenced within FBC approval docu
Jurisdiction for approval based on th
covering.
5.5 Allowable Roof Covers: Table 1 perl
roof covers. Refer to the installation i
5.5.1
_)0
TRINITY I ERD
Laboratory keport; refer to current Approved Roofing Materials
!d with anylprepared roof cover where the product is specifically
ants. If not listed, a request may be made to the Authority Having
evaluation combined with supporting data for the prepared roof
ins to use of each listed underlayment by -itself beneath the stated
structio6s and Table 2 for two-ply underlayment options.
TABLE 1: ROOF COVER OPTIONS
Underlayment
Asphalt'
Nail -On Tile
Adhesive -set
Metal
Wood Shakes
Slate
Shingles. ,
Tile
& Shingles
Boral TileSeal 50"T
Yes
j
No
No
Yes
Yes
Yes
Boral TileSealIT ,
Yes
' Yes
Yes
Yes
Yes
Yes
I
II!
(See 5,.5.1)
GatorSeal
Yes
�*.
. No
No
No
Yes
Yes
"Adhesive -set Tile" is limited to use of following Approved tile adhesives / underlayment combinations.
TABLE 1A: ALLOWAB
LE, TILE ADHESIVE / UNDERLAYMENT COMBINATIONS)
Adhesive
Florida Product Approval
Underlayments
DAP Foam Touch'n Seal StormBond Roof Tile
Adhesive
FL14506
Boral TileSeal"T
Dow TILE BONDTm Roof Tile Adhesive
FL22525
Boral TileSealIT
ICP Adhesives Polyset® AH-160
I
FL6332
Boral TileSeal"T
ICP Adhesives Polyset® RTA-1
I
FL6276
Boral TileSeal IT
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Citadel Plus, Boral TileSeal 50"T,.Boral (TileSeal- or GatorSeal:
➢ Plywood (unprimed or primed with ASTM D41 primer).
Boral TileSeal"T:
➢ OSB primed with ASTM D41 primer.
Note: Refer to Section 5.6.4 for uplift 1
where the overlying roof cover is adhesit
5.6.2 Bond to Base Laver Underlayment:
Citadel Plus, Boral TileSeal 50"T, Boral'
➢ ASTM D226, Type II felt; Citadel F
For installations under mechanically atl
minimum codified requirements. For i
attached per minimum requirements of
Section 5.6.4 herein, or as tested in accc
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's
Exterior Research and Design, I.I.C.
Certificate ofAuthoriration #9503 6T" EDITION.(2017) FBC
Boral Roof Underlavi
:ions associated with direct -deck underlayment installations
tile roofing .
I"T or GatorSeal:
ached prepared roof coverings, base layer shall be attached per
istallations under adhesive -set tile systems, base layer shall be
FRSA/TRI April 2012 (04-12), Appendix A. Table 1, or as listed in
dance with FBC 1504.3.1.
Product Approval for Overturning Moment Resistance Performance
Evaluation Report M35730.12.10-R9
•HVHZ EVALUATION FL14317-R8
s; (602) 269-2288 Revision 9:10/14/2017
Page 3 of 7
5.6.3 Bond to Other Substrate Types:
Citadel Plus, Boral TileSeal 50'T Bor
➢ -ASTM D41 primed metal (e.g.,.i
Boral TileSeal"T:
➢ Huber Zip Deck (unprimed or p
Note: For installation- under mechani
per minimum requirements of the prt
5.6.4 Wind Resistance for Underlavment S
does not address wind uplift resistar
where the underlayment forms pare
underlayment systems that are not a(
tile applications. Maximum Design
allowable wind loads, and reflects thi
per FBC 1504.9 has already been app
FBC 1609 for determination of design
#1 Maximum Desien Pressure = -105 nsf:
Deck: Min. 15/32-inch pl
Having Jurisdiction.
