NOTICE OF ACCEPTANCE (NOA
Petersen Aluminum Corporation
102 Northpoint Parkway, B1dg.106
Acworth, GA. 30102
RECEIVED
MAR 1 9.1010
pp fitting Department
1lk1) Lucie Count',
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade.aov/economv
SCOPE:
This NOA is being issued under the applicable ru es and regulations governing the use of construction materials. The
documentation submitted has been reviewed and es
by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas wher, allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration i
(In Miami Dade County) and/or the AHJ (in area
or material tested for quality assurance purposes.
manufacturer will incur the expense of such testis
of such product or material within their jurisdicti
determined by Miami -Dade County Product Con
of the applicable building code.
This product is approved as described herein, an(
including the High Velocity Hurricane Zone of t�
DESCRIPTION: Edge-Loc 1.0: x 16"
ate stated below. The Miami -Dade County Product Control Section
other than Miami Dade County) reserve the right to have this product
f this product or material fails to perform in the accepted manner, the
and the AHJ may immediately revoke, modify, or suspend the use
i. RER reserves the right to revoke this acceptance, if it is
of Section that this product or material fails to meet the requirements
l has been designed to comply with the Florida Building Code
ie Florida Building Code. CONCEALED FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBury OF THE
x 24 ga. Steel Panel over Wood Deck CONTRACTOR OR RECORD
LABELING: Each unit shall bear a permanentl label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Contr 1 Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered Oer a renewal application has been filed and there has been no change
in the applicable building code negatively affecng the performance of this product.
TERMINATION of this NOA will occur afte�the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number
expiration date may be displayed in adverti
in its entirety.
INSPECTION: A copy of this entire NOA s'.
shall be available for inspection at the job site
This NOA renews and revises NOA 14-0129.
The submitted documentation was reviewed
MIAMI•DADECOUh1TY ST. LUCIE C01
REVIEWED FO
PLANS AND PE-
SITE OR NO IN
eded by the words Miami -Dade County, Florida, and followed by the
literature. If any portion of the NOA is displayed, then it shall be done
s
all be provided to the user by the manufacturer or its distributors and
it the request of the Building Official.
THESE PLANS AND ALL PROPOSED WORK
1 and consists of pages 1 throuUBJECT TO ANY CORRECTIONS U RED BYFIELDINSPECTORS THAT
Freddy SeminoMAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
IN NOA No.: 17-1002.16
PC%�T���� Expiration Date: 03/16/24
d lE Approval Date: 11/02/17
Page 1 of 5
r BE KEPT ON JOB FILE"""o Py
(S) WILL BE MADE U
ROOFING ASSEMBLY APPROVAL
Category:
Roofic
Sub -Category:
Metal,
Materials:
Steel
Deck Type:
Wood
Maximum Design Pressure
—1011
TRADE NAMES OF PRODUCTS MANUFA
Product Dimensions
Edge-Loc 1.0 Length: various
Width: 16"
Height: 1"
Thickness 0.024" (24 ga.)
Min. Yield Strength: 50 ksi
Trim Pieces Length: varies
Width: varies
Thickness 0.024" (24 ga.)
EVIDENCE SUBMITTED:
Test Agency
Valspar
Valspar
Force Engineering & Testing
Inc.
Farabaugh Engineering and
Testing Inc.
IED OR LABELED BY APPLICANT:
Test Product
Specifications Description
TAS 110 Corrosion resistant, prefinished, coated
galvanized, galvalume, standing seam, metal
panels.
433�11515
433B 173
72-0314�-06A-C
T
A
N/A Corrosion resistant, prefinished, coated
galvanized, galvalume, standing seam, metal
panels.
Test Name/Reyort
Date
ASTM B 117
11/21/11
ASTM D 4587, ASTM G 23
11/21/11
TAS 125
03/24/07
TAS 100 04/14/07
NOA No.: 17-1002.16
Expiration Date: 03/16/24
Approval Date: 11/02/17
Page 2 of 5
APPROVED ASSEMBLIES:
System: Edge-Loc 1.0 Panel x l
Deck Type:
Deck Description:
Slope Range:
Maximum Uplift
Pressure:
Wood, Non -Insulated
New Construction 1-9/3
greater plywood.
