Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFINGBusiness& Professional Regulation AS CONNdO9 BCIS Home I Log In I User Registration I Hot Topics i, Submit Surcharge I Stats & Fads I Publications I FBC Staff I BCIS Site Map a „ b Product ApprovalI *USER: Public User Product Approval Menu > Product or Annlication Search > Application List > Application Detail OFFICE OSECRUARY F THE # FL1702Z=R == Application Type Revision Code Version 2017 Application Status Approved Comments 08/18/2017v. date reapply 08/21/17 Archived roductrManufactu`rer_ creme=MeteL.Fabricators,..LLC _ Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772)872-8034 fivalidation@yahoo.com Authorized Signature Richard McKuhen fivalidation@yahoo.com Technical Representative Richard McKuhen Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772)872-8034 rchard@emfab.net Quality Assurance /Representative Add ress/Phone/Ernail Cag tegory_` Rol ofing-- Subcat:60 , ym ta,I Roofi - E -.:- _ Links I Search I Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer D Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the LOCKE BOWDEN Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/22/2o24 Validated By Zachary R. Priest, P.E. Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code f6 Validation Checklist - Hardoopy FL17022_R7_COI FL 17022 1_ V CRIMP_ sr.odf 97121darA Year TAS 125 2003 UL 1897 UL 580 2012 2006 Product Approval Method Method i Option D Date Submitted 08/18/2017 Date Validated 08/25/2017 Date Pending FBC Approval 08/28/2017 Date Approved 10/10/2017 Summary of Products FL * Model, Number or Name Description 17022.1 1 - "5V Crimp" (116) 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel mechanically attached to 15/32" plywood or Wood Deck with fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No LF 17022_37_ II_FL 17022.1 5 V CRIMP_ssr.pdf Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for conditions. Install the FL17022_R7 AE_FL 17022.1 5 V CRIMP_ssr.pdf assembly in compliance with the installation method listed in Created by Independent Third Party: Yes this report and applicable code sections of FBC. Refer, to manufacturer's installation instructions. 17022.2 2 - "5V Crimp" (116) 0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel, mechanically attached to 15/32" plywood or Wood Deck with exposed fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II _FL 17022.2_5 V CRIMP 0.032 ALUM ssr.pdf Verified By: Locke Bowden, P.E. 49704 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for conditions.Install the FL17022_g7 AE FL 17022.2_5 V CRIMP 0,032 ALUM ssr.pd Created by Independent Third Party: Yes assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.3 3 - "13' Mechanical Seam" (115) 1.5" rib height, 16" wide, 24 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.3_1.5 MECHANICAL Approved for use outside HVHZ: Yes sea m_24ga_.5sr.pdf Impact Resistant: No Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/ -Table A Created by Independent Third Party: Yes Other: Refer to evaluation report for conditions and Evaluation Reports limitations of use. Install the assembly in compliance with the FL17022_R7 AE_FL 17022, 1.5 MECHANICAL installation method listed in this report and applicable code seam_24ga ssr.pdf sections of FBC. Refer to manufacturer's installation Created by Independent Third Party: Yes instructions. 17022.4 4 - "13' Mechanical Seam" (115) 1.5" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to 15/32" plywood or Wood Deck with dips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17 22_ 77 111 FL 17022.4 MECHANCIAL SEAM Approved for use outside HVHZ: Yes ALUMINUM ssr.gd Impact Resistant: No Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/ -Table A Created by Independent Third Party: Yes Other: Refer to evaluation report for conditions and Evaluation Reports limitations of use. Install the assembly in compliance with the FL17022_R7 AE_FL 17022.4 MECHANCIAL SEAM installation method listed in this report and applicable code ALUMINUM s�r.pd sections of FBC. Refer to manufacturer's installation Created by Independent Third Party: Yes instructions. 17022.5 5 - "1 in. Nail Strip" (R5) 1" rib height, 16" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL'17022_R7_II FL 17022.5_1.0 NAILSTRIP ssr.pdf Verified By: Locke Bowden, P.E. 49704 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Palm City, FL 34990 Compliant with Florida Building Code 2017 (6' ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Underlayment: To be compliant with FBC Sec. Chart 1507.1.1 Slope: Shall be in compliance with FBC Sec.1507. See Fastener attachment specifications above TROD 1 METHOD 2 METHOD 3 METHOD 4 t6 PSFIlk -93.5 PSF -102 PSF -228 PSF 26" O.C. 8" o.c. 6" o.c. !" o.c. 2 2 " 0.c. 12" O.C. 12" o.c. [59�' #10 #10 #10 Reference Data: ARCHITECTURAL TESTING, INC. TST ID#:1527 UL 580-06 & 1897-041 Test Report 1115893.01-450-18 05/02/14 Test Report F3366.01-450-18 12/18/15 TAS 225-03 Test Report D05893.02-450-18 07/22/14 *EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897-12 *Design pressure margin ofsafety 2:1 \1k1k t Locke Bowden, P.E does not have, not will acquire a financial in yq acggrniq�facturing or distributing products under this evaluation. Locke Bowden, P.E. is not owned, operated, or controlled by any conipanVomAidifatturep, or distributing products under this report. :? :.we-i .*1= rr• �� COf?1D�r N �'!f• `• � o A fill �,• 1.+ t � FL17022.1 6V cramp (26GA Steel), 24" Wide Roof `ravel - Details Limi ations: 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engineering analysis for project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. 15(32" or greater Plywoocl, or Wood plank 24- 12' 318' oPrtorius7i Nominal 12" Nominal 12" O.C. O.C. Fasten LM x 1-1/2" Min. or #10 x 1-1/2" Min. per —fable "A" Hex Washer Head Screw Spaced 12" o.c. across the Panel Width Panel Refer to Table "A" for Spacing Along Panel Overlap Length Deck-15/32" or greater Plywood, or Wood plank