Base Ply: (Optional) Citadel P
Underlayment: Boral TileSeal"T, sel
12 ga. x 1%" ring sh
#2 Maximum Desien Pressure = -120.0 ns
Deck:
Min. 15/32-inch pl
Having Jurisdiction.
Primer:
ASTM D41 to the pl
Base Ply:
Citadel Plus, self -ad
Cap Sheet:
Boral TileSeal"T, sel
12 ga. x 1%" ring sh
QOTRINITY'l-ERD
TileSeal"T or GatorSeal:
shing metal, valley metal, etc).
med with ASTM D41 primer); Dens Deck Prime.
ally attached prepared roof coverings, insulation shall be attached
cared roof covering manufacturer's Product Approval.
tems in Adhesive -set Tile Applications: FRSA/TRI April 2012 (04-12)
:e of all underlayment systems beneath adhesive -set tile systems,
of the load -path. The following wind uplift limitations apply to
tressed in FRSA/TRI April 2012 (04-12) and are used in adhesive -set
ressure is the result of testing for wind load resistance based on
ultimate passing pressure divided by 2 (the 2 to 1 margin of safety
ed). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or
vind loads
d to meet project requirements to satisfaction of Authority
us; self -adhered
'-adhered and back -nailed within the selvedge -edge side laps using
nk nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
to meet project requirements to satisfaction of Authority
od deck
adhered, and back -nailed within the selvedge -edge side laps using
nk nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
#3 Maximum Design Pressure = -202.5 osf:
Deck: Min. 15/32-inch plywood to - meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: ASTM D41 to the plywood deck
Base Ply: None
Cap Sheet: Boral TileSeal"T, self -adhered, and back -nailed within the selvedge -edge side laps using
12 ga. x 1" ring sha %nk nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
#4 Maximum Design Pressure = -120.0 psf:
Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of
Authority Having Jurisdiction.
Primer: ASTM D41 to the concrete deck
Base Ply: (Optional) Citadel Plus, self -adhered
Cap Sheet: Boral TileSeal"T, selfTadhered
5.6.4.1 Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the
project design pressure requirements may not exceed -120 psf.
Exterior Research and Design, LLC.
Certificate of Authorization #9503
6'" EDITION (2017) F8C NON-HVHZ EVALUATION
Boral Roof Underpayments; (602) 269-2288
Evaluation Report M35710.12.10-119
FL14317-R8
Revision 9:10/14/2017
Page 4 of 7
5.7 Exposure Limitations:
batorSeal shall not be left exposed
roof cover.
5.8
QOTRINHYJ ERD
longer than 30-days after installation, prior to placement of final
Boral 'TileSeal SO"T and Boral.TileSealIT shall not be -left exposed for longer than 180-days after
installation, prior to placement of final roof cover.
Citadel Plus, for use as a base -layer in a two-ply underlayment system, shall not be left exposed for longer
than 180-days after installation, prior to placement of subsequent underlayment layer.
When loading roof tiles on the underpayment in direct -deck tile assemblies, the maximum roof slope shall
be as follows. These slope limitation can only be exceeded.by using battens during loading of the roof
tiles.
TABLE 2: TILE SLIPPAGE LIMITATIONS
FOR DIRECT -DECK TILE INSTALLATIONS
Underlayment
Tile Profile
Stagging Method
Maximum Slope
Boral TileSeal"T
Flat
Max. 10-tile stack
6:12
Lugged
Max. 10-tile stack
6:12
6. INSTALLATION:
6.1 Boral Roof Underlayments shall be installed in accordance with Boral Roofing published installation
instructions subject to the Limitations set forth in Section 5 he and the specifics noted below.
6.2 Re -fasten any loose decking panels, a' d check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior tol application, and prime the substrate (if applicable).
6.3 Install self -adhering underlayment when ambient and surface temperatures are minimum 40°F and rising.
6.4 Citadel Plus:
6.4.1 Citadel Plus is limited to use as a base or mid -layer in multi -ply underlayment systems beneath Boral
TileSeal 50"T, Boral TileSeal IT or GatorSeal.
