Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTSfill - =- Professional Regulation BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts Publications FBC Staff BCIS Site Map I Links Search a Product Approval Florid r0 nt'� USER: Public User ERcdJvrJ12�C.tm Product Approval Menu > Product or Application Search > lic___n List > Application Detail OFFICE OF THEFI L # CFL5259cB27 SECRETARY Application Type Revision Code Version 2017 Application Status Approved Comments Archived 0 Product Manufacturer IP`QLYGLASS_USA.'_ Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1378 Ext 242 alender@polyglass.com Authorized Signature Ariel Lender alender@polyglass.com Technical Representative Maury Alpert Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (912) 429-8610 MAIpert@polyglass.com Quality Assurance Representative Ariel Lender Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954)233-1230 ALende r@ polyg lass .co m Category, R0000fing� ,Su licate--gfory:•'_,, Qnderlayments- Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who ddveloped the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/05/2018 Validated By r John W. Knezevich, PE ` Z Validation Checklist - Hardcopy Received Certificate of Independence FL525g_R27 COI 2017_01 COI_Nieminen.gd Referenced Standard a ' d Year (of Standard) Standard Year ASTM D1970 2015 ASTM D226 2009 ASTM D6164 2011 ASTM D6222 2011 FM 4474 2011 FRSA/TRI April 2012 2012 TAS 103 1995 Q"TRINITYIERD EVALUATION REPORT Polyglass USA, Inc. 150 Lyon Drive Fernley, NV 98408 (570) 384-1230 SCOPE: EXTERIOR RESEARCH & DESIGN, I.I.C. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT#13 OXFORD, CT 06478 (203) 262-9245 Evaluation Report P12060.02.09-1123 FL5259-R27 Date of Issuance: 02/24/2009 Revision 23: 09/14/2017 This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein DESCRIPTION. Polyglass Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced -Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality,Assurance documentation changes. TI initylERD requires a complete review of this Evaluation Report relative to updated'Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 14. Prepared by: 5rR ?.�y5?4°i9�• y Robert J.M. Nieminen, P.E. `-° ..... Florida Registration No. 59166, Florida DCAANE1983 i.0?ua��r 4; . The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 09/14/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. TrinityJERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a fina cial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous version i thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. V TRINfjYIERD Ent Examination l Reference Date ERD (TST 6049) Physical Properties P40390.08.12-1 08/06/2012 ERD (TST 6049) Physical Properties P40390.08.12-2 08/07/2012 ERD (TST 6049) Physical Properties C41420.09.12-3 09/11/2012 ERD (TST 6049) Wind Uplift P39680.03.13 03/04/2013 ERD (TST 6049) Physical Properties P45370.04.13 04/26/2013 ERD (TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013 ERD (TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013 ERD (TST 6049) Wind Uplift P41630.08.13 08/06/2013 ERD (TST 6049) Wind Uplift P11751.05.03-R1 11/26/2013 ERD (TST 6049) Wind Uplift P11781.11.03-R1 11/26/2013 ERD (TST 6049) Physical Properties P45270.05.14 05/12/2014 ERD (TST 6049) Physical Properties 6020.07.14-1 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-2 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-3 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-4 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-5 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-6 09/08/2014 ERD (TST 6049) Physical Properties P46520.10.14 10/03/2014 ERD (TST 6049) Physical Properties P44360.10.14 10/07/2014 ERD (TST 6049) Physical Properties P43290.10.14 10/17/2014 ERD (TST_ 6049) Physical Properties PLYG SC7550.03.15 03/24/2015 ERD (TST 6049) Physical Properties P40390.04.15 04/03/2015 ERD (TST 6049) Physical Properties PLYG-SC8080.05.15-1 05/20/2015 ERD (TST 6049) Wind Uplift PLYG-SC8905.05.16-1 05/17/2016 ERD (TST 6049) Physical Properties PLYG-SC8080.07.16 07/16/2016 ERD (TST 6049) Wind Uplift I PLYG-SC12025.10.16 10/12/2016 ERD (TST 6049) Physical Propertied PLYG-SC13040.12.16 12/27/2016 ERD (TST 6049) Physical Properties PLYG-SC11900.03.17 03/10/2017 ERD (TST 6049) Physical Properties PLYG-SC12115.08.17 08/08/2017 ICC-ES (EVL 2396) IBC Compliance I ESR-1697 11/01/2014 Miami -Dade (CER 1592) HVHZ Compliance NOA 14-0717.08 01/22/2015 Polyglass USA Manufacturing Affidavit Products Current 02/18/2009 Polyglass USA P/L Affidavit Mule -Hide Cross Ltg 03/01/2008 Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011 UL, LLC. (QUA9625) Quality Control Service Confirmation Exp. 10/05/2018 4. PRODUCT DESCRIPTION: 14.1 Mechanically Fastened Underlayments: 4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet. 4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet. 4.1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet. 4.1.4 Polyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet. 4.2 Self -Adhering Underlayments: 1 4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with polyolefinic film surface; meets TAS 103. 