HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTSfill
- =-
Professional Regulation
BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts Publications FBC Staff BCIS Site Map I Links Search
a
Product Approval
Florid
r0 nt'� USER: Public User
ERcdJvrJ12�C.tm
Product Approval Menu > Product or Application Search > lic___n List > Application Detail
OFFICE OF THEFI L # CFL5259cB27
SECRETARY Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived 0
Product Manufacturer IP`QLYGLASS_USA.'_
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954) 233-1378 Ext 242
alender@polyglass.com
Authorized Signature Ariel Lender
alender@polyglass.com
Technical Representative Maury Alpert
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(912) 429-8610
MAIpert@polyglass.com
Quality Assurance Representative Ariel Lender
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954)233-1230
ALende r@ polyg lass .co m
Category, R0000fing�
,Su licate--gfory:•'_,, Qnderlayments-
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
0 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who ddveloped the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/05/2018
Validated By r John W. Knezevich, PE `
Z Validation Checklist - Hardcopy Received
Certificate of Independence FL525g_R27 COI 2017_01 COI_Nieminen.gd
Referenced Standard a ' d Year (of Standard) Standard
Year
ASTM D1970
2015
ASTM D226
2009
ASTM D6164
2011
ASTM D6222
2011
FM 4474
2011
FRSA/TRI April 2012
2012
TAS 103
1995
Q"TRINITYIERD
EVALUATION REPORT
Polyglass USA, Inc.
150 Lyon Drive
Fernley, NV 98408
(570) 384-1230
SCOPE:
EXTERIOR RESEARCH & DESIGN, I.I.C.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
(203) 262-9245
Evaluation Report P12060.02.09-1123
FL5259-R27
Date of Issuance: 02/24/2009
Revision 23: 09/14/2017
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted
herein
DESCRIPTION. Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
-Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality,Assurance documentation changes. TI initylERD requires a complete review of this Evaluation Report
relative to updated'Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 14.
Prepared by:
5rR ?.�y5?4°i9�•
y
Robert J.M. Nieminen, P.E. `-°
.....
Florida Registration No. 59166, Florida DCAANE1983
i.0?ua��r 4; .
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on 09/14/2017. This does not serve as an electronically
signed document.
CERTIFICATION OF INDEPENDENCE:
1. TrinityJERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a fina cial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous version i thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
V TRINfjYIERD
Ent
Examination l
Reference
Date
ERD (TST 6049)
Physical Properties
P40390.08.12-1
08/06/2012
ERD (TST 6049)
Physical Properties
P40390.08.12-2
08/07/2012
ERD (TST 6049)
Physical Properties
C41420.09.12-3
09/11/2012
ERD (TST 6049)
Wind Uplift
P39680.03.13
03/04/2013
ERD (TST 6049)
Physical Properties
P45370.04.13
04/26/2013
ERD (TST 6049)
Wind Uplift
P1738.02.07-R2
04/29/2013
ERD (TST 6049)
Wind Uplift
11757.04.01-1-R1
04/30/2013
ERD (TST 6049)
Wind Uplift
P41630.08.13
08/06/2013
ERD (TST 6049)
Wind Uplift
P11751.05.03-R1
11/26/2013
ERD (TST 6049)
Wind Uplift
P11781.11.03-R1
11/26/2013
ERD (TST 6049)
Physical Properties
P45270.05.14
05/12/2014
ERD (TST 6049)
Physical Properties
6020.07.14-1
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-2
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-3
09/08/2014
ERD(TST 6049)
Physical Properties
6020.09.14-4
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-5
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-6
09/08/2014
ERD (TST 6049)
Physical Properties
P46520.10.14
10/03/2014
ERD (TST 6049)
Physical Properties
P44360.10.14
10/07/2014
ERD (TST 6049)
Physical Properties
P43290.10.14
10/17/2014
ERD (TST_ 6049)
Physical Properties
PLYG SC7550.03.15
03/24/2015
ERD (TST 6049)
Physical Properties
P40390.04.15
04/03/2015
ERD (TST 6049)
Physical Properties
PLYG-SC8080.05.15-1
05/20/2015
ERD (TST 6049)
Wind Uplift
PLYG-SC8905.05.16-1
05/17/2016
ERD (TST 6049)
Physical Properties
PLYG-SC8080.07.16
07/16/2016
ERD (TST 6049)
Wind Uplift I
PLYG-SC12025.10.16
10/12/2016
ERD (TST 6049)
Physical Propertied
PLYG-SC13040.12.16
12/27/2016
ERD (TST 6049)
Physical Properties
PLYG-SC11900.03.17
03/10/2017
ERD (TST 6049)
Physical Properties
PLYG-SC12115.08.17
08/08/2017
ICC-ES (EVL 2396)
IBC Compliance I
ESR-1697
11/01/2014
Miami -Dade (CER 1592)
HVHZ Compliance
NOA 14-0717.08
01/22/2015
Polyglass USA
Manufacturing Affidavit
Products Current
02/18/2009
Polyglass USA
P/L Affidavit
Mule -Hide Cross Ltg
03/01/2008
Polyglass USA
Materials Affidavit
Polystick SA Compound
08/18/2011
UL, LLC. (QUA9625)
Quality Control
Service Confirmation
Exp. 10/05/2018
4. PRODUCT DESCRIPTION:
14.1 Mechanically Fastened Underlayments:
4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet.
4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet.
4.1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet.
4.1.4 Polyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet.
4.2 Self -Adhering Underlayments: 1
4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced
with polyolefinic film surface; meets TAS 103.
4.2.3 Polystick TU Plus is a nominal 80-mil thick rubber'
polyester fabric surface; meets ASTIVI D1970 and l
Exterior Research and Design, LLC.