6.4.2 Slope limitations are those associated with the top -layer underlayment.
6.4.3 Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof
edge, extending over by %-inch. Fold the membrane away from the edge onto itself. Remove the release
sheet. Place the membrane with the �Ixposed rubberized asphalt onto the deck, pressing firmly into place.
Roll into place with a weighted roller.
Boral recommends fastening of the top edge of the sheet to the deck with roofing nails, nails & tin -tags or
1-inch diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for
slopes 7:12 and greater. Overlap successive courses minimum 2 inches (horizontal lap) and minimum 4"
end (vertical) laps.
Install final underlayment layer atop Citadel Plus per 'direct -to -deck' instructions for Boral TileSeal 50"T,
Boral TileSealIT or GatorSeal.
6.4.4 To Base Sheet:
Install base sheet of ASTM D226, Type II felt in accordance with Code requirements or install base ply of
Citadel Plus in accordance with Bora' Roofing published. installation instructions and Section 6.4.3 and
when used as part of a multi -ply system.
Install optional Citadel Plus as amid -ply in accordance with Boral Roofing published installation
instructions and Section 6.4.3.
Install final underlayment layer atop Citadel Plus .per 'direct -to -deck' instructions for Boral TileSeal 50"T,
Boral TileSealIT or GatorSeal.
Exterior Research and Design, LLC. Evaluation Report M35730.12.10-119
Certificate ofAuthori:ation #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-RB
Boral Roof Underpayments; (602) 269-2288 Revision 9: 10/14/2017
Page 5 of 7
C)o
TRINITYJ-ERD
Note: For adhesive -set tile. systems if there is a base ply or mid -ply of Citadel Plus in the system, the
project design pressure requirements may not exceed -120 psf.
6.5 ' Boral TileSeal 50"T: [
6.5.1 Shall be installed in compliance w;th the requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
6.5.2 Do not use Boral TileSeal 50"T.on roof pitches less than 2:12.
6.5.3 Non -Tile Applications. Direct to Deck:
6.5.4
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof
edge, extending over by %-inch. Fold the membrane away from the edge onto itself. Remove the release
sheet. Place the membrane with thel exposed rubberized asphalt onto the deck, pressing firmly into place.
Roll into place with a weighted rolled.
Boral recommends fastening of the Black selvedge edge to the deck with roofing nails, nails & tin -tags or 1-
inch diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes
7:12 and greater. Overlap successive courses the width of the black -selvedge area, minimum 3-inch.
Seal under end (vertical) laps using approved mastic, or use Joined'and Folded Seam or Inverted Sheet
Seam method detailed in Boral Roofing published installation instructions.
Install ASTM D226, Type II felt in ac
with Boral Roofing published instalk
Install Boral TileSeal 50"T in accord
published installation instructions ai
Apply SBS Mastic under all end (i
underside is in contact with the fabi
ordance with Code requirements or install Citadel Plus in accordance
ion instructions and Section 6.4.
nce over ASTM D226, Type II felt or Citadel Plus with Boral Roofing
i Section 6.5.3, except end (vertical) laps, described below.
!rtical) laps or any other laps where the self -adhering bituminous
: top surface, rolling the interface into place with a weighted roller.
6.6 GatorSeal:
6.6.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
6.6.2 Do not use GatorSeal on roof pitches less than 2:12.
6.6.3 Non -Tile applications. Direct to Deck['
6.6.4
Cut the membrane into manageabl
edge, extending over by %-inch. Fo
sheet. Place the membrane with th
Roll into place .with a weighted roll(
lengths, typically 10 to 12 ft. Align the membrane parallel to the roof
the membrane away from the edge onto itself. Remove the release
exposed rubberized asphalt onto the deck, pressing firmly into place.
Boral recommends fastening of the black selvedge edge to the deck with roofing nails, nails & tin -tags or 1-
inch diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes
7:12 and greater. Overlap successive courses the width of the black -selvedge area, minimum 3-inch.
Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps where the self -
adhering bituminous underside is in contact with the granular or mineral top surface, rolling the interface
into place with a weighted roller, or using the Inverted Sheet Seam detailed in Boral Roofing published
installation instructions.
Install ASTM D226, Type II felt in accordance with Code -requirements or install Citadel Plus in accordance
with Boral Roofing published installation instructions and Section 6.4.
Install GatorSeal over ASTM D226, Type II felt or Citadel Plus in accordance with Boral Roofing published
installation instructions and Section 6.6.3 except end (vertical) laps, described below.
Apply SBS Mastic under all side ( Iertical) laps or any other laps where the self -adhering bituminous
underside is in contact with the granular top surface,. rolling the interface into place with a weighted roller.
Exterior Research and Design, U.C. Evaluation Report M35710.12.30-R9
Certificate of Authorization #9503 6TN EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R8
Boral Roof Un ierlayments; (602) 269-2288 Revision 9: 10/14/2017
Page, 6 of 7
QTRINITYIERD
6.7 Boral TileSeal "T:
6.7.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
6.7.2 Do not use Boral TileSeal "Ton roof pitches less than 2:12.
6.7.3 Non -Tile Applications. Direct to Deck:l
6.7.4
For OSB substrate, prime with ASTM
into manageable lengths, typically 1
over by %-inch. Fold the membrane
membrane'with the exposed rubber
with a weighted roller.
Boral recommends fastening of the L
inch diameter plastic or steel cap nai
7:12 and greater. Overlap successive
Seal under end (vertical) laps using
Seam method detailed in Boral Roofi
41 primer and allow to dry prior to installation. Cut the membrane
to 12 ft. Align the membrane parallel to the roof edge, extending
iay from the edge onto itself. Remove the release sheet. Place the
!d asphalt onto the deck, pressing firmly into place. Roll into place
ack selvedge edge to the deck with roofing nails, nails & tin -tags or 1-
spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes
courses the width of the black -selvedge area, minimum 3-inch.
Ipproved mastic, or use Joined and Folded Seam or Inverted Sheet
e Dublished installation instructions.
Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance
with Boral Roofing published installation instructions and Section 6.4.
Install Boral TileSeal HT over ASTM �1)226, Type II felt or Citadel Plus in accordance with Boral Roofing
published installation instructions and Section 6.7.3, except end (vertical) laps, described below.
Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous
underside is in contact with the fabric top surface, rolling the interface into place with a weighted roller.
6.7.5 Tile Applications:
Reference is made to FRSA/TRI Al
instructions noted above as a guidel
For mechanically fastened tile roof
sheet(s), Base Sheet fastening shall
For adhesive -set tile applications, re
2012 (04-12) Installation Manual and Table 1 herein, using the
over 2-ply system, consisting of Base Sheet and self -adhering top
not less than FRSA/TRI April 2012 (04-12), Table 1.
to Section 5.6.4 herein.
Note: For adhesive -set the systems if there is a base ply or mid -ply of Citadel Plus in the system, the
project design pressure requirements may not exceed -120 psf.
Refer to Section 5.8 for tile staging limitations. Battens must be used for all tile installations atop Boral
TileSeal HT with roof pitches of 2% to less than 3:12. Boral Roofing's Elevated Batten System or counter
battens are required.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Auth
this product.
8. MANUFACTURING PLANTS:
Brentwood, NH
9. QUALITY ASSURANCE ENTITY:
UL, LLC. — QUA9625; (631) 546-2458;
Having Jurisdiction in order to properly evaluate the installation of
- ENDIOF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report M35710.12.10-R9
Certificate ofAuthorizotlon #9503 6TN EDITION (201,) FBC NON-HVHZ EVALUATION FL14317-118
Boral Roof UnIderlayments; (602) 269-2288 Revision 9:10/14/2017
Page.7 of 7