4.2.3 Polystick TU Plus is a nominal 80-mil thick rubber' polyester fabric surface; meets ASTIVI D1970 and l Exterior Research and Design, LLC. Certificate of Authorization #9503 67H EDITION (2017) FBC Polyglass Roof Underl; I asphalt waterproofing membrane, glass fiber reinforced, with a 103. Evaluation Report P12060.02.09-R23 iZ EVALUATION FL5259-R27 (570) 384-1230 Revision 23: 09/14/2017 Page 3 of 14 v I RINITY I ERD 5.5 Allowable Roof Covers: TABLE 1,1 ROOF COVER OPTIONS Underlayment Asphalt Shingles Nail -On Tile I Foam -On Tile Metal Wood Shakes & Shingles Slate Elastobase Yes Yes (Base Sheet in 2-ply sy, m) Yes (Base Sheet in 2-ply system) Yes Yes Yes Elastobase P Yes Yes I (Base Sheet in 2-pty system) Yes (Base Sheet in 2-ply system) Yes Yes Yes Polyglass G2 Base No Yes I (Base Sheet in 2-ply system) Yes (Base Sheet in 2-ply system) No No No Polyglass APP Base No Yes I (Base Sheet in 2-ply system) Yes (Base Sheet in 2-pty system) No No No Polystick MTS Yes Yes No Yes Yes Yes P,olystick IR:xe Yes Na No No No Yes Yes Yes Yes PolystickTU P Yes Yes Yes (See 5.5.1) PolystickTU Plus Yes Yes Yes (See 5-5.1) Yes Yes Yes PolystickTU Max No Yes Yes (See 5.S.1) Yes No No Polystick Dual Pro Yes No No Yes Yes Yes Polystick Tile Pro Yes Yes Yes (See S.S.1) Yes Yes Yes Polystick MU-X Yes No No Yes Yes Yes Elastoflex S6 G Yes Yes Yes (See 5.5.1) No Yes Yes Elastoflex S6 G FR Yes Yes No No Yes Yes Elastoflex GTU Yes Yes Yes (See 5.5.1) No Yes Yes Polyflex G Yes Yes Yes (See 5.5.1) No Yes Yes Polyflex G FR Yes Yes No No Yes Yes Polyflex SAP or SAP FR Yes Yes Yes (See 5.5.1) No Yes Yes Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Yes Yes I Yes (See 5.5-1) No Yes Yes 5.5.1 "Foam -On Tile" is limited to use of the following Approved the adhesives / underlayment combinations. TABLE 1A: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS) Adhesive Florida Product I Underlayments Approval DAP Foam Touch `n Seal StormBond Roof FL14506 Polystick TU Plus, Polystick TU Max Tile Adhesive DowTileBond'" FL22525 PolystickTU P, PolystickTU Plus, Polyflex SAP or Tile Pro PolystickTUP, PolystickTU Plus, PolystickTU Max, Polystick Tile Pro, ICP Adhesives Polyset® AH-160 FL6332 Ellastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mlle -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro, ICP Adhesives Polyset® RTA-1 FL6276 Elastoflex G TU, Elastoflex SIS G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, M l le -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) Polyglass PolyLok Roof Tile Adhesive FL17855 Polystick TU Plus or Polystick TU Max 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Exterior Research and Design, I.I.C. Certificate of Authorization #9503 6EDITION (2017) FBC NO Polyglass Roof Undedayrr for Overturning Moment Resistance Performance. iZ EVALUATION (570) 364-1230 Evaluation Report P12060.02.09-1123 FL5259-R27 Revision 23: 09/14/2017 Page 5 of 14 6.4.1 6.4.2 6.4.3 Shall be installed in compliance with the coi for the type of prepared roof covering to be All self -adhering materials, with the exception Cap Sheet or SA APP Cap Sheet (FR) should be Hide Back Nailing Guide. Nails shall be corrosic metal disk or Simplex -type metal cap nail, at using the above noted fasteners and spacing, i The head lap membrane is to cover the area bE All seal -lap seams (selvage laps) must be firmly rolled with a minimum 28 lb. hand roller to ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). C�o ,I TPJNITYIERD requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 led. of Polystick TU Plus, Polyflex SAP or SAP FIR and Mule -Hide SA-APP back -nailed in selvage edge seam in accordance with Polyglass / Mule- n resistant, 11 gauge ring -shank type with a minimum 1-inch diameter 3 minimum rate of 12" o.c. Polystick TU Plus should be back -nailed i area marked "nail area, area para clavar" on the face of membrane. ne back -nailed. View of Ovelap Seam of Dual Pro and Tile Pro All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap. Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement to the are Ia in need of repair, followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be installed in a water shedding manner. All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the roof that are not accessible to a large roller or broom. Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1. For adhesive -set tile applications, refer to Section 5.6.4 herein. For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile. 6.4.4 Two (2) Ply Underlayment Systems: Polystick MTS followed by Polystick MTS, TU P, TU Plus, TU Max, Tile Pro, MU-X or Polyflex SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-�ply underlayment system is desired. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R23 Certificate of Authorization#9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27 PoWlass Roof Unde'dayments, (570) 384-1230 Revision 23: 09/14/2017 Page 12 of 14