HomeMy WebLinkAboutREVIEW-COMMENTSPlanning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462.2172 Fax:(772)462-6443
PROPERTY INFORMATION '
Address: 3605 S Indian River Dr
City / State / Zip: Fort Pierce, FI 34982
Parcel #: . 2426-313-0001-000/2
Zoning: RE-2
APPLICATION INFORMATION
Permit Number: 1803-0610
I _
PjUANNED
BY
i REVIEW COMMENTS
I,
Page 1
Permit Type: ROOF - MODIFIED BITUMEN
CONTRACTOR INFORMATION
Contractor Name:
Kyle White
Business Name:
I
J A Taylor Roofing Inc'
i
Business Addr:
302 Melton Dr
City / State / Zip:
Ft Pierce, FI 34982
Owner(s):
Nasreen Wilkes
Jurisdiction: SAINT LUCIE COUNTY
Lot#: 4 Block:
Stories: Automatic Sprinkler System? No
Fax Number: 772-468-8397
Email: Nadine@Jataylorroofing.Co
m
REVIEWS AND COMMENTS
Review Type Status Reviewed By Date Started Date Completed Date Released
FRONT COUNTER REVIEW COMPLETE I Karen Nielsen 3/21/2018 3/21/2018 3/2112018
Comment: i
PLANS EXAMINER REVIEW INCOMPLETE Terry Chissoe 312212018
Comment: SEE PAGE 2 OF 58 OF PRODUCT APPROVAL FL 1654-R22, LINE 9. FOR MECHANICALLY ATTACHED
COMPONENTS OR PARTIALLY BONDED INSULATION THE MAXIMUM DESIGN PRESSURE FOR THE
3/23/2018 SELECTED ASSEMBLY SHALL MEET OR EXCEED THE ZONE 1 DESIGN PRESSURE DETERMINED IN
ACCORDANCE WITH THE FLORIDA BUILDING CODE CHAPTER 16, AND ZONES 2 AND 3 SHALL EMPLOY AN
ATTACHMENT DENSITY DESIGNED BY A QUALIFIED DESIGN PROFESSIONAL TO RESIST THE ELEVATED
PRESSURE CRITERIA.
Comment: SEE PAGE 2 OF 58 OF PRODUCT APPROVAL FL 1654-R22, LINE 11. FOR MECHANICALLY ATTACHED
COMPONENTS OVER EXISTING DECKS, FASTENERS SHALL BE TESTED IN THE EXISTING DECK FOR
3/23/2018 WITHDRAWAL RESISTANCE. A QUALIFIED DESIGN PROFESSIONAL SHALL REVIEW THE DATA FOR
COMPARISON TO THE MINIMUM REQUIREMENTS FOR THE SYSTEM. TESTING AND ANALYSIS SHALL BE IN
ACCORDANCE WITH ANSI/SPRI FX-1 OR TESTING APPLICATION STANDARD TAS 105.