Certificate of Authorization #9503 67H EDITION (2017) FBC
Polyglass Roof Underl;
I asphalt waterproofing membrane, glass fiber reinforced, with a
103.
Evaluation Report P12060.02.09-R23
iZ EVALUATION FL5259-R27
(570) 384-1230 Revision 23: 09/14/2017
Page 3 of 14
v I RINITY I ERD
5.5 Allowable Roof Covers:
TABLE 1,1 ROOF COVER OPTIONS
Underlayment
Asphalt Shingles
Nail -On Tile I
Foam -On Tile
Metal
Wood Shakes
& Shingles
Slate
Elastobase
Yes
Yes
(Base Sheet in 2-ply sy, m)
Yes
(Base Sheet in 2-ply system)
Yes
Yes
Yes
Elastobase P
Yes
Yes I
(Base Sheet in 2-pty system)
Yes
(Base Sheet in 2-ply system)
Yes
Yes
Yes
Polyglass G2 Base
No
Yes I
(Base Sheet in 2-ply system)
Yes
(Base Sheet in 2-ply system)
No
No
No
Polyglass APP Base
No
Yes I
(Base Sheet in 2-ply system)
Yes
(Base Sheet in 2-pty system)
No
No
No
Polystick MTS
Yes
Yes
No
Yes
Yes
Yes
P,olystick IR:xe
Yes
Na
No
No
No
Yes
Yes
Yes
Yes
PolystickTU P
Yes
Yes
Yes (See 5.5.1)
PolystickTU Plus
Yes
Yes
Yes (See 5-5.1)
Yes
Yes
Yes
PolystickTU Max
No
Yes
Yes (See 5.S.1)
Yes
No
No
Polystick Dual Pro
Yes
No
No
Yes
Yes
Yes
Polystick Tile Pro
Yes
Yes
Yes (See S.S.1)
Yes
Yes
Yes
Polystick MU-X
Yes
No
No
Yes
Yes
Yes
Elastoflex S6 G
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Elastoflex S6 G FR
Yes
Yes
No
No
Yes
Yes
Elastoflex GTU
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polyflex G
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polyflex G FR
Yes
Yes
No
No
Yes
Yes
Polyflex SAP or SAP FR
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Mule -Hide SA-APP Cap Sheet
or SA-APP Cap Sheet (FR)
Yes
Yes I
Yes (See 5.5-1)
No
Yes
Yes
5.5.1 "Foam -On Tile" is limited to use of the following Approved the adhesives / underlayment combinations.
TABLE 1A:
ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS)
Adhesive
Florida Product
I Underlayments
Approval
DAP Foam Touch `n Seal StormBond Roof
FL14506
Polystick TU Plus, Polystick TU Max
Tile Adhesive
DowTileBond'"
FL22525
PolystickTU P, PolystickTU Plus, Polyflex SAP or Tile Pro
PolystickTUP, PolystickTU Plus, PolystickTU Max, Polystick Tile Pro,
ICP Adhesives Polyset® AH-160
FL6332
Ellastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR,
Mlle -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
ICP Adhesives Polyset® RTA-1
FL6276
Elastoflex G TU, Elastoflex SIS G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR,
M l le -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
Polyglass PolyLok Roof Tile Adhesive
FL17855
Polystick TU Plus or Polystick TU Max
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product
Exterior Research and Design, I.I.C.
Certificate of Authorization #9503 6EDITION (2017) FBC NO
Polyglass Roof Undedayrr
for Overturning Moment Resistance Performance.
iZ EVALUATION
(570) 364-1230
Evaluation Report P12060.02.09-1123
FL5259-R27
Revision 23: 09/14/2017
Page 5 of 14
6.4.1
6.4.2
6.4.3
Shall be installed in compliance with the coi
for the type of prepared roof covering to be
All self -adhering materials, with the exception
Cap Sheet or SA APP Cap Sheet (FR) should be
Hide Back Nailing Guide. Nails shall be corrosic
metal disk or Simplex -type metal cap nail, at
using the above noted fasteners and spacing, i
The head lap membrane is to cover the area bE
All seal -lap seams (selvage laps) must be
firmly rolled with a minimum 28 lb. hand
roller to ensure full contact and adhesion.
For Dual Pro and Tile Pro, align the edge of
the top sheet to the end of the glue pattern
(the sheet will overlap the fabric).
C�o
,I TPJNITYIERD
requirements for ASTM D1970 underlayment in FBC Table 1507.1.1
led.
of Polystick TU Plus, Polyflex SAP or SAP FIR and Mule -Hide SA-APP
back -nailed in selvage edge seam in accordance with Polyglass / Mule-
n resistant, 11 gauge ring -shank type with a minimum 1-inch diameter
3 minimum rate of 12" o.c. Polystick TU Plus should be back -nailed
i area marked "nail area, area para clavar" on the face of membrane.
ne back -nailed.
View of Ovelap Seam of Dual Pro and Tile Pro
All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified
Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap.
Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys,
or exposed roof to wall details
Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or
Polyglass PG500 Modified Cement to the are Ia in need of repair, followed by a minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be
installed in a water shedding manner.
All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the
roof that are not accessible to a large roller or broom.
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base
Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1.
For adhesive -set tile applications, refer to Section 5.6.4 herein.
For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile.
6.4.4 Two (2) Ply Underlayment Systems:
Polystick MTS followed by Polystick MTS, TU P, TU Plus, TU Max, Tile Pro, MU-X or Polyflex SAP is allowable for use
under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material.
This is not a requirement, but is allowable if a 2-�ply underlayment system is desired.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R23
Certificate of Authorization#9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
PoWlass Roof Unde'dayments, (570) 384-1230 Revision 23: 09/14/2017
Page 12 of 14