2": 12" or greater
See Table A below
6" Wide x 24 ga. Steel
" or greater plywood or wood plank, or for re -roofing 15/32" or
Deck Attachment: In accordance with applicable
Building Code, but in no case shall it be less than 8d ring
shank nails spaced 6" I
.c. In reroofing, where the deck is less than 19/32" thick (Minimum
15/32") The above att
hment method must be in addition to existing attachment.
Underlayment: Minimum underlaym
nt shall be an ASTM D 226 Type II installed with a minimum 4"
side -lap and 6" end -la
s. Underlayment shall be fastened with corrosion resistant tin -caps
and 12 gauge 1 '/a" a
ular ring -shank nails, spaced 6" o.c. at all laps and two staggered
rows 12" o.c. in the fi
Id of the roll. Or, any approved underlayment having a current NOA.
Fire Barrier Board: Any approved fire ba
ier having a current NOA. Refer to a current fire directory listing for
fire ratings of this roo
mg system assembly as well as the location of the fire barrier within
the assembly. See Limitation
# 1.
Valleys: Valley construction s)
all be in compliance with Roofing Application Standard RAS 133
and with PAC Contra)
tors Association's current published installation instructions.
Metal Panels and Install the "Edge -Lod
1.0 Panel" and accessories in compliance with the current published
Accessories: installation instructio
s and details in PAC Contractors Association's Installation Manual.
Flashings, penetrati ns,
valley construction and other details shall be constructed in
compliance with Roo
mg Application Standard RAS 133.
Panels shall be secured at a spacing listed below in Table A with corrosion resistant #10-13
x 1" pancake head screws of sufficient length to penetrate through the sheathing a minimum
3/16 of an inch.
The adjacent panel shall overlap and be secured to each other when The female rib of panel
is snapped over the _„_{tale rib of panel.
MAX
TABLE A
MUM DESIGN PRESSURES
Roof Areas
Field
Perimeter and Cornerl
Maximum Design Pressures
—59.75 psf.
—101 psf.
Maximum Screw Spacing
16" o.c.
6.75" o.c.
1. Extrapolation shall not be allowed
NOA No.: 17-1002.16
Expiration Date: 03/16/24
Approval Date: 11/02/17
Page 3 of 5
SYSTEM LIMITATIONS
1. Fire classification is not part of this accept,
ratings of this product.
2. The maximum designed pressure listed her
and corners). Neither rational analysis, nor
pressure zones (i.e. perimeters, extended cc
3. Panels may be rolls formed in continuous 1
Roofing Application Standard RAS 133.
refer to a current Approved Roofing Materials Directory for fire
shall be applicable to all roof pressure zones (i.e. field, perimeters,
rapolation shall be permitted for enhanced fastening at enhanced
rs and corners).
the from eave to ridge. Maximum lengths shall be as described in
4. All panels shall be permanently labeled wit the manufacturer's name and/or logo, city, state, and the following
statement: "Miami -Dade County Product ntrol Approved" or with the Miami -Dade County Product Control
Seal as seen below. All clips shall be per anently labeled with the manufacturer's name and/or logo, and/or
model.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrativel Code.
6. Panels may be shop or j.obsite roll formed
PAC Contractors Association or manufac
MIAMI•DADE COUNTY
JAPPROVED1 -A
machine models # 10110884, E00578860, or 01110072 from
at Petersen Aluminum Corporation's plant in Acworth, GA.
NOA No.: 17-1002.16
Expiration Date: 03/16/24
Approval Date: 11/02/17
Page 4 of 5
4-
Ribs and Striations are Optional
1.0 PANEL SYSTEM
NOA No.: 17-1002.16
Expiration Date: 03/16/24
Approval Date: 11/02/17
Page 5 of 5